| 1 | Demolition of concrete (unreinforced) in ground floors and paving n exc 15cm thickness (below or above ground level) complete all as specified and directed. |
| 2 | M&L for 100 mm thick cement concrete 1:4:8 type D-2 (40mm graded aggregate) as in floor/sub base and under interlocking all as specified and directed. |
| 3 | M & L for 100 mm thick cement concrete 1:2:4 type B-1 (20 mm graded aggregate) as in floor complete all as specified and directed. |
| 4 | Dismentling of stone slabs and tiles laid bedded and pointed in any mortar of any description including removal of sand cushioning under paver block, complete all as specified and directed. |
| 5 | M&L for 60 mm thick, M-35 grade, machine pressed precase concrete inter locking paver block using grey cement and pigment of any shape and size confirming to IS 15658-2006 complete all as specified and directed. |
| 6 | M&L for sand filling under floors or in foundations including spreading, levelling, watering and consolidation complete all as specified and directed. |
| 7 | Refixing for Machine pressed precast concrete interlocking pave block and shape and size confirming to IS 15658-2006 of 60mm thickness M-35 grade including leveing and spreading of sand cusion as laying in floor etc complete all as specified and as directed . |
| 8 | M&L cement concrete type C-1,1:3:6 ( 20mm graded stone aggregate) as in copings, packing around interlocking paver blocks etc complete all as specified and directed. |
| 9 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. |
| 10 | M & L for preparation of new or previously untreated plaster/ concrete/Stone surface of any description over 10cm girth or width, not otherwise described & applying applying two coats of synthetic enamel paint over a coat primer complete all as specified and as directed |
| 11 | M & L for preparation of old painted plaster/ concrete/Stone surface of any description over 10 cm width or girth & applying applying one coat of synthetic enamel paint complete all as specified and as directed |
| 12 | Dismentling of Precast Concrete article and precast concrete block walling built in Cement Mortar including all quoins arches pillars etc complete all as specified and as directed. |
| 13 | M&L for precast cement concrete Block Masonary 1:5:8 with solid blocks exc 10 cm in width and setting in mortar 1:6 complete all as specified and directed. |
| 14 | Taking down cement plaster on brick or concrete wall surface of any description including raking out joints scrubbing down with water complete all as specified and directed. |
| 15 | M&L for rendering to brick / concrete surfaces, 15 mm thick in cement mortar 1:4 complete all as specified and as directed. |
| 16 | Material & Labour for applying Two or more coats of 100% Premium acrylic Emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces complete all as specified and directed. |
| 17 | Dismantling of Mild Steel Work of any description not otherwise provided for complete all as specified and as directed. |
| 18 | S&F Mild Steel work confirming to Fe - 290, Grade E-165, as in framed work such as Grills, Gratings, Ladders etc with ends of bars shouldered and/or riveted, or forged into spikes, framed Guard Bars, Barred Iron Doors, gates, Ladders, framed Balusters, Walk Ways, Railings, framework of Water Tanks and similar work complete all as specified and as directed. |
| 19 | S&F framed work as in door or gates or other section with gusset plate rail bracing etc complete drilled for fixing of steel sheeting or other covering to doors etc to be prepared for hanging or sliding with and including either hook and hinges or steel hanging door fittings running rail and guides and hanging also fastening and fixing & conforming to grade E-165 (Fe-290) complete all as specified and directed. |
| 20 | Welding in repairs exc 2.5cm but n exc 5cm in length of thickness of metal to be welded of exe 6 mm but n, exe 9 mm for existing Steel gates/door/ladder etc. complete all as specified and directed. |
| 21 | Dismantling post or struts (wood,steel or RCC) any section, including taking out embedded portion in concrete and making good the disturbed groun dcomplete all as specified and directed. |
| 22 | Demolition of concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 23 | M&L PCC 1:3:6 type D2 using 40mm graded stone agg as in foundations, filling and mass-concrete complete all as specified and directed. |
| 24 | S&F for mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, flat iron fillets (for securing wire mesh etc), wind ties etc including all necessary welding, drilling etc and similar works confirming to Fe-290 grade E-165 complete all as specified and directed. |
| 25 | S&F for GI chain link fencing with PVC coated 50mmx 50mm mesh including fixing of MS flat iron, MS bars & bolts to fencing posts complete all as specified and directed. Note: (i) BOO will be detailed for workout unit weight of chain link fencing.(ii) Supply only of MS flat iron, Rod & MS bolts shall be measured & paid under relevent item of Schedule. |
| 26 | Supply only mild steel flat iron, round bars etc. in available length complete conforming to Fe-290 (Gde E-165) complete all as specified and directed. |
| 27 | Supply only mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 5cm and not exceeding 10cm long and dia of neck 11 to 15mm, complete all as specified and directed. |
| 28 | S&F in repair Galvanised 2 strand steel barbed wire 2.24mm dia barbed with 2 mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bollts incl securing or tying at crossing with and provision of heavy duty galvanised mild steel wire, staples or staple pins etc (Each line wire to be measured) complete all as specified and directed. |
| 29 | S&F in repairs GI Concertina coil (dia of col when unstretched) and fixed on angle iron post/struts complete all as specified and directed. |
| 30 | M&L for Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 31 | S&F in repairs Aluminium Composite Panel of 4mm thick exterior grade in wall/column/ceilling with combination of aluminium skin material of 0.25mm thick (two or more metallic coloured coating sheet as directed) aluminium sheet of alloy grade 1100-H14 cover material, coated on external side with PVDF coating containing 70% resins for anti-fungal and anti bacterial properties and the center core shall be with natural polythelene (HDPE) bonded to the aluminium skin on both side over aluminium frame of section 50 mm x 37 mm x 1.6 mm (16 guage) fixed on the wall/ Ceilling. Cladding panal to be fixed with rawl plug and SS screw all as approved on walls and roof including necessary accessories, complete all as per manufacturer's instructions and complete all as specified and directed. |
| 32 | S&F in repair letters of height 450mm and 60mm thickness with LED dotted lights, fixed with SS screw on ACP cladding and providing polished plain acrylic sheet having thickness of 2mm over the letters complete all as specified and directed. Please Enable Macros to View BoQ information |