| 1 | Supply and laying sub class old 'B' burnt bricks laid as cable protection cover complete all as specified and directed. |
| 2 | Laying only sub class brunt bricks as cable protection cover all as directed. |
| 3 | Taking out sub class burnt bricks from the trenches and stacking at site serviceable /unserviceable bricks for reuse complete all as specified and directed. |
| 4 | Dismantling old unserviceable Steel poles/Rcc poles/struts, any size complete all as specified and directed. |
| 5 | M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws, type 410 SP-31 (09 Mtr long) including two coats of bituminous paint internally and externally for the portion embedded in concrete and two coats of aluminium paint over one coat of red oxide primer to external/exposed surfaces complete all as specified and directed . Note:- (i) Excavation/PCC will be measured and paid separately under relevant items (ii) writing letters pole no and figures in white enamel of black Roman, Italic or Indian of 10 cm height including circular back ground with black enamel paint of two coats incl white circular border over steel |
| 6 | M&L for painting of indoor/outdoor LT panel of any size with two coats of synthetic enamel grey colour paint after throughly scrapping/cleaning the rushed portion and fixing the LT panel door properly do the welding work if necessary and miscelleneous items complete all as specified and directed by Engr-in-Charge |
| 7 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for foundation of pole,laying of cables etc in Hard and dense soil and getting out. |
| 8 | Excavating in trenches not exceeding 1.5m wide and exceeding 1.5 m but not exceeding 3.00m in depth for foundation of pole, laying of cables etc in hard/dense soil and getting out. |
| 9 | Returning filling in including spreading, leveling, watering and well ramming in layer not exc 25 cm. |
| 10 | Removing excavated material not exc 50 mtr and depositing where directed at a level not exc. 1.5 m above the starting point. |
| 11 | M&L for providing dry river sand as in sand cushioning to UG cable including punning gently all as directed. Note : Depth after punning shall be measured and paid. |
| 12 | M&L for plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundtion of PCC poles/struts all as specified and directed. |
| 13 | M&L for plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundtion of pole/stay assembly etc including necessary form work, all as specified and directed. |
| 14 | M&L for plain cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate in foundtion of pole/stay assembly etc including necessary form work, all as specified and directed. |
| 15 | M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for padestal/coping around poles, including necessary form work, finishing even and smooth without using extra cement, all as specified and directed. |
| 16 | Taking out the existing PVC/XLPE, 1100 volts grade, LT UG electric cable of size 6 sqmm x 2 core with glands, cable protection pipes etc., complete from the trenches/fixed on wall removing the unserviceable fault cable and carefully stacking the serviceable cable for reusing all as specified and directed by the Engr-in- charge Note:- Excavation and Earth work shall be measured and paid separately under appropriate items all as per existing make |
| 17 | Taking out the existing PVC/XLPE, 1100 volts grade, LT UG electric cable of size 10 sqmm x 2/4 core with glands, cable protection pipes etc., complete from the trenches/fixed on wall removing the unserviceable fault cable and carefully stacking the serviceable cable for reusing all as specified and directed by the Engr-in- charge Note:- Excavation and Earth work shall be measured and paid separately under appropriate items all as per existing make |
| 18 | Taking out the existing PVC/XLPE, 1100 volts grade, LT UG electric cable of size 16 sqmm x 2/4 core with glands, cable protection pipes etc., complete from the trenches/fixed on wall removing the unserviceable fault cable and carefully stacking the serviceable cable for reusing all as specified and directed by the Engr-in- charge Note:- Excavation and Earth work shall be measured and paid separately under appropriate items all as per existing make |
| 19 | Taking out the existing PVC/XLPE, 1100 volts grade, LT UG electric cable of size 25/35 sqmm x 3.5 core with glands, cable protection pipes etc., complete from the trenches/fixed on wall removing the unserviceable fault cable and carefully stacking the serviceable cable for reusing all as specified and directed by the Engr-in- charge Note:- Excavation and Earth work shall be measured and paid separately under appropriate items all as per existing make |
| 20 | Taking out the existing PVC/XLPE, 1100 volts grade, LT UG electric cable of size 50 sqmm x 3.5 core with glands, cable protection pipes etc., complete from the trenches/fixed on wall removing the unserviceable fault cable and carefully stacking the serviceable cable for reusing all as specified and directed by the Engr-in- charge Note:- Excavation and Earth work shall be measured and paid separately under appropriate items all as per existing make |
| 21 | Taking out the existing PVC/XLPE, 1100 volts grade, LT UG electric cable of size 70 sqmm x 3.5 core with glands, cable protection pipes etc., complete from the trenches/fixed on wall removing the unserviceable fault cable and carefully stacking the serviceable cable for reusing all as specified and directed by the Engr-in- charge Note:- Excavation and Earth work shall be measured and paid separately under appropriate items all as per existing make |
| 22 | Taking out the existing PVC/XLPE, 1100 volts grade, LT UG electric cable of size 95 sqmm x 3.5 core with glands, cable protection pipes etc., complete from the trenches/fixed on wall removing the unserviceable fault cable and carefully stacking the serviceable cable for reusing all as specified and directed by the Engr-in- charge Note:- Excavation and Earth work shall be measured and paid separately under appropriate items all as per existing make |
| 23 | Re-Laying only in trenches/fixed on wall (or) passing through pipes/in floors, connecting up testing and commissioning of Serviceable PVC/XLPE , 1100 volts grade, LT UG electric cable of size 25 Sqmm x 3.5 core cable obtained vide item No 7 above all as per existing make comnplete all as specified and directed. |
| 24 | Re-Laying only in trenches/fixed on wall (or) passing through pipes/in floors, connecting up testing and commissioning of Serviceable PVC/XLPE , 1100 volts grade, LT UG electric cable of size 35 Sqmm x 3.5 core cable obtained vide item No 7 above all as per existing make complete all as specified and directed. |
| 25 | Re-Laying only in trenches/fixed on wall (or) passing through pipes/in floors, connecting up testing and commissioning of Serviceable PVC/XLPE , 1100 volts grade, LT UG electric cable of size 50 Sqmm x 3.5 core cable obtained vide item No 7 above all as per existing make complete all as specified and directed. |
| 26 | Re-Laying only in trenches/fixed on wall (or) passing through pipes/in floors, connecting up testing and commissioning of Serviceable PVC/XLPE , 1100 volts grade, LT UG electric cable of size 70 Sqmm x 3.5 core cable obtained vide item No 7 above all as per existing make complete all as specified and directed. |
| 27 | Re-Laying only in trenches/fixed on wall (or) passing through pipes/in floors, connecting up testing and commissioning of Serviceable PVC/XLPE , 1100 volts grade, LT UG electric cable of size 95 Sqmm x 3.5 core cable obtained vide item No 7 above all as per existing make complete all as specified and directed. |
| 28 | Supplying & laying, XLPE insulated PVC inner sheathed, 6 Sqmm, 2 core, armoured with galvanised steel strip heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed. |
| 29 | Supplying & laying, XLPE insulated PVC inner sheathed, 10 Sqmm, 2 core, armoured with galvanised steel strip heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed. |
| 30 | Supplying & laying, XLPE insulated PVC inner sheathed, 10 Sqmm, 4 core, armoured with galvanised steel strip heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed. |
| 31 | Supplying & laying, XLPE insulated PVC inner sheathed, 16 Sqmm, 4 core, armoured with galvanised steel strip heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed. |
| 32 | Supplying & laying, XLPE insulated PVC inner sheathed, 35 Sqmm, 3.5 core, armoured with galvanised steel strip heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed. |
| 33 | Supplying & laying, XLPE insulated PVC inner sheathed, 50 Sqmm, 3.5 core, armoured with galvanised steel strip heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed. |
| 34 | Supplying & laying, XLPE insulated PVC inner sheathed, 70 Sqmm, 3.5 core, armoured with galvanised steel strip heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed. |
| 35 | Supplying & laying, XLPE insulated PVC inner sheathed, 95 Sqmm, 3.5 core, armoured with galvanised steel strip heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed. |
| 36 | Supply and jointing straight through heat shrink joint kit for PVC/XLPE LT UG cable for cable of size 25/35 Sqmm 3.5 core complete all as specified and directed. |
| 37 | Supply and jointing straight through heat shrink joint kit for PVC/XLPE LT UG cable for cable of size 50 Sqmm 3.5 core complete all as specified and directed. |
| 38 | Supply and jointing straight through heat shrink joint kit for PVC/XLPE LT UG cable for cable of size 70/95 Sqmm 3.5 core complete all as specified and directed. |
| 39 | S&F, in repair, GI pipe 80mm bore, light grade, laid below road / fixed along the poles / walls with necessary clamping, etc complete all as per specified and directed. |
| 40 | S&F, in repair, GI pipe, 40mm bore, light grade, laid below road/fixed along the poles / walls with necessary clamping, etc complete all as per specified and directed. |
| 41 | M&L Painting to steel tubular poles LT of 8.5/9Mtr long incl fittings and fixtures complete, fixed with poles with one coat of alluminium paint incl scrapping of rusts and preparation of surfaces and writing Numberfrom white enamel paint of 10 cm height including circular back ground with black enamel paint of two coats incl white circular border over steel/RCC surfaces of electric poles.etc., complete all as specified and as directed by Engr-in-Charge. |
| 42 | Supply and fix LT junction box for street light, FRP type with hinged type door and locking arrangement, off white colour, of size 300 x 200 x 105mm (internal) comprising of suitable size Aluminium busbar 3 rows with terminals,1 No bakelite base neutral link and 01 No earthing terminal bolt and nut and connecting up cables with aluminium terminal lugs all as specified and as directed . |
| 43 | S&F, in repair, PVC junction box, factory made, size 180x290x110mm with one No SP MCB of 06 Amp rating, class-B and 3 Nos connector fixed on pole with necessary clamps and bolts etc and connecting with street light cable including taking dowo old complete all as specified and directed. |
| 44 | S&F, in repair, FRP insulated and PVC sheathed copper conductor cable of size 1.5 Sqmm, 3 core, 1100 volts grade, multistranded, passing throuth existing pipe, fixed on pole/wall from juntion box to street light fitting complete all as specified and directed. including taking down old |
| 45 | S&F, in repairs, bracket made out of light grade, Galvanised steel tube, 35mm bore, 1.2 Mtr length, bent to 120 degree for fixing street light fitting at the top, fixed to pole with necessary clamps made out of FI 40mm x 4mm with nuts & bolts including preparation of steel surfaces & apply two coat of synthetic enamel paint over red oxide prime rincluding taking dowo old complete all as specified and directed. |
| 46 | S&F, in repairs, bracket made out of light grade, Galvanised steel tube, 40mm bore, 1.2 Mtr length, bent to 120 degree for fixing street light fitting at the top, fixed to pole with necessary clamps made out of FI 40mm x 4mm with nuts & bolts including preparation of steel surfaces & apply two coat of synthetic enamel paint over red oxide prime rincluding taking dowo old complete all as specified and directed. |
| 47 | S&F, in repair, Round circular of 40mm dia light grade GI pipe dia meter of circle not less then 1.5m suitable for fixing in top of 9 meter steel tubler pole with all nuts bolts , clamp,cross chanel and circular cap for fixing of pole suitable for fixing three nos flood light all as specified and directed |
| 48 | Taking down existing LED light fitting 25/45/70/90 W from LT poles ,cleaning of prismatic polycarbonate cover, remove the corban and reconected to ACSR conductor by using new aluminium service wire 2.0 mm from conductor to LED street light all as specified and directed |
| 49 | Taking down and refixing existing LED light fitting from LT poles, removed LED driver and ,Supply & fix new electronic driver assembly for LED street light fitting of 35 watt all as specified and directed |
| 50 | Taking down and refixing existing LED light fitting from LT poles, removed LED driver and ,Supply & fix new electronic driver assembly for LED street light fitting of 45 watt all as specified and directed |
| 51 | Taking down and refixing existing LED light fitting from LT poles, removed LED driver and ,Supply & fix new electronic driver assembly for LED street light fitting of 70 watt all as specified and directed |
| 52 | Taking down and refixing existing LED light fitting from LT poles, removed LED driver and ,Supply & fix new electronic driver assembly for LED street light fitting of 95 watt all as specified and directed |
| 53 | Supply, installation, commissoning and testing, in repair street light timer panel along with Conforms to IS/IEC 60947-4-1, Provided with Protection Degree IP 54 Extended wide band coil FRLS (Fire retardant low smoke) Internal wiring In-built Short-Circuit Protection with Digital 24 hour timer-01 no,Contactor Rating (A) 32 / TP40 / TPN-01no as per havells Cat part no IHXTS03060 or equivalent to L&T/ C&S/ ABB all as specified and directed |
| 54 | Supply, installation, commissoning and testing, in repair street light Time switch analog time switch,with Conforms to single phase, 230 volts with 24 hours time setting, current rating 16 Amps as per Havells, ABB/ Seimens/ C&S |
| 55 | Supply, installation, commissoning and testing, in repair street light AC relay type ML-3 and with MCB TPN, C curve 32 Amp, three phase,Make Havells/ L&T/ABB/ or equivalent to other make all as specified and directed |
| 56 | Taking down and refixing existing LED light fitting from bolard light , removed LED driver and ,Supply & fix new electronic driver assembly for LED bolard light fitting of 5 to 10 watt all as specified and directed |
| 57 | S& F 25 cm dia garden dome light with milky colour unbreakable PVC holder type B22 with out LED Bulb water proof fixed on existing GI pipe with same shape all as directed by Engr-in-Charge including taking down old |
| 58 | S&F LED Solar street light fitting battery suitable for 25 Watt with high efficiency ,lithium ferro phosphate battery with in built ,all as fixing as existing light complete all as specified and directed .make Havells/ bajaj/philips or equivalent |
| 59 | Supply and fixing path directional reflector with PC diffuser and aluminium power coated bollard provided uniform illumination for pathways LED type 9 watt 230 watt volts AC outdoor type with decorativepost for 360 degree indirect light IP 65 protectionwith impact and corrosion resistant complete withdriver and lamp including taking down old one complete complete.make havells/ Bajaj/Chrompton /wipro / Philips |
| 60 | Supply and fixing post top lantern LED type 20watt 230 watt volts AC outdoor type with decorativepost top for 360 degree indirect light IP 65 protectionwith impact and corrosion resistant complete withdriver and lamp including taking down old one complete.make havells cat part CORALMINIPT25WLED 757PSYMTOPC or equvalent Bajaj/Chrompton /wipro / Philips |
| 61 | S&F, in repair, LED flood light luminaire of 210watts with high pressure die cast housing with IP-66, power coated with gray colour finish, prismatic polycarbonae cover with LED lenses complete all as including taking down old Make - Bajaj or Chrompton/Havells/Philips all as specified and directed. |
| 62 | S&F, in repair, LED flood light luminaire of 170watts with high pressure die cast housing with IP-66, power coated with gray colour finish, prismatic polycarbonae cover with LED lenses complete all as including taking dowo old Make - Bajaj or Chrompton/Havells/Philips all as specified and directed. |
| 63 | S&F, in repair, LED flood light luminaire of 120 watts with high pressure die cast housing with IP-66, power coated with gray colour finish, prismatic polycarbonae cover with LED lenses complete all as including taking dowo old per Make - Bajaj or Chrompton/Havells/Philips as all specified and directed |
| 64 | S&F, in repair, LED flood light luminaire of 100 watts with high pressure die cast housing with IP-66, power coated with gray colour finish, prismatic polycarbonae cover with LED lenses complete all as including taking dowo old per Make - Bajaj or Chrompton/Havells/Philips as all specified and directed |
| 65 | S&F, in repair, LED flood light luminaire of 50 watts with high pressure die cast housing with IP-66, power coated with gray colour finish, prismatic polycarbonae cover with LED lenses complete all as including taking dowo old per Make - Bajaj or Chrompton/Havells/Philips as all specified and directed |
| 66 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant including taking dowo old complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete withIP 66 protection |
| 67 | Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant including taking dowo old complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete withIP 66 protection |
| 68 | Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant including taking dowo old complete with driver, lamp bracket with impactand corrosion resistant including thermalmanagement in multiple optics complete withIP 66 protection complete |
| 69 | Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant including taking dowo old complete with driver, lamp bracket with impactand corrosion resistant including thermalmanagement in multiple optics complete withIP 66 protection complete |
| 70 | M&L, in repairs, earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth strip of 25x4mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SSR Part I connected to earth test point using earth strip of 25x4mm as earth lead all as specified and testing on completion including provision of earth lead protected by 40 mm dia light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work in any type of soil, PCC pit with RCC cover, char coal, salt, funnel etc complete. Note : Rate quoted by tenderers shall be deemed to include for following provisions;-[i]. Excavation & earth work in any type of soil including removing of surplus material upto 50 M.[ii]. PCC 1:3:6 type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC 1:2:4 type B1 cover 50x50 cm with 8mm TMT bars @ 10 cm C/C both ways with handles.[iii]. Main earthing strip from earth electrode to test point upto 7.5 mtr.[iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs, charcoal & salt as reqd.[v]. GI protection pipe of size 40 mm bore light grade 7.5m. |
| 71 | Disconnecting the existing Unserviceable MCCB, taking out from the panel board and replace by S&F new MCCB 4 pole, 250 Amps, 35/36 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, thermal & adjustable magnetic setting, fixed in existing panel and connecting with existing cable, including nuts bolts and washer etc complete all as specified and directed. |
| 72 | Disconnecting the existing Unserviceable MCCB, taking out from the panel board and replace by S&F new MCCB 4 pole, 200 Amps, 36 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, thermal & adjustable magnetic setting, fixed in existing panel and connecting with existing cable, including nuts bolts and washer etc complete all as specified and directed. |
| 73 | Disconnecting the existing Unserviceable MCCB, taking out from the panel board and replace by S&F new MCCB 4 pole, 160 Amps, 36 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, thermal & adjustable magnetic setting, fixed in existing panel and connecting with existing cable, including nuts bolts and washer etc complete all as specified and directed. |
| 74 | Disconnecting the existing Unserviceable MCCB, taking out from the panel board and replace by S&F new MCCB 4 pole, 125 Amps, 36 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, thermal & adjustable magnetic setting, fixed in existing panel and connecting with existing cable, including nuts bolts and washer etc complete all as specified and directed. |
| 75 | Disconnecting the existing Unserviceable MCCB, taking out from the panel board and replace by S&F new MCCB 4 pole, 100 Amps, 25 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, thermal & adjustable magnetic setting, fixed in existing panel and connecting with existing cable, including nuts bolts and washer etc complete all as specified and directed. |
| 76 | Disconnecting the existing Unserviceable MCCB, taking out from the panel board and replace by S&F new MCCB 4 pole, 63 Amps, 16 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, thermal & adjustable magnetic setting, fixed in existing panel and connecting with existing cable, including nuts bolts and washer etc complete all as specified and directed. |
| 77 | Disconnecting the existing Unserviceable MCCB, taking out from the panel board and replace by S&F new MCCB 3 pole, 200 Amps, 35 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, thermal & adjustable magnetic setting, fixed in existing panel and connecting with existing cable, including nuts bolts and washer etc complete all as specified and directed. |
| 78 | Disconnecting the existing Unserviceable MCCB, taking out from the panel board and replace by S&F new MCCB 3 pole, 160 Amps, 36 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, thermal & adjustable magnetic setting, fixed in existing panel and connecting with existing cable, including nuts bolts and washer etc complete all as specified and directed. |
| 79 | Disconnecting the existing Unserviceable MCCB, taking out from the panel board and replace by S&F new MCCB 3 pole, 125 Amps, 25 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, thermal & adjustable magnetic setting, fixed in existing panel and connecting with existing cable, including nuts bolts and washer etc complete all as specified and directed. |
| 80 | Supply, installation, commissoning and testing, in repair, feeder pillar board, Compartment type, LT(415 Volts, 50 Hz , 3-phase, 4 wire supply) plinth mounted, factory made, outdoor type, weather and vermin proof (Protection Class IP-54) made out of 50m x 50mm x 5mm angle iron frame and 3.15 mm thick MS Sheet CRCA sheet powder coated with front & back hinged opening, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enemell gray paint (First Quality) over a coat of red oxide primer, grouting panel through angle iron 0.45 mtr in ground and 0.3 mtr over the ground including excavation & earth work in any type of soil and PCC (1:3:6) type C-2 using 40mm graded stone aggregate complete comprising of the followings:- (a) Incoming supply:- (i) Aluminium bus bar chamber 250 amps rating of 04 strip - 01 No (ii) MCCB, thermal and meganitic setting, 4 pole AC 415volts, 160 Amp rating, 36 KA rupturing capacity - 01 No (iii) Digital type voltmenter 0-500 V with selector switches - 01No (iv) Digital type Amp meter 0-300A with selecter switch with CT ratio 300/5 - 01 No (v) Indicatiing lamp Neon type for R-Y-B - 3 Nos (b) Outgoing supply:- (i) MCCB, thermal and meganitic setting, 4 pole AC 415volts, 125 Amp rating, 36 KA rupturing capacity - 02 No (ii) MCCB, thermal and meganitic setting, 4 pole AC 415volts, 100 Amp rating, 25 KA rupturing capacity - 01 No.(iii) MCCB, thermal and meganitic setting, 4 pole AC 415volts, 63 Amp rating, 25 KA rupturing capacity - 03 No. |
| 81 | Supply, installation, commissioning and testing, feeder piller board, compartment , LT (415 Volts, 50 Hz , 3-phase, 4 wire supply), plinth mounted, factory made, outdoor type, weather and vermin proof made out of angle iron frame and 3.15 mm thick MS Sheet CRCA sheet powder coated with front & back hinged opening, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel gray paint (First Quality) over a coat of red oxide primer, grouting panel through angle iron, 0.2 mtr in ground and 0.30 mtr over the ground including excavation & earth work in any type of soil and PCC complete comprising of the followings:- (a) Incoming supply:- (i) Aluminium bus bar 240 amps rating of 04 strip having suitable whole with nuts and bolts (ii) MCCB 160 Amps, 04 pole 415 Volt 36 KA rupturing capacity-01 No, (iii) MCCB 125 Amp, 04 pole, 415 Volts 36 KA rupturing capacity-02 Nos (iii) MCCB 63 Amp, 04 pole, 415 Volts25 KA rupturing capacity-04 Nos (iV) MCB 40 Amp, 02 pole, 230 Volts-02 Nos(v) Digital type multifunctional meter showing A, V, Hz etc with suitable CT ratio -1No (vi) Indicating lamp Neon type for R-Y-B - 3 Nos. |
| 82 | S&F, in repair, shunt capacitor 20 KVAR capacity for improvement of power factor bank,including taking down old complete all as specified and as directed. |
| 83 | S&F, in repair, shunt capacitor 10KVAR capacity for improvement of power factor bank,,including taking down old complete all as specified and as directed. |
| 84 | S&F, in repair, shunt capacitor 5 KVAR capacity for improvement of power factor bank,,including taking down old complete all as specified and as directed. |
| 85 | M/L for trimming of branches of trees touching LT electric over head line and making clear about 3 mtr in radius by climbing up tree or by providing ladder, at a height of 9 mtr and above and carrying and depositing where directed not exceeding 50 mtr.Note : (i) Necessary T & P items arrange by contractor. (ii) While cutting the tree branches the fallen branch damaged the contactor, insulator, pole the contractor should be replaced the said items without any extra cost.(ii) Cutting of tree consider in each span only not no of tree in one span have 10 trees it consider only one span. |
| 86 | S&F, in repair, shunt capacitor 2 KVAR capacity for improvement of power factor bank,,including taking down old complete all as specified and as directed. |
| 87 | M&L for cutting of Road/PCC path, hard standing depth not less than 60cm and width not less than 45cm for laying water supply pipe and making good the existing surface with PCC (1:2:4) type B-2 of 150mm thick complete all as specified and directed by Engr-in charge Please Enable Macros to View BoQ information |