| 1 | Taking down chowkats or frames n.exc 1.50 sqm each, without taking off shutters from the frames including iron mongry. |
| 2 | Taking down of shutters of any description of area exc 1.00 sqm but n. exc 2.00 Sqm each |
| 3 | S&F 35 mm thick Glazed and skeleton shutters 2nd class hard wood, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats |
| 4 | S & F Plain, framed, panelled shutters 35 mm thick in 2nd class hard wood (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats |
| 5 | S&F factory made single extruded WPC (wood polymer Composite) solid door/ window/ Ceosetory window & other Frames/ Chowkhat of size 45 x 70 mm comprising of PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wwod powder/ rick husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms ) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded stat headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N / mm 2 and resistance to spread of flame of Class A catogory with property of being termite/ borer proof, water / moisture proof and fire retardant and fixed in position with MS hold fast/lugs / SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note:- For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 6 | S&F factory made single extruded WPC (wood polymer Composite) solid plain flush door shutter of 30 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/ cum and screw withdrwal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N mm2 modulus of elasticity 850 N / mm2 and resistance to spread of flame of Class A catogary with property of being termite/ borer proof, water/ moisture proof and fire retardanat and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, all as per direction of Engineer-In-Charge |
| 7 | S & F butt hinges, medium weight cold rolled 100mm size, complete. |
| 8 | S&F 150mm long aluminium anodized, barrel tower bolt of extruded section complete. |
| 9 | S&F 200mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy all as specified. |
| 10 | S&F Anodised aluminium alloy handles cast type, each 150mm long |
| 11 | Dismantling of wall and ceiling boards (fiber, pulp, insulation etc,) or insulation boards/slabs/blankets, any thickness including cover fillet complete all as specified and directed. |
| 12 | S&F Powder coated aluminium anodised snap grid system of grid size 600 X 600 mm fixed to walls with rawl plugs and screws and hang to roof members with 2 mm dia GI wire comprising of the Main Tee 28x24x3mm thick, Cross Tee 28x24x3mm thick and Wall angle 24x24x3mm thick sections complete all as specified and directed. |
| 13 | S&F 4 mm thick Everest designer ceiling (E-board classic) board / tiles for insulation and accoustic purpose, 595 X 595 mm size fixed with staples on GI/Aluminium snap grid as in ceiling with and including dusting of surface and applying two coats of oil bond distemper over a coat of primer complete all as specified and directed |
| 14 | S&F 6mm thick decorative PVC Sheet hollow (design approved by GE) for insulation and acoustic purpose on wall/ceiling surface, screw to timber frame work for levelling of wall as reqd, including with panelling to vertical surfaces, fixed with rawl plug and screws complete all as specified and directed |
| 15 | Dismantling laid dry or laid dry and pointed Stone slabs and tiles of any description or thickness in floors, aprons etc. |
| 16 | M & L Machine cut Kota stone slab flooring 20-25mm thick over and including cement screed base 20mm thick in cement mortar 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 17 | Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including 15mm thick rendering in CM 1:3 including rubbing and polishing. |
| 18 | S&F in repairs 600 mm x 450 mm beveled edge mirror of selected quality glass 5.5mm thick mounted on 6mm thick AC building board or commercial plywood & fixed with wooden plugs with chromium plated brass screws and washer and aluminum beading complete all as directed. |
| 19 | S & F in repairs, Aluminum die cast body door closer hydrau lically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete. |
| 20 | M&L for preparation of old painted wooden surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint ,complete all as spd and directed. |
| 21 | S & F 5.50mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.50 Sqm in each pane with hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beadsall as specified and as directed. |
| 22 | S&F in repair, Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, all as specified and directed. |
| 23 | S&F in repairs of 20mm dia harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. |
| 24 | S&F in repairs tubular towel rail brass chromium plated 20mm dia D type 60cm long complete all as directed. |
| 25 | S&F in repair, 1000 ltrs capacity white colour three layer rotational moulded polythene water storage tank (Cylinderical vertical with closed top) hoisted and fixed in position with 20mm bore dia ball vallves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed, (Minimum weight 20 mm- 210 gms/ 25mm-455gms/ 40mm - 690 gms) , all as specified in SSR Part-I, complete including dismantling of existing tank. |
| 26 | S&F in repair 10 ltr capacity PVC valveless,syphonic action type, flushing cistern, low level, white, with inlet ball valve , float and handle including brackets, complete all as specified and directed. |
| 27 | M&L for sunken floor treatment as under:- (i) The sunken portion shall be tested for leakage / seepage / dampness by ponding with water for 72 hours. In case any defect is noticed, the defective portion shall be grouted with cement slurry mixed with suitable chemical & tested again. The process of grouting and testing shall be repeated till leakage/ seepage/ dampness is eliminated.(ii) Demolition of cement concrete of any description and in any position not otherwise specifically provided for in any type of filling in sunken portion & cleaned the sunken potion including vertical wall surface complete all as directed.(iii)Laying of 40mm thick (Min) PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate with integral water proofing compound as per manufacturer instructions on bottom of sunken portion with proper slope towards spout. Vertical sides shall be plastered in CM (1:3), 15 mm thick mixed with water proofing compound as per manufacturer instructions. Plaster shall be extended over PCC coving when the same is green i.e. PCC & plaster be carried out at the same time complete all as specified and directed.(iv) After laying sewage/ plumbing pipes with fixtures in position, 2 coats of OMIPLAS EP-101 epoxy compound shall be applied complete all as specified and directed.(v) Testing again of water tightness by ponding for 72 hours & rectifying defects if any till total elimination of defects complete all as specified and directed.(vi) M&L to fill the sunken floor with PCC ( 1:5:10) type E-2 using 40mm graded brick aggregate over the treated surface complete all as specified and directed.(vii) Provinding spouts of 25mm dia GI pipe light grade projecting 450mm from clear outer suraface of wall with mosquito proof cap on inner face of pipe shall be provided to drain out seepage water, including cutting holes and making good if needed complete all as specified and directed. |
| 28 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as directed. |
| 29 | M & L 15mm thick screed bed in cement mortar 1:6 under floor tiles, all as specified and directed |
| 30 | M&L for Heavy duty tiles exterior grade 300 x 300 x 10mm in CM 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match |
| 31 | M & L Anti skid Ceramic coloured tiles of size 600x600x7-8mm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles laid on, as specified. |
| 32 | M & L Anti skid Ceramic coloured tiles of size 400x400x7-8mm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles laid on, as specified. |
| 33 | M & L Glazed ceramic coloured tiles in vertical surface 450x300x7-8mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick rendering in CM 1:4 etc. |
| 34 | Demolition brick work or stone/ boulder masonery built in cement mortar including all quoins , pillars etc complete all as specified and directed. |
| 35 | M&L for brick work using sub class ‘B’ old size bricks, straight or curved on plan exceeding 6m mean radius, built in CM (1:6) |
| 36 | M & L Precast cement concrete block masonry with solid blocks PCC Type C1 (1:3:6) (using 20mm graded aggregate) exc 10cm in width and setting in CM 1:6 |
| 37 | Taking down cement or cement lime plaster of any description on brick or stone walls, etc. including racking out joints, hacking for key, scrubbing down with water etc.&removing rubbish to a distance not exc 250m |
| 38 | M&L for rendering 15 mm thick Readymade plaster on inner/outer walls with READIPLAST by adding 17-19% of potable water by weight of material. for thickness above 15mm, it is recommended to be applied in multiple layers. Ready mix plaster shall complies with IS 1661-1972, IS 2250-1965, IS 2402-1963 and confirms the Compressive strength @ 28 days- 10-12 Mpa/Bulk density-1500-1600 kg/cum. Note : The rate quoted by the contractor shall include cleaning of surface, application as per instruction and scaffolding upto 10 mtr height, all as specified and directed. |
| 39 | S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, all as specified and directed. |
| 40 | M & L for preparation of new or previously untreated wood based surfaces of any description, over 10 cm in width or girth, not otherwise described with two coats of synthetic enamel paint over a coat of pink primer. Please Enable Macros to View BoQ information |