| 1 | Dismantling plain or corrugated steel sheeting any guage, thickness, including Nainital pattern or similar pattern roof covering complete all as specified and directed. |
| 2 | Demolition of brick work or stone masonry precast PCC block walling built in cement mortar complete all as specified and directed. |
| 3 | Taking down cement or cement lime plaster of any description on brick or PCC blocks or stone wall or concrete surface etc including racking out joints, hacking for keys, scrubbing down with water etc all as specified and directed. |
| 4 | Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed. |
| 5 | Dismantling timber scantlings 40 sq. cm and over in section, in any position complete all as specified |
| 6 | Taking up or down 15mm dia steel tubing and connections by disconnecting fittings/tubing from existing tubing were required including cleaning for refixing or removal from site complete all as specified and directed. |
| 7 | Taking up or down 20mm dia steel tubing and connections by disconnecting fittings/tubing from existing tubing were required including cleaning for refixing or removal from site complete all as specified and directed. |
| 8 | Dismantling water tanks 500 ltrs capacity complete all as specified and directed. |
| 9 | Dismantling water tanks of any description, capacity exceeding 500 litres but not exceeding1000 liters complete. |
| 10 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) not exc 1.5 sqm each.& removing to or from store all as specifed & directed. |
| 11 | Taking down chowkats or frames exc 1.5 Sqm but not exc 4 Sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed. |
| 12 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 13 | Dismantling of ceiling board (flbre pulp, insulation etc) or insulation boards/slabs/blankets any thickness, including cover fillets complete all as specified and directed. |
| 14 | S&F in repairs of galvanised mild steel wire cloth 0.45 mm nominal dia of wire and average width of aperature 1.18mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed. |
| 15 | Hacking out old broken glass (any thickness, size, quality or description) from wooden/metal frames, glazed with putty or fixed with beads including punching or drilling out old glazing pins/spring clips and providing and fixing new ones all as specified |
| 16 | S&F 4 mm thick sheet glass, ordinary quality and glazing with oil putty in square not exc 0.50 Sqm in each pane complete all as specified and directed. |
| 17 | S&F Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa (AZ 150) as in roof covering / cladding to wall , fixed with self tapping screw as specified and directed |
| 18 | S&F Pre painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall , fixed with self tapping screw as specified and directed |
| 19 | S&F 0.63mm thick galvanised corrugated MS sheeting (CGI sheet roofing) with two corrugation side laps, with 120gm Zinc (Spelter) coating per Sqm both sides inclusive fixed with coach screws and washers as in roofs etc all as specified |
| 20 | S&F 0.63mm thick plain galvanised MS sheeting using grade-O sheets with 120gm Zinc (Spelter) coating Per Sqm both sides inclusives, as in roof, ridges, hips, valley gutters, drip and straight flashing complete all as specified and directed. |
| 21 | S&F of powder coated grid frame work for false celling comprising of the following sections for making partitions of 600x600 mm size fixed to walls with rawl plugs & screws and hanged to roof with and including 4mm dia GI wire suspender of suitable length and butterfly clips, size of main tee shall be 28mmx24mmx0.3mm thick , cross tee shall be 28mmx24mmx0.3mm thick and wall angle shall be 24mmx24mmx0.3 mm thick incl 4 mm thick E-Board Classic (Make-Everest) for insulation and accoustic purpose, 595 x 595 mm size fixed with staples on snap grid as in ceiling with and including dusting of surface complete all as specified and directed.complete all as specified and directed. |
| 22 | M&L for brick work with sub class 'B' bricks using old size bricks straight or curved on plan exc 6 mtr mean radius, built in CM 1:6 all as specified and directed. |
| 23 | M&L for rendering 15 mm thick readymade plaster on inner/outer walls by adding 17-19% of potable water by weight of material for thickness above 15mm it is recommended to be applied in multiple layers. ready mix plaster shall complies with IS 1661-1972, IS 2250-1965, IS 2402-1963 and confirms the compressive strength @ 28 days 10-12 Mpa/Bulk density 1500-1600 Kg/m3. (Note : The rate quoted by contractor shall include cleaning of surface, application as per instruction and scaffolding upto 20 Mtr ht all as specified and directed.Make Fosroc/ Sika/ Ultrarech/ Choksey |
| 24 | M&L for preparation of New plastered surfaces & applying a layer of Birla putty on wall surfaces including cornics etc for proper levelling of plaster and two coat of oil emulision distemper complete all as specified and directed. |
| 25 | M/L for complete removal of existing treatment for preparing old painted surfacess and applying two coat of distemper oil emulsion over a coat of primer complete all as specified and directed. |
| 26 | M&L three coats of white wash on ceiling including all preparation complete all as sopecified |
| 27 | Material & Labour for applying Two or more coats of 100% remium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including primingcoat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces complete all as specified and directed. |
| 28 | M&L preparation of old surfaces including cornices etc and one coat of oil bound distemper complete all as specified and directed. |
| 29 | S&F 20mm thick 2nd class soft wood (Chir) boarding planned one side fixed with butt joints with nails in any situation/position except flooring and skirting complete all as specified and directed. |
| 30 | M&L for 2nd class hard wood clean sawn in as in scantling framed and over 40sqcm fixed with screws etc all as specified and directed.. |
| 31 | S&F in repair 110mm dia PVC (SWR) pipes single socketed in any length with rubber joints fixed to walls or laid in trenches etc complete. |
| 32 | S&F in repair 75mm dia PVC (SWR) pipes single socketed in any length with rubber joints fixed to walls or laid in trenches etc complete. |
| 33 | M&L 300x450x7mm thick glazed ceramic digital tiles coloured incl , design and pattern as approved fixed as in vertical surface etc, set and jointed in neat cement slurry and pointed with white cement with colour pigment to match incl rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 complete all as specified and directed. |
| 34 | M&L colour non skid ceramic tiles 7 to 8 mm thick ( square/ rectangular) area of each tiles exc. 0.11 sqm but n.exc. 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white cement with colour pigment incl 15mm thick screed bed in CM 1:6 complete all as spd |
| 35 | M&L for 15mm bore GI tubing, medium grade, galvanised with and including all GI fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed. |
| 36 | M&L for 20 mm bore GI tubing, medium grade, galvanised with and including all GI fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed. |
| 37 | S&F in repair 15mm dia bib tap long body CP, screwed for iron pipes complete all as specified and directed |
| 38 | S&F angle cock 15 mm bore brass chromium plated, screwed both ends for pipes or for unions fixed in repairs including making good to match with existing surface |
| 39 | S&F pillar taps 15 mm bore, brass chromium plated , screwed down high pressure with or without letter Hot or Cold with long screwed shanks and fly nut complete all as specified, fixed in repairs. |
| 40 | S&F bib tap standard of PTMT (Polytetra Methylene Terephthalate Engineering Thermoplastic Bath fitting), any colour, screwed foriron pipe 15 mm bore pipe (minimum weight 90 gm) all as specified, fixed in repairs (Make : Prayag or Equivelent as approved) |
| 41 | S&F in repair polymer white (polypropeylene Delrin and ABS) low level flushing cistern 10 Ltrs capacity, valveless, syphonic action type complete with inlet, ball valve float valve, bends brackets, rawl plug, brass screws handle etc complete, complete all as specified and directed. |
| 42 | S&F in repairs, 550x400mm vitreous China, wash hand basin , flat back with pedestal excluding trap and waste chain and plug and porcelain stopper including sutaible size brackets waste pipe and waste coupling complete all as specified and directed. |
| 43 | S&F vitreous china squatting pan Orrissa pattern size 580 x 440 mm white with intregal foot rests, with & including P or S trap (excluding material & labour of flushing cistern and flush pipe) including conection to trap and to flush pipe etc complete including making good to floor complete all as specified and directed fixed in repairs. |
| 44 | S& F in repair Vitreous china premium/ 1st quality wash down water closet EWC white/ ivory/off white (closed pattern incl all necessary accessories like rag bolts/ gel gasket etc. (excluding flushing cistern & flush pipe) complete in all respect all as specified. |
| 45 | M&L PVC (SWR) floor trap 75mm dia plain with grating including jointing with solvent cement etc complete, fixed in repair. |
| 46 | S&F PVC circular top cover suitable to rotational moulded polyethylene water storage tanks of 300 /500 litres capacity tanks of standard mares, with 6 mm dia nut and bolts on two ends of cover to act as hinge as will as locking arrangement for side opening |
| 47 | M&L for sunken floor treatment as described as under (i) to (vii) :- (I) Demolition of cement concrete of any description and in any position not otherwise specifically provided or in any type of filling in sunken portion & cleaned the sunken portion incl vertical wall surface complete as directed. (II) M&L to fill the sunken floor with PCC ( 1:5:10) type E-2 using bk aggregate over the treated surface complete all as specified and directed. (III) M& L 40mm thick (Min) PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate with integral water proofing compound as per manufacturer instructions on bottom of sunken portion with proper slope towards spout. Vertical sides shall be plastered in CM (1:3) 15 mm thick mixed with water proofing compound as per manufacturer instructions. Plaster shall be extended over PCC coving when the same is green i.e. PCC & plaster be carried out at the same time complete all as specified and directed.(IV) After laying sewage/ plumbing pipes with fixtures in position 2 coats of OMIPLAS EP-101 epoxy compound shall be applied complete all as specified and directed.(V) Spouts of 25mm dia GI pipe light grade projecting 450mm clear of face outer a wall with mosquito proof cap on inner face of pipe shall be provided to drain out seepage water ,including cutting holes and making good if needed as specified and directed. (VI) Test again of water tightness by pounding for 72 hours & rectify defects if any till total elimination of defects complete all as specified and directed.The sunken portion shall be tested for leakage / seepage / dampness by pounding with water for 72 hours. In case any defect is noticed the portion shall be grouted with cement slurry mixed with suitable chemical & tested again. The process of grouting and testing shall be repeated till leakage / seepage / dampness is eliminated. |
| 48 | Factory made single extruded WPC (wood polymer Composite) solid door/ window/ Ceosetory window & other Frames/ Chowkhat of size 45 x 70 mm comprising of PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wwod powder/ rick husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms ) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded stat headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N / mm 2 and resistance to spread of flame of Class A catogory with property of being termite/ borer proof, water / moisture proof and fire retardant and fixed in position with MS hold fast/lugs / SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). |
| 49 | Factory made single extruded WPC (wood polymer Composite) solid plain flush door shutter of 35 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/ cum and screw withdrwal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N mm2 modulus of elasticity 850 N / mm2 and resistance to spread of flame of Class A catogary with property of being termite/ borer proof, water/ moisture proof and fire retardanat and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, all as per direction of Engineer-In-Charge (Note:- stainless steel butt hinges and necessary SS screws shall be paid separately. |
| 50 | S&F mild steel work as hold fasts, bands, straps, supports or stays for pipes eaves gutter including bolts if required, hooks (stay), clamps and similar small articles, conforming toFe 310-0 or Fe 410-0 complete all as specified and directed. |
| 51 | S&F 100mm size MS butt hinges, medium weight, cold rolled and fixed complete all as specified and directed. |
| 52 | S&F 150mm long Aluminium tower bolt and fixed complete all as specified and directed. |
| 53 | S&F 125 mm size aluminium handle plate type anodised complete all as specified and directed. |
| 54 | M & L for roof surface must be pressure-washed with water with, is to be used to and/ or remove all dirt, dust, chalking and waste products. Remove algae, mold by using bleach solution. 2 tiles joint repair all visible and joint more than 0.50mm and not giving hollow sound, on the tiles roof or at the junctions of flat roof & vertical parapet wall, pipe joints, should be cut and widen v shape with mechanical cutter in the size (6mm W x 6mm D) and fill with PMM methodology.Glass fiber apply URP or Primeseal A on the well prepared groove, allow to cure tack free. Followed by filling all the joints covering the entire area uniformly with suitable chemical. Allow chemical to cure a minimum 24 hours. Apply minimum 50mm-100mm width 45 GMS glass Fibre mesh/ non-woven geo testile fleece with the coat of Roofseal classic along the length of crack when the 1st coat is still in wet condition. Apply the second coat with an interval if 4-6 hours. Waterproofing: Apply a coat of Roofseal classic (diluted with water in the ratio 2:1) as Self Priming 14.0-18.0 Sq. mt/litre.Allow coating to dry for 3-4 hours. Applt two coats of Dr Fixit Roofseal classic/litre/coat, without, the rate of application being the same for both the coats. This would ensure correct consumption of material that will deliver a total of DFT of microns. Allow the system to air cure for 5 days minimum. Check to see no void surface is left untreated/uncoated. The material having following technical specification as per ASTM D 6083 M- type II, Attains a Tensile strength of 2.5 N/mm2 confirming to ASTM D 2370: Elongation at break > 300% confirming ASTM D 2370, Adhesion to Concrete 2.0N/mm2 Confirming ASTM D 4541 and crack bridging ability up to 2mm, air cure the coating for 7 days before water pound test for 48 Hrs. The system comes with 7 year waterproofing warranty from service provider. For vertical surface : Apply 2 coat of Dr Fixit Roofseal classic with forced coverage of /litre/coat. Entire terrace should be coated with roofseal classic alongwith parapet walls needs to be enveloped with roofseal classic/Raincoat system. The total 3 coats treatment inclu taking down/dismantling of old tarfelt/old unserviceable roof treatment from RCC roof by scrapping, broomig and washing with water etc including 10mm thick rendering in CM 1:3 with water proofing compound complete all as . Make : Dr Fixit, Asian or equivalent (Note : The treatment should be carried out through authorised applicator only) |
| 55 | S&F rotational moulded polythene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in postion 500 ltrs capacity and including 20mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe minimum weight 210 gram of complete all as specified and directed. |
| 56 | S&F rotational moulded polythene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in postion 1000 ltrs capacity and including 20mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe minimum weight 210 gram of complete all as specified and directed. |
| 57 | S & F 20mm Dia Aluminium alloy anodised curtain rod decorative fency type with brackets complete all as specified. Please Enable Macros to View BoQ information |