| Sl. No. | Item Description |
| 1 | SITC of Horizontal type, self priming non clog sewage pump, single stage Pump, with CI Impeller, EN8 shaft & Sleeve, with suitable suction & Delivery LPM 1032 at 10 Mtr, Head up to 20 Mtr coupled with 3 phase Induction motor 5 HP, TEFC, 440 Volt, 1450 RPM with coupling guard, Base frame with AVM etc complete as required. |
| 2 | SITC of Electrical Horizontal centrifugal pump set with non clog /mf impeller to handle storm / mixed / sewage water with the following specificatio:- (a) Discharge - 750 m3/hr at 10 m head (b) Delivery and Suction size 350/350 mm Motor:- Coupled with 50 HP/ 37 KW, 990 RPM, IE-2, S1 class energy effcient BEE model electric motor mounted on a common base frame, 415 volt, 50 Hz, a,c, electric supply Material of construction : - Casing - C. I, Impeller - C I, Shaft - 40C8, Pump type:- as per manufacture design complete with coupling, coupling guard and foundation bolts etc. |
| 3 | SITC of Electrical Horizontal centrifugal pump set with non clog /mf impeller to handle storm / mixed / sewage water with the following specificatio:- . (a) Discharge - 1620 m3/hr at 8 m head . (b) Delivery and Suction size 350/400 mm . Motor:- Coupled with 75 HP/ 55 KW, 750 RPM, IE-2, S1 class energy effcient BEE model electric motor mounted on a common base frame, 415 volt, 50 Hz, a,c, electric supply Material of construction : - Casing - C. I, Impeller - C I, Shaft - 40C8, . Pump type:- as per manufacture design complete with coupling, coupling guard and foundation bolts etc. |
| 4 | Supply of Submersible Sewage Pumps 7.5 HP/5.5 KW/3 Phase/ 1450 RPM/head 15 mtr, discharge 950 LPM, 100 mm Hose Outlet, Solid Handling: 75 mm Casing : Cast Iron ASTM A48 Class 30 (FG200) Impeller: Cast Iron ASTM A48 Class 30 (FG 200) Shaft: 431 Stainless Steel, Hardware: 304 Stainless Steel \\"O\\" Rings: Nitride Rubber Mech, Seals: TC/TC (Upper & Lower) Cable: Waterproof/oil proof EPR insulated, double sheethed copper conductor flexible cable fitted with strai relief grip, 15 mtr EPR cable 6 core. (4 core of 2.5 sq. mm + 2 core of 1 sq. mm.) |
| 5 | Supply of Submersible Sewage Pumps 15 HP/11 KW/3 Phase/ 1450 RPM, head 15 mtr discharge 2700 LPM, 150 mm Hose Outlet, Solid Handling: 100 mm Casing : Cast Iron ASTM A48 Class 30 (FG200) Impeller: Cast Iron ASTM A48 Class 30 (FG 200) Shaft: 431 Stainless Steel, Hardware: 304 Stainless Steel \\"O\\" Rings: Nitride Rubber Mech, Seals: TC/TC (Upper & Lower) Cable: Waterproof/oil proof EPR insulated, double sheethed copper conductor flexible cable fitted with strain relief grip, 15 mtr length of 7 core 4 core of 4 sq. mm + 2 core of 1 sq. mm (9 core cable) |
| 6 | Installation testing & commissioning of Submersible Sewage Pumps 7.5 HP/5.5 KW to 15 HP/11 KW/3 Phase etc complete as required. |
| 7 | Providing, laying , testing & commissioning of 'C' class heavy duty MS pipe confirming to IS 3589/IS 1239 including welding fittings like elbows, tees, flanges, tapers, nut bolts, gaskets etc. and fixing the pipe on the wall/celing with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as reqd. (a) 80 mm dia |
| 8 | 100mm Dia |
| 9 | 150mm Dia |
| 10 | (A) P&F / Replacement of M.S. Black pipe (9.5 mm thickness) confirming to IS:3589 with required nut bolts & packing sheet etc complete as required. (A) 300 mm dia (9.5 mm thick) |
| 11 | (B) 350 mm dia (9.5 mm thick) |
| 12 | (C) 400 mm dia (9.5 mm thick) |
| 13 | (D) 500 mm dia (9.5 mm thick) |
| 14 | Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : (a) SV 80mm dia |
| 15 | (b) SV 100mm dia |
| 16 | (c) SV 150mm dia |
| 17 | Replacement of Non Rising Spindle sluice valve of CI Body with Wedge, Bronze ring confirming to IS 14846 & SS IS:6603 (ISI Marked), PN 1.6 complete as required : SV 300mm |
| 18 | SV 350mm |
| 19 | SV 400mm |
| 20 | SV 500mm |
| 21 | Replacement of swing type Non Return Valve of CI Body with Door, bronze to Rubber rings confirming to IS 5312 (Part 1 Part 2), PN 1.6 complete as required : (A) 80mm |
| 22 | (B) NRV 100 MM |
| 23 | (C) NRV 150 MM |
| 24 | (D) NRV 300 MM |
| 25 | (E) NRV 350 MM |
| 26 | (F) NRV 400 MM |
| 27 | (G) NRV 500 MM |
| 28 | Providing and fixing of M.S. Flange with required nut bolts & packing sheet etc. complete as required of following Dia. (a) 80 mm (10 mm thickness) |
| 29 | (b) 100 mm (10 mm thickness) |
| 30 | (c) 150 mm (10 mm thickness) |
| 31 | (d) 300 mm (25 mm thickness) |
| 32 | (e) 350 mm (25 mm thickness) |
| 33 | (f) 400 mm (25 mm thickness) |
| 34 | (f) 500 mm (25 mm thickness) |
| 35 | Providing and fixing of M.S. Blank Flange with required nut bolts & packing sheet etc. complete as required of following Dia. (a) 300 mm (25 mm thickness) |
| 36 | Providing and fixing of M.S. Blank Flange with required nut bolts & packing sheet etc. complete as required of following Dia. (a) 500 mm (25 mm thickness) |
| 37 | Providing and fixing of M.S. Bend with required nut bolts & packing sheet etc. complete as required of following Dia (a) 300 mm (8 mm thick) length 0.5 m |
| 38 | (b) 350 mm (8 mm thick), length 0.75 m |
| 39 | (b) 400 mm (8 mm thick), length 0.75 m |
| 40 | (c) 500 mm (10 mm thick), length 1 m |
| 41 | Providing & Fixing of MS reducer 300 mm x 200 mm, 10 mm thick, approx 0.5 mtrBar Screen made out of MS Angle length / required length at site, with suitable size , with suitable size nut, bolt, packing sheet etc, all as directed at site. |
| 42 | Providing & Fixing of MS reducer 150 mm x 300 mm, 10 mm thick, approx. 0.5 mtr length / required length at site, with suitable size , with suitable size nut, bolt, packing sheet etc, all as directed at site. |
| 43 | Providing & Fixing of MS Bar Screen made out of MS Angle size (75 mm x 75 mm) and center covered with MS Sq bar size 18 mm duty welded with center to center distance 35 mm and duly welded. Work also includes complete Bar Screen duly Painted with enamel paint. Bar Screen duly fixed in side wall using Mortar, tools and tackles etc complete as required. (Quantity in Sq. Feet) complete as required. |
| 44 | Providing & Fixing of MS Platform made out of MS Girder size 8\\" x 4\\" (200 mm x 100 mm) fixing in back sides and center supporting with MS angle iron size 50 x 50 x 6 mm with cross welding and fixing of MS chequred sheet of 7 mm thickness on top side of MS platform, back side platform duly welded MS railing with 2\\" dia MS pipe with 3'6\\" height to be fixed at site. complete plate and railing duly Painted with enamel paints. (Quantity in Sq. Feet) |
| 45 | Providing and fixing of 600 mm sweep Air circulator complete with blades, jaal workable on 220/240 volts AS Supply etc, as reqd. |
| 46 | Supply of corrugated & chequered rubber mat for electrical purpose exceeding IS: 5424/69 Black or red in 1 M X 2 M of size. 25 mm thickness |
| 47 | Providing and fixing ABC (aluminium phosphate) power type fire extinguisher of 6kgs capacity complete in all respect with ISI marked i/c fixing arrangement etc as required. |
| 48 | Providing and fixing 4.5 kg CO2 type fire extinguisher, squeeze grip type trolley wheel as well as mounted type complete in all respect with ISI marked i/c fixing arrangement etc as required. |
| 49 | 16 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 50 | Supply and fabrication of pole protection system made up of 8SWG steel wire mesh of size25mmx75mm rectangular with 50mmx50mmx6mm MS angle iron for supporting the mesh and grounding the protection system in suitable quality of CC etc as reqd. |
| 51 | Automatic Power Factor Correction (APFC) System Supply, Installation, testing and commissioning of Automatic Power Factor Correction (APFC) panel, indoor type floor mounted free standing totally enclosed, extendable, IP 42, of following capacity for 3 phase, 415 V + 10 %, 50 Hz AC System for Ambient temperature -5°C to +40°C, fabricated in compartmentalised designed made of CRCA sheet steel of 2.0mm thick for framework & covers, 3 mm thick for gland plate i/c cleaning & finishing complete with 9 tank process for powder coated of approved shade ( RAL 7032-Siemens Gray or as approved by Engineer-in-Charge), having front section (switch gear and control accessories) and rear section capacitor and reactor, front and rear access, having suitable current carrying capacity, extensible TPN Aluminium alloy bus bar of high conductivity, DMC/SMC bus bar supports, |
| 52 | bottom base channel of MS Section, fabrication shall be done in transportable section, entire panel shall have common copper earth bar of minimum size of 25mm x 5mm with 2 nos. earth studs, the earth terminals provided on the body of capacitor bank shall also be bonded to the main capacitor panel earth bus with 2 nos. 8 SWG or 6 SWG GI earth wires/ equivalent size of copper conductor cable, forced ventilation for maintaining temperature rise not more than 5°C from ambient, interconnections, connections with 14% detuned reactor and heavy duty 525 V ISI marked Impregnated MPP(Metalized Polypropylene) Capacitor (IS 13340 Part -1 & 2) APFC Panel shall be in compliance with IS :16636 & CPWD Specifications etc. as per below details. |
| 53 | (A) IncomersSuitable capacity MCCB Microprocessor base with O/C, S/C, E/L release of TPN 50KA breaking capacity (Ics=Icu), ON, OFF, Trip, R, Y, B - LED Indicating Lamp set along with required Instruments and accessories with extended rotary handle and door interlocking arrangement. Current rating of The Incomer in ampere shall be APFC Panel rating in KVAR x 1.4 x 1.5 or Nearest higher standards rating. |
| 54 | (B) Instruments & Indicationsi) 3-Phase current sensing APFC microprocessor relay/controller , advance 8/12 stages (8 stages for capacity below 100 KVAR and 12 stages 100 KVAR & above) with Communication Ethernet/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge and having display of Phase wise V, A, PF, Cos-Phi, Kw, KVA, KVAR, THD-V , THD-I, harmonics up to 31 level. 3 nos of dual core CT's accuracy class 1, 15VA at incomer of PCC Panel for APFC relay. ii) Auto Manual Selector switch, auxiliary contactors with timer for delay in manual mode. iii) Digital Multi function meter with LED Display for V, A, PF, KW, KVA, KVAR, THD-V & I, Frequency. iv) Suitable rating control transformer shall be provided for control and indication circuit. v) All components like control transformer, meter, relay and indicating lamp shall be protected by using suitable rating individual MCB's. vi) Wiring of the control circuit shall be done by using 2.5 sq mm, FRLS/HFFR 1100 V grade, PVC insulated multi stranded copper control wire. |
| 55 | (C) Bus Bars 1.3 Amp per Sq.mm,TPN, Electrolytic grade Aluminium bus bar of capacity 1.25 times of incomer rating as per CPWD specification. |
| 56 | (D) Outgoings (APFC Section) Selection of the capacitors combinations shall be for continuous rating and each capacitor bank shall have suitable capacity Heavy Duty ISI Marked Capacitor, capacitor duty contactor,the capacitor shall be mounted on channel with base of perforated M S Powder coated sheet, connections inter connections etc. and other features as per CPWD Specifications and relevant IS Code having following: (i) Capacitor bank ratings & stages shall be as per the technical specifications sheet of NIT. |
| 57 | (ii) Capacitor will be MPP self healing type with discharge resistor, pressure release mechanism. (iii) Since Capacitor Voltage is 525 Volts, thus higher KVAR has to be considered to get rated output at 415 Volts. (iv) 14% Detuned Reactor of class H insulation & 150% linearity in series with Capacitor. (Note: Technical specifications sheet for selection of the capacitors combinations shall be provided by the NIT Approving Authority with due consideration of number of capacitors i.e. 1 KVAR, 2 KVAR, 3 KVAR, 5 KVAR, 10 KVAR.....for smooth correction). (a) 100 KVAR |
| 58 | Supply of C Channel 40x75x40 required for fixing of illuminated signage board etc. complete as reqd. |
| 59 | Supply of XLPE insulated PVC sheathed Al. Cond. Armoured cable of 1.1kV grade conforming to IS-7098 Part-I of following size, (a) 2 x 25 sqmm |
| 60 | (b) 3.5 x 70 sqmm |
| 61 | (C) 3.5C*120 sqmm |
| 62 | (d) 3.5C*400 sqmm |
| 63 | Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm |
| 64 | Providing valleys of 90 cm wide overall in plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete : (a) 1.60 mm thick with zinc coating not less than 350 gm/m² |
| 65 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 66 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm |
| 67 | Above 35 sq. mm and upto 95 sq. mm |
| 68 | Above 95 sq. mm and upto 185 sq. mm |
| 69 | Above 185 sq. mm and upto 400 sq. mm |
| 70 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm |
| 71 | Above 35 sq. mm and upto 95 sq. mm |
| 72 | Above 85 sq. mm and upto 185 sq. mm |
| 73 | Above 185 sq. mm and upto 400 sq. mm |
| 74 | Laying and fixing of one number PVC insulated andPVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. (a) Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 75 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 76 | Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
| 77 | Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
| 78 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 79 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 80 | Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
| 81 | Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
| 82 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (a) 2 X 25 sq. mm (22mm) |
| 83 | (b) 3½ X 70 sq. mm (38mm) |
| 84 | (c) 3½ X 120 sq. mm (45mm) |
| 85 | (d) 3½ X 400 sq. mm (82mm) |
| 86 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 87 | 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 88 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. |
| 89 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 90 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 91 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 92 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 93 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 94 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 95 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 96 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required. (a) 300 mm width X 50 mm depth X 1.6 mm thickness |
| 97 | Supplying & fixing PVC insulated PVC sheathed copper conductor submersible flat cable ISI Marked in existing metal/ HDPE / PVC/ pipe/ in bore well/ in sump including fixing the cable to GI/HDPE pipe with suitable cable tags of following sizes etc. complete as required. (a) 3 Core 6 Sq mm Flat Cable |
| 98 | (b) Double sheathed PVC copper conductor cable 2.5x4 sq.mm |
| 99 | (b) Dual PVC Round Type Copper Flexible Cable 7 Core 4 Sqmm + 2 Core 1 Sqmm |
| 100 | Providing and laying in position ready mixed or site batched design mixcement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Concrete of M30 grade with minimum cement content of 350 kg /cum |
| 101 | Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 102 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Cold twisted bars |
| 103 | Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 104 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate)finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate |
| 105 | Cement plaster askirting upto 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement .18 mm thick |
| 106 | 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 107 | Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m : Ordinary rock :Pipes, cables exceeding 300 mm dia but not exceeding 600 mm dia |
| 108 | Fabrication,Supplying,Installation,testing,Commissioning of 12 mtr high mast System with its accessories ,Mast shaft shall be in one section , hot dip galvanized 4mm thick(Single dip ) inside & out sides &suitable for wind velocity as per IS 875 part3 .There shall be in longitudinal seam weld per section and No circumferential weld. It should also included accessories For High Mast head frame ,2 point suspension system, 5*2.5 sqmm Cu conductor with steel wire rope 5mm dia. (7/19construction) single drum winch ,galvanized lantern carriage arrangement suitable for 4/6 Nos. Flood Light luminaries symmetrically And its control gears boxes and lighting finial ,the mast shall have integral type manual tool mounted at the base compartment of its raising and lowering operation with foundation bolts and Anchor plate and control panel housing suitable RCC (1:2:4) shallow foundation of size 1m(L) x 1m wide and 2m deep i/c excavation of earth, |
| 109 | providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia -2100mm long (approx.) - 16 nos.and reinforcement of cold twisted bar of 8 mm dia - 3700 mm (approx.) - 13 nos. (with 150 mm spacing) as required with positioning of foundation bolts and providing DWC HDPE pipe for cable entry & exit as required for the high mast considering The safe soil bearing capacity at site as 10T/sqm at 2mts. Depth with all material i/c 4Nos S.P MCB,1 No. Double pole 16Amp.MCB etc as reqd. Logo/Name of manufacturer shall be either embossed or Rivited plate on the pole. Galvanization as per relevant IS. |
| 110 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt)Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (a) 100 watt |
| 111 | (a) 50 watt |
| 112 | S/I/T/C of 3 Core, 4 Sqmm. Electrical wire for Air Conditioner |
| 113 | Supply installation testing and commissioning of double girder , I beam type, 3 Ton capacity, approx span 6.7 mtr, 15 to 21 mtr length with the following specification:- |
| 114 | Bridge: The Main Girder ISMB OR plate Stiffeners fabricated box type construction design to sustain all stresses arising due to vertical & lateral forces with impact to which they are subjected. The maximum deflection of the main girder is limited to 1/750 of span of live loads including the weight of the trolley or hoist. |
| 115 | Gear Box: Single Helical Reduction mounting on anti friction ball /Roller bearing splash lubrication CI/Fabricated as per IS 226/2062 according to design requirements. Pinions are made of EN -24 Gear And shafts are made of EN-8&EN-9 Material according to design requirement |
| 116 | Main hoisting Gear Box: HELICAL TYPE |
| 117 | Cross travel Gear Box: Geared Motor |
| 118 | Long travel Gear Box: Geared Motor x 2 |
| 119 | Motors: All crane duty standard make motor for Hoist, Cross Travel & Long travel. Sq.Cage type Motor as per IS-325 40%CDF CLF Insln. With IP 55 enclosures. International frame size fan cooled type / MZ frame size. |
| 120 | Main hoisting: 3 HP |
| 121 | Cross travel: 1 HP |
| 122 | Long travel: 0.5 Hp x 2 Nos (both side) |
| 123 | Brakes: Electro Magnetic DC DSIC (Only in main hoisting) |
| 124 | Control : Contactors, Step down transformers, MCB’s , Transformers, Fittings, etc. Will be provided in Control Panel |
| 125 | Limit switches: Main Hoisting – Geared Rotary type / Snap Action |
| 126 | Coupling: All coupling to be used in crane will be flexible gear coupling to Minimize dynamic deflections. |
| 127 | Wheel Assemblies: The Wheels of the Trolley & The end carriages shall be forged steel CN55 AND MN 75 (E-N-9) duly spin hardened to 300 BHN materials Double flanged straight tread type fitted with antifriction bearings with open gear Type Bearing Housing for the ease of maintenance.( For L.T. 200 mm. Total - 4 Nos) and ( For C.T. 120 mm Total - 4 Nos.) |
| 128 | Wire rope: Plough steel wires (as per IS-1835) rope with well lubricated fiber core of 6x36 construction. Rope shall conform to IS 2266. (to be tested for breaking load test certificate for Bearing load shall be furnished)Twisted wire rope in crane will be used.(For Main Hoisting- FMC/WRC 6x36 in 4 falls) Dia. 10 mm 4 falls mm. |
| 129 | Cables: All flexible copper cables tested to 1100V will move fitted Along with hoist unit |
| 130 | End stopper: Steel OR rubber stopper are provided on either side of the bring for motion of the trolley. All the buffer will employ springs for shock absorption. |
| 131 | Rope drum: Seam Less pipe/plate rolled suitable dia & suitable shell thickness to accommodate wire rope single layer/Double Groove layer as per IS-2062 |
| 132 | Steel: Steel confirming to IS- 2062 or equivalent is used in the manufacture of Main Load bearing. |
| 133 | Paint: Crane will be painted one coat of red oxide & two coat of epoxy paint. |
| 134 | Bottom hook assembly: According to IS 3177, Made of Trunnion. 2 sheaves and a single hook, supported on trunninon by thrust bearing, the hook shall be made of forged steel and to be mounted on platform, IP-55 Protection with plug in system of all Cables |
| 135 | Supply: 440V, 50 Hz, 3 Phase.,Control Voltage-110 V 50 HZ |
| 136 | Providing and fixing plain 16/0.20mm (0.50sqmm) twin circular flexible FRLS/HFFR PVC insulated, PVC sheathed copper conductor cable direct on the wall with PVC clips etc. as required. |
| 137 | Supplying, Installation, Testing & Commissioning of ‘Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. and consisting of the followings: |
| 138 | (A) Diesel Engine: Tourbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 0C, 50% RH & at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWD specifications. |
| 139 | (B) Engine mounted Instrument Panel fitted with and having digital dis Plate for following:(i) Start-stop switch with key(ii) Water temperature indication(iii) Lubrication oil pressure indication(iv) Lubrication oil temperature indication(v) Battery charging indication and Voltage indication(vi) RPM indication(vii) Over speed indication(viii) Low lubricantion Oil trip indication(ix) Engine Running Hours indication(x) Fuel Level |
| 140 | (C) Alternator: Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 0C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation. |
| 141 | (D) Base Frame & Foundation: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. |
| 142 | (E) FUEL TANK: Daily service fuel tank of suitable liters capacity as per CPWD Specifications, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. |
| 143 | (F) Exhaust System: Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor. |
| 144 | (G) Starting System: 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set. |
| 145 | (H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV + or better norms etc. and as per CPWD specifications |
| 146 | (I) AMF Panel: Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency, power (aluminium) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software, the panel shall be of DG Set OEM make etc. as per approved by Engineering in charge and including the following: |
| 147 | 1. Suitable numbers and appropriate capacity 4 pole motorised electrically operated draw out with cradle type 3 position ACB/ MCCB with electronic release for O/C & E/F and shunt trip. 2. Auto/Manual/Test/Off selector switch 3. Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay). 4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering 5. Energy analyser unit to indicate current, Voltage( LN & L_L), kW, kVA (Phase & Total), Frequency, KWH, PF. 6. LED Indicating lamps for load on mains and load on set 7. Fuse/ MCB for instruments 8. Battery charger, complete with transformer/ rectifier,.D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment. 9. Main supply failure monitor 10. Supply failure timer 11. Restoration timer 12. Control unit with three impulse automatic engine start/stop and failure to start lockout. 13. Impulse counter with locking and reset facility. 14. ON/OFF/Control circuit switch with indicator 15. Audio/Video annunciation for |
| 148 | (i) High water temperature (ii) Low lubricating oil pressure (iii) Engine over speed (iv) Engine fails to start (v) Full load/maximum load warning 16. Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories 17. Maintenance notification based on Engine Run Hour & due date. 18. Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel , interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the operation shall be provided by the contractor including all control wiring. (a) 250 KVA |
| 149 | Supply, installation, testing and commissioning of following capacity (continuous loading) 11/0.433 KV Delta/Star,step down, 3 Phase, 50 Hz, Dyn 11 vector group, Cast Resin / VPI (vacuum pressure impregnated) Dry Type, copper wound transformer (Electrolytic grade 99.9% pure copper, Core made of first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or better) AN (air natural) cooled transformer suitable for indoor applications with Offload Tap Changer/ On Load Tap Changer (OLTC) (upto 500 KVA offload and above 500 KVA On Load Tap Changer) on HV side having AVR relay and Remote Tap Changer Control (RTCC) for automatic sensing of incoming voltage, automatic operation of OLTC and facility for remote and manual operation of OLTC HV side in range of +5% to -15% in steps of 2.5%, insulation class F (minimum), suitable for environment conditions class E4, suitable for fire behaviour class F1,climate class-C1, having cable end boxes on HV side suitable for 3x300 sqmm XLPE cable of 11 KV grade with necessary hardware, clamps, lugs etc. for termination on HV/MV etc. for all transformers, bus trunking arrangement on LV side complete with all accessories and safety provisions as per relevant IS Code , |
| 150 | The transformer shall be provided with standard fittings/accessories as per relevant IS and mentioned below, protection alarm/trip protection, 3 nos. of Polymeric Zinc Oxide surge Arrestors on HV Side. Winding Temperature scanner (Digital) with alarm/Trip contacts with RTD Sensors per LV winding and space for mounting differential protection CT's in LV chamber with neutral brought out separately including supplying and laying of copper conductor multicore control cable from transformer to HT breaker/HT Panel for safety tripping, complete as confirming to IS-2026 Part-11, i/c supplying and grouting of suitable M.S. Channel with all accessories ,complete in all respects as required at site as per CPWD specifications. Design ambient condition : |
| 151 | The transformer shall be provided with standard fittings/accessories as per relevant IS and mentioned below, protection alarm/trip protection, 3 nos. of Polymeric Zinc Oxide surge Arrestors on HV Side. Winding Temperature scanner (Digital) with alarm/Trip contacts with RTD Sensors per LV winding and space for mounting differential protection CT's in LV chamber with neutral brought out separately including supplying and laying of copper conductor multicore control cable from transformer to HT breaker/HT Panel for safety tripping, complete as confirming to IS-2026 Part-11, i/c supplying and grouting of suitable M.S. Channel with all accessories ,complete in all respects as required at site as per CPWD specifications .Design ambient condition : Noise level Shall not exceed limits as per NEMATR-1 with all accessories running measured as per IEC551/NEMA Standard. |
| 152 | a) air temperature 50 0C, b) Relative Humidity 90 % Max, c) Seismic Zone as per location of site, d) Altitude as per location/site. The transformer should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. All testing shall as per relevant IS Code. Noise level Shall not exceed limits as per NEMA TR-1with all accessories running measured as per IEC 551/ NEMA Fitting and Accessories : |
| 153 | The following fittings shall be provided:- a) Two earthing terminals with the earthing symbol b) Rating and terminal marking plates; c) Thermometer pocket with cap; d) Lifting lugs for the complete transformer as well as for core and winding assembly; e) Bi-directional flat rollers (for transformers above 200 kVA); f) HV side neutral grounding strip (where one of the HV bushing terminal is connected to earth); g) Arcing horns or suitable rating lightning arrestors for HT side – 3 Nos. for transformers up to 200 kVA; h) Bird guard; i) Jacking pads (for transformer above 1 600 kVA); j) Name Rating & Diagram Plate. k) Monogram Plate.i) Additional neutral separately brought out on bushing for earthing. |
| 154 | Level 5 :- 400 KVA (losses at 50% loading < 1150watt, losses at 100% loading < 3330watt) |
| 155 | HT VCB PANEL (1 Incoming + 2 Outgoing 800 Amps) |
| 156 | HT VCB PANEL (1 Incoming + 2 Outgoing 800 Amps) (INDOOR TYPE IP42) VCB 11 KV 800 Amps.- 3 nos. |
| 157 | SITC of indoor type panels shall be constructed from CRCA/ Aluminum Zinc coated steel sheet of 2 mm thickness, floor mounted metal enclosed, 11 KV VCB panel with 3 no’s VCBs, totally enclosed and fully interlocked, horizontal draw out, horizontal isolation type breaker as per IS 13118, as amended up to date and additional Specifications, having capacities as mentioned below, single break, trip free mechanism, manually charged and manually closing breaker suitable for use on 11 KV, 3 phase, 50 Hz A.C. supply with short circuit fault level of 26.3kA for 3 sec , Panel shall be full internal arc tested i.e. in all three chambers at 26.3kA for 1 sec for safety purpose (AFLR). compete with self-contained, fully interlocked, rack in and rack out mechanism, air insulated copper bus bars of 1000 amps capacity, breaker featured with mechanical ON/ OFF indicator with hand trip coil and auxiliary switch of 4 NO+4NC and equipped with following switchgears and accessories. Make of Vacuum interrupter, circuit breaker & Panel shall be same. i/c connections suitable for 3 x 300 sq. mm XLPE 11 KV cable (Cable entry from bottom) end termination with heat shrinkable jointing material etc. as reqd. |
| 158 | Incomming (a) 800 Amp VCB-1 Nos. |
| 159 | b) 11 KV / 110 Volts PT Class 0.5 accuracy and 50 VA burden with 1 No. Voltmeter (0-15 KV), digital type selector switch for voltmeter and protection fuses / MCB for HT metering up to 12 KV on incomer. (0-50- 100A) comply with IS 3156. PT must not be on the top of the panel. It must be floor roiled placed rear side of panel or on the CB trolley -1 Set. |
| 160 | c) Digital type multi-function meter and Digital type Ammeter - 1 No. |
| 161 | d) Flush mounted type Microprocessor based numerical IDMT relay with O/L, E/L and S/C -1 No. |
| 162 | e) Dual core /single core; separate sets, dual ratio 3 Nos. CTs 200/100/1 A of 5 VA burden and accuracy class 0.5 for metering and class 5P10 for protection comply with IS 2705 - 1 Set |
| 163 | f) R, Y, B ON, OFF, Trip Indication with Control MCB - 1 Set |
| 164 | Outgoing (b) 800 Amp VCB- 2 Nos. |
| 165 | b) Digital type multi-function meter -2 Nos. |
| 166 | c) Flush mounted type Microprocessor based numerical IDMT relay with O/L, E/L and S/C- 2 Nos. |
| 167 | d) (3 Nos each) of dual core dual ratio 3 CTs 100/50/1 A of 5 VA burden and accuracy Class-0.5 for metering and class 5P10 for protection - 2 set. |
| 168 | e) Annunciator -6 Window- 2 Nos |
| 169 | f) Hooter - 2 Nos |
| 170 | g) Aux. Relay- 6 Nos |
| 171 | h) Trip super vision Relay - 2 Nos. |
| 172 | Power panel pack with 220 Volt AC input &24 Volt DC continuous output suitable for closing / tripping / indication of 3 Nos. HT panel boards with 2 Nos. 12 Volts each maintenance free batteries of 100 AH each, charging unit for emergency delivering for trip system compete with suitable capacity of Ammeter and voltmeter i/c connections with2.5 sq. mm FRLS insulated copper conductor cable etc. as required. |
| 173 | LT BusductSupplying, installation by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Rising Mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required (a) 1000 A, Isc= 50kA for 1 sec |
| 174 | Main LT PANEL (2 Incoming, 1 Bus Coupler and 2 OutgoingSITC of cubical type Panel as per below specifications appropriate size and depth min 1100mm for 415 Volt, 3 Phase, 4 wire, 50Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 1000 Amps capacity extensible type FP Aluminum Alloy bus bars of high conductivity with heat shrinkable colored sleeves and i/c DMC/SMC bus bar supports, with short circuit with stand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100mm x 50mm x 5mm thick, fabrication shall be done in transportable section, entire panel shall have a common copper earth bar of suitable size at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with 2.5 sq.mm PVC insulated copper conductor single core cable, cable alleys, cable gland plates in two half, i/c providing and fixing following switch gears. |
| 175 | (2 Incoming, 1 Bus Coupler and 2 Outgoing)SITC of 800 Amps 4 pole horizontal draw out type air circuit breaker 433V AC, 50Hz AC operation of fault breaking capacity 50 kA (Ics = Icu = Icw =100%) for 1 sec. electrically operated (EDO), fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators, zone selective interlocking, ready to close, over temperature protection, thermal memory and frame earthing contact, conforming to IEC 60947/IS-13947/Part-II/1993 latest version as amended up-to-date complete with following accessories for each. a) Independent electrical and manual spring closing mechanism – 1 set.b) Microprocessor releases-based adjustable setting for over current, earth fault & short circuit protection with 4-line LCD (R, Y, B, N) LCD display with bar graph for % loading of phases. all three current, neutral current, release should self-powered requiring no external power supply, protection against phase unbalance current, counting the number of operations and contact wear of arc chutes, over temperature protection with min.10 fault history and event history minimum 50 and inbuilt zone selective interlocking feature contacts, counting the number of operations and contact wear, confirming to IEC:60947/ IS:13947, Part-II/1993 (latest version) – 1 set.c) Undervoltage release for each ACB's – 1 set.d) Digital type Multifunction Meter. (IV, KW, KWH, KVA, PF, HZ), 96mm square flush pattern with one set of 3 nos. CT's of 1000/5A Class I accuracy and 15 VA burden - 1 set.e) Phase indication LED lamps and breaker ON, OFF, TRIP indicating light, test terminal block set, circuit wiring as per standard practice, auxiliary contacts for positive interlocking of the breaker as reqd. – 3 nos.f) Electrical Interlocking – 1 set.h) Aux. Contactor + Add on Block – 3 nos.i) 4P high protection 70kA, surge protectors with MPCB for incomer – 1 no.j) 2A SP Control MCB's for protection of control circuit- 7 no.k) A/M Selector Switch (1P, 2way With Off) – 1 no.l) 06A DP MCB 10kA – 3 nos.m) 25A Breaker Control Switch – 1 no. |
| 176 | Sub - LT PANEL – Outgoing- (Each VFD starter shall i/c Digital meter with CT’s, Controlling MCB, Fan, Push Button, A/M Selector Switch)SITC of VFD starter with programming accommodate all switch -gear items required to meet the technical requirements of ASD & Adequate rating, Over Load relay, Single phase preventer relay with under Voltage and over voltage or as suitable, Flush mounting type Ammeter, Voltmeter/ Digital Meter with Selector Switch suitable CT connection, Indicating lamp for ON, OFF, Trip, Indicating lamp for R,Y,B with the features precise speed, torque and position control functions that are suitable for both sensor and sensor-less types of synchronous and asynchronous motors. With higher overload capacity, the power range of reach up to 560 kW, providing the best performance and stability for a variety of heavy duty and constant torque applications, for advanced manufacturing is equipped with built-in PLC functions and supports various protocols for the ultimate in system flexibility and fast data exchange. |
| 177 | Overload capability▪ Heavy Duty 150% 60 / 180% 3 sec.▪ 460 V 0.75 kW ~ 560 kW Advanced Drive Controls▪ Environmental Adaptability1. 50˚C operating temperature2. Built-in DC reactor3. Coated circuit boards4. Built-in EMC filter5. International safety standard (CE / UL / cUL) |
| 178 | ▪ High Performance1. For both synchronous and asynchronous motors2. Dual rating design (heavy duty / super heavy duty)3. Speed / torque / position control mode4. High bandwidth control▪ Versatile Drive Controls1. Built-in safe stop function2. Built-in PLC function3. Built-in brake unit4. Supports various network protocols5. Position control |
| 179 | ▪ Modular Design1. Hot pluggable LCD keypad2. I/O extension cards3. Various PG (encoder) feedback cards4. Network cards for fieldbus modules5. Removable fanIntelligent PLC Functions▪ Built-in 10k steps capacity of PLC functions. Distributed control and independent operation are easily achieved via network connection▪ CAN open Master protocol and PLC functions provide synchronous control and fast data exchange |
| 180 | Quick and Easy Parameters Setting via the LCD Keypad▪ Multi-column display for the drive status▪ Simple and intuitive operation▪ User-defined parameter groups▪ Real-time clock (RTC) function▪ Multi-language display▪ Copy function saves parameters and PLC programs to the keypad memory for easy backup / transferring to other drive▪ IP66 protection level |
| 181 | Positioning Control Homing, Multi-point PositioningPositions the motor at a specific point (within a single rotation) for precise stop upon request Allows the motor to operate from one position to another, and switches up to 15 positions with 4 multi-function input terminals Determines the original position of the motion system, so as to ensure the motor starts from the same coordinates during each machining processA Drive for Permanent Magnet (PM) MotorsThe dual mode drive to control both an induction motor and permanent magnet motor. The dynamic response of a PM motor provides precise control of position, speed and torque |
| 182 | High-Performance Field-oriented ControlThe FOC+PG mode can output 150% of starting torque at extremely low speeds for precise and stable speed control. IM motor PM motor 0 Hz 0.1Hz 0.5Hz 1Hz 2Hz 3Hz 5Hz 10Hz C type 0 50 100 150 200 250 300 -1 1 3 5 7 9 11 Frequency(Hz) Torque(%) Example for 3.7kWFast Response to Impact LoadDuring load changes, the calculates the required torque response and minimizes the vibration caused by load impact using FOCAuto Energy-Saving OperationAuto-calculates the optimal voltage for the load output using load power when under constant speed operation100 150 200 250 300 350 400 450 500 -100 -80 -60 -40 -20 0 20 40 60 80 100 Time Speed (RPM) Frequency Command = Frequency Output, Output Voltage Output Current Current < Rated Current * 0.35 5sec |
| 183 | Deceleration Energy Backup (DEB)This function controls the motor deceleration to stop when power blinks off to prevent mechanical damage and then accelerates to its original operation speed when power resumes Time Motor Flying Start DEB Return Time DEB Decelerate to Stop Safe Motor Stop DEB Return Time DEB Decelerate to Stop Temporary power loss Sustained power loss Input Voltage Motor Speed Input VoltageModular DesignVarious accessories options, such as I/O extension cards, encoder feedback cards, communication cards, hot pluggable LCD keypad, removable terminals and removable fans |
| 184 | ▪ Removable terminalsConvenient wiring and safety equipment. Analog I/O switch Termination resistor Dual RJ45 communication ports The modular design fulfills the needs of system applications and equipment maintenance▪ KPC-CC01 keypad▪ Standard RJ45 network cable for remote operation.▪ Easy to remove with one press.▪ The product nameplate shows the input / output voltage, input / output current, the frequency range, and more.▪ Remove the safety screws and press on both side tabs to remove the cover.▪ RFI Jumper▪ Modular fan design, easy to replace and clean, extending product service life.► Built-in DC choke to surpress harmonics*► Built-in EMC filter to filter noise*► Conformal coating (Class 3C3 of IEC60721-3-3 standard) ensures drive operation stability and safety in critical environments. |
| 185 | ► The electronic components of the drive are isolated from the cooling system to reduce heat interference. Dissipated heat can be discharged by flange-mounting installation, and forced fan cooling can import cold air into the heat sink. The heat dissipation performance is optimized by these two cooling methods. Certifications - UL, cUL CEDust-proof, Interference, Heat immunity, dissipationLow Voltage: EN61800-5-1EMC: EN61000-3-12, EN61800-3, IEC61000-6-2, IEC61000-6-4, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8Provides various fieldbus cards for flexible applicationsThrough the designed Device Net Builder software, users can easily establish a standard Device Net control Zetwork by the parameter pre-assignment function for each equipment and remote I/O• Supports all industrial automation products (Built-in EDS files for all industrial automation products)• I/O data configurations for each device on the Device Net network |
| 186 | • Device-Net layout software communication integrator software that offers graphic module settings and a user friendly interface to support all Ethernet products settings and online monitoring• The software for Ethernet/Modbus TCP products• Graphic module settings and a user friendly interface• Auto search function• Supports VirtualCOM settings |
| 187 | Convenient Drive System Management Platform▪ Provides a complete operation platform for users' easy control and monitoring via PC, including parameters save/ setting, real-time wave monitor, quick setup, for multiple languages and with multi-language operation systems Start-up display Displays horsepower, rated voltage and current of the drive in use Parameter management Provides parameter setting / save / copy / comparison for convenient parameter management Trend records Monitors the drive operation form via network and displays I/O terminal status. Useful for tasks such as \\"trial run monitoring\\" Quick setup - Guides the user step-by-step through the drive settings according to quick setup wizard |
| 188 | SITC of 100 HP VFD starter with programming |
| 189 | SITC of 75 HP VFD starter with programming |
| 190 | SITC of 25 HP VFD starter with programming |
| 191 | SITC of 10 HP VFD starter with programming |
| 192 | Providing and fixing 250 A 4P MCCB, 36kA with Microprocessor based O/C and S/C release with inbuilt display for current metering with class 1 accuracy operational voltage shall be 690Vac and ajustable setting time delay and Rom, + 1 C/O Aux. Contact & Trip Contact (ICS=ICU=100%).ROTARY HANDLE FOR 250A MCCBPHASE SPREADERS FOR 250A MCCB TPSpreader Link and Direct ROM |
| 193 | Providing and fixing 125 A 4P MCCB, 36kA with Microprocessor based O/C and S/C release with inbuilt display for current metering with class 1 accuracy operational voltage shall be 690Vac and ajustable setting time delay and Rom, + 1 C/O Aux. Contact & Trip Contact (ICS=ICU=100%).ROTARY HANDLE FOR 125A MCCBPHASE SPREADERS FOR 125A MCCB TPSpreader Link and Direct ROM |
| 194 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 195 | SITC of ultrasonic sensor in each water storage tank with measuring range upto 5 meters measurement accuracy of 0.5% - 1.0%, Resolution ratio of 3mm or 0.1% (whichever is greater) with LCD digital Display, Analog output of - 4-line system with 4-20mA current, 510 Ù load, 2-line system, 4- 20mA, 250 Ù load with Relay output - 2 group (i.e. AC 250V/8A or DC 30V/5A) with 24VDC supply, Ambient temperature Display instrument - 20~+60°C with IP66 protection etc complete as reqd. |
| 196 | SITC of Micro Processor Unit having a high-performance 32-bit ARM Cortex-based processor operating up to 72–180 MHz with embedded Flash memory, SRAM, multi-channel 12/16-bit ADC, advanced timers, PWM generation, RTC with battery backup support, watchdog protection, and multiple communication interfaces including UART, SPI, I2C, CAN. The system integrates WiFi SoC supporting IEEE 802.11 b/g/n at 2.4 GHz with built-in TCP/IP stack, WPA/WPA2 encryption, SSL/TLS security, OTA firmware upgrade capability, and dual operating modes (Station/AP). The unit operates on a wide 9–24V DC input supply with reverse polarity, over-voltage, surge, and short-circuit protection, along with high-efficiency DC-DC regulation for stable 5V and 3.3V rails. Communication is provided through industrial-grade RS485 (Modbus RTU compatible) with configurable baud rate and multi-drop capability. The controller includes heavy-duty electrically isolated relay outputs (NO/NC type) suitable for pump contactor control, along with LED status indication. The unit is designed for DIN rail/panel mounting and continuous industrial operation. The embedded firmware provides intelligent pump automation with user-configurable tank level start and stop settings, adjustable hysteresis control, and support for float or sensor-based inputs. |
| 197 | The system incorporates automatic pump rotation logic to ensure equal runtime distribution and seamless alternation after each stop cycle. User-configurable priming interval and priming time settings allow efficient air removal and smooth pump startup. Advanced under-current monitoring enables dry-run detection with adjustable threshold settings and automatic pump trip protection. The controller also includes user-defined maximum pump run time protection to prevent overheating or mechanical damage. Additional features include real-time clock-based event logging, non-volatile parameter storage, password-protected configuration, alarm and fault history logging, watchdog-based self-diagnostics, SCADA compatibility via Modbus RTU/TCP, and remote monitoring capability through WiFi connectivity. |
| 198 | SITC of Scada software for online Monitoring pump house of site with following specification: -Overview: The SCADA software shall provide comprehensive real-time monitoring, control, and data management for the water distribution system. It will enable users to remotely view and manage the system from anywhere using web browser and application.Key Features:Real-Time Data Monitoring: Displays real-time status and parameters of all system components, including pumps, sensors, flow meters and valves.User Interface (UI): A user-friendly, customizable live UI that shows the current status of all systemcomponents.The UI shall provide basic functions for supervision and control of the system.The UI shall give the user access to alarms and events displayed on the screen. Aside from these lists onthe screen, there shall be a printout of alarms or events in an event log. |
| 199 | The following standard pictures shall be available from the UI.➢ Graphical diagram showing the Hardware status.➢ Pop us box to display pump details like voltage, ampere, Power Factor, Power consumption etc.➢ Event list, station➢ System status. . Remote Command Execution: Enables users to issue remote commands for controlling pumps, sensors and valves. In order to ensure a high degree of security against undesired operation, a “select-before-execute” command procedure shall be provided. After the “selection” of a hardware, the operator shall be able to recognize the selected device on the screen and all other hardware shall be blocked. As communication between control centre and device to be controlled is established, the operator shall be prompted to confirm the control action and only then final execute command shall be accepted. After command execution the user shall receive a confirmation that the command is executed. In theselected object picture, all attributes like➢ Authority➢ Local / remote control➢ Errors etc. shall be displayed. |
| 200 | Event Data Management: Allows users to download and analyses historical event data logs.The Report page shall contain all the commands that are executed for the control and monitoring of the water distribution system. The event and associated time of its occurrence has to be displayed for each event. The event page shall be automatically updating at real time within maximum of 10sec duration. The operator shall be able to call up the event list on the monitor at any time for the whole water distribution system or sections of it. The events shall be registered in a chronological event list in which the type of event and its time of occurrence are specified. It shall be possible to store all events in the computer for at least one year. The Report page shall be download in pdf and excel format. The Report can be viewed/download in web browser by selection of date and time in From and to format between 1-year period.The chronological event list shall contain:➢ All Hardware of system like - pumps, sensor, valve.➢ All Pumps parameter like Voltage, Current, Power Factor, Power consumption etc installed in the system. |
| 201 | ➢ All sensor values installed in the system.➢. All Valve status installed in the system.➢ Loss of communication.➢ Filters for selection of a certain type or group of events shall be available. The filters shall be designedto enable viewing of events grouped per:➢ Date and time.➢ Hardware➢ Status |
| 202 | Providing & Fixing of Wi-Fi router for monitoring of pumps with the following specifications:- External Power Supply: 9VDC/0.6AInterface:-4 10/100Mbps LAN Ports: 1 10/100 Mbps WAN PortsDimension: 7.6 x 5.3 x 1.3 in. (193 x 134 x 33mm)Antenna: 2.5dBi Fixed Omni Directional AntennaWireless Function: Enable/Disable Wireless Radio, WDS Bridge, WMMWireless security: 64/128/ 152-bit WEP/ WPA/ WPA2, WPA-PSK/WPA2-PSKFrequency: 2.4-2.4835GHz |
| 203 | S/I/T/C of Fully Automatic Battery Charger, with Trickle/Boost selection Facility, with DC Ammeter and DC Voltmeter, 240Vac Input, 24Vdc/12A Output, AMF Relay, Push button, A/M Selector Switch, Aux. Contactor 2NO+2NC 230V AC FOR AMF CIRCUIT, Indicating Lamps, LED Type, Red -3, Green-2, Amber, Push button, 6A Control MCB 10KA C-Curve etc. including connection etc. as required. |
| 204 | On load change over switch 630 Amp, 3 Nos. (2 DG set and 1 for phase sequence), |
| 205 | Supply of XLPE insulated PVC sheathed Aluminium conductor armoured cable 11 KV conforming to IS: 7098/ (Part- II) (UE) of size 3 core 240 sq mm |
| 206 | Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. (a) 240 Sqmm |
| 207 | Supply, laying and termination of XPLE/PVC insulated & PVC sheathed (Heavy Duty) armoured Copper conductor power cable for working voltage 1.1 KV conforming IS 7098/ (Part- I) 1988 as required. ( FOR starter to motor 75 hp) (a) 3 core 95 sqmm |
| 208 | Supply of XLPE insulated PVC sheathed Al. Cond. Unarmoured cable of 1.1kV grade conforming to IS-7098 Part-I of following size, (a) 1 x 630 sqmm Single core cable |
| 209 | INTERNAL ELECTRIFICATIONWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. (a) Group C |
| 210 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 211 | (b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 212 | (c) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 213 | (d) 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 214 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 215 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 216 | Supplying and fixing suitable size GI box with modular plate & cover in front on surface or in recess, including provideding & fixing 3 pin 5/6 amps modular socket out let & 5/6 amps switch, connection etc as required (for light to be used in non residential building) |
| 217 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 8 way Double door |
| 218 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 6 way (4 + 18), Double door |
| 219 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single Pole |
| 220 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 63 amps |
| 221 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 63 amps |
| 222 | Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 223 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. (a) 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 224 | LED Batten light (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) (a) 18- 22 Watt |
| 225 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Upto 450 mm sweep |
| 226 | Providing of 600 mm sweep pedestal fan, air delivery 250 cubic meter per mnt, height approx 24 inch, min 3 blades complete with base plate, supporting rod, jaal workable on 220/240 volts AC single phase supply etc as reqd. |
| 227 | Supply of 15\\" (380mm) sweep 1400 rpm exhaust fan heavy duty complete with shutter, blade etc. as reqd. |
| 228 | Supply of 9/10 watt LED lamp sutable for B-22 holder. |
| 229 | SITC of wall mounted fan 400 mm sweep rated voltage 220-230 AC rated frequincy 50 Hz Speed 1280-1350 rpm with disared colour. |
| 230 | Supplying Installation Testing and Commissioning of 4 MP IP IR Dome Camera having followingspecifications and features etc :- 1) Signal System: PAL/NTSC, Signal to Noise Ratio: > 50 dB,Camera should display Camera title, Date &Time in live & recorded video 2) Image Sensor: 1/2.8\\" or better progressive Scan CMOS to get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking. 3) Compression (Minimum): Video:- H.265 or better,Audio:- G.711U/A, G.711Mu, G.726, AAC, G.7234) Wide Dynamic Range:- WDR (120dB or more)5) Digital Noise Reduction:- DNR (3D) On/Off6) Video Streaming & Frame Rates :- Triple streaming , configurable Main stream: 4MP (2560×1440)25/30fps , Sub streams minimum: 720P@25/30 fps7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion, Motion Detection |
| 231 | 8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade9) Onboard Storage: Camera should support built-in Micro SD/ SDHC/ SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card.10) Recording Management: Format SD, overwrite, storage management, video to NAS device,11) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection12) Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PP PoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast,13) System Capability: ONVIF, Camera shall support open source VMS14) Ethernet: 1 RJ 45 10/100 Ethernet port15) Audio: - It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement.16) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power source.17) Power Requirement: 12VDC/24 VDC/PoE (802.3af)/ePoE18) Housing/ Enclosure: - IP67 weather proof, IK10, Metallic body19) Operating Condition: - Ambient Temperature:- (-)05°C to 50°C, humidity 95% (max) (non-condensing)20) IR life: 40000 hours or higher21) Video Bit rate: 32 KBPS - 8 MBPS or better22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS |
| 232 | (a) 4MP @ 25/30fps@1440P (2560 x 1440) Dome Camera with 2.8/ 3.6/ 6/8/12 mm fixed lens (as per site requirement). |
| 233 | 8 MP IP IR Outdoor Bullet CameraSupplying Installation Testing and Commissioning of 8 MP IP IR Outdoor Bullet Camera having following specifications and features etc: -1) Type of Camera: Outdoor Bullet Camera2) Image Sensor: 1/2.8\\" or better progressive Scan CMOS get color image even at night condition3) Signal System: PAL/NTSC 4) Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better5) Imaging: 1/3s to 1/30000s, Auto Gain Control, White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded video both.7) Signal to Noise Ratio: > 50 dB8) Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto switch, IR Source- Inbuilt Smart IR LED's with effective distance upto 50 Mtrs integrated IR and 30 meter for colour view in night9) Video Compression (Minimum): H.265 or better H.264, Audio:- G.711U/A, G.711Mu, G.726, AAC,G.72310) Wide Dynamic Range: WDR (120dB or more)11) Digital Noise Reduction: DNR (2D/3D) On/Off12) Streaming: Triple streaming, configurable13) Video Streaming & Frame Rates: Triple streaming, configurable Main stream: 8MP (3840 × 2160)@20 fps, Sub streams: 4MP @25/30 fps & D1@25/30 fps; |
| 234 | 14) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser15) Profile Management: User configuration import, export16) Security: User Authentication, Digital Water Marking17) Onboard Storage; Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card.18) Recording Management: Format SD, overwrite, storage management, video to NAS device,19) Edge Analytics: Tripwire, Intrusion, Motion Detection20) Alarm Trigger: Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 21) Alarm Support: It should have 1/1 Alarm In/ Out Port22) Audio Support: It should have 1x Built-In Mic and 1/1 Audio In/ Out Port for external Mic. and Speaker (As per site requirement) with G.711U/A/ G.711Mu/AAC/ G.726 audio compression23) Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast,24) User Access: Minimum 08 Users25) System Capability: ONVIF Profile S, G & T. CCTV Camera OEM should be fulltime member of ONVIF and quoted models should be listed on ONVIF official website (All the certifications & Credentials should be valid on the date of technical evaluation).26) VMS: Camera shall support open source VMS |
| 235 | 27) Cyber Security: trusted boot, AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade. 28) Ethernet: 1 RJ 45 10/100 Ethernet port29) Power Input: The camera should supportsimultaneous dual power input—12 VDC (via power adapter) and PoE—to ensure continuous operation in the event of a failure in one power source.30) Power Requirement: 12VDC/24VDC/PoE (802.3af)/ePoE31) Enclosure: IP67 weather proof, IK1032) Operating Condition: Ambient Temperature:- (-)05°C to 50°C, humidity 95% (max) (non-condensing)33) IR life: 40000 hours or higher34) Video Bit rate: 32 KBPS - 8 MBPS or better35) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS (a) 8 MP (3840 × 2160) or better IP IR 2.8/ 3.6/6/8/12 mm fixed lens |
| 236 | Network Video Recorder (NVR)40.10 Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc as mentioned below :1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses for number of channels of NVR to record per NVR and to provide a live view, storage and simultaneously Multi-channel playback of all IP, IR camera or more and must be ONVIF with minimum support of 256Mbps incoming Bandwidth. 2) NVR should support H.265 or better, H.264, MJPEG, MPEG4 support3) Must support 1 channel Input, 1 channel Output, RCA for Two-way Talk4) Intelligent auto power on when power resumes after power outage.5) Storage: It should support minimum 2 SATA Slots with 20TB capacity/ Slot.6) Connectivity Interface : 1 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x RS2327) Backup Interface : Its should have 2 Nosx USB port (1x USB3.0, 1xUSB2.0)8) Video Output Ports: 1x HDMI and 1 VGA9) Alarm Ports: It should have 4/1 Ch In/ Out ports to connect various type of external sensors and output devices like hooter/ Siren etc.10) Email & SMS Altert options: Option for SMS/ Email Alerts to minimum 5 designated mobile number for power failure, HDD failure, vandalism, tempring, network disconnection and panic |
| 237 | 11) Web & Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone) for alerts and viewing.12) Protocols: HTTP, HTTPS, TCP/IP, IPv4, UDP, NTP, DHCP, DNS, SMTP, UPnP, DDNS, Alarm Server, IP Search, Multicast, Auto Registration, ONVIF (Profile T, Profile S, Profile G), CGI, SDK and OEM Cloud for remote monitoring without any public IP need. 13) Standards: CE, FCC, RoHS and BIS Certified14) Power Supply : Should support 12VDC, 4Amp or AC100-240V, 50/60Hz Power supply.15) Operating Condition : Ambient Temperature (-5°C to 50°C), humidity 90% (max) (non-condensing)16) The VMS, NVR application shall support all the features & functionalities of the offered cameras.17) VMS should consist of Base license and Channel Licenses. VMS should be provided with camera Licenses , with no dependency of VMS licenses by binding with the MAC address of the cameras to achieve the functionality.18) The NVR OEM shall be responsible for providing a mobile application compatible with both Android and iOS devices, enabling remote monitoring and playback of cameras/NVR footage. |
| 238 | 19) The OEM must provide its own DDNS server hosted in India, eliminating the need for a public IP address for remote monitoring over the Internet.20) Must support Resolution: 7680x4320 (8K), 3840*2160, 1920×1080, 1280×1024,1280×720, 1024×76821) Must support recording resolution upto 32MP22) Must support Continuous, Alarm, Motion, Instant, Panic Recording Mode23) When alarm recording is enabled and an event occurs, you can click the alarm icon on monitoring page to view the alert details. The snapshot function is supported on monitoring and playback page24) The Network Video Recorder (NVR) shall be configured to send email whenever a system message is created or an alarm event occurs. The email server shall be a valid SMTP server. Each recipient email address shall be configured to receive any combination of critical, warning, or informational messages or alarm notifications. When an alarm occurs, the email message includes the NVR name, time of alarm and a list of camera that is configured to record upon alarm 25) It should support Network Support: HTTP, TCP/IP, SMTP, DHCP, DNS, DDNS, FTP, NTP, UPnP, Multi IP Setting. Convert multiple recording files to one avi/MP4 file.26) General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection. |
| 239 | 27) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan28) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email. 29) Built-In Artificial Intelligence: NVR should have uilt-in AI :- - 2 Channel face detection and recognition, - Minimum 4 Channel perimeter protection, - Minimum 8 Channel Smart Motion Detection30) Face Recognition Database Capacity: It should support total Blacklist and Whitelist capacity of Minimum 20,000 Faces or more with Face Detection speed of 12 face images/sec.31) Face & Human Attributes Search: Search Pictures/ Video by Gender, age group, glasses, expressions, face mask, beard, Top color, top type, hat, bag, age, gender and umbrella.32) ANPR Capability: It should support ANPR Camera with License plate, plate color, vehicle body, vehicle model, vehicle logo, calling, seatbelt, vehicle registration location etc vehicle attributes. |
| 240 | 33) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan, cybersecurity exception34) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email.35) General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection.36) Smart playback function: Should support smart search for the selected area in the video and smart playback to improve the playback efficiency37) VCA (Video Content Analytic): Should support multiple video contented analytics based on camera analytics . (a) 16 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16, 2nd screen: 1/4/8/9/16 |
| 241 | Hard Disk DriveSupplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications. (a) 8TB (Terabytes) |
| 242 | Supplying, Installation, Testing and Commissioning of following size LED display Smart TV (LED monitor) industrial grade with 3840x2160 resolution or better, USB playback, bluetooth and miracast connectivity, 4X HDMI 2.0, DP 1.2, HDR 10/10+, brightness: 500-nits or better, Video wall mode should be available, contrast ratio: 1200:1, OPS slot, viewing angle (H/V): 170°/ 170°, response time less than 12ms, Display control shall be on monitor screen and programmable with remote (remote shall be supplied with system), Key Board, Optical Mouse, etc. as required. (a) 55 inch or larger |
| 243 | SITC of IP65 box (without PoE switches) of dimention 310mmX160mmX140 mm on pole or wall with suitable arrangement for support/installation of 8 port Giga PoE switch and 1 nos. 15/16 amp modular switch socket set |
| 244 | Supplying, Installation, Testing and commissioning of following CAT6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. (a) Copper Patch Cords of length 1m (3ft) |
| 245 | Supplying and fixing Patch Cord of Optical Fiber Multi Mode or Single Mode LC to LC Fiber Duplex having high precision ceramic ferrule with good concentricity, Fiber corning single mode G652D, Cable Type 2mm with Mechanical specification Apex Offset < 50 μm, Fiber Height + 100 nm, End-face radius of Curvature 7mm < R <25mm, Repeatability < 0.2 db, Working ambient Temperature – 5 0C to +50 0C, Storage Temperature – 10 0C to +50 0C, Length -- 2meter, Type -- LC-LC Duplex etc complete as required. |
| 246 | Supplying and drawing following core Multi mode Fiber Optic Cable having corrugated steel armoring, leser optimize 50/125 μm with HDPE jacket, LSZH (Low smoke Zero Halogen), Tight-buffered or loose tube, maximum attenuation: < 3.5 dB/km at 850 nm, < 1.5 dB/km at 1300 nm, bandwidth > 2000 MHz-km at 850 nm, > 500 MHz-km at 1300 nm compliance and certifications: ISO/IEC 11801 Ed. 2.2, ANSI/TIA-568- C.3, ITU-T G.651.1 RoHS compliant. Multi Mode Fiber shall be Central-loose tube filled with Thixotropic jelly, uly following Standards: ISO 11801, IEC 60793- 1/60794-1-2, ITU-T-REC G.652D and Telecordia GR- 20-core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature should be – 5 0C to +50 0C and Storage Temperature should be – 5 0C to +50 0C, Maximum Attenuation ± 3.5 dB/km at Operational Wavelength 850 nm and ± 1.5 dB / km at Operational Wavelength 1300 nm . type of fiber should be 50/125 / G.652D & Refractive Index should be 1.483/1.478, The value for Mode-filed,Cladding Diameter 50 ± 2.5 μm and 125 ± 1μm correspondingly i/c splicing & marking etc complete as required. (a) 12 Core Multi Mode Optical Fiber Cable |
| 247 | Supplying and fixing of following size Wall Mount ack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. (a) 9 U Rack |
| 248 | Supply and fixing following port Rack Mount loaded LIU with pigtail, Front-mounted cable saddles for jumper management, suitable to manage both splices and terminations, Pre-assembled shelves in multiple configurations, Rubber fiber slotted bracket built-in, metal splice shelf to protect the fibers, 2 fiber spools built-in for 900μm tight buffered fiber storing, Capable of storing up to 3 meters of 900μm tight buffered fiber per adapter, Removable front and rear covers for better access to interior of LIU, Should be Single /Multi mode LC Type fully loaded. Accessory kit consists of cable ties, mounting ear screws, and spiral wrap tube etc complete as required. (a) 12 Port LIU |
| 249 | Supplying and laying of armoured of CAT 6 Cable in the existing surface/ pole etc. with allied accessories, connections complete as required. |
| 250 | Online UPS - Input supply: Single Phase, Output Supply: Single Phase.Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion(ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply |
| 251 | AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 0C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Display for watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPS should be with IGBT Based Inverter Technology, Communication RS232/ RS485/ SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accessories are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc (a) 2KVA |
| 252 | Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, Non- Plenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc. complete as required. (a) 2 Run of cable |
| 253 | Supplying, Installation, Testing and commissioning of CAT6 Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability etc. complete as required. |
| 254 | Supplying, Installation, Testing and commissioning of RJ45 Connector for CAT 6/6A Cables. RJ45 modular plug supports 4 twisted pairs, 8 positions, 8 connectors. Housing: PC, UL94V-2, transparent color, Use for 24- 26 AWG stranded wires etc. complete as required. |
| 255 | Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel. 24 Ports Cat-6 Patch Panel should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. |
| 256 | Supplying, installation, Testing and commissioning of following capacity 8 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: Minimum 8 X RJ-45 Gigabit Ethernet Ports and additional 2 X 1G SFP Ports with non-blocking architecture by having Switching capacity of minimum 20Gbps and packet forwarding rate of 14Mpps or higher, 8K MAC table. Internal dual AC Power supply with operating temperature of -5 0C to +50 0C. Jumbo frame: 10KB or higher, IGMP Snooping, IGMP snooping querier and support for IGMP Snooping Fast Leave, Should create 250 or more MLD groups, MLD Snooping, Per VLAN MLD Snooping C MLD Snooping Fast Leave, STP, RSTP, MSTP, Loopback detection, Multicast filtering, VLAN Tagging, ǪOS: 8 Ǫue per port, WRR, IPv4/IPv6 Interface : minimum 100 IPv4 static route entries and minimum 50 IPv6 static route entries, 700 Acess Control entries, SSH CSSL for IPv4 and IPv6, 802.1x, ARP Spoofing, DHCP Snooping and server screening, IP+MAC+Port Binding, Per Port Bandwidth Control, 802.1X Authentication (Supports local/RADIUS database, Port-based Access Control and EAP, OTP, TLS, TTLS, PEAP Support) Cable Diagnostic feature, LLDP, LLDP-MED, SNTP/NTP, RMON, SNMP v1,v2c, v3 and SNMP Traps. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required. (a) 8 port PoE Layer 2 Network Switch with PoE Support of 130W or higher with each copper port supporting 802.3at PoE+. |
| 257 | Hiring of 82 BHP Diesel engine dewatring pump set (8\\"X8\\") with operation and maintenance i/c suction and delivery line with all accessories and as per site requirement and round the clock operator as reqd. (Diesel will be provided by the department) a. Hourse power : 82 BHP, b. Engine Type : Diesel Engine, c. Discharge Capacity : 100.00m3/hr. d. Size : 8\\" X 8\\", e. Derating factor : 3 % per every 1000 ft. above 300 ft. / 1% for every 10 deg F above 77 deg F, f. Diesel engine should be CPCB IV+ complaint. |
| 258 | Providing & installation of Butterfly Valve/ ball valve with electrical actuated (upto 80mm) a self-contained control package with local controls, status indication relays, isolated control circuits with 24 VDC, 220 VAC, 1Ø, 50Hz, position indication via local manual indicator, temperature rating from - 5 ْْC to +50 operation and etc. as required with following facility. AIL SLIMSEAL is a Wafer type Butterfly Valve with an integrally moulded elastomer body liner with working pressure rating upto 10NM. Specification for Butterfly valves/ ball valves, Wafer Short API 609 - Lug and Wafer type Butterfly Valves, Category A MSS SP 67 - Butterfly valves, Narrow body ISO 5752 - used in flanged pipe systems, Face to face and Centre to face dimensions. BS 6755 Part 1 Pressure testing Black Nitrile/EPDM seat Test Pressure is at Body / Disc 24 & Seat 17.6. Potentiometer unit is synchronous with output transmission shaft to provide a feedback signal. Local control unit is control with local/Remote selection switches. Position Indicator can be either 0-100% or 4-20mA. Programmable Logic control. Electrically & Mechanically Interlock Run the actuator for a per defined travel in ON-OFF step. |
| 259 | Engaging of Skilled Staff for Operation of storm water pumping station under civil line zone. i/c Operation & maintenance of Pump sets, ATS panel, Starters and other electrical inatallation etc and including preventive maintenance for various Mpl. Pumps/Building/ Assets Complete in all respect, for the period of 365 Days (a) Skilled (Wireman/APD/Driver): - (1 Pumping Station x 3 Shift x 365 days = 1095 shift) |
| 260 | Providing of following Highly Skilled staff for Operation and maintenance of Electrical Installation (HT & LT work all types) High Tension line, Transformer, DG set and other electrical inatallation, HT Panel, LT Panel 220 & 440 volts, fans, tube light, pumps, light, light poles etc. and including preventive maintenance and providing breakdown services for various Mpl. Building/ Assets complete in all respect, for the period of 365 Days. (a) Highly Skilled (Electrician): - (1 Pumping Station x 1 Shift x 365 days = 365 shift) |
| 261 | Providing of following Un-Skilled Staff for watch & ward/cleaning of storm water Pumping station under civil line zone. i/c Operation & maintenance of Pump sets, ATS panel, Starters and other electrical inatallation etc Complete in all respect, for the period of 365 Days (a) Un-Skilled (Helper/Beldar/Nala Beldar/sweeper/ safai worker/ cleaner/ khallasi)): - (1 Pumping Station x 3 Shift x 365 days = 1095 shift) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail