| 1 | Disconnecting from mains and taking down for servicing of Water Cooler of Capacity 40/80, 60/120, Litres including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, fan and blower, etc., and keeping the Water cooler unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and installation in same location complete all as specified and as directed .Note :- 1. Replacement of defective spares for making the water cooler units in satisfactory working condition will be measured & paid separately under relevant items and Transportation & labour charges for taking down old spares and fixing of new spares shall deemed to be included in unit rate quoted above. |
| 2 | S & F in replacement over load protector relay suitable for 40 to 150 litrs Litres capacity water coolers complete all as specified and as directed . |
| 3 | S & F in replacement Starting relay suitable for 40/80, 60/120, 150/150 Litre complete all as specified and as directed . |
| 4 | S & F in replacement thermostat suitable for 40/80/120/150 Litre capacity water coolers. |
| 5 | S & F in replacement condenser motor fan blade suitable for 40/80/120/150 Litre capacity water coolers complete all as specified and as directed . |
| 6 | Disconnecting the electric mains and taking out unserviceable condenser fan motor 1/32hp to 1/16 HP as per site requirment from water cooler cap.40/80,60/120, 150/150 Litre and supply and fixing with new motor single phase AC 220 V of same capacity including reconnecting the electric connections and testing complete all as specified & as directed. |
| 7 | S & F in replacement Starting Capacitor 25 MFD complete all as specified and as directed . |
| 8 | S & F in replacement running Capacitor 10 MFD complete all as specified and as directed . |
| 9 | S & F in replacement waste water tray complete suitable for 40/80, 60/120, 150/150 Litre capacity water coolers complete all as specified and as directed . ( Suitable for Voltas/Sidwal/Blue Star make water coolers). |
| 10 | S & F in replacement chromium plated push taps suitable for 40/80/120/150 Litre capacity water coolers all as directed. |
| 11 | M&L for Float valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for 15mm bore iron pipe, weight not less than 140 grams including taking down existing complete all as specified and directed. |
| 12 | M&L for waste water adaptor PVC, 32mm size suitable for water cooler of any capacity fixed as in repair complete all as specified and directed. |
| 13 | S&F of PVC drain out pipe, heavy duty 32/40mm dia, wall thickness 2mm complete with fittings such as nipple, clips etc complete fixed to water coolers of any capacity fixed as in repair complete all as specified and directed. |
| 14 | Taking down unserviceable PVC connection pipe and Supply and Fixing of PVC connections 15 mm dia bore with PTMT nuts of length 900 mm complete all as specified & as directed. |
| 15 | Dismantling and removing defective compressor and supply and fixing in repairs new sealed compressor of approved make obtained from authorised dealers commissioning and testing Water Coolers of 40/80 ,60/120/150/150Litres capacity complete all as specified and as directed. |
| 16 | Disconnecting the mains and taking out the unserviceable condenser coil and supply & fixing new condenser coil as per existing size & patterns for Water Coolers of capacity 40/80 , 60/120, 150/150 Litres complete all as specified & as directed. |
| 17 | M&L for taking down desert cooler of any type/size/model from any height / floor for servicing like changing of wood wool pads, kit motor, submersible pump, fan blade, front grill, wiring, capacitor, cleaning or any other repair work ,greasing of fan motor/pump and replacement of PVC pipe worn out nut, bolts and washers as specified and re-fixing to existing place after repair work/overhauling complete all as specified and directed.Note :- (i) The rates quoted by the contractor shall deemed to include the cost of T&P.(ii) The items required to be replaced shall be measured and paid separately under relevant items. |
| 18 | Preparation for old painted surface of desert cooler of any capacity and any make on inner surface & outer surface. Repainting the complete desert coolers i.e. side panel, bracket, body & desert cooler stand with two coats of synthetic enamelled paint (1st grade quality) including two coats of black water proof paint on reserve water tank complete all as specified & as directed. |
| 19 | Providing and fixing protective shed over outdoor units of Split ACs to safeguard from direct sunlight and rain, fabricated with 0.5 mm thick GI sheet (corrugated/plain or powder coated) fixed over MS angle framework , installed with proper slope for rainwater drainage, ensuring minimum 300 mm side clearance and 450 mm vertical clearance for ventilation, complete with cutting, welding, anchor fasteners, and two coats of enamel paint over red oxide primer complete all as specified & as directed. |
| 20 | S & F in replacement wood wool pad of suitable size for 24” sweep desert cooler, 01 Set comprising of 3 Nos of pads approximate weight 500-600 Gms as per sample complete all as specified & as directed. |
| 21 | S & F in replacement wire mesh for desert cooler pad (Set of Three) including taking down old one. complete all as specified & as directed. |
| 22 | S & F in replacement submersible pump 230 Volts,1/15 HP to 1/40 hp (as per site requirment) single phase, AC suitable for Plastic body/Steel body Desert cooler. complete all as specified & as directed. |
| 23 | S & F in replacement PVC pipe for connecting pump and water distributor of size 15 mm dia including PVC elbow,.complete all as specified & as directed. |
| 24 | S & F in replacement PVC elbow for desert cooler of suitable size .complete all as specified & as directed. |
| 25 | S & F in replacement PVC 4 Way distribution cross for desert cooler complete all as specified & as directed. |
| 26 | S & F in replacement running capacitor of 4/6 MFD capacity for desert cooler complete all as specified & as directed. |
| 27 | M&L for Aluminium heavy duty Fan blade with bush powder coated for fan motor of desert cooler 20 inch sweep including taking down old unserviceable fan blade complete all as specified and directed. |
| 28 | M&L for PVC heavy duty Fan blade with bush for fan motor of desert cooler 20 inch sweep including taking down old unserviceable fan blade complete all as specified and directed. |
| 29 | M&L for cast Iron ring of cooler Fan motor Leg set (RH & LH) with clamps suitable for desert cooler complete with nuts & bolts including taking down old unserviceable complete all as specified and directed. |
| 30 | Supply and fixing in repairs of desert cooler kit fan motor, single speed, 230 V, 50 Hz of capacity 90 Watt 1450 RPM, copper wounded including nuts bolts for fixing complete all as specified and as directed. |
| 31 | Supply and fixing Desert cooler exhaust fan motor, single speed, 230 V, 50 Hz of capacity 150 Watt 1400 RPM, copper wounded including nuts bolts for fixing including taking down old unserviceable one complete all as specified and as directed. |
| 32 | S&F of 15mm size stop cock of PTMT in any colour screwed for iron pipe and weight not less than 90 gram per cock fixed in repair complete all as specified and directed. |
| 33 | M&L for Plug top, three Pin, 5/6 Amps, 230 volts, ISI Marked including taking down old unserviceable complete all as specified and directed. |
| 34 | M&L for switch piano type, 240 volts, Singe Pole, one ways, 5/6 Amps, ISI Marked, fixed in desert coolers including taking down old unserviceable complete all as specified and directed. |
| 35 | M&L for selector switches three way, 230 volts single phase of standard quality fixed in desert coolers fixed in repair complete all as specified and directed. |
| 36 | M&L for 1.50 sqmm, PVC insulated and sheathed round flexible three core copper conductor cable including necessary connection fixed in desert coolers complete all as specified and directed. |
| 37 | M&L for front grill/louvers to desert cooler made out from 0.80 mm thick Galvanised Iron sheet of approved make suitable for fixing 5 Amp switch, three speed regulator and indicating lamp. suitable for 5000/4000 Cum/hours capacity desert cooler of any make fixed in repair complete all as specified and directed. |
| 38 | S&F of side shutter made out from 0.80 mm thick galvanised iron sheet of capacity 4000/5000 cum/hours desert cooler fixed as in repair complete all as specified and directed. |
| 39 | S&F of Mild Steel Sheet body of 22 gauge suitable for coolers of capacity 4000/5000 Cum/hour including taking down old unserviceable complete all as specified and directed. |
| 40 | Supply and fixing in replacement Gl powder coated perforated type cable tray 14 SWG, (2mm thick) of width 150mm and height 50mm with necessary coupler plate and cable tray cover where required with PVC tie for fixing of cable compete all as specified and directed. |
| 41 | S&F in repairs desert cooler body of size 25 inch x 25 inch x 36 inch (height) of sheet 20 Gauge and with side panels (03 Nos) fabricated out of 22 SWG PGI Sheet along with PVC front grill, distribution switch, 5 Amp piano switch and tank of depth 11 inch. Painting the complete desert cooler i.e., side panel, bracket body with two coat of synthetic enamel paint (Ist grade quality) over a coat of red oxide zinc chrome primer and two coat of black water proof paint on reserve tank and marking with \\" GE(AF) JAISALMER (MES)\\" letter size of 50mm height in stencil in black/white complete all as specified & as directed. |
| 42 | S&F for wall mounted remote control holder/stand for Split/Window type Air-conditioner units, moulded from high-quality ABS/Polycarbonate plastic, of approved design and finish, suitable to accommodate standard AC remote controllers. The work shall include supply of holder, drilling holes in wall, fixing with stainless steel screws and nylon/rawl plugs, making good disturbed surface, and handing over in neat functional condition complete all as specified and as directed. |
| 43 | M&L for making one number hole of upto 20” (Twenty Inches) length and 2” (Two Inches) diameter in existing wall/slab (RCC/brick/stone) by means of core cutting machine, including proper fixing of machine, T&P, labour, scaffolding as required, ensuring neat and clean finish without damage to adjoining surface, and after completion of work, properly filling the annular gap around the pipe/opening with cement mortar (1:2) or white cement as required, finishing the surface flush with adjacent area, cleaning the site of all debris and making good the surface, all complete as per specification and as directed by Engineer-in-Charge. |
| 44 | M&L for the painting work for AC outdoor unit stand /shade exposed to direct sunlight, including surface preparation (mechanical scrubbing and rust removal), applying one coat of anti-corrosive primer (conforming to IS standards), followed by two coats of weather-resistant enamel paint in the specified color as per the directions, ensuring smooth and uniform finish, proper material labeling, and adherence to color codes for uniformity and aesthetic appearance omplete all as specified and directed. |
| 45 | M & L for surface restoration work at locations where split or window AC units were previously installed, including filling existing holes made for pipes, cables, drainage, or mounting brackets with appropriate cement mortar. also including rectifying any damage caused during the installation or removal of the units, ensuring a smooth and uniform surface finish, and restoring the area to its original condition as per the instructions of the engineer-in-charge |
| 46 | M &L for detecting the leakage of gas of Water coolers at any location and rectifying the defect to stop the leakage by gas welding or by any other means including cutting and brazing of copper tubes testing and commissioning complete in satisfactory working condition complete all as specified & as directed. |
| 47 | Supply and filling refrigerant gas R-134A/R32/R410/R600/R-410C in Refrigerators/ Deep freezers/ Water coolers of any capacity, model and make complete all as specified and directed by engineer in charge. |
| 48 | Taking down for servicing of split type AC 1.5/2 TR Capacity of any type or make by opening the condenser unit fixed on roof top and cooling unit fixed inside the building and including cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner or cleaning solution and reassembling of complete unit in satisfactory working condition after necessary servicing as required and refaxing the same in existing position ,and including testing for smooth functioning complete all specified and as directed . |
| 49 | All as per srl item No 48.00 here-in-before but window type AC of capacity 1.5/ 2 TR complete all as specified and as directed. |
| 50 | Material & Labour for rectifying electrical wiring fault of any type of wiring (concealed/surface/casing-capping/conduit/outdoor /indoor of split ac) capacity type AC and make them functional and also carry out the required repair work as per site requirement and make good the disturbed surface as directed by engineer in charge. |
| 51 | M&L for running capacitor, 55+6 MFD and one point for blower motor suitable for Air Conditioner of capacity 1.5/2.0 TR fixed as in repair complete all as specified and directed. |
| 52 | M&L for running capacitor, 45+4 MFD and one point for blower motor suitable for Air Conditioner of capacity 1.5/2.0 TR fixed as in repair complete all as specified and directed. |
| 53 | M&L for starting capacitor 2.50 MFD suitable for Air Conditioner of capacity 1.5/2.0 TR fixed as in repair complete all as specified and directed. |
| 54 | M&L for starting relay only suitable for window/split type Air Conditioner 1.5/2.0 TR capacity of any type or make fixed as in repair complete all as specified and directed. |
| 55 | M&L for thermostat suitable for window/split type Air Conditioner 1.5/2.0 TR capacity fixed as in repair complete all as specified and directed. |
| 56 | S & F Over load relay 3 Pole, 5 to 16 Amps suitable for split/window type Air Conditioner upto 2.0 TR fixed as in repair complete all as specified and directed. |
| 57 | S & F in replacement Condenser fan blade for split type AC/Window type A.C of any Capacity complete all as specified and as directed ..(Make as per site requirement.) |
| 58 | M&L for circuit kit of window type Air Conditioner complete with lugs, thimble and selector switch fixed as in repair complete all as specified and directed. |
| 59 | S & F in replacement remote control of existing make including battery for split/window /tower AC Cap 1.5/2 TR of make as per site requirement and replace of old one complete all as specified & as directed Please Enable Macros to View BoQ information |
| 60 | S & F in replacement remote control of existing make including battery for split/window /tower AC Cap 1.5/2 TR of make as per site requirement and replace of old one complete all as specified & as directed Please Enable Macros to View BoQ information |