| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.All kinds of soil. |
| 2 | Dumping of stone including cost of stones in horizontal on level. |
| 3 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 4 | Random rubble masonry with hard stone in foundation and plinth includinglevelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 5 | Providing & fixing upto floor five level precast cement concrete solid blocks including hoisting and setting in position in cement mortar 1:3 (1cement:3 coarse sand), cost of required centring, shuttering and curing complete. 1:3:6 (1 cement : 3 coarse sand : 6 graded crushed stone aggregate 20 mm nominal size) |
| 6 | Carriage of material from source to site of work by MT including loading, unloading and stacking complete. Cement/Steel……………… 1.0 kms |
| 7 | Sand………………………….20 kms |
| 8 | Stone aggregate………………20kms |
| 9 | Soling Stone………….20 kms |
| 10 | Earth………………7.0 kms |
| 11 | Earthwork in excavation by mechanical means (Hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5min width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge. All kinds of soil |
| 12 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil |
| 13 | Dumping of stone including cost of stones in horizontal on level. |
| 14 | Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 15 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 16 | Reinforcement of R.C.C work in plinth band incl. straightening, cutting, bending, placing in position and binding all complete. TMT bars |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form for:a) Foundations: footings, bases of columns etc. for mass concrete |
| 18 | Lintels, beams, plinth beams, girders, bressumers and centilevers. |
| 19 | Suspended floors, roofs, landings, balconies and access platform. |
| 20 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 21 | Edges of slabs and breaks in floors and walls. Under 20 cms wide |
| 22 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. Layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering lead upto 50m and lift upto 1.5m. |
| 23 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement :6 coarse sand:12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 24 | Providing & fixing upto floor five level precast cement concrete solid blocks including hoisting and setting in position in cement mortar 1:3 (1cement:3 coarse sand), cost of required centring, shuttering and curing complete. 1:3:6 (1 cement : 3 coarse sand : 6 graded crushed stone aggregate 20 mm nominal size) |
| 25 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Second class kail wood |
| 26 | Providing and fixing ISI marked flush door shutters conforming to IS:2202 (PartI) non-decorative type, core of block board construction with frame of 1st class hardwood and well matched commercial 3ply veneering with vertical grainsor cross bands and face veneers on both faces of shutters : 35mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 27 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to bemeasured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : Float glass panes 4 mm thick glass pane (weight not less than 10kg/sqm). |
| 28 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws Second class teak wood35 mm thick |
| 29 | French spirit polishing with Two or more coats on new works including a coat of wood filler |
| 30 | 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 4 ( 1 cement : 4 fine sand) |
| 31 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacture, over the plastered wall surface to prepare the surface even and smooth complete. |
| 32 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including priming coat with cement primer |
| 33 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface Water thinnable cement primer |
| 34 | Finishing walls with water proofing cement paint of required shade New work (two or more coats) applied @3.84 kg/1Osqm |
| 35 | Providing and fixing bright finished brass handles with screws etc. complete:125 mm |
| 36 | Providing and fixing bright finished brass tower bolts (barrel type) with necessaryscrews etc. complete : 250x10 mm |
| 37 | Providing and fixing bright finished brass door latch with necessary screws etc.complete : 300x16x5 mm |
| 38 | Cement concrete flooring 1:2:4 ( 1cement:2coarse sand:4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate. Crushed |
| 39 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 40 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. |
| 41 | Providing and fixing white vitreous china pedestal type water closet ( European type) with seat and lid , 10 litre low level white vitreous china flushing cistern and CP flush with fittings, C. I./M.S. brackets 40mm bend diameter flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required: W.C. pan with lSI marked white solid plastic seat and lid. with white vitreous china flushing cistern & C. P. flush bend. |
| 42 | Providing and fixing wash basin with C.I.brackets,15mm dia C P Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a)White Vitreous China Wash basin size 550 x 400mm with a15mm C P Brass single hole basin mixer |
| 43 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings |
| 44 | Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. |
| 45 | Providing & fixing 3 layer PP-R (Poly propylene Random copolymer) pipes SOR 7.4 UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropytene random fitings 1/C fixing the pipe with clamps at 1.00m spacing. This includes testing of joints complete as per direction of Engineer-in-charge. (concealed work including cutting chases and making good the walls etc.) Pn-16 pipe, 25mm 00 |
| 46 | Pn-16 pipe, 32mm 00 |
| 47 | Providing and fixing PVC waste pipe of required dia including bends, Tee door bend, L bend trap jointed with addisive material ISI marked like prince, vector or equivalent brand all complete job. 110mm dia bore |
| 48 | 90mm dia bore |
| 49 | Providing and fixing of material for the insulation of pipe with nitrile tube, tapping with cello tape for inner wall fittings complete job including carraige 19mm thick, 50mm dia (OD) (PPR 25mm) |
| 50 | Providing & fixing heat tape 33 watt on PPR pipes made of denforced or chromelox or equivalent make as approved by engineer in charge, complete job. |
| 51 | Providing and fixing of material for the insulation of pipe with nitrile tube, tapping with cello tape, Rockwood 6 inch per side, wire mesh, polythene, tapping with cello tape aluminium sheet 26 gauge cladding with dia complete job including carraige 19 mm thick, 50mm dia (OD) (PPR Pipe 32 mm) |
| 52 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 |
| 53 | Providing and fixing PTMT towel rail complete with brackets fixed to woodencleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms. |
| 54 | Providing and fixing toilet paper holder C.P. brass |
| 55 | Providing and fixing C .P .brass bib cock of approved quality conforming to IS : 8931 15mm nominal bore. |
| 56 | Providing and fixing C.P.brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15mm nominal bore. |
| 57 | Providing & fixing ball valve (PPR) of approved quality complete 32mm |
| 58 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. 15 mm nominal dia |
| 59 | Providing and fixing 600 x 450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete |
| 60 | Providing and fixing 100 mm sand cast iron grating for gully, floor or Nahani trap. |
| 61 | Providing and fixing 25 ltr. Geyser including all complete job. |
| 62 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 63 | Providing and fixing of material for the insulation of water storage tank with nitrile sheet, tapping with cello tape, Rockwood 6 inch per side, wire mesh, polythene, aluminium sheet 26 gauge cladding with dia complete job 19 mm thick nitrile sheet. |
| 64 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded |
| 65 | Carriage of material from source to site of work by MT including loading, unloading and stacking complete.Cement / steel …................... 1.0 km |
| 66 | Sand …................... 20 kms |
| 67 | Stone aggregate………………20kms |
| 68 | Soling Stone………….20 kms |
| 69 | Earth…......................... 7.0 kms |
| 70 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. |
| 71 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 72 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required .2 x 2.5 Sq.mm + 1 x 2.5 Sq.mm earth wire |
| 73 | 2 x 16 sqmm + 1x 10 Sq. mm earth wire |
| 74 | 2 x 10 Sq.mm + 1 x 6 Sq.mm earth wire |
| 75 | Supplying and fixing following modular type switch/socket on the existing switch box cover including connections etc. as required.5/6 A switch |
| 76 | 3 pin 5/6 socket outlet |
| 77 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 78 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 Nos. 3 pin 5/6 amps modular socket outlet and 2 nos .5/6 amps modular switch, connection etc. as required |
| 79 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 amps & 15/16 amps. modular socket outlet and 15/16 amps modular switch connection etc. as required. |
| 80 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way ( 4+ 24) Double Door |
| 81 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 6/16 amp. |
| 82 | Supply and fixing of following sizes of PVC conduit alongwith accessories in surface/recessed including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 83 | Supplying and fixing of following rating 240/415 Volt's \\"C\\" Series miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning (Above to 32 Amp.).TPN 63 Amp |
| 84 | Supplying and fixing of following electrical items suitable for operating on 240/230Volts AC, 50 Hz supply. including connections etc. as required. Exhaust fan 300 mm size (Heavyduty) CG transair or equivalant approved make |
| 85 | Sypplying & fixing LED type down lighter 15 watt LD- 95- 141-xxx- 65 G1 wipro or equivalent. |
| 86 | Providing and fixing Automatic timer 30 - 33 watt including all complete job. |
| 87 | Providing and fixing Conceal Box Please Enable Macros to View BoQ information |