| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kind of soil |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. Ordinary Rock |
| 3 | Dumping stone including cost of stones.in Horizontal on level |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 5 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished 40 mm thick with 20 mm nominal size stone aggregate |
| 6 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 7 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) |
| 8 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level ::1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 9 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 10 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 11 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns etc. for mass concrete. |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, pillars, piers, abutments, posts and struts. |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platforms |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 17 | Providing & fixing upto floor five level precast cement concrete solid blocks including hoisting and setting in position in cement mortar 1:3 (1cement:3 coarse sand), cost of required centring, shuttering and curing complete 1:3:6 (1 cement : 3 coarse sand : 6 graded crushed stone aggregate 20 mm nominal size) |
| 18 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class Kail wood |
| 19 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.Second class Kail wood |
| 20 | Providng & fixing of Float glass panes 4 mm thick glass pane (weight not less than 10kg/sqm)., with wooden fillets wherever required complete |
| 21 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately)Second class teak wood 30 mm thick shutters |
| 22 | Providing and fixing traditionally carved wood work (Shingstak) over doors and windows including all accessories as per the direction of the Engineer in-charge, complete with;Budloo wood |
| 23 | 15mm Cement plaster on the rough side of single or half brick wall of mix:1 : 4 ( 1 cement : 4 fine sand) |
| 24 | 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) |
| 25 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 26 | Finishing walls with textured exterior paint of required shade : 13.45.1 New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 27 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 13.62.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 28 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit. |
| 29 | Providing & fixing 12mm thick ready made wooden flooring incl 1mm thick thermocol incl placeing in position complete job.(AC-4). |
| 30 | Providing and fixing 12mm thick ply board with 4\\" width plank tongued and grooved, incl. placing in position complete job. |
| 31 | Wiring for light point 6amp socket/exhaust fan point / call bell point /with 1.5 Sq.mm PVC FR insulated copper conductor single core in surface/recessed medium class PVC conduit, suitable size MS box and earthing the point with 0.75 Sq.mm. FR PVC insulated copper conductor single core cable as required. |
| 32 | Wiring for 16amp socket outlet with 2.5mm FR PVC insulated copper conductor cable in existing recessed PVC conduit , including sheet as required. |
| 33 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire |
| 34 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 x 4 sq. mm + 1 x 4 sq. mm earth wire |
| 35 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 4 x 6 sq. mm + 2 x 4 sq. mm earth wire |
| 36 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2x 10 sq. mm + 1 x 6 sq. mm earth wire |
| 37 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2x 16 sq. mm + 1 x 6 sq. mm earth wire |
| 38 | Providing & Fixing of IP40 LED Recessed / Surface Mounted, Round / Sqaure Non-Dimmable Back lit SMD Mid Power LED Downlight with die-cast aluminum housing & Heat Sink for heat dissipation with UV Stabilized non yellowish Diffuser with internal/ external BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% and in compliance to IEC standards. System Lumen efficacy of ≥ 120 lm / watt, THD < 10 % ,p.f.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. 15W CEILING MOUNTED LED LIGHT |
| 39 | Providing & Fixing of IP40 LED Recessed / Surface Mounted, Round / Sqaure Non-Dimmable Back lit SMD Mid Power LED Downlight with die-cast aluminum housing & Heat Sink for heat dissipation with UV Stabilized non yellowish Diffuser with internal/ external BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% and in compliance to IEC standards. System Lumen efficacy of ≥ 120 lm / watt, THD < 10 % ,p.f.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. 12 W CEILING MOUNTED LED LIGHT |
| 40 | Supply installation/testing and commissioning of LED flood light 50W with complete accessories (Make Havells/Philips/Panasonic/Syska/Gold medel) |
| 41 | P/F of exhaust fan shutter type of sweep 250mm in the existing opening, including making the hole to suit the above fan, making good the damage as required.(Make: Havells USHA/Bajaj) |
| 42 | S/F of 1200mm sweep 3 blades,energy efficient 5 star ceiling fan complete with assembling of blades,down rod,shackle insulator,canopy etc,including 2 modular stepped type modular fan rugulator. (Make: Havells/Crompton/Orient/USHA) |
| 43 | S/F following size/module, GI box along with modular base and cover plate for modular switches/sockets in recess etc. as require (Make: Havells Crabtree/Legrand/Greatwhite/CONA/Gold medel) 1 or 2 Module (75 mmX75 mm) |
| 44 | S/F following size/module, GI box along with modular base and cover plate for modular switches/sockets in recess etc. as required: (Make: Havells Crabtree/Legrand/Greatwhite/CONA/Gold medel) 3 Module (100mmX75mm) |
| 45 | S/F following size/module, GI box along with modular base and cover plate for modular switches/sockets in recess etc. as required: (Make: Havells Crabtree/Legrand/Greatwhite/CONA/Gold medel) 4 Module (125mmX75mm) |
| 46 | S/F following size/module, GI box along with modular base and cover plate for modular switches/sockets in recess etc. as required: (Make: Havells Crabtree/Legrand/Greatwhite/CONA/Gold medel) 6 Module (200mmX75mm) |
| 47 | S/F following modular switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required. (Make: Havells Crabtree/Legrand/Greatwhite/CONA/Gold medel) 6/10 A switch |
| 48 | S/F following modular switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required. (Make: Havells3 pin 5/6 A socket outlet 6/10 A switch |
| 49 | S/F following modular switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required.(Make: Havells Crabtree/Legrand/Greatwhite/CONA/Gold medel) 15/16 A switch |
| 50 | S/F following modular switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required. (Make: Havells Crabtree/Legrand/Greatwhite/CONA/Gold medel) 6 pin 15/16 A socket outlet |
| 51 | S/F following modular switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required. (Make: Havells3 pin 5/6 A socket outlet indicator lamp |
| 52 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 16 Way double door SP&N |
| 53 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 8 WAY (2+24) TPN MCB Board |
| 54 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 12 way double door SP&N |
| 55 | S/F of 5 Amps to 63 Amps, 240/415V, “B series, ISI Mark” miniature circuit breakers suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required: (Make: Havells/C&S/V Guard) single pole 6/10 A, DP MCB |
| 56 | S/F of 5 Amps to 63 Amps, 240/415V, “B series, ISI Mark” miniature circuit breakers suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required: (Make: Havells/C&S/V Guard) Single pole 16/20 A, DP MCB |
| 57 | S/F of 5 Amps to 63 Amps, 240/415V, “B series, ISI Mark” miniature circuit breakers suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required: (Make: Havells/C&S/V Guard)Double pole 40A DP MCB |
| 58 | S/F of 5 Amps to 63 Amps, 240/415V, “B series, ISI Mark” miniature circuit breakers suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required: (Make: Havells/C&S/V Guard) Double pole 63A DP MCB |
| 59 | S/F of 5 Amps to 63 Amps, 240/415V, “B series, ISI Mark” miniature circuit breakers suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required: (Make: Havells/C&S/V Guard)Four pole 63A, TPN |
| 60 | S/F of 5 Amps to 63 Amps, 240/415V, “B series, ISI Mark” miniature circuit breakers suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required: (Make: Havells/C&S/V Guard)Four pole 100A, TPN |
| 61 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25mm |
| 62 | Supplying and fixing of MS fan box |
| 63 | Supplying and fixing of 10 x 10 x 10 Cm of Concealed box |
| 64 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. |
| 65 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 66 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 67 | Supply/installation/testing & commissioning of 4 pair UTP CAT-6 Cable in PVC Conduit.the cable should be tested upto 350MHZ and cable should have ripcord for easy strip ability |
| 68 | Supply & fixing of Computer jack/Ethernet outlet unit (RJ 45) including making the connection as required |
| 69 | Supply and laying of Cat 6 data cable existing conduit complete as required |
| 70 | Supply and fixing of a 10amp 240 volt single pole grid plate mounted switch indicator with molded copper plate including recessed 2 inch M.S box complete as required including connection. |
| 71 | Supply and fixing of combined 3 pin 240 volt 10amp socket outlet with safety shutter and 10amp 240 volt single pole mounted in recessed including M.S box complete as required |
| 72 | Supply and fixing of combined 3 pin 240 volt 10amp socket outlet with safety shutter and 20amp 240 volt single pole mounted in recessed including M.S box complete as required |
| 73 | Supply and fixing of following single pole and neutral sheet steel MCB distribution board 240 volt on surface recess complete with tinned busbar neutral link earth bar, tin bar, detachable glaud plates, double door interconnected including pointing etc as required 16 way double door SPN. |
| 74 | 8 modular plate |
| 75 | 12 modular plate |
| 76 | Ceiling fan regulator |
| 77 | Providng & fixing of Changeover of required specificatioon comnplete job |
| 78 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 79 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 80 | Providing and fixing vitreous china dual purpose closet suitable for use as squatting pan or European type water closet (Anglo Indian W.C pan) with seat & lid fixed with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets, 40 mm flush bend, 20 mm over flow pipe, with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: 17.68.1 White vitreous china dual purpose WC pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.P. flush bend. |
| 81 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests. |
| 82 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357mm |
| 83 | Providing and fixing C.P Brass toilet paper holder |
| 84 | Providing and fixing of Soap Dish (C.P Brass) with brackets etc |
| 85 | Providing and fixing brass bib cock of approved quality. 15mm nominal bore. |
| 86 | Providing and fixing flow trap of PVC . |
| 87 | Providing and fixing floor jail. |
| 88 | Providing and fixing soil, waste and vent pipes 110mm dia PVC. |
| 89 | Providing and fixing soil, waste and vent pipes 90mm dia PVC. |
| 90 | Providing and fixing of PPR pipe complete with PPR fitting and damps including cutting and making good the walls etc internal complete. 25mm |
| 91 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and color. 600 mm long towel rail with total length of 645 mm, 78 mm wide and effective height of 88 mm, weighing not less than 190 gms. |
| 92 | Providing and fixing of plain bends of required degree.110mm dia PVC. |
| 93 | Providing and fixing of plain bends of required degree.90mm dia PVC. |
| 94 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 95 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 96 | Marble Stone tile work for wall lining upto 10 m height with special adhesive over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shade.Raj Nagar plain white marble/ Udaipur green marble/ Zebra black marble |
| 97 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 98 | Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundations etc. in layers not exceeding 20cm in depth, consolidating eachdeposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 99 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 gradedstone aggregate 20 mm nominal size derived from natural sources) |
| 100 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer including welding and bolting with special shaped washers trusses etc. complete. Hot finished welded type tubes |
| 101 | Providing corrugated G.S. sheet roofing including vertical curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diametre with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins,rafters and trusses and including cuttingto size and shape wherever required. 0.80 mm thick with zinc coating not less than 275 gm/m2 |
| 102 | Carriage of Cement from average lead upto 5 km by mechanical transport |
| 103 | Carriage of sand and course aggregate from average lead upto 10 km by mechanical transport |
| 104 | Carriage of stone from average lead upto 3 km by mechanical transport Please Enable Macros to View BoQ information |