| 1 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth, for foundation, etc in hard/dense soil and getting out complete all as specified and directed. |
| 2 | Returning, filling in, including spreading, leveling, watering and well ramming in layer not exc 25 cm with soil obtained from excavation all as specified and directed. |
| 3 | Removing excavated material (Soil) not exc 50 mtr and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed. |
| 4 | Taking out old un-serviceable GI pipes, laid in trenches or under floors or fixed to walls including all fittings and disconnecting from branch connections complete all as specified & directed, for 80mm bore of pipe complete all as specified and directed. |
| 5 | Taking out old un-serviceable GI pipes, laid in trenches or under floors or fixed to walls including all fittings and disconnecting from branch connections complete all as specified & directed, for 50mm bore of pipe complete all as specified and directed. |
| 6 | Taking out old un-serviceable GI pipes, laid in trenches or under floors or fixed to walls including all fittings and disconnecting from branch connections complete all as specified & directed, for 40mm bore of pipe complete all as specified and directed. |
| 7 | Taking out old un-serviceable GI pipes, laid in trenches or under floors or fixed to walls including all fittings and disconnecting from branch connections complete all as specified & directed, for 25mm bore of pipe complete all as specified and directed. |
| 8 | Taking out old un-serviceable GI pipes, laid in trenches or under floors or fixed to walls including all fittings and disconnecting from branch connections complete all as specified & directed, for 20mm bore of pipe complete all as specified and directed. |
| 9 | Supply and fixing in replacement of GI tubing, medium grade, ISI marked complete with all fittings, laid in trenches/floors GI pipes complete all as specified & directed, for 80mm bore of pipe complete all as specified and directed. |
| 10 | Supply and fixing in replacement of GI tubing, medium grade, ISI marked complete with all fittings, laid in trenches/floors GI pipes complete all as specified & directed, for 50mm bore of pipe complete all as specified and directed. |
| 11 | Supply and fixing in replacement of GI tubing, medium grade, ISI marked complete with all fittings, laid in trenches/floors GI pipes complete all as specified & directed, for 40mm bore of pipe complete all as specified and directed. |
| 12 | Supply and fixing in replacement of GI tubing, medium grade, ISI marked complete with all fittings, laid in trenches/floors GI pipes complete all as specified & directed, for 25mm bore of pipe complete all as specified and directed. |
| 13 | Supply and fixing in replacement of GI tubing, medium grade, ISI marked complete with all fittings, laid in trenches/floors GI pipes complete all as specified & directed, for 20mm bore of pipe complete all as specified and directed. |
| 14 | Taking down old unserviceable 100mm bore, CI water mains (including all fittings) with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and directed. |
| 15 | Taking down old unserviceable 150mm bore, CI water mains (including all fittings) with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and directed. |
| 16 | Supply and fixing of Ductile Iron pipe with spigot and socket ends, suitable for tyton joints, class K-7 laid in trenches, or under floors or fixed to walls, for 150mm bore of pipe complete all as specified and directed. |
| 17 | Supply and fixing of Ductile Iron pipe with spigot and socket ends, suitable for tyton joints, class K-7 laid in trenches, or under floors or fixed to walls, for 100mm bore of pipe complete all as specified and directed. |
| 18 | M&L for cutting of Road/PCC path, hard standing depth not less than 60cm and width not less than 45cm for laying water supply pipe and making good the existing surface with PCC (1:2:4) type B-2 of 150mm thick complete all as specified and directed by Engr-in charge |
| 19 | M&L for Cutting of existing CI/DI pipes and reducing to required length before laying in position for insertion of new tees,insert of D Joint branches etc complete all as specified & directed, for 200mm bore of pipe complete all as specified and directed. |
| 20 | M&L for Cutting of existing CI/DI pipes and reducing to required length before laying in position for insertion of new tees,insert of D Joint branches etc complete all as specified & directed, for 150mm bore of pipe complete all as specified and directed. |
| 21 | M&L for Cutting of existing CI/DI pipes and reducing to required length before laying in position for insertion of new tees,insert of D Joint branches etc complete all as specified & directed, for 100mm bore of pipe complete all as specified and directed. |
| 22 | M&L for Cutting of existing CI/DI pipes and reducing to required length before laying in position for insertion of new tees,insert of D Joint branches etc complete all as specified & directed, for 80mm bore of pipe complete all as specified and directed. |
| 23 | Supply and fixing CI Detachable Joint compleate nut bolts with superior quality Rubber ring set for 150 mm CI Pipe/DI Pipe complete all as specified & directed. |
| 24 | Supply and fixing CI Detachable Joint compleate nut bolts with superior quality Rubber ring set for 100 mm CI Pipe/DI Pipe complete all as specified & directed. |
| 25 | Supply and fixing CI Detachable Joint compleate nut bolts with superior quality Rubber ring set for 80 mm CI Pipe/DI Pipe complete all as specified & directed. |
| 26 | M&L for horizontal drilling, in any type of soil, using trenchless technology suitable for insertion of CI/GI/DI pipe of size 100mm bore for 20 to 80mm bore of pipe complete all as specified and directed. |
| 27 | M&L for horizontal drilling, in any type of soil, using trenchless technology suitable for insertion of CI/GI/DI pipe of size 150mm bore for 100mm bore of pipe complete all as specified and directed. |
| 28 | M&L for horizontal drilling, in any type of soil, using trenchless technology suitable for insertion of CI/GI/DI pipe of size 200mm bore for 150mm bore of pipe complete all as specified and directed. |
| 29 | Repair to existing damaged valve chamber of any size by PCC work using 20mm graded stone aggregete in coping/bed, finished even and smooth, rendering 15mm thick in cement mortar (1:6) internally and 10mm thick in cement mortar (1:4) externally, finished even and smooth without using extra cement incuding three coats of white wash including 2 mm thick MS sheet cover suitable with exsiting chamber fixed on 40mmx40mmx6mm thick angle iron frame ambeded in PCC coping with locking arrangement and mild steel hold fast & handle and duly painted with two coats of synthetic enamel paint over one coat of primer etc. as specified and directed by Engr-in-Charge. |
| 30 | S&F, in repair, Ductile iron sluice valve 150 mm dia with flanged ends class PN-1.6 with iron wheel, stainless steel spindle and check nut confirming to IS :780 including all jointing materials such as nuts, bolts, washers and gaskets etc. complete all as specified & directed . |
| 31 | S&F, in repair, Ductile iron sluice valve 100 mm dia with flanged ends class PN-1.6 with iron wheel, stainless steel spindle and check nut confirming to IS :780 including all jointing materials such as nuts, bolts, washers and gaskets etc. complete all as specified & directed . |
| 32 | S&F, in repair, Ductile iron sluice valve 80 mm dia with flanged ends class PN-1.6 with iron wheel, stainless steel spindle and check nut confirming to IS :780 including all jointing materials such as nuts, bolts, washers and gaskets etc. complete all as specified & directed . |
| 33 | M&L for DI Specials and fittinng as per IS for spigot and socketed DI pipes for water mains, branches, links such as bends(any type), reducers and angles, tappers any type, bends increasing/ decreasing or double sockets etc. Tee pieces, single branches, double branches (all socket and spigots) collers, cap and plug suitable for pipelines upto 250 mm bore complete all as specified and directed. |
| 34 | M&L in replacement of Gun metal gate valve of 50mm bore with iron wheel head, screwed both ends for iron pipe including testing complete all as specified and directed. |
| 35 | M&L in replacement of Gun metal gate valve of 40mm bore with iron wheel head, screwed both ends for iron pipe including testing complete all as specified and directed. |
| 36 | M&L in replacement of Gun metal gate valve of 25mm bore with iron wheel head, screwed both ends for iron pipe including testing complete all as specified and directed. |
| 37 | M&L in replacement of Gun metal gate valve of 20mm bore with iron wheel head, screwed both ends for iron pipe including testing complete all as specified and directed. |
| 38 | S&F in replacement of ball brass valves, high pressure, with polythene float and fly nut, screwed for iron pipe and fixed complete all as specified and directed for 25mm bore of pipe. |
| 39 | S&F in replacement of ball brass valves, high pressure, with polythene float and fly nut, screwed for iron pipe and fixed complete all as specified and directed for 20mm bore of pipe. |
| 40 | Attending CI/DI pipe 80 mm to 200 mm dia pipe line break downs in Joint Leakage pipe broken ,flange leakage including necessary arrangement Lead joint,gascuts ,nuts and bolts , excavation and returning filling all as specified and directed:- Note: fittings and pipes measured for separatly |
| 41 | S&F in repair ,mild steel sheets/plates of Fe-410-w (Gde-E-250) Quality -A(plain or chequered forming holes/welded to frame work as in valve pit cover complete all as specified and directed |
| 42 | S&F in repairs ,mild steel framed brackets of angles or tees web and flanges cut to shape, drilled and counter sunk for screw including bending and welding angles as necessary gasset plates riveting etc conforming to Fe-290 Gde-E- 165 complete all as specified and directed |
| 43 | Repair and servicing of sluice valve of 150mm incl renewal of perished rubber gasket, material washer,spindle, valves seating gland packing check nuts of gun metal, gun metal couplings washers, etc to make leak proof compleatly incl testing all as specified. |
| 44 | Repair and servicing of sluice valve of 100mm incl renewal of perished rubber gasket, material washer,spindle, valves seating gland packing check nuts of gun metal, gun metal couplings washers, etc to make leak proof compleatly incl testing all as specified. |
| 45 | Repair and servicing of sluice valve of 80mm incl renewal of perished rubber gasket, material washer,spindle, valves seating gland packing check nuts of gun metal, gun metal couplings washers, etc to make leak proof compleatly incl testing all as specified. |
| 46 | M&L for Drilling and tapping cast iron/DI water main ( in position ) for branch connection of 15 mm bore |
| 47 | M&L for Drilling and tapping cast iron/DI water main ( in position ) for branch connection of 20 mm bore |
| 48 | Material and labour for attending GI pipe 20 mm to 50 mm dia pipe line break downs in building/ground/terrace including necessary arrangement and safety measures minor repair/replacement of GI fittings such as union, nipple ,Elbow,socket Note: fittings cost shall be deemed in the quated rate . |
| 49 | Demolition of existing valve pit and M&L for construction of valve pit consisisting of 230mm thick, old size brick masonry wall in cement mortar (1:6), PCC (1:4:8) type D2, using 40mm graded stone aggregete as in fondation, PCC (1:2:4) type B1, using 20mm graded stone aggregete in coping/bed, finished even and smooth, rendering 15mm thick in cement mortar (1:6) internally and 10mm thick in cement mortar (1:4) externally, finished even and smooth without using extra cement incuding three coats of white wash and earth work in any type of soil and including 3mm thick MS sheet cover fixed on 40mmx40mmx6mm thick angle iron frame ambeded in PCC coping with locking arrangement and mild steel hold fast & handle and duly painted with two coats of synthetic enamel paint over one coat of primer etc. complete all as shown on drawing NO TD/2004/26 Sh 1/1 to 1/3 and as specified and directed for the following sizes:-(a) 1200mm x 1000mm x 1200mm |
| 50 | Demolition of existing valve pit and M&L for construction of valve pit consisisting of 230mm thick, old size brick masonry wall in cement mortar (1:6), PCC (1:4:8) type D2, using 40mm graded stone aggregete as in fondation, PCC (1:2:4) type B1, using 20mm graded stone aggregete in coping/bed, finished even and smooth, rendering 15mm thick in cement mortar (1:6) internally and 10mm thick in cement mortar (1:4) externally, finished even and smooth without using extra cement incuding three coats of white wash and earth work in any type of soil and including 3mm thick MS sheet cover fixed on 40mmx40mmx6mm thick angle iron frame ambeded in PCC coping with locking arrangement and mild steel hold fast & handle and duly painted with two coats of synthetic enamel paint over one coat of primer etc. complete all as shown on drawing NO TD/2004/26 Sh 1/1 to 1/3 and as specified and directed for the following sizes:-(b) 1200mm x 1000mm x 1000mm |
| 51 | Demolition of existing valve pit and M&L for construction of valve pit consisisting of 230mm thick, old size brick masonry wall in cement mortar (1:6), PCC (1:4:8) type D2, using 40mm graded stone aggregete as in fondation, PCC (1:2:4) type B1, using 20mm graded stone aggregete in coping/bed, finished even and smooth, rendering 15mm thick in cement mortar (1:6) internally and 10mm thick in cement mortar (1:4) externally, finished even and smooth without using extra cement incuding three coats of white wash and earth work in any type of soil and including 3mm thick MS sheet cover fixed on 40mmx40mmx6mm thick angle iron frame ambeded in PCC coping with locking arrangement and mild steel hold fast & handle and duly painted with two coats of synthetic enamel paint over one coat of primer etc. complete all as shown on drawing NO TD/2004/26 Sh 1/1 to 1/3 and as specified and directed for the following sizes:-(c) 1050mm x 750mm x 900mm Please Enable Macros to View BoQ information |