| 1 | Schedule 'A' Section - I |
| 2 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) and disposing off the rubbish materials where complete all as specified and directed |
| 3 | Demolition of brick work or stone masonary built in cement mortar including quions, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles and disposing off the rubbish materials where complete all as specified and directed. |
| 4 | Material & Labour for PCC (1:4:8 ) type- D2 (using 40mm graded aggregate) in foundation filling and mass concrete incl necessary form work. |
| 5 | Material & Labour for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:4 as in road side parapet / Drain all as specified and as directed |
| 6 | All as per item No 4.00 but except stone complete all as specified and directed |
| 7 | Material & Labour for raised pointing in CM (1:4) to random rubble square/polygonal rubbles uncoursed or brought upto courses complete all as specified and directed |
| 8 | Material & Labour for PCC Type B1 1: 2:4 (20 mm graded stone aggregate )Providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges as in coping ,kneelers,bond stone, coping etc. |
| 9 | PVC SWR pipes 75 mm dia in any length with rubber ring joints laid in trenches or wheep holes complete all as specified |
| 10 | Material & Labour for Rendering 15mm thick in cement plaster 1:4 on fair faces of brick work or concrete surfaces incl finishing surface without using extra cement complete all as specified and directed |
| 11 | Preparation of newly plastered surfaces of wall & applying two coat of cement based paint complete all as specified and directed |
| 12 | Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed |
| 13 | Supply and fixing Mild steel work for framed work such as grills, (12mm sqm bars for window / ventilators for guard bars) grating, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars, barred iron doors, ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed. |
| 14 | Material & Labour PCC 75mm thick 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in sub base of flooring all as specified and directed. |
| 15 | Material & Labour Prepolished Chequered cement concrete tiles 300mm x 300mm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement & pigment, over Screed bed of mortar 1:4, 20 mm in thickness for laying floor tiles. |
| 16 | Material & Labour for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade with grey cement and pigment set and jointed in neat cement slurry over 20mm thick screed bed in CM (1:6) as specified.all as specified and as directed |
| 17 | Material & Labour for cement concrete in surface channel and drain type C1 1:3:6 (20 mm graded agg) nd finishing surface even without using extra cement complete all as specified and dircted |
| 18 | Dismantling posts or struts (Wood, steel or RCC) any section including taking out embedded portion in concrete, brick work, masonary etc, and making good disturbed ground complete all as specified and directed |
| 19 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for |
| 20 | Supply and fixing for MS angle as a fencing post ,strut cutting tops in shape incl all necessary drilling, notching and reveting etc and similar work confirming to Fe-290 Gde E-165. |
| 21 | Material & Labour for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer etc,complete all as specified. |
| 22 | Dismantling fencing wire mesh, any type complete all as specified and directed |
| 23 | Supply only chain link fencing mild steel galvanised fencing any size or type complete all as specified and directed |
| 24 | Fixing only chain link fencing including line wires, any mesh, size and type of standards, rails, straining bolts, etc including provn of binidng wire complete all as specified and directed |
| 25 | Supply and fixing Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed screwed bothe ends, each screwed end to be fitted with washers and one hexagonal or square nut diameter of neck 5 to 10 mm exc 5 cm and n exc 10 cm long complete all as specified and directed |
| 26 | Supply and fixing in repairs Galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc as directed 9each line wire to measured) complete all as specified and directed |
| 27 | Supply only 10 mm dia mild steel plain round bar as in line wire for chain link fencing . |
| 28 | Material & Labour for preparation of new steel surfaces of any description n exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer etc,complete all as specified. |
| 29 | Taking down carefully copper/aluminium point wiring (light, fan, bell, socket, or power socket) complete fitting such as switches, sockets, lamp holder, utility light fitting, fan regulator, ceiling rose incl existing PVC/Steel conduit/ casing caping etc and removing materials from sites and making good distrubed surface of walls and roofs complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 30 | Taking down carefully copper/aluminium point wiring (light, fan, bell, socket, or power socket) complete fitting such as switches, sockets, lamp holder, utility light fitting, fan regulator, ceiling rose incl existing PVC/Steel conduit/ casing caping etc and removing materials from sites and making good distrubed surface of walls and roofs complete all as specified and as directed. Please Enable Macros to View BoQ information |