| 1 | Cartage of following material from ESC Noida/Sahibabad/ Ghaziabad /Any other ESC of Meerut Discom to JE Store and from JE store to various points site of work including loading and unloading at both ends : - |
| 2 | PCC Pole 8.5 Mtr Long |
| 3 | PCC Pole 11 Mtr Long |
| 4 | Earthing Complete |
| 5 | Top Channel |
| 6 | Dropper Channel |
| 7 | 11KV XLPE 3Cx185sqmm Cable |
| 8 | O/D Jointing Kit 11 KV3cx185sqmm |
| 9 | Stragth Through Jointing Kit 11kv 3x185 sqmm |
| 10 | MS Angle for Cross Bracing |
| 11 | ACSR Rabbit Conductor |
| 12 | T-off Channel |
| 13 | 11 KV Polymeric Disc Insulator with Disc |
| 14 | 11 KV Polymeric Pin Insulator with Pin |
| 15 | 11 KV V-Type Cross Arm |
| 16 | F Bracket |
| 17 | Stay Set Complete |
| 18 | 11/0.4 KV T/F 250 KVA |
| 19 | MS Channel for HT Fusing Arrangement |
| 20 | 11 KV Fuse Set. |
| 21 | Copper L-piece 50x225x10mm (LS) |
| 22 | Distribtuion Box |
| 23 | LT ABC 3Cx120+1x95+1x16 sqmm |
| 24 | LT PVC Cable Al 1x240sq mm |
| 25 | LT XLPE 1x35sqmm |
| 26 | ACSR Weasel Conductor |
| 27 | Earthing Complete |
| 28 | Providing & fixing of following material of standard make / best quality for complete the work of HT / LT line as per RESPO norms by the contractor at his own cost : - |
| 29 | Stone Pad |
| 30 | Concreting of Pole |
| 31 | GI Pipe |
| 32 | HDPE Pipe with / for road crossing |
| 33 | Clamp with Nut & Bolt |
| 34 | Holding Clamp |
| 35 | Concereting of Stay |
| 36 | T/F Plinth Fencing Iron |
| 37 | 11 KV Polymeric Disc Insulator |
| 38 | 11 KV Polymeric Pin Insulator |
| 39 | Pearcing Clamp |
| 40 | I Hook |
| 41 | J Hook |
| 42 | Suspention Clamp |
| 43 | Dead End Clamp |
| 44 | Al Leg long barrel off size (LS) |
| 45 | Chemical earthing |
| 46 | Cable RCC / Stone Route Marker yellow colour with proper marking. |
| 47 | F-Bracket |
| 48 | Copper L-piece 50x225x10mm (LS) |
| 49 | Making of Chair of 2x2x1.5 or as per site requirement & RESPO norms.(i) MS channel size 100x50x2240 mm. - 10 Nos.(ii) MS Angle size 65x65x6 mm. - 2 Set.(iii) Holding clamp with nut & bolt. - 12 Nos.(iv) Earthing complete. - 6 Nos.(v) Danger board - 4 Nos.(vi) Sundry items. - LS |
| 50 | Construction of new distribution T/F Plinth. The size of plinth shall be 2 Mtrs. long, 2 Mtrs. wide and height 1.5 Mtrs. from ground level OR AS PER WORK SITE REQUIREMENT with 15 CM thick top CC slab with 02 Nos. Channel. The above work includes Excavation of earth, laying of bring ballast pad for foundation brick work, CC and plastering and proper curing complete with all respects as per RESPO schedule. (providing material for Plinth : Cement - 14 Bag; Fine Sand - 3 Cu.mtr; Coarse sand - 1.2 Cu.mtr; Brick Ballast - 0.45 Cu.mtr; 1st Class Bricks - 1300 Nos.; Stone Ballast - 0.4 Cu.mtr; MS channel 125x65mm - 48 Kg.; MS Twisted bar of size 20mm - 40 Kg.) |
| 51 | The Excavation of foundation pit in CC road/ mix soil/ normal soil/ soft & hard rack by using heavy duty compressor and its back filling and leveling etc. The size of the pit will be 600x600x1800 mm for each pole and having a depth of 1/6 of the full length of the support. |
| 52 | Fabrication of MS channel / Angle / cross arm as per site requirement complete in all respects. |
| 53 | Erection of PCC pole 8.5 Mtr. including fitting of all reqired accessories of HT/LT line as per RESPO schedule. |
| 54 | Erection of PCC pole 11 Mtr. including fitting of all reqired accessories of HT/LT line as per RESPO schedule. |
| 55 | Grouting of each pole (In ratio of 1:4:8 in Cement, sand and Brick Ballast) in size 450mmx450mmx1800 mm as per RESPO schedule Complete in all respects. |
| 56 | Fixing of 11 KV Fuse Set. |
| 57 | Fixing of Distribution Box. |
| 58 | Fixing of F-Bracket |
| 59 | Fixing of Copper L-piece 50x225x10mm (LS) |
| 60 | Fixing of 11 KV Polymeric Disc Insulator with Disc |
| 61 | Fixing of 11 KV Polymeric Pin Insulator with Pin |
| 62 | Making / fixing of O/D Jointing Kit 11 KV3cx185sqmm |
| 63 | Making / fixing of Stragth Through Jointing Kit 11kv 3x185 sqmm |
| 64 | Grouting & concreting of stay rod 1800x16 mm & Fixing, Tighting & nozzling of stay wire 5 kg with the pole of required tension with clamps, bolt & nut. |
| 65 | Excavation of earth and driving of M.S. earthing rod of size 20x2500 mm in earth and jointing through G.I wire of 6 SWG between support and earth electrode by providing proper size of bolts and nuts etc. as per RESPO schedule Complete in all respects. |
| 66 | Laying of LT PVC / XLPE Cable Al. 1x35 / 240 Sq.mm. including fixing of all accessories as per RESPO schedule Complete in all respects. |
| 67 | Laying, Lifting and final Binding, Sagging of ACSR Weasel Conductor including fixing of all accessories as per RESPO schedule Complete in all respects. |
| 68 | Laying, Lifting and final Binding, Sagging of ACSR Rabbit Conductor including fixing of all accessories as per RESPO schedule Complete in all respects. |
| 69 | Laying, Lifting and final Binding, Sagging of Cable LT ABC size 3Cx120+1x95+1x16 Sq.mm. including fixing of all accessories as per RESPO schedule Complete in all respects. |
| 70 | Mounting, installation of T/F (250 KVA) on Plinth / Chair, alongwith double earthing of the same, complete in all respect as per RESPO schedule. |
| 71 | Drilling of suitable dia 160 mm by trenchless method by horizontal boring machine at a depth of 1.5 mtrs below the ground level for road crossing / laying of 11 KV cable with Road Restoration in accordance witgh GPR Survey. Any damage to Road part from estimate shall be responsibility of contractor shall take NOC permission from concerned Authority & Restore as per their norms. |
| 72 | Providing of 06 Mtr long pieces of HDPE pipe 160mm Dia (PVVNL approved) after inspection of competent committee at manufacturing site of the items with actual guarantee period. |
| 73 | Laying and interconnecting of above 06 Mtr long pieces of HDPE pipe (160mm Dia) (PVVNL approved) in trench for laying of 11 KV cable complete in all respects.. |
| 74 | Digging of pits of size 4 mtr x 4 mtr x 1.5 mtr for cable loop. |
| 75 | Providing & Fixing of HDPE Socket suitable for HDPE pipe 160mm dia. |
| 76 | Tree prunning / cutting as per work site requirement. |
| 77 | Laying and pulling of 11 KV XLPE Cable (3Cx185 Sq.mm.) through HDPE pipe complete in all respects. |
| 78 | Laying of 11 KV XLPE Cable (3Cx185 Sq.mm.) in loop & riser as per work site requirement complete in all respects. |
| 79 | Hi port test for 11 KV XLPE cable (3Cx185 Sq.mm.). |
| 80 | Hoisting of 11 KV XLPE cable on double pole structure through GI pipe 6 inch dia 3 mtr long fixed on pole structure including its jumpering complete with clamps, bolts and nuts. |
| 81 | WORK OF PROVIDING AND FIXING OF 03 NOS. NEW WIREMESH FENCING OF 11/0.4 KV L.T. SUB-STATION INSTALLED AT ABOVE PLACE AS PER FOLLOWING (All Material provided by contractor for above work.) :- |
| 82 | 1. Frames of size 12'X15'x6' for each fencing of LT Sub-stations. (All Material provided by contractor for above work.)2. The fencing shall be fabricated out of MS angle iron of size 40x40x5 mm having 2 Nos. legs of 45 Cm. long in each frame duly welded and fixed with wire mesh of size 75mm 25mm, 10 SWG within the frame, pressed under MS flat of size 25x5 mm inside the angle iron on all four sides with the help of duly Welded along with cross bracing of 25x5 mm MS flat on every frame will be grouted in 1:2:4 cement mortar with cement, coarse sand 20 mm gauge stone ballast. 3. Every frame after Fabrication will be painted with one coat of red oxide and two coats of Green synthetic enamel paint of approved make after proper cleaning. 4. The above mentioned frame will be jointed with each other with 70 mm long MS flat of size 25x5mm by first class welding as per site.5. Fabrication and providing of wire mesh fencing frame for gate of size 4’x6’. Fabricated as per above specifications with proper locking arrangement. |
| 83 | Construction of boundry / toe wall in bottom of fencing in brick work cement mortar 1:6 (1 cement : 6 coarse sand) for link in the size of 0.22mx0.60m (0.30m in earth, 0.30m above ground level) including plaster in cement mortar 1:4 and finishing with water proof cement paint. (Approx construction 12 Mtrs. boundry / toe wall for each fencing of LT Sub-stations.) (All Material provided by contractor for above work) |
| 84 | CHEMICAL EARTHING WORK (SUPPLY AND INSTALLATION) AS PER FOLLOWING:-Note :- The all material and labour shall be provided by the contractor with 36 month guarantee for resistance value less than one OHM. |
| 85 | Providing of earthing electrode :-Material Description : GI Electrode, Galvanization : 150 Micron (Min),IS Standard : IS 3043 / IEEE - 837, Short Time Current Rating kA (rms) For 1 Sec : 42 KA For 1 Sec, Dia of Electrode : 50mm, Length of Electrode : 3000mm, Weight of Electrode : 15 Kgm, Pipe Thickness : 4mm or As per IS : 1239 4mm, Inside Filling Material : Crystalline Conductive Mixture, Inner Strip : 3100 X 50 X 6 mm,Terminal Hole Dia : 16 MM. Technology : Metal Thermal Spray (Joints) Protection Earthing Resistance Value in Different Soil Conditions with ERIC Backfill Compound : Normal Soil - Upto 2 Ohms, Sand. Muran Soil - Upto 4 Ohms, Rock Soil - Upto 4 Ohms,Electrode Testing Cetificate : CPRI Testd. Surrounding Filling Material (ERIC):- Product : ERIC (Earth Resitance Improvement Compound), IS Standard : IS 3043/IEEE 837, Chemical Composition : Graphite, Activated Carbon, Bentonite, ETC., Resistivity Value : >0.2 Ohm Per Meter, Melting Temperature : 2500 Degree Centigrade,Specific Gravity : 2.6, PH Value of Chemical : 7-9, Solubility in water : 3.54, Colour : Light cream/Ash, Main Caution ; Sodium, Moisture Capacity at 105 Degree : 10%, Weight of Chemical used / Earthing Pit : 50 Kg, Water Absorbing Capacity : 20 Times, Environmental Effects : Eco Friendly. Test Certifictae : ROHS Certified, Thermal Stability : Testsed, Corrosion Resistance : Tested, Swell Test Certificate : Yes, Ph Value Test Certificate : Yes. Installation Parameter :- Need Hole Dia : 6\\"-8\\" Need Hole Depth : 3 Meter,Guarantee : 36 Month. |
| 86 | Providing and fixing of GI strip of size 50 mm x 6 mm suitable for T/F. |
| 87 | Providing and fixing of PVC Pit covers for above earthing electrode terminals. Please Enable Macros to View BoQ information |