| 1 | Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth, for foundation etc or for shafts, wells, manholes, pier holes, laying of cables etc n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed. |
| 2 | Excavation in trenches n.exc 1.5 m wide and exc 1.5 m but n.exc 3 m in depth, for foundation etc or for shafts, wells, manholes, pier holes, laying of cables etc n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed. |
| 3 | Excavation in trenches n.exc 1.5 m wide and exc 3 m but n.exc 4.5 m in depth, for foundation etc or for shafts, wells, manholes, pier holes, laying of cables etc n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed. |
| 4 | Removing excavated material to a distance n exc 50 m and deposited where directed at a level n exc 1.5 m above the starting point complete all as specified and as directed. |
| 5 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft / loose soil complete all as specified and as directed. |
| 6 | M&L for PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 7 | M&L for PCC 1:3:6, type C2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 8 | M&L PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in surface channels and drains and benching including finishing the top of benching even and smooth with using extra cement complete all as specified and directed. |
| 9 | M&Lfor brick work with sub-class 'B' bricks (using old size), straight or curved on plan exc 6m mean radius built in In cement mortar 1:6 complete all as specified and directed |
| 10 | M&L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and directed. |
| 11 | M&L providing cement concrete 1:2:4, type B0 (using 12.5 mm graded stone agg) as in lintel up to 1.5 mtr clear span, cills,steps,seismic and other similar bands , plinth course , string course,lacing course,parapets and railing up to 60cm in height,coping,kneelers,apex stones,bed plates kerb, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 12 | S &F Framed work such as door frame, grills, gratings, etc., with ends of bar shoulder &/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks with Angle, MS sheet Flat iron & similar work conforming to Fe 290 GDE -E-165 complete all as specified and directed. |
| 13 | M&L preparation new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint (Ist quality) over and including one coat of red oxide zinc chrome primer complete all as specified and directed. |
| 14 | Supply and fix RCC ferro cover 75 mm thick of M-25 grade and size ( 600 mm x 800 mm) with mild steel plate frame of min 1.25 mm thick, chequered finish on top with min 02 Nos hooks to place cover complete all as specified and as directed by Engineer-in-Charge. |
| 15 | Supply and fix RCC ferro cover 75 mm thick of M-25 grade and size ( 1000 mm x 800 mm) with mild steel plate frame of min 1.25 mm thick, chequered finish on top with min 02 Nos hooks to place cover complete all as specified and as directed by Engineer-in-Charge. |
| 16 | M & L for providing precast cement concrete type B1 1:2:4 (using 20mm graded aggregate) in landing, cover slab (for man hole etc) chullah hood, chajjas, water troughs, mangers, shelves and similar articles with plain faces incl form work set in cement mortar 1:4 complete all as specified and directed. |
| 17 | M&L Mild steel TMT bars 6 to 8mm dia, cut to length, bent to shape requried, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 18 | M&L for rendering 15 mm thick in CM 1:4 on brick / stone masonry surfaces or other than fair faces of brick work on walls finished even and smooth without using extra cement complete all as specified and directed. |
| 19 | M&L for PCC 1:3:6, type C2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 20 | M&L for boring hole in rain water harvesting pit in any type of soil of PVC / HDPE 150 mm bore pipe upto 15m deep etc concrete complete all as specified and directed. |
| 21 | S&F 150 mm bore dia perforated PVC / HDPE pipe in bore hole complete all as specified and directed. |
| 22 | M&L for coarse sand filling under floor of water harvesting pit of specified thickness complete all as specified and directed. |
| 23 | M&L for filling of broken stone aggregate of gauge 5 to 10 mm complete all as specified and directed. |
| 24 | M&L for filling of broken stone aggregate of gauge 63 to 100 mm complete all as specified and directed. |
| 25 | M&L for filling of broken stone aggregate pea gravel of gauge 3.60 mm complete all as specified and directed. |
| 26 | M&Lfor brick work with sub-class 'B' bricks (using old size), straight or curved on plan n. exc 6m mean radius laid dry in lining of trench complete all as specified and directed |
| 27 | M&L for rendering 10 mm thick in CM 1:6 on fair faces of brick masonry / concrete surfaces or concrete surface of wall finished even and smooth without using extra cement complete all as specified and directed. |
| 28 | M&L providing cement concrete 1:3:6, type C-1 (using 20 mm graded stone agg) as in lintel up to 1.5 mtr clear span, cills,steps,seismic and other similar bands , plinth course , string course,lacing course,parapets and railing up to 60cm in height,coping,kneelers,apex stones,bed plates kerb, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 29 | M&L for hard drawn steel wire fabric exc. 4.0 kg/ sqm cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.90 mm in dia supplied and fixed complete all as specified and directed. |
| 30 | M&L for cleaning of mud/ debries / silt from existing drain of width 300 mm to 600 mm and depth of drain from 300 mm to 1000 mm, if necessary including removal of drain cover and refixing after cleaning and removal of debries outside the MD land in closed container complete all as specified and directed. |
| 31 | Excavation over areas n exc 1.5m deep and getting in any type of soil complete all as specified and as directed. |
| 32 | S & F rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc, complete drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and incl either hooks and pintal hinges or steel hanging door fittings (exclusive of steel, sheeting or other covering, running rails and guides) and hanging, also fastening and fixing complete confirming to Fe-290 Gde-E-165 complete all as specified and directed |
| 33 | M&Lfor brick work with sub-class 'B' bricks (using old size), straight or curved on plan exc 6m mean radius built in In cement mortar 1:4 complete all as specified and directed |
| 34 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/ stopped ends etc complete all as specified and directed. |
| 35 | Add or deduct for each 25 mm girth or part thereof over or under 30 cm using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed. |
| 36 | M&L for rendering 15 mm thick in CM 1:4 on fair faces of brick masonry surfaces or concrete surface of wall finished even and fair including mixing of WPC as per manufacturers instruction complete all as specified and directed.Note : WPC shall be measured and paid seperately as supply only |
| 37 | Supply only water proofing compound, ISI marked, complete all as specified and directed. |
| 38 | Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ Please Enable Macros to View BoQ information |