| 1 | Providing maintenance services for summer appliances on daily basis by engaging Refrigerator Mechanic-1 No (Skilled) and Helper-01 No (Semi Skilled) for necessary servicing of Air conditioners, water coolers & refrigerators and carrying out necessary repairs, filling of refrigerent gas, shifting of AC, etc. complete all as specified and as directed.Note: (i) The above personnel shall have to be present at the MES service centre at HQ BSA/IMH Complex/TV to carryout the work also.(ii) Any spare parts/refrigerant gas required to be used by the above present shall be measured and paid seperately as \\"supply only\\" (iii) Daily Job card shall be issued to the above presonnel by the concerned JE E/M as per requirment at site(iv) All necessary tools shall be provided by contractor |
| 2 | Supply only AC single phase 230 Volts contactor assembly for 1.5/ 2.0 TR capacity split AC condensing unit complete all as specified and as directed. Make: Carrier/Voltas/LG/Amtex or equivalent as approved by GE |
| 3 | Supply only Strainer for Split AC of any capacity complete all as specified and as directed. |
| 4 | Supply only 4 mfd capacitor for blower motor of AC of any capacity complete all as specified and as directed.Make: Sarda/ Universal/Tibcon motor or equivalent as approved by GE |
| 5 | Supply only 6 mfd capacitor for blower moter of AC of any capacity complete all as specified and as directed.Make: Sarda/ Universal/Tibcon motor or equivalent as approved by GE |
| 6 | Supply only 36 mfd running capacitor of any capacity complete all as specified and as directed.Make: Sarda/ Universal/Tibcon motor or equivalent as approved by GE |
| 7 | Supply only 40 mfd running capacitor of any capacity complete all as specified and as directed.Make: Sarda/ Universal/Tibcon motor or equivalent as approved by GE |
| 8 | Supply only 50 mfd running capacitor of any capacity complete all as specified and as directed.Make: Sarda/ Universal/Tibcon motor or equivalent as approved by GE |
| 9 | Supply only 100-120 mfd Starting capacitor of any capacity complete all as specified and as directed.Make: Sarda/ Universal/Tibcon motor or equivalent as approved by GE |
| 10 | Supply only Sensor for 1.5/ 2.0 TR capacity Split type AC complete all as specified and as directed. |
| 11 | Supply only Fan Blade for 1.5/ 2 TR capacity Split Type AC for condenser unit complete all as specified and as directed. |
| 12 | Supply only Over load protector for Split Type AC of capacity 2 TR complete all as specified and as directed. |
| 13 | Supply onlyOver load protector for Split Type AC of capacity 1.5 TR complete all as specified and as directed. |
| 14 | Supply only Capillary copper tube of size 0.064 inch dia complete all as specified and as directed. |
| 15 | Supply only Runner for Indoor unit of 1.5/ 2.0 TR Split Type AC complete all as specified and as directed. |
| 16 | Supply only Starting Relay for Split type AC of capacity 1.5/ 2.0 TR complete all as specified and as directed. Make- Ranutrol/Amazor/Elkay/Real life/Uxcell or equivalent as approved by GE |
| 17 | Supply only copper pipe (hard) 5/8\\" dia with PUF insulation as per required length at site complete with flaring nuts of suitable size (brass) complete all as specified and as directed. |
| 18 | Supply only copper pipe (hard) 3/8\\" dia with PUF insulation as per required length at site complete with flaring nuts of suitable size (brass) complete all as specified and as directed. |
| 19 | Supply only copper pipe (hard) 1/4\\" dia with PUF insulation as per required length at site complete with flaring nuts of suitable size (brass) complete all as specified and as directed. |
| 20 | Supply only copper pipe (hard) 1/2\\" dia with PUF insulation as per required length at site complete with flaring nuts of suitable size (brass) complete all as specified and as directed. |
| 21 | Supply only PVC flexible hose pipe 20 mm for water drain out line dually clamped on wall complete all as specified and as directed. |
| 22 | S&F in repairs 15mm bore chromium plated push cock suitable for water cooler of any capacity as per existing specification complete all as specified and as directed. |
| 23 | S&F in repairs Thermostat switch for water cooler complete all as specified and as directed. Make : Indfoss /Danfoss/Ranutrol or equivalent as approved by GE |
| 24 | S&F in repairs Ball PTMT valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule of size 15 mm complete all as specified and directed. Make - Prayag/Polytuf/Stec or equivalent as approved by GE |
| 25 | Disconnecting defective sealed compressor unit of Water Cooler 80/ 150 ltrs capacity from the water cooler and S&F in new compressor of same specification in original position all as specified and as directed. Make- Kirloskar/SP/RAM/Tecumsh or equivalent as approved by GE |
| 26 | M&L for Door gasket for 150 ltrs capacity Water Cooler complete all as specified and as directed. |
| 27 | M&L for Door gasket for 80 ltrs capacity Water Cooler complete all as specified and as directed. |
| 28 | S&F in repairs Starting Relay suitable for water cooler 80/ 150 ltrs capacity complete all as specified and as directed.Make- Ranutrol/Elkay/Real Life/Uxcell or equivalent as approved by GE |
| 29 | S&F in repairs overload protector suitable for Water Cooler of capacity up to 150 ltrs complete all as specified and as directed. |
| 30 | S&F in repairs Starting relay box type for Refrigerators/deep freezer of capacity upto 400 ltrs complete all as specified and as directed.Make- Ranutrol/Elkay/Whirlpool/Uxcell or equivalent as approved by GE |
| 31 | S&F in repairs copper Capillary tube of size 0.36 mm for Refrigerators/deep freezer of capacity upto 400 ltrs complete all as specified and as directed. |
| 32 | S&F in repairs Cooling coil for refrigerators/deep freezer of capacity upto 315 ltrs complete all as specified and as directed. |
| 33 | S&F in repairs Freezer door for Refrigerators/deep freezer of capacity upto 400 ltrs complete all as specified and as directed. |
| 34 | S&F in repairs Thermostat switch for Refrigerators/deep freezer of capacity upto 400 ltrs complete all as specified and as directed.Make- Ranutrol/Indfoss/Kelvinator or equivalent as approved by GE |
| 35 | S&F in repairs Chill tray for Refrigerators/deep freezer of capacity upto 315 ltrs complete all as specified and as directed. |
| 36 | Disconnecting defective condenser coil of Refrigerators/deep freezer upto 400 ltrs capacity and S&F new condenser coil and fixing in original position as per existing specification and size complete all as specified and directed. |
| 37 | M&L for Inner lights filament type/LED for Refrigerators/deep freezer of capacity upto 400 ltrs complete all as specified and as directed. |
| 38 | Disconnecting defective sealed compressor unit of Refrigerators/deep freezerupto 400 ltrs capacity and S&F new hermitcially sealed compressor unit of same specificationas fixed in original position complete all as specified and as directed. |
| 39 | S&F in repairs Door switch for Refrigerators/deep freezer of capacity upto 400 ltrs complete all as specified and as directed. |
| 40 | S&F in repairs 5/15 Amps 3 pin 230 Volts Plug Top complete all as specified and as directed.Make : Anchor/gold medal/havells/standard or equivalent as approved by GE |
| 41 | M&L for Servicing by Dismantling the cover of Condensor and cooling coil, thoroughly cleaning the external surface (both side) of all the component including fins, base , discaling chemicals, water etc with the help of air blower, wire brushing water jet pump etc and reassemble all the components plate, runner, fan blade etc in original position as and when directed complete all as specified and as directed for following capacity of air conditioners: - |
| 42 | Split type Air Conditioner of capacity 1.5 TR |
| 43 | Split type Air Conditioner of capacity 2.0 TR |
| 44 | S&F in repairs AC single phase 230 Volts contactor assembly for 1.5/ 2.0 TR capacity split AC condensing unit complete all as specified and as directed. (Make: Carrier/Voltas/LG/Amtex or equivalent as approved by GE) |
| 45 | S&F in repairs AC single phase 230 volt Printed Circuit Board for 1.5/ 2.0 TR capacity split type AC cooling unit (Make: carrier/Voltas/LG/Amtex or equivalent as approved by GE) complete all as specified and as directed. |
| 46 | S&F in repairs AC single phase 230 volts remote control unit (Hand set) for 1.5/ 2.0 TR capacity for split type AC complete all as specified and as directed. (Make: Carrier/Voltas/LG/Amtex or equivalent as approved by GE) |
| 47 | M&L for Re-winding Blower motor, including replacement of bushes, with same size and gauge of super enamelled copper wire for Split type AC 1.5/2.0 TR capacity (Condensing unit) complete all as specified and as directed. |
| 48 | M&L for Re-winding Blower motor including replacement of bushes with same size and gauge of super enamelled copper wire for Split type AC 1.5/ 2.0 TR capacity (Cooling unit) complete all as specified and as directed. |
| 49 | S&F in repairs outdoor/indoor Blower motor for split AC of 1.5TR/2.0 TR of Inverter/Non inverter Type complete all as specified and as directed.Make: American universal/ Air cool or equivalent as approved by GE |
| 50 | S&F in repairs Strainer for Split AC of any capacity complete all as specified and as directed. |
| 51 | S&F in repairs 4 mfd capacitor for blower moter of AC of any capacity complete all as specified and as directed.Make: Sarda/ Universal/Tibcon motor or equivalent as approved by GE |
| 52 | S&F in repairs 6 mfd capacitor for blower moter of AC of any capacity complete all as specified and as directed.Make: Sarda/ Universal/Tibcon motor or equivalent as approved by GE |
| 53 | S&F in repairs 36 mfd running capacitor of any capacity complete all as specified and as directed.Make: Sarda/ Universal/Tibcon motor or equivalent as approved by GE |
| 54 | S&F in repairs 40 mfd running capacitor of any capacity complete all as specified and as directed.Make: Sarda/ Universal/Tibcon motor or equivalent as approved by GE |
| 55 | S&F in repairs 50 mfd running capacitor of any capacity complete all as specified and as directed.Make: Sarda/ Universal/Tibcon motor or equivalent as approved by GE |
| 56 | S&F in repairs 100-120 mfd Starting capacitor of any capacity complete all as specified and as directed.Make: Sarda/ Universal/Tibcon motor or equivalent as approved by GE |
| 57 | S&F in repairs Sensor for 1.5/ 2.0 TR capacity Split type AC complete all as specified and as directed. |
| 58 | S&F in repairs Fan Blade for 1.5/ 2 TR capacity Split Type AC for condenser unit complete all as specified and as directed. |
| 59 | S&F in repairs outdoor grill for 1.5/ 2 TR capacity Split Type AC for condenser unit complete all as specified and as directed. |
| 60 | S&F in repairs Over load protector for Split Type AC of capacity 2 TR complete all as specified and as directed. |
| 61 | S&F in repairs Over load protector for Split Type AC of capacity 1.5 TR complete all as specified and as directed. |
| 62 | S&F in repairs Capillary copper tube of size 0.064 inch dia complete all as specified and as directed. |
| 63 | S&F in repairs Runner for Indoor unit of 1.5/ 2.0 TR Split Type AC complete all as specified and as directed. |
| 64 | S&F in repairs Starting Relay for / Split type AC of capacity 1.5/ 2.0 TR complete all as specified and as directed. Make- Ranutrol/Amazor/Elkay/Real life/Uxcell or equivalent as approved by GE |
| 65 | Disconnecting defective sealed receprocating type compressor unit of Non inverter 2.0 TR SplitAC from the system and S&F repaired/ reconditioned sealed unit compressor in original position complete all as specified and as directed. |
| 66 | S&F in repairs rotary type compressor for Non inverter Split type AC of capacity 1.5 TR complete all as specified and as directed. |
| 67 | S&F in repairs rotary type compressor for Split type AC of capacity 2.0 TR complete all as specified and as directed. |
| 68 | Disconnecting defective sealed receprocating type compressor unit of 1.5 TR/2.0 Split AC from the system and S&F reconditioned sealed unit compressor in original position complete all as specified and as directed. |
| 69 | Supplying and laying copper pipe (hard) 5/8\\" dia with PUF insulation as per required length at site complete with flaring nuts of suitable size (brass) complete all as specified and as directed. |
| 70 | Supplying and laying copper pipe (hard) 3/8\\" dia with PUF insulation as per required length at site complete with flaring nuts of suitable size (brass) complete all as specified and as directed. |
| 71 | Supplying and laying of copper pipe (hard) 1/4\\" dia with PUF insulation as per required length at site complete with flaring nuts of suitable size (brass) complete all as specified and as directed. |
| 72 | Supplying and laying of copper pipe (hard) 1/2\\" dia with PUF insulation as per required length at site complete with flaring nuts of suitable size (brass) complete all as specified and as directed. |
| 73 | M&L for taking down existing Split AC and refixing/installing the same to a new location after servicing the indoor & outdoor unit complete all as specified and as directed. |
| 74 | Taking out and dismantling the existing rusted unserviceable condenser coils from the existing system of 1.5/ 2.0 TR capacity of type split type AC unit after decanning refrigerent gas from the system to empty cylinder, disconnecting all electrical connections, flair nuts, valves and shut down all preventive valves properly & supply and replacing with new condenser coils (as per existing size and specification) including necessary fixing arrangement and connect all electrical and safety protection devices to the existing system and flushing the whole system by nitrogen, leak testing by 200 PSI nitrogen pressure holding of 48 hours, charging of decanning refrigerent to the system and charging of additional refrigerent as required, commisioning and testing complete all as specified and as directed. |
| 75 | Cleaning the cooling coil and condensor with the help of compressed Nitrogen inner side of the copper tube for flushing out all sludge and oil deposited in the copper tube and M&L for charging of refrigerant as required including replacement of strainer and finding out the leakage, brushing the same, testing for Split AC of 1.5/2.0 TR complete all as specified and as directed. |
| 76 | M&L for disconnecting defective indoor unit of split AC capacity 2 TR and replacing the same with new indoor unit in position fixing in original position (as per existing and compaitable to existing make) complete all as specified and as directed. |
| 77 | M&L for disconnecting defective outdoor unit of split AC capacity 2 TR and replacing the same with new outdoor unit including compressor in position fixing in original position (as per existing and compaitable to existing make) complete all as specified and as directed. |
| 78 | M&L for disconnecting defective indoor unit of split AC capacity 1.5 TR and replacing the same with new indoor unit in position fixing in original position (as per existing and compaitable to existing make) complete all as specified and as directed. |
| 79 | M&L for disconnecting defective outdoor unit of split AC capacity 1.5 TR and replacing the same with new outdoor unit including compressor in position fixing in original position (as per existing and compaitable to existing make) complete all as specified and as directed. |
| 80 | S&F in repairs MCB protected Power Unit with 16 - 25 Amp MCB, Motor Starter, Socket and Plug Top with indicating light complete all as specified and as directed.Make: North West/ Havells /Anchor or equivalent as approved by GE |
| 81 | M&L for charging of Refrigerant of R-22 (CFC based/Non CFC Based) in Split / AC, Water Cooler and Refrigerator complete all as specified and as directed. |
| 82 | M&L for charging of Refrigerant of R-32 (CFC based/Non CFC Based) in Split / AC, Water Cooler and Refrigerator complete all as specified and as directed. |
| 83 | S&F PVC flexible hose pipe 20 mm for water drain out line dually clamped on wall complete all as specified and as directed. |
| 84 | S&F in repairs PCB kit for indoor unit of inverter type Split Ac of capacity 1.5 T/2.0TR suitable (Make: Voltas/LG or equivalent as approved by GE) complete all as specified and as directed. |
| 85 | S&F in repairs PCB kit for outdoor unit of inverter type Split Ac of capacity 1.5 T/2.0TR suitable (Make: Voltas/LG or equivalent as approved by GE) complete all as specified and as directed. |
| 86 | S&F in repairs compressor for Inverter type Split type AC of capacity 1.5 TR five star as supllied by OEM complete all as specified and as directed. |
| 87 | S&F in repairs compressor for Inverter type Split type AC of capacity 2.0 TR five star as supllied by OEM complete all as specified and as directed. |
| 88 | Taking down ceiling fan of any type, any make and any sweep for repairing, opening the body and blade, checking for repalcement of unserviceable spares, cleaning, overoiling, greasing, replacement of unserviceable spare by new one, re-assembling of all components in original position, testing and hanging up the same complete all as specified and as directed.Note : New spare parts required shall be measured and paid seperately. |
| 89 | Supply only MS split pin size 2 \\" x 1/8 \\" for ceiling fan of 1200/1400mm Sweep complete all as specified and as directed. |
| 90 | Supply only Hanging bolt with nut of size 3/8\\" x 3 1/2 \\" for ceiling fan of 1200/1400mm Sweep complete all as specified and as directed. |
| 91 | Supply only Rubber bush of size 1 1/2 \\" dia x 1\\" thick for ceiling fan of 1200/1400mm Sweep complete all as specified and as directed. |
| 92 | Supply only Ball bearing of size 6201/6202/6203 for ceiling fan of 1200/1400mm Sweep complete all as specified and as directed. Make : TATA/SKF/NBC or equivalent as approved by GE |
| 93 | Supply only Metal bush bearing for ceiling fan of 1200/1400mm Sweep complete all as specified and as directed.Make : TATA/SKF/NBC or equivalent as approved by GE |
| 94 | M&L for Rewinding of ceiling fan, 1200/1400 mm sweep with synthetic enamel copper wire including insulation of starter with polyster paper/manllex paper with cotontak binding, heat varnished and complete all as specified and as directed. |
| 95 | Taking down exhaust fan of any type, any make and any sweep for repairing, opening the body including blade, checking for repalcement of unserviceable spares,cleaning, oiling, greasing including replacement of unserviceable spare by new one, painting, re-assembling of all components in original position, testing and hanging up the same complete all as specified and as directed.Note : New spare parts required for replacement shall be measured and paid seperately as 'Supply only\\" |
| 96 | Supply only Ball bearing 2001/ 2002/ 2003 for exhaust fans complete all as specified and as directed. Make : TATA/SKF/NBC or equivalent as approved by GE |
| 97 | Supply only Metal bush bearing for exhaust fans complete all as specified and as directed. Make : TATA/SKF/NBC or equivalent as approved by GE |
| 98 | S&F in repairs 2.5 mfd capacitor complete all as specified and as directed.MAKE- Universal/Tibcon/Elcap or equivalent as approved by GE |
| 99 | All as per BOQ Serial item No 96 above but 3.5 mfd capacity complete all as specified and as directed. |
| 100 | M&L for Rewinding of Exhaust fan, 230-300 mm sweep with synthetic enamel copper wire including insulation of starter with polyster paper/manllex paper with cotontak binding, heat varnished complete all as specified and as directed. |
| 101 | All as per BOQ Serial item No 98 above but for exhaust fan of sweep exc 450 mm complete all as specified and as directed. |
| 102 | Taking down cabin fan/wall mounted fan of any type, any make, by opening of body carefully checking for repalcement of unserviceable spares, including replacement of spares by new one, re-assembling of all components in original position, cleaning, oiling greasing, testing and fixed in original position complete all as specified and as directed.Note : New spare parts required for replacement shall be measured and paid seperately as 'Supply only\\" |
| 103 | Supply only Ball bearing size 2601 quality for cabin fan/wall mounted fan complete all as specified and as directed. Make : TATA/SKF or equivalent as approved by GE |
| 104 | Supply only Metal bush bearing for cabin fan/wall mounted fan complete all as specified and as directed. Make : TATA/SKF or equivalent as approved by GE |
| 105 | M&L for painting of ceiling fan of size 1200/1400 mm sweep with down rod upto 2.00 mtr long with two coats of synthetic enamel white paint including preparation old painted surface including writing of MES No with letters n exc 15cm height complete all as specified and as directed. |
| 106 | S&F in repairs for MS clamps made out of 50x6mm flat iron suitable for hanging of ceiling fan on pipe including necessary cutting, threading, drilling fixing arrangement split pin, nuts bolts washer etc complete all as specified and as directed. |
| 107 | S&F in repairs for ceiling fan hanging clamp made of MS rod bent ot 'S' shape complete all as specified and as directed. |
| 108 | S&F in repairs down rod suitable for Celing fan of between 2.0 mtrs - 3.0 mtrs, medium grade M.S. Pipe duly drilled, screwed and painted with one coat of rdoxide metal primer and two coats of high gloss white synthetic enamel paint complete with nut, bolt etc complete all as specified and as directed. |
| 109 | S&F in repairs M.S. galvanised louvers suitable for exhust fan of size 230-300 mm sweep complete all as specified and as directed. |
| 110 | Taking down geyser and scraping, cleaning including brazing of inner vessel of the geyser at leakage point to made it leak proof including testing pressure and assembling of all component refixing complete for 25 Ltr capacity complete all as specified and as directed. |
| 111 | All as per BOQ Serial item No 108 above but for 15 Ltr capacity complete all as specified and as directed. |
| 112 | S&F in repairs heating elements of 2 KW 230 V suitable for water heater of any type including connection with suitable cable complete all as specified and as directed. |
| 113 | S&F in repairs suitable for five star rating, special heating elements of 2 KW 230 V suitable for water heater of any type including connection with suitable cable complete all as specified and as directed. |
| 114 | S&F in repairs thermostat switch of geyser 230 V, 30 degree to 90 degree centigrade temp range to be set at 70 degree to 50 degree centi grade suitable for water heater complete all as specified and as directed. Make-Venus/Bajaj/Theeta or equivalent as approved by GE |
| 115 | S&F in repairs bottom cover, made out of MS sheet 16 guage, duly paintedwith two coats of white synthetic enamel paint both side over a coat of red oxide zinc chrome primer for 25 Ltr capacity geyser complete all as specified and as directed. |
| 116 | All as per BOQ Serial item No 113 above but for 15 Ltr capacity complete all as specified and as directed. |
| 117 | S&F in repairs top cover made out of MS sheet 16 guage, duly painted with two coats of white synthetic enamel paint both side over a coat of red oxide zinc chrome primer of 25 Ltr capacity geyser complete all as specified and as directed. |
| 118 | All as per BOQ Serial item No 115 above but for 15 Ltr capacity complete all as specified and as directed. |
| 119 | S&F in repairs MS flange for Geyser of 25/15 ltr capcity complete all as specified and as directed. |
| 120 | S&F in repairs Split cover made out of 16 guage sheet duly painted with synthetic enamel paint suitable for water heater of 25 ltr capacity complete all as specified and as directed. |
| 121 | All as per BOQ Serial item No 118 above but for 15 Ltr capacity complete all as specified and as directed. |
| 122 | S&F in repairs indicating lamp, 230 V, flush type, rectangular, red indicator suitalbe for water heaters complete all as specified and as directed. |
| 123 | S&F in repairs 450mm long brass CP braided hoses for hot water with 2 nuts without nipple suitable for geysers complete all as specified and as directed. |
| 124 | S&F in repairs PVC inlet connector pipe 450mm long long for geyser, heavy duty, with brass coupling both ends to fix inlet of geyser complete all as specified and as directed. Make : Prayag/Polytuf or equivalent as approved by GE |
| 125 | S&F in replacement for apparatus plate , asembly suitable for water storage heater of 25 ltrs capacity complete all as specified and as directed. |
| 126 | All as per BOQ Serial item No 123 above but for 15 Ltr capacity complete all as specified and as directed. |
| 127 | S&F in repairs copper inner tank of 25 Ltr capacity geyser of heavy guage to withstand pressure upto 8 bars including testing pressure complete all as specified and as directed |
| 128 | All as per BOQ Serial item No. 125 above but of capcity 15 Ltrs. complete all as specified and as directed. |
| 129 | S&F in repairs PVC insulated flexible copper conductor cable 2.5 Sqmm 4 core , 1100 Volts grade conforming to IS 694 (FRLSH) complete all as specified and as directed. |
| 130 | S&F in repairs split type bolt MS 12mm dia, 10cm long grouted with cement mortar suitable for fixing new geyser including making good to distrubed surface complete all as specified and as directed. |
| 131 | Preparation to old painted surface of storage water heater of 25 ltr capacity and M&L for painting with two coats of synthetic enamel paint (white) by using spray gun complete all as specified and as directed. |
| 132 | All as per BOQ Serial item No 129 above but for 15 Ltr capacity complete all as specified and as directed. |
| 133 | S&F in repairs piano switch,16/ 20 Amp, flush type, one way complete all as specified and as directed. |
| 134 | S&F in repairs socket 16 Amp, 3 pin, flush type complete all as specified and as directed. |
| 135 | S&F in repairs angle stop valve, brass chronium plated, 15mm bore screwed down high pressure with crutch or butter fly handle screwed both ends fixed to GI pipe complete all as specified and as directed. |
| 136 | S&F in repairs PCB Kit for BLDC Fan of sweep 1200mm as supplied by OEM celing fan complete all as specified and as directed. Make: Crompton/Atomberge or equivalent as approved by GE. |
| 137 | S&F in repairs PCB Kit for BLDC Fan of sweep 1400mm as supplied by OEM celing fan complete all as specified and as directed. (Make: Crompton/Atomberge or equivalent as approved by GE) Please Enable Macros to View BoQ information |