| 1 | Taking out LT XLPE/PVC insulated armoured cable alongwith all joints of any size from trenches wall/roof including taking out of brick layer and sand from trenches complete all as specified and as directed by EIC. |
| 2 | Excavation in trenches by mechnical/Mannual means not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out all kind of soil complete all as specified and as directed by EIC.. |
| 3 | M&L for Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm in soft/loose soil. complete all as specified and as directed EIC. |
| 4 | Removing excavated material/soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and as directed EIC. |
| 5 | Supply and fixing Double wall Corrugated High Density Polymer Ethylene (HDPE) pipe of 50 mm sizes as per IS 14930 (Part-2):2001, Laid in trenches/floors and fixed on walls/poles, with and including neccessary fittings such as bends, sockets and other connected accessories etc., for laying of electric cables, complete all as specified and as directed by EIC. |
| 6 | All as above item No 5 but size of HDPE pipe size 90 mm diameter |
| 7 | Supply, laying and testing LT XLPE insuated PVC bedded galvanised steel strip or wire armoured earthed electric power cable with aluminium conductor 1100 volts grade, heavy duty in trenches/along pole or wall of size 16 Sq mm 4 core complete all as specified and as directed by EIC. Note:- 1. Excavation and earth work, pipes, clamps, and cable joint shall be measured and paid separetely under respective items. |
| 8 | All as per item No 7 above but of size 25 Sq mm 4 core |
| 9 | All as per item No 7 above but of size 35 Sq mm 3.5 core |
| 10 | All as per item No 7 above but of size 50 Sq mm 3.5 core |
| 11 | All as per item No 7 above but of size 70 Sq mm 3.5 core |
| 12 | All as per item No 7 above but of size 95 Sq mm 3.5 core |
| 13 | All as per item No 7 above but of size 120 Sq mm 3.5 core |
| 14 | All as per item No 7 above but of size 240 Sq mm 3.5 core |
| 15 | Supply & laying in repair 40mm bore galvanized steel tubing \\"light grade\\" with all fittings in trenches/ under roads/ along pole/ wall for cable protection all as specified & as directed by EIC. . |
| 16 | Supply & laying in repair 50mm bore galvanized steel tubing \\"light grade\\" with all fittings in trenches/ under roads/ along pole/ wall for cable protection all as specified & as directed by EIC. . |
| 17 | Supply & laying in repair 80mm bore galvanized steel tubing \\"light grade\\" with all fittings in trenches/ under roads/ along pole/ wall for cable protection all as specified & as directed by EIC. . |
| 18 | Road cutting for UG cable under road/railway crossing, pavement, hardstanding by mannually means, protection GI pipe for cable of required dai and making it good to match with the adjoining surface/structure for after cable passing complete all as specified and directed by EIC. Note : GI pipe and PCC will be measured and paid against respective items. |
| 19 | Supply & Fixing in repair 6 -16 Sqmm 4 Core cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 and 4 core XLPE armoured aluminium conductor cable complete all as specified and directed by Engr-in-Chrage..Make 3M-Seal/Birla/Denson Note : Excavation, returning filling and removel shall be measured and paid separatly under relevant item of this BOQ |
| 20 | All as per item No 19 above but of size 70 to 120 sq mm 3.5 core |
| 21 | All as per item No 19 above but of size 150 to 185 sq mm 3.5 core |
| 22 | All as per item No 19 above but of size 240 to 300 sq mm 3.5 core |
| 23 | PCC (1:2:4) type C-1 using 20 mm graded stone aggregate as in coping/plinth block including necessary form work at arround LT panel and around the street light pole depot area, complete all as speciifed and directed by EIC, |
| 24 | PCC (1:3:6) type C-1 using 20 mm graded stone aggregate as in coping/plinth block including necessary form work at Lt panel and street light pole depot area complete all as speciifed and directed by EIC. |
| 25 | Material and Labour for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation of pole upto ground level at arround LT panel and around the street light pole depot area, complete all as speciifed and directed by EIC. |
| 26 | Trimming and cutting of tree branches(not more than 50 mm girth) coming across 11 KV HT over head line clearing the line around 2m single/both sides and and disposal of branches from site exeeding 50m and not exceeding 250m from site complete all as directed by Engr-in-Charge.Note : -(i) Length of span is approx 50 to 70 RM.(ii) Due care is to be given while trimming/cutting the tree branches that there should no damage to over head line conductor/pole. In case due to any negligence, damage is caused to be make good/renewal by the contractor from his own resources and nothing extra is admissible.(iii) All Safety to labourer must be adhered by the contractor during trimming and cutting of tree branches. |
| 27 | Taking down existing unserviceable ammeter, supply and fix new digital ammeter with built in selector suitable for mounting on HT/LT panel of suitable CT ratio complete all as specified and directed by EIC. |
| 28 | Taking down existing unserviceable voltmeter, supply and fix new digital voltmeter with built in selecter , 3 phase, 0 to 600 volts suitable for mounting on HT/LT panel complete all as specified and directed by EIC. |
| 29 | S&F of MCCB in replacement 3 Pole from 25 Amps to 100 Amps fixed type 16 KA, 415 volts complete all as specified and directed including taking out old one all as specified and directed by EIC.Make : Schneider/L&T/Legrand |
| 30 | S&F of MCCB in replacement 4 Pole 160 amps 25 KA 415 volts adjustable type complete all as specified and directed including taking out old one all as specified and directed by EIC. Make : Schneider/L&T/Legrand |
| 31 | S&F of MCCB in replacement 4 Pole 200 amps 36 KA 415 volts adjustable type complete all as specified and directed including taking out old one all as specified and directed by EIC. Make : Schneider/L&T/Legrand |
| 32 | S&F of MCCB in replacement 4 Pole 250 amps 36 KA 415 volts adjustable type complete all as specified and directed including taking out old one all as specified and directed by EIC. Make : Schneider/L&T/Legrand |
| 33 | S&F of MCCB in replacement 4 Pole 350 amps 36 KA 415 volts with adjustable O/L, S/C and earth leakage protection (ELR with CBCT) including UVR, shunt trip and auxiliary contacts complete all as specified and directed including taking out old one all as specified and directed by EIC. Make : Schneider/L&T/Legrand |
| 34 | S&F of MCCB in replacement 4 Pole 400 amps 36 KA 415 volts with adjustable O/L, S/C and earth leakage protection (ELR with CBCT) including UVR, shunt trip and auxiliary contacts complete all as specified and directed including taking out old one all as specified and directed by EIC. Make : Schneider/L&T/Legrand |
| 35 | Supply and Fixing in replacement of unserviceable Air Circuit Breaker (ACB) with new ACB, 4 Pole, 415 Volts, 50 Hz, Manual Drawout type, rated current 630 Amps, Frame size 800 Amps, Icu 50 kA at 415V, Ics 100% of Icu, short time withstand current (Icw) for 1 sec as per manufacturer standard, with Thermal Magnetic release, conforming to IS/IEC 60947-2, complete with all necessary connections, copper lugs, control wiring, interlocking arrangement, accessories, dismantling of old ACB, panel modification and bus bar modification as required, testing and commissioning complete in all respects as specified and directed by Engineer-in-Charge |
| 36 | M&L for Preparation of old painted surfaces of steel tubular poles 9/11 Mtr long including cross arms protection pipe and painting one coat of aluminium paint e ground level to top of pole and cross arms and protection pipe paint including writing poles numbers in white letter on black ground and redium tape sorunding pole colour Sub depot wise and ordinance colour complete all as specified and directed by EIC. |
| 37 | S and F in repair loop in / loop out box of internal size 250 x 210 x 115mm made out of FRP (Hot moulded type) with weather proof canopy and locking screws alongwith 5/6 Amps MCB-01 No, 15 Amps rated 3 pole connector - 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector complete in the box, duly fixed to steel tubular pole using 25 x 3mm FI clamp with suitable gland and lugs for connecting cable including taking down old one complete all as specified and directed by EIC.Hansel/Sintex |
| 38 | Taking down existing rusted/broken out MS cross arm, angle, clamps, nuts, bolts and washers and supply and fixing new MS Cross arms, bracings, supports, clamp and back plates fabricated for cable cover frame work, from structural steel section including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any type, shape or as indicated and directed inclusive of one coat of red oxide primer and two coats of aluminium paint complete all as specified and directed by EIC.. |
| 39 | M&L in replacement of unserviceable ACSR jumper and ACSR Conductor with new jumpers of ACSR conductor and ACSR Conductor of suitable size as per site including binding properly on the existing OH line with clamp, nuts & bolts etc.complete all as specified and directed by EIC. |
| 40 | supply and fixing in replacement of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed by EIC. |
| 41 | supply and fixing in replacement of Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade complete all as specified and directed by EIC. |
| 42 | M&L for replacement of shackle type porcelain, vitreous white brown or insulator working under 1100 volts grade , pressure of height 75 mm & 90mm dia insulators, dia of bolt 12mm , section of straps 31 x 3mm, washers, nuts complete all as specified & directed. |
| 43 | Supply and fixing in replacement of guard wire under LT Over head line Cradles, hexagonal/rectangular,fabricated with galvanised steel wire 3.15 or 4mm dia complete all as specified and directed by EIC. Please Enable Macros to View BoQ information |
| 44 | Supply and fixing in replacement of guard wire under LT Over head line Cradles, hexagonal/rectangular,fabricated with galvanised steel wire 3.15 or 4mm dia complete all as specified and directed by EIC. Please Enable Macros to View BoQ information |