Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | PHED (R) BSR 2023 - 1.1 - Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended up to date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. |
| 2 | PHED (R) BSR 2023 - 1.1.2 - 100 mm |
| 3 | PHED (R) BSR 2023 - 1.1.4 - 200 mm |
| 4 | PHED (R) BSR 2023 - 1.1.5 - 250 mm |
| 5 | PHED (R) BSR 2023 - 1.1.6 - 300 mm |
| 6 | PHED (R) BSR 2023 - 1.15 - Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge. |
| 7 | PHED (R) BSR 2023 - 1.15.1 - MS pipe specials up to 600mm dia (with minimum 5mm thickness sheet) |
| 8 | PHED (R) BSR 2023 - 2.21 - Plate Earthling as per IS:3043 with copper Earth plate of size 600mm x 600 mm x 3.0mm by embodying 3 to 4 mtr. Below the ground level with 25 mm dia. G.I. ‘B’ class watering Pipe including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
| 9 | PHED (R) BSR 2023 - 3.4 - Construction of RCC (Dome type) Clear Water Reservoir of following capacity as per Scope of work and Technical specification, consisting of the following main activities: - |
| 10 | PHED (R) BSR 2023 - - a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. .b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase.c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill.d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall. e) Successful hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the roof Slab.g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure. |
| 11 | PHED (R) BSR 2023 - - h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type).i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide.k) Providing and fixing of 150mm wide water bar for the construction joints in the container.l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir.m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. |
| 12 | PHED (R) BSR 2023 - 3.4.3 - Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2 & 3. |
| 13 | PHED (R) BSR 2023 - 3.4.3.1 - 500 KL capacity |
| 14 | PHED (R) BSR 2023 - 3.7 - Providing and fixing double flanged ISI marked DI Class K-9 pipes as per IS:8329-2000 (amended up to date), as vertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. |
| 15 | PHED (R) BSR 2023 - 3.7.1 - 100 mm |
| 16 | PHED (R) BSR 2023 - 3.7.5 - 300 mm |
| 17 | PHED (R) BSR 2023 - 3.7.6 - 350 mm |
| 18 | PHED (R) BSR 2023 - 3.7.7 - 400 mm |
| 19 | PHED (R) BSR 2023 - 4.1 - Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.: |
| 20 | PHED (R) BSR 2023 - 4.1 - All kinds of soil |
| 21 | PHED (R) BSR 2023 - 4.3 - Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and stacking serviceable material for measurements and disposal of unserviceable material as directed, with in a lead of 50 Mtr. including all safety provisions required .: |
| 22 | PHED (R) BSR 2023 - 4.3.1 - In ordinary rock |
| 23 | PHED (R) BSR 2023 - 4.5 - Dismantling of cement concrete pavement for pipe line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. |
| 24 | PHED (R) BSR 2023 - 4.7 - Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work. |
| 25 | PHED (R) BSR 2023 - 4.8 - Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work. |
| 26 | PHED (R) BSR 2023 - 4.8.2 - Plain cement concrete pavement of M-30 Grade |
| 27 | PHED (R) BSR 2023 - 4.10.2 - Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc. |
| 28 | PHED (R) BSR 2023 - 4.13 - Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) |
| 29 | PHED (R) BSR 2023 - 4.13.3 - Thermo-mechanically Treated bars (Conforming of relevent IS code) |
| 30 | PHED (R) BSR 2023 - 5.1 - Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at synchronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected on C.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. |
| 31 | PHED (R) BSR 2023 - 5.1.1.5 - 9.3 KW (12.5 HP) |
| 32 | PHED (R) BSR 2023 - 5.6 - Providing, installation, testing and commissioning of submersible dewatering pump set conforming to relevant IS codes and as per scope of work and Technical Specifications, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft, impeller, pump and motor body. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard. The pump set shall be suitable for direct coupling, with suitable suction strainer etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. |
| 33 | PHED (R) BSR 2023 - 5.6.2 - 1.5 KW (2.0 HP) |
| 34 | PHED (R) BSR 2023 - 5.7 - Providing and fixing at site with necessary packing, Horizontal Centrifugal Split Casting pumps with 4 pole induction motor operating at synchronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions.Note: Duty condition of required pump shall also be mentioned in BoQ. |
| 35 | PHED (R) BSR 2023 - 5.7.2 - Discharge 20 to 30 LPS and head 31 to 40 M |
| 36 | PHED (R) BSR 2023 - 5.7.11 - Discharge 31 t0 40 LPS and head 51 to 60 M |
| 37 | PHED (R) BSR 2023 - 6.8 - Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS AISI 316/410 Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 38 | PHED (R) BSR 2023 - 6.8.1 - Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 |
| 39 | PHED (R) BSR 2023 - 6.8.1.1 - 80 mm dia |
| 40 | PHED (R) BSR 2023 - 6.8.1.2 - 100 mm dia |
| 41 | PHED (R) BSR 2023 - 6.8.1.4 - 150 mm dia |
| 42 | PHED (R) BSR 2023 - 6.8.1.5 - 200 mm dia |
| 43 | PHED (R) BSR 2023 - 6.8.1.6 - 250 mm dia |
| 44 | PHED (R) BSR 2023 - 6.8.1.7 - 300 mm dia |
| 45 | PHED (R) BSR 2023 - 6.8.1.9 - 400 mm dia |
| 46 | PHED (R) BSR 2023 - 6.12 - Providing, lowering, aligning, fixing in position in pipe line, DI double flanged resilient seated Dual plate check valve of approved make of following Pressure rating & dia complete, as per API: 594/ API: 598 and of following specifications: Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Disc / plates - SG-400/12 or CF-8M,Face to face dimensions as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body and cover inside and outside . Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 410 , Hinge SS AISI 316/304,Spring SS AISI 316/304,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR \\"O \\"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) , Insertion rubber of black EPDM 6mm thick .Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 47 | PHED (R) BSR 2023 - 6.12.1 - Class PN 1.6 |
| 48 | PHED (R) BSR 2023 - 6.12.1.1 - 80 mm dia |
| 49 | PHED (R) BSR 2023 - 6.12.1.4 - 150 mm dia |
| 50 | PHED (R) BSR 2023 - 6.12.1.5 - 200 mm dia |
| 51 | PHED (R) BSR 2023 - 6.13 - Providing, lowering, aligning, fixing in position and Jointing in pipe line, DI Body Flanged End Tamper proof Kinetic Air Valve class PN 1.6 of approved makes of following pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(amended up to date) Body, High pressure cover , Low pressure cover, Cowl and Joint support ring - Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, Float- LP ball & HP ball : AISI 304 stainless Steel, Seat ring & Gasket - EPDM/NBR ,HP Orifice & HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (NonToxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & cover inside and outside fasteners - CS/ Galvenised steel, Outlet of big orifice will have a screen to prevent Tamper of float, with DI metal seated D/F Non rising stem Sluice Valves as per (IS: 14846 amended upto date) PN 1.6 ratings Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work. |
| 52 | PHED (R) BSR 2023 - 6.13.1 - Class PN 1.6 |
| 53 | PHED (R) BSR 2023 - 6.13.1.1 - 40 mm dia |
| 54 | PHED (R) BSR 2023 - 6.13.1.2 - 50 mm dia |
| 55 | PHED (R) BSR 2023 - 6.15 - Providing, lowering, aligning & fixing in position DI D/F Plunger Type Flow Control Valve of approved make of following Pressure rating & dia complete and of following specifications: Body- Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or EN-JS 1030, Plunger/ Piston - Stainless steel AISI- 304/ Gr 1.4301, Piston Guides- Bronze Welded Overlay / SS Shaft/Crank/Spindle- Stainless steel AISI- 410/ Gr 1.4021 Body Seat Ring- Stainless steel AISI- 316/304/ Bronze IS:318- LTB2 ,Seal ( O- ring / Quad ring)- EPDM/ NBR, Bearing Bush - Bronze IS:318- LTB2,Slotted cylinder / Strainer / Diffuser- AISI- 420/ 304,Nut- Bolts - SS, Face to Face- as per ANSI B 16.1/ EN 558-1 and Flange ends should be as per ANSI B-16.5, Class 150 and Class 300/ EN-1092-2. Insertion rubber of black EPDM 6mm thick ,Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied both inside and outside . Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning as per Technical Specification & as per direction of Engineer-In- Charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 56 | PHED (R) BSR 2023 - 6.15.1 - Plunger Type Flow Control Valve |
| 57 | PHED (R) BSR 2023 - 6.15.1.2 - 100mm dia |
| 58 | PHED (R) BSR 2023 - 6.15.1.5 - 200mm dia |
| 59 | PHED (R) BSR 2023 - 6.17 - Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning Technical Specifications and as per direction of Engineer. Class PN 1.0 |
| 60 | PHED (R) BSR 2023 - 6.17.2 - 100 mm dia. |
| 61 | PHED (R) BSR 2023 - 6.17.5 - 200 mm dia. |
| 62 | PHED (R) BSR 2023 - 6.17.6 - 250 mm dia. |
| 63 | PHED (R) BSR 2023 - 6.18 - Providing, lowering, laying, aligning, fixing in position and jointing MS dismantling joint (Fabricated Steel) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning Technical Specifications and as per direction of Engineer. |
| 64 | PHED (R) BSR 2023 - 6.18.1 - 80 mm dia |
| 65 | PHED (R) BSR 2023 - 6.18.2 - 100 mm dia. |
| 66 | PHED (R) BSR 2023 - 6.18.4 - 150 mm dia. |
| 67 | PHED (R) BSR 2023 - 6.18.5 - 200 mm dia. |
| 68 | PHED (R) BSR 2023 - 6.18.6 - 250 mm dia. |
| 69 | PHED (R) BSR 2023 - 6.18.7 - 300 mm dia. |
| 70 | PHED (R) BSR 2023 - 6.18.9 - 400 mm dia. |
| 71 | PHED (R) BSR 2023 - 7.2 - SITC STAR DELTA Starter type LT Panel of following rating: all switchgears are of PHED approved makes, CRCA sheet of Panel enclosure is of TATA/ Essar 1.6mm/ 2.0mm thick duly Electrostatic Powder Coated with angle frame including other ancillaries ( Insulators, Acrylic Sheet , Backlight Sheet, Hardware, Wire, Name Plates, Lugs, Pvc Channel , Mcb Chanel , Lock, Hing , Bidding , Connectors, Neutral Links , Spiral , Saddle & Packing Material ) etc. and 100A/ 125A ,TPN, Aluminium Bus Bar with Colour coated heat shrinkage sleeves complete as per Technical Specifications and as per direction of Engineer-In-Charge. |
| 72 | PHED (R) BSR 2023 - 7.2.1 - STAR DELTA STARTER 7.5 KW (10.0 HP) - : For 2 motors (1 W+ 1S) I/C - MCB 63A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 60/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G- MCB 32A ,TP, 10 KA, C Curve (2), Power Cont 18A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (7-10A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 5Kvar (2), S/D Timer(2) |
| 73 | PHED (R) BSR 2023 - 7.2.5 - STAR DELTA STARTER 18.5 KW (25.0 HP) - : For 2 motors (1 W+ 1S) I/C- MCCB 125A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (1),Spreaders (2),Extended Rotary Handle (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 125/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G- MCCB 100A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (2), Power Cont 32A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (16-24A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 10 Kvar (2), S/D Timer(2) |
| 74 | PHED (R) BSR 2023 - 8.2 - Construction of boundary wall of Brick/ stone masonry as per enclosed GA drawing, scope of work and technical specifications complete work in all respect. Brief details of boundary wall parameter is as below:1. Depth of foundation- 900 mm.2. PCC in M-10, width -900 mm and thickness 100 mm,3. Stone masonry in CM: 1:6 section of foundation above PCC, 600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D) 4. Superstructure work: Stone masonry in CM: 1:6, W-300, height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm.5. Cement mortar pointing on Stone masonry and cement mortar plaster 20 mm thick on brick masonry in CM 1:6.6. Expansion joint shall be on every 30 mtr.7. On top of wall there shall be CC Coping 75 mm thick (1:2:4) shall be provided.8. Pillar for main gate 350x350 mm in size is part of boundary wall.9. Cement paint of approved colour in 3 coat shall be done. |
| 75 | PHED (R) BSR 2023 - 8.3 - Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamel paints. |
| 76 | PHED (R) BSR 2023 - 8.4 - Construction of Pump house of RCC framed structure as per approved standard GA, structure, electrical drawing, scope of work and technical specification complete work in all respect including electrical works for indoor and outdoor lighting and fans, rain water drainage, sanitary, plumbing, monorail/ EOT crane etc for Earth quake zone II and SBC equal to or more than 7 T/sqm.Note: Standard drawings can be viewed on website https://pheddms.rajasthan.gov.in/private/public/dms_document.aspx. |
| 77 | PHED (R) BSR 2023 - 8.4.4 - Type IV ( 212.9 Sqm) |
| 78 | PHED (R) BSR 2023 - 9.1 - Construction of RCC Sluice valve chamber for different type of valves including earthwork excavation, 100mm PCC M15 as levelling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast slabs, plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as per direction of Engineer-in-Charge. |
| 79 | PHED (R) BSR 2023 - 9.1.1. - For Class-AA loading |
| 80 | PHED (R) BSR 2023 - 9.1.3.1 - Sluice valve chamber of size1.13m x0.85m x1.225mfor pipe size-upto100mm |
| 81 | PHED (R) BSR 2023 - 9.1.3.3 - Sluice valve chamber of size1.26m x1.185m x1.76mfor pipe size-from 200-to-300mm |
| 82 | PHED (R) BSR 2023 - 9.2 - Construction of RCC Air valve chamber for different type of valves including earthwork excavation, 100mm PCC M15 as levelling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast slabs, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as per direction of Engineer-in-Charge. |
| 83 | PHED (R) BSR 2023 - 9.2.1 - For Class-AA loading |
| 84 | PHED (R) BSR 2023 - 9.2.1.1 - Air valve chamber of size0.9m x1m x1.695mfor air valve size-from 50 mm-to-80mm |
| 85 | PHED (R) BSR 2023 - 9.3 - Construction of RCC Scour valve chamber wet type for different type of valves including earthwork excavation, 100mm PCC M15 as levelling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast slabs, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as per direction of Engineer-in-Charge. |
| 86 | PHED (R) BSR 2023 - 9.3.1 - For Class-AA loading |
| 87 | PHED (R) BSR 2023 - 9.3.1.1 - Scour valve chamber of size1.13m x0.85m x1.985mfor connecting pipe size-upto100mm |
| 88 | PHED (R) BSR 2023 - 9.5 - Construction of RCC pillar for following size of air valves including earthwork excavation, RCC M25 grade for base slab, vertical pillar, including cost of steel reinforcement ,GI (class-B)/MS vertical pipe, form work, proper curing of concrete work complete in all respect as per standard specifications and drawings and as per direction of Engineer-in-Charge. |
| 89 | PHED (R) BSR 2023 - 9.5.1 - Air valve pillar for air valves size of 80mm dia |
| 90 | PHED (R) BSR 2023 - 11.1 - SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, if required, and all materials required for making connection etc. complete in all respect as per technical specification and direction of Engineer In-Charge. Note: Rates are exclusive of tail piece / dismantling joints and earth work. (For Pump house outlet, and CWR inlet) |
| 91 | PHED (R) BSR 2023 - 11.1.2 - EFM 80 mm (For Pump Common Delivery) |
| 92 | PHED (R) BSR 2023 - 11.1.5 - EFM 150 mm (For OHSRs Inlet, Pump Common Delivery) |
| 93 | PHED (R) BSR 2023 - 11.1.6 - EFM 200 mm (Pump outlet) |
| 94 | PHED (R) BSR 2023 - 11.4 - SITC of Ultrasonic Level Transmitter suitable for measuring water level in reservoir, Normal Powered 24VDC, Type of Transmitter: Two Wire ( 4-20 mA), Cable Entry:1/2\\" NPT (F), Sensor Material: PP, slip-on Flange: 2 ½” Flange, Material of Construction for Slip-on flange: PP, output 4~20mA, HART compatible, accuracy +/_ 0.2 % as per detailed Technical specification, scope of work and direction of Engineer in charge. |
| 95 | PHED (R) BSR 2023 - 11.4.1 - Measuring range 0.0 to 6.0 mtr (At proposed and existing CWRs) |
| 96 | PHED (R) BSR 2023 - 13.2 - Design, construction, testing and commissioning of Rapid Gravity Filter Treatment Plant including all relevant civil, electrical , mechanical ,instrumentation, automization and SCADA works, chemical building and stores along with ancillary civil works as defined in scope of work, technical specification and provisions of CPHEEO manuals for the following capacity . |
| 97 | PHED (R) BSR 2023 - 13.2.1 - Cost of 200 KLH; 200KLH RGFP at Phulad |
| 98 | PWD BSR 2022-BSR 1.6 - Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sum on plan) including disposal of excavated eath, lead upto 50m and lift upto 1.5 m, disposed eath to be levelled and neatly dressed: All kinds of |
| 99 | PWD BSR 2022-2.7.1 - P & F Bib Cock (IS:8931 Mark) Superior quality of approved make :Brass 400 gm. 15 mm nominal bore. |
| 100 | PWD BSR 2022-2.8 - P & F Stop cock (IS:8931 Mark) superior quality & of approved make : |
| 101 | PWD BSR 2022-2.8.1 - Brass 400 gm. 15 mm nominal bore. |
| 102 | PWD BSR 2022-2.8.2 - Brass 750 gm. 20 mm nominal bore. |
| 103 | PWD BSR 2022-2.11.5 - P & F Ball Cock (IS: 1703 Mark) with Rod & P.V.C. Ball complete : -do- wt. 1000 gm. 40 mm. |
| 104 | PWD BSR 2022-2.26.3 - P & F PVC Storage Tank (IS: 12701 marked indicating the BIS license No.) of-approved make with cover, 25 mm dia' 1 M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc. complete of approved design. 500 ltr. Capecity |
| 105 | PWD BSR 2022-2.29 - Providing and fixing Polyethylene - Aluminium –Polyethylene (PE-AL-PE) Composite Pressure Pipes as per 15450 : 2004 U.V. stablised with carbon black having thermal stabillity for hot and cold water supply, capable to withstand temperature upto 80ºC including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers connectors etc.with clamps at 1.00 metre spacing.This include the cost of cutting chases and including testing of joints complete as per direction of Engineer In chargeInternal work - Exposed on Wall |
| 106 | PWD BSR 2022-2.29.2 - 1620 (20 mm OD) pipe |
| 107 | PWD BSR 2022-2.29.4 - 2532 (32 mm OD) pipe |
| 108 | PWD BSR 2022-2.31 - Providing and fixing Polyethylene - Aluminium –Polyethylene (PE-AL-PE) Composite Pressure Pipes as per 15450 : 2004 U.V. stablised with carbon black having thermal stabillity for hot and cold water supply, capable to withstand temperature upto 80ºC including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers connectors etc.with trenching & refilling and testing of joints complete as per direction of Engineer In chargeExternal work |
| 109 | PWD BSR 2022-2.31.2 - 1620 (20 mm OD) pipe |
| 110 | PWD BSR 2022-2.31.4 - 2532 (32 mm OD) pipe |
| 111 | PWD BSR 2022-3.2 - Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor five level excluding the cost of centering and shuttering. |
| 112 | PWD BSR 2022-3.2.3 - M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40mm nominal size). |
| 113 | PWD BSR 2022-4.2 - Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcement for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.M20 grade Nominal Mix / Design Mix |
| 114 | PWD BSR 2022 4.9 - Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc. |
| 115 | PWD BSR 2022 4.10 - Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : |
| 116 | PWD BSR 2022 4.10.1 - Walls (any thickness) including attached pilasters, buttresses plinth and string course. |
| 117 | PWD BSR 2022 - 4.13 - Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) |
| 118 | 4.13.2 - Hot rolled deformed bars (IS : 1139). |
| 119 | PWD BSR 2022-5.2.2 - Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 120 | PWD BSR 2022-BSR 6.1.6 - Random Rubble stone masonary for foundation and plinth in Cement Sand Mortar above 30 Cm. thick wall in : Cement Mortar 1:6 ( 1-Cement : 6-Sand). |
| 121 | PWD BSR 2022-BSR 6.2.6 - Random Rubble stone masonary for superstructure above plinth level one storey height above 30 Cm. thick walls in : Cement Sand Mortar 1:6 |
| 122 | PWD BSR 2022-6.17 - Supplying and fixing machine cut and polished stone shelves, tands and sills in CM 1:3 with machine cut edges: |
| 123 | PWD BSR 2022-6.17.2 - Sand or other approved stone 50 mm thick. |
| 124 | PWD BSR 2022-6.17.3 - Kota stone minimum 30mm thick. |
| 125 | PWD BSR 2022-7.12 - Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). |
| 126 | PWD BSR 2022-9.2 - Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: |
| 127 | PWD BSR 2022-9.12.1 - Providing and fixing 1mm thick M.S. sheet garrage door shutters with frame of 40 x 40 x 6mm. angle iron 3mm M.S. gusset plates at the junction and corners including all fittings and applying a coat of approved steel primer : (Excluding cost of frames) ; Using M.S. angles 40 x 40 x 6mm for diagonal braces |
| 128 | PWD BSR 2022-9.17 - Providing and fixing M.S. sheet 1mm thick single leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint |
| 129 | PWD BSR 2022-9.26 - Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150 mm distance. |
| 130 | PWD BSR 2022-9.27 - Providing and fixing Square bars or other flat welded to window, ventilators etc. |
| 131 | PWD BSR 2022 9.31 - 150cm high fencing with angle iron 50x50x6mm. placed at every 3Mtr. apart 30cm. in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth post to be strutted with 50x50x6mm. angle iron provided with 5 horizontal lines and two diagonals of black barbed wire between two posts fitted and fixed with G.I. staples including earth work in excavation etc. complete. |
| 132 | PWD BSR 2022-10.2 - Providing and fixing 20 mm thick precast terrazo tiles of approved make, with marble chips of size upto 6mm laid over roof with neat cement slurry mixed with pigment to match the shade of the tiles, including cutting ,grinding rubbing with machine complete on 20 mm thick bed of cement sand mortar 1 : 4.. |
| 133 | PWD BSR 2022-10.16 - Stone slab roofing on ground floor with fine grained stone slab from approved quarry including filling of joints of parapet and slab on both sides in cement sand mortar 1:4, with ceiling pointing in cement sand mortar 1 : 3 complete as per specification and instruction of Engineer In Charge |
| 134 | PWD BSR 2022-11.4 - Providing and fixing 50mm thick cement concrete flooring with Metallic concrete hardener topping, under layer of 38mm thick cement concrete 1:2:4 (1-cement : 2-coarse sand : 4- graded stone aggregate 20mm thick nominal size) and top layer of 12mm thick metallic concrete hardener consisting ofmix 1:2 (1 cement : 2 stone aggregate, 6mm nominal size) by volume & mixed with metallic hardening compound of approved quality @ 2Kg./Sqm including cement slurry, rounding off edges etc. but excluding the cost of nosing of step etc. complete. |
| 135 | PWD BSR 2022-11.18.2 - Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand)For area of each slab from 2001 to 5000 Sq.Cm |
| 136 | PWD BSR 2022 11.38.1 - Providing and laying of paver block as per IS 15658 : 2006(Indian standard for precast concrete block for pavingspecification)and IRC : SP:63-2004 (guidelines for the use ofinterlocking concrete block pavement) M-30, 60 mm thick to be used in non traffic areas like buildingpremises, monument premises, land scapes, public gardens/park, domestic drives, paths and patios, Embankment slopes,sand stabilization Area etc.( As per table 1 of IS 15658:2006. Category A Denated units to key into each other on four faces |
| 137 | PWD BSR 2022-12.1.2 - Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete ine finished: 20 mm thick. |
| 138 | PWD BSR 2022-12.31.1 - Pointing on stone masonary in cement sand motar 1:3 (1Cement:3-Sand) :Flush or ruled pointing |
| 139 | PWD BSR 2022-12.35.1 - Colour washing of all shades to give an even shade including all scaffolding : New work (two or more coats) with a base coat of white washing with lime. |
| 140 | PWD BSR 2022-12.37.1 - Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: New work (two or more coats) over and including scrapping surface and necessary repers- colur Change |
| 141 | PWD BSR 2022-12.34.1 - White washing with lime to give an even shade including all scaffolding: |
| 142 | PWD BSR 2022-12.45.3 - With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works |
| 143 | PWD BSR 2022-13.1 - Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead With cement mortar 1 :4 ( 1 cement : 4 coarse sand) |
| 144 | PWD BSR 2022-13.12 - Repair to stone masonary in cement sand motar 1:6 with old and new stone |
| 145 | PWD BSR 2022-14.25 - Dismantling stone slab/ terrazo chip flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meters lead. |
| 146 | PWD BSR 2022-BSR 16.1 - Providing and fixing aluminum work for doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285, fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and the directions of Engineer- in – charge .(Glazing and paneling to be paid for separately). |
| 147 | PWD BSR 2022-16.1.1 - For fixed portion |
| 148 | PWD BSR 2022-16.1.1.1 - Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) |
| 149 | PWD BSR 2022-BSR 16.1.2 - For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). |
| 150 | PWD BSR 2022-16.1.2.1 - Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) |
| 151 | PWD BSR 2022-16.5 - Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basic item.) |
| 152 | PWD BSR 2022-16.5.2 - With float glass panes of 5.0 mm thickness ( weight not less than 13.50 kg/sqm) |
| 153 | PWD BSR 2022-17.5 - Repair to damaged plaster with high performance curing free, quick setting cement mortar & confirming to ASTM C 1600 in ratio of 1:4 with following properties of cement : Compressive strength of 20 MPa within 4 Hours, Curing free, bond strength of 4 MPa within 24 Hours, Non shrink & Non toxic in following steps Chopping loose and cracked plaster to required depth, cleaning the exposed surface with wire brush, cleaning of plaster surface with water as necessary and getting dried.Plastering the surface with above mentioned high performance cement sand mortar 1:4 upto depth of 25 mm complete with all scaffolding.No curing has to be done as the high performance cement used should be curing free. (This item is to be used in only emergency situation after decided by Engineer in charge ) |
| 154 | PWD BSR 2022 S-1.2.1 - P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: Size 530x410mm. |
| 155 | PWD BSR 2022 S-1.14.1 - P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete. ; Flat Back (small) size 456x355x265mm |
| 156 | PWD BSR 2022 S-1.29.1 - P&F C.P. brass Urinal Spreader for stall urinal of approved make. |
| 157 | PWD BSR 2022 S-1.36.2 - P&F WVC Wash basin (1st quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make 25 mm G.I. waste pipe complete including cutting & making good the wall :. Size 510'mm x 400mm |
| 158 | PWD BSR 2022 S-1.38.1 - P & F kitchen & Lab Sink of approved make with C.I. brackets duly painted, 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up to floor level complete including cutting and making good the wall & floor IS 771 (Part-II) -1985.Fire clay glazed kitchen sink (IS Marked) size 600x450x250 mm. |
| 159 | PWD BSR 2022 S-1.47.1 - P&F towel rail or ring of approved quality /make:C.P. brass towel rail elbow type with concealed screws size 450mm (heavy duty) |
| 160 | PWD BSR 2022 - S- 3.24 - Construction of Soakage well in all types of soil of approved drawing, top 90 Cm .Portion in 450mm thick masonry with CM 1:6, 80 mm thick stone slab covering, jointing of slab in CM 1:3 ,Ralthal, kharanja 40mm thick M-15 grade C.C flooring, earth work etc . complete including disposal of surplus earth within a lead of 50 mtr . |
| 161 | 3.24.1 - Inner dia 90 Cm & 10 to 12 Mtr deep. |
| 162 | PWD 2022-H-1.2 - Supply of Chemical Fertilizers at store in bags weighing not less than 50 kg each including loading unloading & transportation |
| 163 | 1.2.1 - Urea |
| 164 | 1.2.2 - DAP |
| 165 | 1.3 - Supply & Stacking good soil of earth at site complete including loading unloading & Transportation etc. |
| 166 | 1.3.1 - Good soil of earth |
| 167 | PWD 2022-H-1.4 - Supply of insecticides & Pesticides at store in dust/liquid form complete. |
| 168 | 1.4.1 - Methyl Prathion 2% |
| 169 | PWD 2022-H-1.11 - Supply of different varities of tree/shrubs/climbers according to height and age of the plant at side including loading/unloading & transportation etc.complete |
| 170 | 1.11.1 - Different flowering plants 900mm to1500mm |
| 171 | 1.11.2 - Different varieties of shrubs 600mm to 900 mm |
| 172 | 1.11.3 - Different varieties of climbers 900mm to 1500 mm |
| 173 | PWD 2022-H-1.12 - Supply of different varieties of bougainvillea in ply bags/earthen pot according to height growth and age of plant at site including loading unloading and transportation etc. complete |
| 174 | 1.12.1 - Local variety of bougainvillea 600mm to 900mm |
| 175 | 1.12.2 - Different varieties of bougainvillea 600mm to 900mm |
| 176 | PWD 2022-H-1.13 - Supply of different varieties of rose plants in poly bag/ earthen pot according to height growth and age of the plant at site including loading unloading and transportation etc. complete |
| 177 | 1.13.1 - Desi rose / root stock plant 1 to 1.5 feet |
| 178 | 1.13.2 - Ganganagari rose plant in poly beg 1 to 2 feet |
| 179 | 1.13.3 - Different varieties of grafted rose plants in poly bag 1 to 1.5 feet |
| 180 | 1.13.4 - Different varieties of grafted rose plants in poly pot/earthen pot 1 to 1.5 feet |
| 181 | PWD 2022-H-3.1 - Laying of lawns including ploughing leveling breaking of clods manuring and removal of stones etc. (cost of manure or extra good earth to be paid separately )maintenance of lawn foe 30 days or more till the grass forms a thick lawns free from weeds and fit for moving in the duration of planting if lawn die some where the contractor will replant it at his own cost |
| 182 | 3.1.1 - In rows 15 cm apart in either direction |
| 183 | PWD 2022-H-3.4 - Preparation of different sized bed as directed |
| 184 | PWD 2022-H-5.2 - Supply & Panting of ornamental plants ( Kachnar, Amaltas, Gulmohar, Arjun, Kala, Siris, Jacranda etc. or other specified) along road side including the following activities :-(i) Preparation of soil including cleaning & removing of unwanted shrubs removal of stones & garbage(ii) Supply of plant at site of two years of age & height more than 1.50 Mtr.(iii) Supply of dry manure( Farm yard manure organic)(iv) Supply of Insecticides(v) Digging of pits size 60x60x60 cms. Including removal of stones. Manuring application of insecticides & watering at least 1.5 liter per plant after planting. |
| 185 | PWD Electric BSR 2022-1.3 - Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 186 | PWD Electric BSR 2022-1.3.1 - On board |
| 187 | PWD Electric BSR 2022-1.3.2 - Short point (up to 3 mtr.) |
| 188 | PWD Electric BSR 2022-1.3.3 - Medium point (up to 6 mtr.) |
| 189 | PWD Electric BSR 2022-1.3.4 - Long point (up to 10 mtr..) |
| 190 | PWD Electric BSR 2022-1.5 - Rewiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick MS box with earth terminal, 6 A switch, 3 pin ceiling rose/holder / 3 way connector , 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 191 | PWD Electric BSR 2022-1.5.1 - Short point (up to 3 mtr.) |
| 192 | PWD Electric BSR 2022-1.5.2 - Medium point (up to 6 mtr.) |
| 193 | PWD Electric BSR 2022-1.5.3 - Long point (up to 10 mtr.) |
| 194 | PWD Electric BSR 2022-5.1.1 - P & F 1.2 mm thick G. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR : 1.2 mm thick M. S. Sheet boxes |
| 195 | PWD Electric BSR 2022-5.1.1.1 - 75mm x 75mm x 60mm |
| 196 | PWD Electric BSR 2022-5.1.1.3 - 150mm x 75mm x 60mm |
| 197 | PWD Electric BSR 2022-6.1.2.2 - Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSRDouble pole MCB(With B/C curve tripping Characteristics) : 6 A to 32 A rating |
| 198 | PWD Electric BSR 2022-7.1 - P & F ISI marked (IS:3854) 6 amp. flush type non modular switch with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 199 | PWD Electric BSR 2022-7.13 - Providing & Fixing of ISI marked (IS:1258) batten/angle lamp holder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 200 | PWD Electric BSR 2022-7.36 - Providing and fixing of power plug point with non modular accessories as per PWD specification for electrical Works with Galvanized box of 1.2 mm thick with earth terminal with suitable size phenolic laminated sheet (IS : 2036 - 1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outlet making connection , testing , etc. as required. . For specification of Wiring accessories refer Chapter E - 07 related item & For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 201 | PWD Electric BSR 2022-10.5.1 - Providing & Fixing of ISO certified company made 240/415 V porcelain kitkat fuse (/HBC type) as per PWD specification for electrical Works conforming to IS:2086,1983 on existing board/ sheet including making connections with lugs, testing etc. as required . Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . : 16 A ,240 V |
| 202 | PWD ELECTRIC 2022 11.3 - Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 203 | 11.3.4 - 6.0 Sq. mm |
| 204 | 11.3.4.1 - 2 core |
| 205 | PWD ELECTRIC 2022 14.6 - Supply & Laying following size earth wire in horizontal or vertical run inground/surface/recess including riveting, soldering, saddles, makingconnection with GI/Cu purity purity >95% thimble etc. as required. All asper pre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure \\"A\\" attached with thisBSR . |
| 206 | 14.6.3 - 10 SWG G.I. ( Hot Dipped ) Wire |
| 207 | PWD Electric BSR 2022-15.7.1 - Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . : 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) |
| 208 | PWD Electric BSR 2022-15.9 - Providing & Fixing of of M.S. J- hook of standard design made out of 16 mm dia. M.S. round bar and fixed with cement concrete mortar with required support as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 209 | PWD Electric BSR 2022-17.2.1 - Providing & Fixing of energy efficient direct fit (Retrofit) Polycarbonate/ Glass housing SMD Mid Power LED tube rod (with integral driver & alumn. heat sink ), on existing fixture. system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum 35000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . : 600mm , Min. Lumens output 1800 lm LED Tube rod with Polycarbonate Housing |
| 210 | PWD ELECTRIC 2022 18.1 - Supply and erection of Galvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 with base plate and foundation bolt on the Existing cement concrete foundation.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 211 | 18.1.1 - Poles with Octagonal Cross Section |
| 212 | 18.1.1.7 - 9 Mtr. |
| 213 | PWD ELECTRIC 2022 18.2 - Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 214 | 18.2.1 - Single arm overhang |
| 215 | PWD ELECTRIC 2022 18.8.2 - Providing and Laying RCC Foundation for Octagonal / Conical Street Light poles, High mast Poles as per Drawing attach at Table P-4 with Following Procedure & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . A) Excavation of Pit for Foundation Size upto required depth from Ground level B) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surface complete. C) Providing and laying in position cement concrete of M-10 grade of 75 mm thickness D) Reinforcement for R.C.C. work with TMT bars including straightening, cutting, bending, placing in position and binding all complete. E) Centring and shuttering including strutting , propping etc. and removal of form work for Footing and Pedestal F) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEM Recommendations. G) Providing and Laying Reinforce cement Concrete of M-25 grade in Footing and Pedestal including Curing the foundation for 7 days. H) Providing and Fixing Nosing Angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. Lugs on each face. Pole Foundation for Octagonal pole from 7 Mtr. To 9 Mtr. |
| 216 | PWD ELECTRIC 2022 18.12 - Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 217 | 18.12.1 - LED Street Light fixture with Minimum lumen output 2450 lm |
| 218 | 18.12.2 - LED Street Light fixture with Minimum lumen output 3700 lm |
| 219 | PWD ELECTRIC 2022 18.17 - Providing and fixing of IP 65 protected Polycarbonate / Polysterene fuse box moulded with inside knock outs of following size with hinged cover, transparent window, PU gasket, locking arrangement, duly holded with 2 nos. pole clamps of 20 mm x 3 mm flat with nut and bolts, The box shall be provided with Din rail, 4 / 8 way 10.0 / 16.0 sq.mm heavy duty connector, earth terminal, complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 220 | 18.17.1 - 125 mm X 200 mm X 122 mm |
| 221 | PWD ELECTRIC 2022 18.18 - Providing & Fixing of Street light bracket made out from following size of ' B ' class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 222 | 18.18.1 - 20 mm Dia. |
| 223 | RUIDP 2023 - 2.3 - Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to a lead of 50 metres from road boundary including removal and disposal of top organic soil not exceeding 150 mm in thickness as directed by Engineer. |
| 224 | 2.3.1 - In area of light jungle |
| 225 | RUIDP 2023 ISOR 15.7 - Providing, constructing coffer dam in river basin / dam storages asper type design including excavation, filling the middle portion withB.C. soil (in gunny bags if required). Providing impervious /semipervious materials on both sides of B.C. soil (in gunny bags ifrequired) including ramming, compacting to the satisfaction ofEngineer-in-charge till the completion of work including dismantlingcoffer dam after completion of works and disposing off the materialas directed by the Engineer-in-charge. Note : Maximum top widthpayable shall be 2 Mtr. and maximum payable side slopes shall be1.5 horizontal to 1 vertical, if the constructed top width of the sideslopes are less, then the measurements at actual are payable. Extratop width or flat slopes are not payable. Contractor is free to useballies, plastic sheets, piles, pipes, CGI sheets for supportinghearting materials instead of impervious/ semi-pervious heartingmaterials for which no extra payments shall be payable. 30%payment shall be withheld for dismantling of coffer dam. |
| 226 | RUIDP 18.6.1 - Supply, Installation, Testing and commissioning of CI Open ChannelSluice Gates, Manually operated, Rising Spindle type suitable formounting in between two parallel walls of an Open Channel. Watersealing shall be provided at two vertical sides and bottom side ofgate aperture by means of rubber seal, mounted on gate slide andhaving forced contact with gate aperture. The gate shall be designedin such a manner, so that it can be operated at 2 meter head. Gateframe & Shutter of CI Grade IS 210 FG 260, Head Stock IS 210Grade FG 260, Hinge Pin SS ASTMA276, Yoke IS MS 2062, FlushBottom Seal Support Bar of SS ASTM A276 , Stem Operating NutASTM A276., Duly tested for tensile strength, Chemical testing andtested Shop tested for overall dimensions as per approved GAdrawing complete in all respect as per specification and direction ofEngineer for following PEAK FLOW up to 3m channel depth. Up to 5 MLD |
| 227 | RUIDP 2023- 18.10.2 - Supply, installation and commissioning of Mono Rail Single Girder Crane suitable for lift up to 9m with chain 9m pulley block and traveling trolley excluding cost of girder complete in all respect as per the direction of the Engineer. 2 MT Capacity |
| 228 | RUIDP 2023- 23.3.5 - Reinforced cement concrete work in beams, suspended floors,roofs having slope upto 15° landings, balconies, shelves, chajjas,lintels, bands, plain window sills, staircases and spiral stair casesupto two stories excluding the cost of centring, shuttering, finishingand reinforcement: including Providing /mixing of synthetic fiberscompulsorily complying with IS 16481:2022 of 06 mm/12 mm lengthto be mixed @ 0.25% by weight of Cement i.e. 125 gms per 50 kgCement up to 900 gms per cum of Concrete/ mortar: M35 grade concrete |
| 229 | RUIDP BSR 2023 25.1.1 - Random rubble masonry with hard stone in foundation and plinth : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 230 | RUIDP BSR 2023 25.2 - Extra for random rubble masonry with hard stone in superstructure above plinth level and upto two stories. |
| 231 | RUIDP BSR 2023 - 42.33 - P/Laying P.V.C/XLPE insulated & P.V.C sheathed cable of 1.1 KV grade with Copper conductor of IS: 1554 P-I/IS: 7098 P-I in ground as per IS: 1255 including excavation of 30cm x 75cm size trench, 25cm thick under layer of sand, IInd class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. |
| 232 | 42.33.1 - 2.5 sqmm. Armored 4 core |
| 233 | 42.33.2 - 1.5 Sq.mm Armoured 6 Core |
| 234 | RUIDP 2023 43.9 - Providing, installation, testing and commissioning of glycerin filled Pressure gauge of following ranges with isolation valve and tap off pipe complete in all respect as per technical specification and as per direction of Engineer. 0 to 10.0 kg/cm²It is Required for each Pump 2 Nos for Suction Side and Delivery Side |
| 235 | RUIDP SOR 2023 - 44.6 - SITC of Soft Starters with panel supplied by manufacturer conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus. |
| 236 | 44.6.2 - 30 KW |
| 237 | 44.6.3 - 37 KW |
| 238 | RUIDP 2023 - 57.1 - SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. |
| 239 | - [c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra ) |
| 240 | - (d)Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.(e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee |
| 241 | 57.1 - (d)Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.(e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee |
| 242 | RUIDP 2023 - 57.2 - Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator with standard short circuit withstand capacity , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 243 | 57.2.1 - Electrolytic grade Aluminium bus bar 6010 grade |
| 244 | RUIDP 2023 - 57.3 - Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digitaltype (up to 500) V range Volt meter / Direct- Ammeter / CT oertatedammeter/ Frequency meter / KWH meter / Multi Function Meter /Power analyzer of class 1 accuracy as per IS : 1248 of size 96mm x96 mm including making connection by PVC insulated copperconductor with PVC sleeves / channel etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached withthis BSR . |
| 245 | 57.3.10 - Three phase with universal Auxiliary supply + AMP + HZ + PF + KW+ KVA + KVAR + KVARH + KWH + DUAL ENERGY+ENERGY+THD-I, THD-V & RUN HRS + MD with RS485 |
| 246 | RUIDP 2023 - 57.4 - Providing & Fixing of BIS approved Current Transformer as perPWD specification for electrical Works ,ISI marked as per IS 27051992/conforming to IEC 60044-1, with secondary terminal of CTshall be brought out suitable to a terminal block which shall beeasier accessible for testing and terminal connection , with allnecessary support in existing panel including connection etc. asrequired Current transformer Ring Type Tape Wound/Resin CastWound as per IS 16227 with, Accuracy Cl, CT ratio and burden asspecified. ISF<=5, Cu cross section of secondary wire 1.5sqmm(minimum), including all necessary support in existing panelincluding connection etc. as required . All as per pre approved byEngineer in-charge.All as per pre approved by Engineer in-charge.For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 247 | 57.4.1 - Ring type tape wound CT |
| 248 | 57.4.1.2 - C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA |
| 249 | RUIDP 2023 - 57.9 - Providing & Fixing of flush head push button actuators IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, including connection etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 250 | 57.9.1 - Non luminous type |
| 251 | 57.9.2 - Luminous type Red , Yellow, Green, Amber |
| 252 | RUIDP 2023 - 57.10 - Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 / 2006 with one side anti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR |
| 253 | 57.10.1 - 3.3 KV, class A 2 mm thick with proof voltage 10 KV AC (rms) and Break Down Voltage 30 KV AC (rms) (For Electric Panel and APFC Panel at proposed/ Existing Pump Houses) |
| 254 | RUIDP 2023 - 57.11 - Providing & Fixing of self healing IP20 MPP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 OR IEC : 60831-1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz, Operating loss less than 0.30 Watt per KVAR. Min over current capacity 1.8 times rated current & peak inrush current min. 300 times of rated current, llife expectancy greater than 100000hrs (temp class - 25 D) in 440 V/480 V Capacitor and for 525 V should life expectancy minimum 1,65,000 hrs (temp class - 25 D) including making connections, testing etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 255 | 57.11.1 - Heavy duty Three phase 440 V, 50 Hz cylindrical type capacitor (Bank) |
| 256 | RUIDP 2023 - 57.13 - Providing & Fixing of IP54 microprocessor based 3 CT’s for all 3 phase sensing compensation power factor correction relay Size 139mm x 139 mm, Operating Voltage 415/440 V , IEC / EN 61000-6-(2&4) having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR, RMS Value, step switching time 2 sec to 1800 sec. Lead & Lag parameters, metering facility and 3 no. Class- 0.5 Cast Resin CT ( refer CT specs in this chapter )for sensing the relay including making coonection with 1.5 Sq.mm copper wire etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 257 | 57.13.1 - 6 to 8 stage |
| 258 | RUIDP 2023 - 59.1 - Providing & Fixing of ISO certified company made TP&N 415 V sidehandle operated double break fuse switch unit in sheet steelenclosure as per PWD specification for electrical Works conformingto IS/lEC 60947-3 : 1999 (W/O HBC fuses) including makingconnections with suitable lugs, testing etc. as required. Appropriatetype test certificate / OEM test report shall be submitted . All as perpre approved by Engineer in-charge. For additional technicalparameters of products/ work , refer Annexure \\"A\\" attached withthis BSR . |
| 259 | RUIDP 2023 - 59.1.2 - 100 A rating |
| 260 | RUIDP BSR 2023 60.2 - Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Unarmoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity >99.6 % & as per IS:1554 P-I / IS :7098 P – I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures. (c) OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR. |
| 261 | 60.2.4 - Armoured Cable |
| 262 | 60.2.4 - 16 Sqmm |
| 263 | 60.2.4.2 - 3 core |
| 264 | 60.2.5 - 25 Sqmm |
| 265 | 60.2.5.3 - 3.5 Core |
| 266 | 60.2.6 - 35 Sqmm |
| 267 | 60.2.6.3 - 3.5 Core |
| 268 | 60.2.7 - 50 Sqmm |
| 269 | 60.2.7.3 - 3.5 Core |
| 270 | RUIDP 2023 - 61.5 - Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR |
| 271 | 61.5.2 - 150mm x 50mm x 1.6mm |
| 272 | RUIDP 2023 - 3800 - Water level indicator with 5 level indications, prons and cabling upto length of 5 metre |
| 273 | S.No.1a, Chapter V WRD, Pali - Excavation including loading, unloading, disposal and dressing of excavated earth within initial lead of 50m and lift up to 1.5m in dry or moist including dressing of excavated area, dewatering wherever required complete in all respect--Soft/Loose soil |
| 274 | S.No.11, Chapter V WRD, Pali - Add extra over item No. 5 for disposal of excavated material above initial lift of 1.5m and for every additional lift of 1.5m or part there of including loading and un- loading wherever required |
| 275 | S.No.12, Chapter V WRD, Pali - Add extra over item No. 1 to 5 for excavation under water for all type of strata including dewatering charges. (Quantity under water during actual work is only to be considered) Quantity of excavation below water level in foundation area during continous pump running should only be considered @ 25% |
| 276 | S.No.2 a, Chapter VIII BSR(WRD), Pali - Plaster in cement sand mortar 1:4 including racking of joints, smoothfinishing & curing etc. complete including all leads of allconstruction materials of thickness 20mm |
| 277 | S.No.8 c, Chapter IX BSR(WRD), Pali - Providing and Laying in position of Cement concrete Nominal mix(1:3:6) including leads of all construction materials, curing,compaction and finishing with rendering in cement sand mortar 1:3 (1cement : 3 coarse sand) and making good the joints excluding thecost of centering, shuttering and reinforcement. Well graded crusherbroken stone aggregate of maximum size upto; 40 mm |
| 278 | S.No.1a, Chapter XVIII WRD,Pali - Cutting & clearance of jungle, bushes, shrubs Ankra/ Ipomoea, Julicflora typna etc. on canal and bunds in dry/moist/slushy conditions including disposal as per instructions of the Engineer-in-charge. Cost of wood has been deducted from rates and thus will be property of contractor after cutting. |
| 279 | Providing, installation, testing, trial run and commissioning of the following, as per specifications Verticle Turbine Pumps & motor all other accessories of following duty conditions |
| 280 | VT Pumps at INTAKE Well 60.76 LPS/26m/29.5KW (1W+1S) |
| 281 | Operation and Maintenance of Intake Well, RGFP, Raw Rising main, Clear Water Rising pipe line, Clear Water Reservoir, Pump House, Pumping Machinary, SCADA & all Mechanical, Electrical and Instrumentation work, etc. including all other works created under this project for period of Five years after 1 year defect liability period under Budget Announcement.The approved quoted amount for 5 years O&M shall be paid to the contractor in increasing trend in subsequent years.1st year O&M2nd Year O&M (1.05 to 1st year O&M)3rd Year O&M (1.05 to 2nd Year O&M)4th Year O&M (1.05 to 3rd Year O&M)5th Year O&M (1.05 to 4th Year O&M) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail