| 1 | P/Laying of Ferrow cement concrete in 1:2:4 cement appd coarse sand and 20mm stone grite and mixing water proofing compound at the rate of 1 kg./ Bag of cement in thickness of 5cm. Avrage including embedding of expended metal jali of 6 gauge iron wire including and fixing over slab including 6mm thick cement plaster in 1:2 cement and c sand mortor finished with floating coate of need cement PWD SOR New Item 2 |
| 2 | Scraping of old exisiting damage White / colour wash and desposal of refuse |
| 3 | Dismentaling of old exisiting damage Tils work floor and desposal of refuse DSR Code No 15.23.1 |
| 4 | Laying of PCC 1:4:8 with cement ,sand and 40 mm stone ballast in foundation DSR Code No 4.1.8 |
| 5 | p/laying of vitrified tiles in different sizes with water absorption less than 0.08% .including grouting of joints ,laid with 1:3 cement sand mortar complete DSR No 11.47.2 |
| 6 | P/ applying plaster of paris putty of avg. thickness 2mm of appd. Brand over the plastered wall surface to prepare to surface even and smooth DSR No 13.26 |
| 7 | finishing wall tex tured exterior paint of required shad : new work ( two or more coat) @3.28ltr /10sqm over and including priming coat of exterior primer applied @2.20kg /10sqm DSR Code No 13.45.1 |
| 8 | Painting with synthetic enamel paint of appd. Brand two or more coats over an under coat DSR Code No 13.62.1 |
| 9 | 12mm thick plaster work in 1:4cement and fine sand mortor DSR Code No 13.1.1 |
| 10 | Transpotation charge from workshop to site |
| 11 | Repairing of door and windows with oxidise iron fitting with locking arragement |
| 12 | P/F of Robotics cum Drone Lab Appratus and all accessories As per Attach quotation |
| 13 | imformation board + photography |
| 14 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C- DSR 1.10.3 |
| 15 | Submains : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.- 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire- DSR1.14.1 |
| 16 | Submains :Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.- 2 X 4 sq. mm + 1 X 4 sq. mm earth wire- DSR1.14.3 |
| 17 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.- DSR1.25 |
| 18 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.- DSR1.31 |
| 19 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.- DSR1.32 |
| 20 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. (for A.C. Point/MCB Point)- DSR1.57 |
| 21 | Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)-4 way (4 + 12), Double door- DSR2.4.1 |
| 22 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.- DSR2.1-Single pole |
| 23 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. - Supply and fixing of 63 Amp. FP MCB (10 KA) C Curve. CAT A-Marcket Rate |
| 24 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.- DSR5.4 |
| 25 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)- DSR5.9 |
| 26 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.- Marcket Rate. |
| 27 | Supply and fixing of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect.CAT. - AAA- DSR-1413 |
| 28 | Supply of 3 KW Solar Power Plant (off grid) with module mounting structure , 48V, 240AH Battery (MNRE Approved) backup , 4.0 KVA Invertor etc …. Complete (5 year warranty) |
| 29 | Installation Charges Please Enable Macros to View BoQ information |