| 1 | M&L for rewinding the motor of table / pedestal / cabin fan 400 mm of all types and make with super enamelled copper wire of existing gauge and approved quality including overhauling and minor repairs for satisfactory operation, testing for the original speed & consumption complete. |
| 2 | M&L for rewinding the motor of ceiling fan 1200/1400 mm of any type and make with super enamelled copper wire of existing gauge of approved quality including overhauling and minor repairs for satisfactory operation, testing for the original speed & consumption complete. |
| 3 | M&L for rewinding the motor of fresh air/exhaust fan 230/300 mm of any type and make with super enamelled copper wire of existing gauge of approved quality including overhauling and minor repairs for satisfactory operation, testing for the original speed & consumption complete. |
| 4 | M&L for rewinding the motor of exhaust fan 375/450 mm of any type and make with super enamelled copper wire of existing gauge of approved quality including overhauling and minor repairs for satisfactory operation, testing for the original speed & consumption complete. |
| 5 | M&L for rewinding the motor of wall mount air circulator fan of size 400 to 600 mm of any type and make with super enamelled copper wire of existing gauge of approved quality including overhauling and minor repairs for satisfactory operation, testing for the original speed & consumption complete. |
| 6 | Supply only ball bearing no- 6201 to 6204 of ceiling / exhaust fan etc. of any size and make as required with alignment of shaft and testing complete all as specified and directed. |
| 7 | S&F in repair of AC film capacitor 2/2.5 mfd, 440 volts suitable for any type ceiling fan in FR plastic casing including connection complete all as specified and directed. |
| 8 | S&F in repair of AC film capacitor 4.0 mfd, 440 volts suitable for any type ceiling fan / exhaust fan in FR plastic casing including connection complete all as specified and directed. |
| 9 | Supply only shaft of approved quality for ceiling fan / exhaust fan any make any type & size as required complete all as specified and directed. |
| 10 | M&L for painting of table / pedestal / cabin fan of any sweep and make with one or more coats of spray painting with best quality enamel paint of required colour and approved brand to give an even shade and polishing with rubbing compound and wax polish including cleaning of surface with detergent etc complete all as specified and directed. |
| 11 | M&L for painting of ceiling fan of any sweep and make with one or more coats of spray painting with best quality enamel paint of required colour and approved brand to give an even shade and polishing with rubbing compound and wax polish including cleaning of surface with detergent etc complete all as specified and directed. |
| 12 | M&L for scraping completely fresh air / exhaust fan of any sweep and make and providing with two or more coats of spray painting with best quality enamel paint of required colour and approved brand to give an even shade over a coat of red oxide primer and polishing with rubbing compound and wax polish complete all as specified and directed. |
| 13 | Taking down ceiling fan / exhaust fan / wall fan / fresh air fan and transport to storeyard and repairing the fan as required and replacing unserviceable parts complete all as specified and directed. Note : All the spare parts to be replaced will be measured seperately as supply only under respective item of BOQ |
| 14 | Installing, testing and commissioning of repaired ceiling fan / exhaust fan / wall fan / fresh air fan and connecting up at any location in cantonment Jaipur incl transportion of ceiling fan from storeyard to site and wrighting SM no in black size letter etc incl provn of cable from ceiling rose to fan complete all as specified and directed. |
| 15 | Supply only rubber reel with a pair of clamp, nuts, bolts, split pins etc suitable for ceiling fan down rods of any size and make as required complete all as specified and directed. |
| 16 | Supply only PVC canopy suitable for ceiling fan of any size and make as required complete all as specified and directed. |
| 17 | Supply only down rod of ceiling fan made of MS pipe 15mm bore including cutting, threading, painting etc 30cm to 60cm long of approved quality complete all as specified and directed. |
| 18 | M&L for clamp and back plates fabricated from steel sections conforming to Gde Fe 410-O or Fe 310-O including nuts, bolts, washer, drilling holes for bolts in any shape or size for fixing ceiling fan complete all as specified and directed. |
| 19 | Supply only of PVC insulated and sheathed flexible 3 core cable with copper conductor of size 0.5 sqmm complete all as specified and directed. |
| 20 | S&F ceiling fan 1200mm sweep 50 Hz, AC 230 votls, 5 star rated in white colour with fan motor, blades, 0.45 mtr down rod, canopy set, rubber reel including 0.5 Sqmm three core PVC insulated flexible copper conductor multistranded wire from fan motor to ceiling and writing MES No. on fan body as required complete all as specified and directed. |
| 21 | Taking down carefully storage type water heater (geyser) any make and capacity from clamp/bolts including disconnecting water and electric connection, checking the serviceablity of all parts such as inner vesser, rubber gasket, non return valve, heating element, thermostat etc and refixing the same after replacing of unserviceable parts and assembly and re-fixing the same and connecting up after cleaning of geyser and repair complete all as specified and directed. (Note - Replacement of spare parts will be measured separately as supply only under respective items of BOQ ). |
| 22 | Supply only geyser apparatus plate (any make, any type) copper alloy chromium plated suitable for geysers 25/50 litre capacity including rubber gasket, nuts / bolts etc complete. |
| 23 | Supply only heating element 2.0 KW, 230 volts, ISI marked suitable for 25/ 50 litre capacity geysers of any type as required. |
| 24 | Supply only thermostat ISI marked suitable for 25/50 litres geysers as required. |
| 25 | Supply only stainless steel inner tank suitable for 25 litre capacity geysers complete. |
| 26 | Supply only stainless steel inner tank suitable for 50 litre capacity geysers complete. |
| 27 | M&L for repairing of inner copper tank of geysers 25/50 litre capacity with gas welding not exceeding 5 mm thick to make it leak proof complete all as specified and directed. |
| 28 | M&L for repairing of apparatus plate of geysers 25/50 litre capacity by brazing not exceeding 5 mm thick complete all as specified and directed. |
| 29 | Supply only dis cut out switch suitable for 25 litre capacity geysers complete all as specified and directed. |
| 30 | Supply only capillary thermostat set suitable for 25 litre capacity geysers complete all as specified and directed. |
| 31 | S&F in repair of brass chromium plated, flexible pipe connection 15 mm bore 450 mm long heavy duty suitable for hot water supply with two numbers brass chromium plated nuts at end complete all as specified and directed. |
| 32 | M&L for painting of geyser 25/50 litre with two coats of synthetic enamelled white paint after removing old paint and preparation of surface and writing MES No (Letters height 10 cm) complete all as specified and directed. |
| 33 | S&F in repair of PVC insulated over all PVC sheathed three core copper cable of size 2.5 sqmm complete all as specified and directed. |
| 34 | S&F in repair of chromium plated, PVC flexible pipe connection 15 mm bore suitable for hot water supply with two numbers brass chromium plated nuts at end complete all as specified and directed. |
| 35 | S&F in repair 3 pin plug top 16 Amps 250V including making connection complete all as specified and directed. |
| 36 | S&F water heater 25 litre capacity BEE star rating 5, approved colour, heating element 2.0 KW, adjustable temperature setting knob for temperature setting between 25° C to 75° C, outer tank made of metal, inner tank made of extra thick superior cold rolled steel provided with high density PUF insullation complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. complete all as specified and directed. |
| 37 | S&F in replacement fresh air fan of sweep 200 mm, made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, 1200 RPM, copper winding incl making connections complete all as specified and directed. |
| 38 | S&F in replacement fresh air fan of sweep 250 mm, made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, 1200 RPM, copper winding incl making connections complete all as specified and directed. |
| 39 | S&F in replacement fresh air fan of sweep 300 mm, made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, 1200 RPM, copper winding incl making connections complete all as specified and directed. |
| 40 | M&L for sub main wiring with two run of 4 Sqmm single core, PVC insulated, unsheathed, FRLS multistranded copper conductor cable alongwith one run of 4 Sqmm earth wire as earth continuity conductor (Phase-Red, Neutral-Black, Earth-Green) drawing into and including concealed rigid non-metallic PVC conduit of 20mm dia, ISI marked, ivory colour with fitting / fixing accessories of suitable size as required including making connection as required complete all as specified and directed. NOTE - Two run of 4 sq.mm phase and neutral wire, One run of 4 sq.mm earth wire & One run of PVC conduit with accessories shall be measured as One length. |
| 41 | ,---ditto-- all as per item No. 40 above but wiring with two run of 6 Sqmm and one run of 6 Sqmm earth in 20mm dia PVC conduit complete all as specified and directed. |
| 42 | ,---ditto-- all as per item No. 40 above but wiring with two run of 10 Sqmm and one run of 10 Sqmm earth in 20mm dia PVC conduit complete all as specified and directed. |
| 43 | S & F in repair 20 amp single pole and neutral enclosure with 2 pole and earth metal enclosed plug top in powder coated CRCA steel sheet enclosre recess mounted with chained matel cover for socket out let with and incl one no single pole MCB 20 Amps complete all as specified and directed. |
| 44 | Note:- (a) The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ Please Enable Macros to View BoQ information |