| 1 | Supply , laying & testing in repair for XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of size 16 Sqmm nominal cross section x 2 core complete all as specified and directed |
| 2 | ditto but Size 25 Sqmm X 3.5 core |
| 3 | ditto but Size 35 Sqmm X 3.5 core |
| 4 | ditto but Size 50 Sqmm X 3.5 core |
| 5 | ditto but Size 70 Sqmm X 3.5 core |
| 6 | ditto but Size 95 Sqmm X 3.5 core |
| 7 | ditto but Size 400 Sqmm X 3.5 core |
| 8 | ditto butt Size 120 Sqmm X3.5 core |
| 9 | Supply and fixing of GI tubing, light grade, 40 mm bore with all fitting laid in trenches / pole / wall for protection of cables in repairs complete. |
| 10 | Supply and fixing of GI tubing, light grade, 80 mm bore with all fitting laid in trenches / pole / wall for protection of cables in repairs complete. |
| 11 | Supply and fix in repair cable jointing kit cold shrink type for 1.1 KV grade cable for straight through joint complete with Jointing material of tubular sleeve version and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 25 to 50 sq mm complete . Make- Raychem/ Denson/3M. |
| 12 | Supply and fix in repair cable jointing kit cold shrink type for 1.1 KV grade cable for straight through joint complete with Jointing material of tubular sleeve version and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 70 to 150 sq mm complete .Make- Raychem/ Denson/3M. |
| 13 | Supply and fix in repair cable jointing kit cold shrink type for 1.1 KV grade cable for straight through joint complete with Jointing material of tubular sleeve version and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 185 to 400 sq mm complete .Make- Raychem/ Denson/3M. |
| 14 | S&F in replacement of Danger notice plate of 1.6mm thick mild steel sheet vitreous enameled white with letter figures and conventional skull and bones in signal red colour and fix with MS clamp/Nut bolt for LT complete all as specified. |
| 15 | Supply only Aluminium lugs of any type complete all as per of sample of following sizes :- |
| 16 | (a) 16 Sqmm |
| 17 | (b) 25 Sqmm |
| 18 | (c) 50 Sqmm |
| 19 | (d) 70 Sqmm |
| 20 | (e) 95 Sqmm |
| 21 | (f) 120 Sqmm |
| 22 | (g) 150 Sqmm |
| 23 | (h) 240 Sqmm |
| 24 | (i) 300 Sqmm |
| 25 | Supply & Fixing in repair including making connection testing and commissioning of new MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA.Note: (a) make of MCCB shall be L &T , Havells, Strandard, crompton, C & S, Schneider or any other make as per the make in the existing pannel board or exactly suitable to the existing frame size. In case only one particular make is procuring by the bidder necceasry alteration required to fix the same at no extra cost shall be done by the bidder .(b) Type of MCCB weather with operating knob or handle type shall be procured as per site requirement. |
| 26 | Ditto, but MCCB TP 160 Amps, 36 KA with Adjustable thermal setting ( 80 to 100 %) complete. |
| 27 | Ditto, but MCCB TP 250 Amps, 36 KA with Adjustable thermal setting ( 80 to 100 %) complete. |
| 28 | Ditto, but MCCB TP 125 Amps, 16 KA with Adjustable thermal setting ( 80 to 100 %) complete. |
| 29 | Ditto, but 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA. |
| 30 | Ditto, but 4 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA. |
| 31 | Ditto, but 4 Pole, 415 V, Adjustable type, 630 Amps with breaking capacity 50 KA. |
| 32 | M&L for defect rectification in LT/HT cable laid in trenches up to 630 Sq mm 3/3.5 core cable with the help of electronic fault locating machine/FLC comprising of surge generator pulse/CFC /ECHO fault locator high pressure resistance and distance calculation for faults exposing the fault, removal of deteriorated portion and for cable joint complete all as specified and as directed. |
| 33 | M&L for disconnecting worn out cable of up to 630 Sqmm size from main control panel cutting worn-out portion and reconnecting with control panel with suitable size of thimbles by incl excavation of earth work for taking out cables from loop complete all as specified and directed. |
| 34 | M & L for Air termination of Lighting conductors, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed . |
| 35 | M & L for Air termination, single pointed, copper rod 12mm dia and 300mm long complete all as specified and directed . |
| 36 | M&L for test point terminal block in replacement made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex.head screw complete all as specified and directed by Engineer-in-Charge. |
| 37 | Supply and fix in replacement of aluminium strip of size 25x3.15 mm for Earth continuity conductor or main earthing lead fixed to wall/ roof with saddles and fixing screws etc. for roof conductors and down conductors above ground or any other indicated situation complete all as specified and directed. |
| 38 | Supply and fix GI strip of size 32x6 mm for Earth continuity conductor or main earthing lead fixed wall with saddles and fixing screws etc. or laid underground as in grid connection of earthing complete all as specified and directed. |
| 39 | M&L for preparation of old steel painted surfaces of LT panels of any type and size by brushing/changing stain, greasy spots with thinner and apply two coats of spray painting with super enameled paint with colour of users choice approved by Dept. and writing the distribution area/location with white paint as directed to transformer indoor/outdoor installed at various different locations complete all as specified and directed at site. |
| 40 | M&L for carrying out horizontal boring below roads/PCC hard standing/Drains all as specified as directed for inserting GI pipe of the following size with a depth upto 1.5m & length of road upto 3 m of the suitable for 40 & 80 mm dia GI pipe as required complete all as specified and directed. |
| 41 | Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide & not exc 1.5 mtr deep and getting out for taking out/laying cable, poles & stay etc complete all as specified and directed by engr-in-charge. |
| 42 | Returning, filling in including spreading levelling watering and well ramming in layers not exceeding 25cm thick after the cable have been laid and tested complete all as specified and directed by Engr-in-Charge.. |
| 43 | Removal of excavated surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engr-in-Charge. |
| 44 | M & L for dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying ( total 23 cm ) and compaction till 18 cm thick for measurement purpose complete all as specified and directed . |
| 45 | Material labour for common burnt clay bricks, sub class 'B' grade laid in trenches for protection of UG cables perpendicular to the direction of the cables complete all as specified and as directed by Engr-in-Charge |
| 46 | Supply, install, test and commissioning of LT feeder pillar board in replacement of out door type made out of 3.15 mm CRCA Sheet CPRI tested cubical type totally enclosed wheather dust and vermin proof with front and rear opening of 415 Volts 3 phase 4 wire 50 Hz having 4 pole aluminium bus bar capacity 600 Amps respectively for different incomings and outgoings insulated with heat shrinkable sleeves RYB and supported on SMC/DMC insulator including internal wiring with FRLS copper wire powder coated including connecting all in coming and out going cable feeders with necessary lugs ferrules etc .The panel should have angle iron support of size 50x50x6 mm with 4 legs of 750 mm long (300 mm grouted in PCC and 450 mm above GL) on the base all around including PCC foundation support , well finishing with cement mortar.Comprising of the following switchgear and accessories are as under:-Make- Legrand/ABB/L&T (a) Mains Incomming : (i) MCCB 400 Amps 4 Pole 36 KA -01 No(Main)(b) Outgoing :(i) MCCB 160 Amps 4pole 25 KA- 01 Nos, (ii) MCCB 125 Amps 4 pole 16 KA -08 Nos,(iii) MCB TPN 16 Amps 10 KA -02 No. ( one spare)(iv) Digital type Multifunctional meter to measure Amp,Voltage-01 No(v) LED Indicating lamp with inbuilt selector switch - 01 set of three |
| 47 | Supply, install, test and commissioning of LT feeder pillar board in replacement of out door type made out of 3.15 mm CRCA Sheet CPRI tested cubical type totally enclosed wheather dust and vermin proof with front and rear opening of 415 Volts 3 phase 4 wire 50 Hz having 4 pole aluminium bus bar capacity 250 Amps respectively for different incomings and outgoings insulated with heat shrinkable sleeves RYB and supported on SMC/DMC insulator including internal wiring with FRLS copper wire powder coated including connecting all in coming and out going cable feeders with necessary lugs ferrules etc .The panel should have angle iron support of size 50x50x6 mm with 4 legs of 750 mm long (300 mm grouted in PCC and 450 mm above GL) on the base all around including PCC foundation support , well finishing with cement mortar.Comprising of the following switchgear and accessories are as under:-Make- Legrand/ABB/L&T (a) Mains Incomming : (i) MCCB 160 Amps 4 pole 25 KA- 01 Nos (b) Outgoing :(i) MCCB 100 Amps 4 pole 16 KA -04 Nos,(ii) MCB TPN 16 Amps 10 KA -02 No. ( one spare)(iii) Digital type Multifunctional meter to measure Amp,Voltage-01 No(iv) LED Indicating lamp with inbuilt selector switch - 01 set of three |
| 48 | Supply, install, test and commissioning of LT feeder pillar board in replacement of out door type made out of 3.15 mm CRCA Sheet CPRI tested cubical type totally enclosed wheather dust and vermin proof with front and rear opening of 415 Volts 3 phase 4 wire 50 Hz having 4 pole aluminium bus bar capacity 250 Amps respectively for different incomings and outgoings insulated with heat shrinkable sleeves RYB and supported on SMC/DMC insulator including internal wiring with FRLS copper wire powder coated including connecting all in coming and out going cable feeders with necessary lugs ferrules etc .The panel should have angle iron support of size 50x50x6 mm with 4 legs of 750 mm long (300 mm grouted in PCC and 450 mm above GL) on the base all around including PCC foundation support , well finishing with cement mortar.Comprising of the following switchgear and accessories are as under:-Make- Legrand/ABB/L&T (a) Mains Incomming : (i) MCCB 250 Amps 4 pole 25 KA- 01 Nos (b) Outgoing :(i) MCCB 125 Amps 4 pole 16 KA -03 Nos,(ii) MCB TPN 16 Amps 10 KA -02 No. ( one spare)(iii) Digital type Multifunctional meter to measure Amp,Voltage-01 No(iv) LED Indicating lamp with inbuilt selector switch - 01 set of three |
| 49 | Supply, install, test and commissioning of LT feeder pillar board in replacement of out door type made out of 3.15 mm CRCA Sheet CPRI tested cubical type totally enclosed wheather dust and vermin proof with front and rear opening of 415 Volts 3 phase 4 wire 50 Hz having 4 pole aluminium bus bar capacity 800 Amps respectively for different incomings and outgoings insulated with heat shrinkable sleeves RYB and supported on SMC/DMC insulator including internal wiring with FRLS copper wire powder coated including connecting all in coming and out going cable feeders with necessary lugs ferrules etc .The panel should have angle iron support of size 50x50x6 mm with 4 legs of 750 mm long (300 mm grouted in PCC and 450 mm above GL) on the base all around including PCC foundation support , well finishing with cement mortar.Comprising of the following switchgear and accessories are as under:-Make- Legrand/ABB/L&T (a) Mains Incomming : (i) MCCB 400 Amps 4 pole 26 KA- 01 Nos (b) Outgoing :(i) MCCB 160 Amps 4 pole 25 KA -02 Nos,(ii) MCCB 200 Amps 4 pole 25 KA -02 Nos,(iii) Digital type Multifunctional meter to measure Amp,Voltage-01 No(iv) LED Indicating lamp with inbuilt selector switch - 01 set of three |
| 50 | Supply, install, test and commissioning of LT feeder pillar board in replacement of out door type made out of 3.15 mm CRCA Sheet CPRI tested cubical type totally enclosed wheather dust and vermin proof with front and rear opening of 415 Volts 3 phase 4 wire 50 Hz having 4 pole aluminium bus bar capacity 400 Amps respectively for different incomings and outgoings insulated with heat shrinkable sleeves RYB and supported on SMC/DMC insulator including internal wiring with FRLS copper wire powder coated including connecting all in coming and out going cable feeders with necessary lugs ferrules etc .The panel should have angle iron support of size 50x50x6 mm with 4 legs of 750 mm long (300 mm grouted in PCC and 450 mm above GL) on the base all around including PCC foundation support , well finishing with cement mortar.Comprising of the following switchgear and accessories are as under:-Make- Legrand/ABB/L&T (a) Mains Incomming : (i) MCCB 200 Amps 4 pole 26 KA- 01 Nos (b) Outgoing :(i) MCCB 100 Amps 4 pole 25 KA -02 Nos,(ii) MCCB 63 Amps 4 pole 25 KA -02 Nos,(iii) Digital type Multifunctional meter to measure Amp,Voltage-01 No(iv) LED Indicating lamp with inbuilt selector switch - 01 set of three |
| 51 | Note for item no 50- (i) All MCCB shall be with adjustable Thermal magnetic setting (TMD).and shall be of same make of panel (ii) The board shall be epoxy polyster powder coated with structure siemens gray shade RAL-7035(iii) Sheet metal works shall be processed with nine tank process i.e. degreasing, water rinsing, activation, derusting, water rinsing, phosphating, water rinsing, passivation and water drying.(iv)Busbar shall be of electrolytic grade aluminium and shall be insulated with Red, Yellow, Blue and black colour heat shrinkable PVC sleeves.(v) Earth bus shall run throughout the length of the panel at the bottom of the panel.(vi) Each feeder shall be provided with individual inscription plate made out of black anodized Al/polycarbonate sheet with engraved/painted letters. (vii)Power switches/MCCB's will be provided with door operating mechanism, door interlock and padlocking feature.(viii ) Danger notice board with conventional skull & bone sign in postman red to be provided on front & rare side.(ix) All incoming & outgoing feeder shall be provided with cable glands at entry & exit of cable. |
| 52 | Maintenance / repairs to APFC panels, 3 phase AC 415 V, by skilled technician and replacement of unserviceable spares as specified below for capacities 60 to 100 KVAR including replacement of short circuited copper conductor cables with appropriate gauge PVC insulated stranded copper conductor cables and cleaning of all moving contacts of relay contactors, tightening of all terminals and testing afer repairs to ensure serviceability and corrected output at specified power factor all as specified and directed at site. |
| 53 | Material Labour And T&P for tree pruning near LT pole for clearing the conductor/light fitting by means of ladder/hydra as per directed location complete all as specified and directed. |
| 54 | Supply and installation in replecement of Hot dipped Octagonal galvanized iron pole 8 mtr height, SMC/DMC Insulator and busbar for three phase a cable connection and MCB SP 6 Amp duly enclosed in pole with cover and cover shall be connected with metal chain, nut bolt for its proper sealing with necessary Foundation RCC 1:1:5:3 with 8Nos.16 mm dia tor bar as main bars and 8mm dia.Tor bars strips@190mm c/c as this reinforcement shall confirm to IS : 1786 latest edition.The foundation shall extend above surroundings ground/drive way level for 200 mm and have DWC 63 mm dia,PVC sleeve cast foundation for cable entry,Excavation,RCC and reinforcement etc as per manufacturer recommendation and the cost of necessary foundation , steel bars , strip and pole top mounted bracket (single or double as per site requirement and directed ) as per Manufacturer instructions complete all as specified and as directed by Engr-in-charge. |
| 55 | Taking Down old US PCC/MS pole from site by means of Hydra including complete base including excavation and other connected items complete all as specified and directed. |
| 56 | S&F in replacement of PVC SMC boxes with hinged door fixing of size 333 mm x233mm x120 mm with MS clamp made to shape with necessery nut bolts and washers complete comprising of Aluminium busbar 63 Amps capacity of suitable size mounted over porcelain insulator withMS clamp nut bolts & washers incl MCB 6 Amps and making incoming and outgoing connections by taking out loops of cable of any size incl necessary excavations and other civil works all as specified and directed. |
| 57 | S&F in Rep/Replacement of cable PVC insulated unarmored for connection 2.5 Sqmm 3 core copper conductor duly drawn from junction box to street light fitting on poles in heavy duty rigid PVC conduit pipes complete all as specified and directed. MAKE- 1. Havells 2.phinolex 3.wipro |
| 58 | Supply and fixing in rerplacement LED type street light 35 watt 230 watt volts AC outdoor type with IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complete all as specified and directed.. |
| 59 | Supply and fixing in replacement LED type street light 90 watt 230 watt volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed.. |
| 60 | Supply and fixing in replacement LED type flood light 120 watt 230 watt volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complete all as specified and directed.. |
| 61 | Supply and fixing in replacement post top lantern LED type 36/40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 class protection with aluminium die cast housing cum heat sink circular canopy and clear acrylic cover for 360 degree indirect uniform glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total system lumen not less than 3200 lumens lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours including gountong of light grade pipe of suitable length on post complete all as specified and directed.. Please Enable Macros to View BoQ information |
| 62 | Supply and fixing in replacement post top lantern LED type 36/40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 class protection with aluminium die cast housing cum heat sink circular canopy and clear acrylic cover for 360 degree indirect uniform glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total system lumen not less than 3200 lumens lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours including gountong of light grade pipe of suitable length on post complete all as specified and directed.. Please Enable Macros to View BoQ information |