| 1 | Systematically cleaning of drainage line any size by using shovel,pix,pushcart, bamboo etc incuding taking all safety measures and removing all disposal/debris outside MD land complete all as directed. Note: (i)The place of disposal shall be find out by the contractor.(ii) The drain shall be cleaned by the contractor,including those found in choked condition to the full satisfaction of E-in-C. |
| 2 | Cutting into existing manholes for connecting new/old drains, making good to pipe & rendering, cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in cement concrete 1:2 :4 type B-1 smooth finished, & reforming benching as required, internal dia of pipe 150mm. |
| 3 | S & F in repairs cast iron work grade FG 150, articles exc 5 kg each unmachined, in brackets, gully traps/covers, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles |
| 4 | M & L for PCC 1:2:4 type B-I using 20mm graded stone aggregate as in coping, bed plates, kerbs etc. and similar work including necessary formwork weathring slightly rounded or chamfered all as specified & directed |
| 5 | Demolition of RCC cover slab of any description and in any position not otherwise specifically provided for including reinforcement cut as required to facilitate demolition and separating, scraping and cleaning of reinforcement and removing debris outside MD land.Note: The place of disposal shall be find out by the contractor. |
| 6 | M&L for providing precast cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) in cover slabs for manholes, etc and similar articles with plain fair faces including chamfers, weathering, throating etc and setting in cement mortar (1:4) with joints to match. Note:- (i) Precast cement concrete cover shall be reinforced. Reinforcement shall be measured and paid separately. |
| 7 | M&L for TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with the clips. |
| 8 | Demolition of brick work or stone/boulder masonry, built in cement mortar, including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stone work & precast concrete articles including copings etc.and removing debris outside MD land complete all as specified Note: The place of disposal shall be find out by the contractor. |
| 9 | M&L for brick work with sub class 'B' bricks (old size) straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified. |
| 10 | Dismantling wrought iron or mild steel work of any description not otherwise provided for . |
| 11 | M&L MS framed work such as grills, gratings etc with ends of bars shouldered and or rivated or forged into spikes, framed guard bars and similar work as in drain cover confirming to Fe 410 or Fe 310-0 |
| 12 | M&L for preparing new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer paint complete all as specified. |
| 13 | Taking down cement plaster of any description and in any position including raking out joints, hacking for key scrubbing down with water etc and removing of debris from site complete |
| 14 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM (1:4) and finished even & smooth without using extra cement completed all as specified. |
| 15 | Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) all as specified and removing demolished material out of MD land |
| 16 | Material & labour PCC 1:3:6 type C2 (40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified |
| 17 | M & L for Cement concrete in surface channels and drains using Type C2 in CM 1:3:6 all as specified. |
| 18 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped end etc. |
| 19 | S&F in repairs for Fe-410-W (Gde-E-250)quality-A plates (plain and chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment in drain cover, manholes cover etc complete all as specified and directed. Please Enable Macros to View BoQ information |