| 1 | Excavation in trenches in any type of soil n.exc 1.5m wide and n.exc 1.5m depth in foundations etc for manholes, sewage line and and getting out complete all as specifed and directed. |
| 2 | Excavating over areas in Soft/loose soil n. exc. 1.5mtr deep and getting out complete all as specifed and directed. |
| 3 | Excavating over areas in Soft/loose soil exc. 1.5mtr deep and n. exc 3.00 mtr deep getting out complete all as specifed and directed. |
| 4 | Returning filling in (soil) including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any type of soil complete all as specifed and direct. |
| 5 | Removal of excavated material (soil) to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specifed and direct. |
| 6 | Demolition of brick work or stone/ boulder masonary , bult in cement mortor incl all quoins, arches, pillars etc., including depositing unservicable brick and stacking for re-use including cleaning of bricks and deposting off all debries & rubbish off permises to a distance not exceeding 100 mtr complete all as specifed and direct. |
| 7 | Material and labour Pre-cast cement concrete block masonry type C1, 1:3:6 using 20mm stone aggreage with solid blocks, exc. 10 cm in width and setting in mortar in CM 1:4, complete all specified and direct. |
| 8 | All as per srl item No 7 above here-in-before specifed but except block masonry and direct. |
| 9 | Demolition of cement concrete as in bed to drain pipe 150mm dia including packing under and haunching against the sides of pipe or as in manhole benching/bed etc. Complete all as specified and direct. |
| 10 | Demolition of cement concrete as in bed to drain pipe 200mm dia including packing under and haunching against the sides of pipe or as in manhole benching/bed etc. Complete all as specified and direct. |
| 11 | Demolition of cement concrete as in bed to drain pipe 300mm dia including packing under and haunching against the sides of pipe or as in manhole benching/bed etc. Complete all as specified and direct. |
| 12 | M&L for Cutting into existing manholes/new Concrete wall for connecting new drains, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cemnt concrete 1:2:4 type B-1 smooth finished and forming benching as required. Internal dia of pipe 150mm complete all as specified and direct. |
| 13 | Material and labour for PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate in bedding to DWCPE drain pipes, including packing under and haunching against the sides of pipes after they are laid and tested complete for 150 mm bore pipe all as specified and as directed |
| 14 | All same as per item No 13 here-in-above but for 200 mm bore pipe -do- complete all as specified and directe |
| 15 | All same as per item No 13 here-in-above but for 300 mm bore pipe -do- complete all as specified and directed |
| 16 | M & L for DWCPE(SN4) pipes nominal dia 172.50 (OD)/148.50(ID) mm diameter Pipes) laid on any depth of trenches including jointing/cutting as required length pipes with jointing with socket/spigoht with elastomeric sealing as per manufactutrers instruction to make the sewer line functional including testing on completion to entrire satisfaction of Engr-in-Charge complete all as specified and directed |
| 17 | All as per srl item No-16 here-in-before specifed but 198.50 (ID) mm dia complete all as specified and directed |
| 18 | All as per srl item No-16 here-in-before specifed but 298.50 (ID) mm dia complete all as specified and directed |
| 19 | Demolition of cement concrete (unreinforced) as in floors and paving n exc 15cm thickness (below or above ground level) including deposal off rubbish to a distance not exc 100 mtr all as specified and directed. |
| 20 | Material and labour Cement concrete 1:4:8 type D-2 (using 40mm graded aggregate) in foundation filling and mass concrete and directed. |
| 21 | Demolition of Reinforced precast cement concrete manhole cover slab of any description and in any position including and segregation of reinforcement complete all as specified and as directed |
| 22 | M & L for Precast reinforced cement concrete type B-1, 1:2:4 (20mm graded) aggregate as in manhole cover all as specifed including form work complete all as specified and directed |
| 23 | M&L for cement concrete 1:2:4 type B1 using 20mm graded aggregate as in benching, bed plates, coping and the like including weathering, slightly rounded or chamfered angles as directed including formwork and finishing all exposed surfaces complete all as specified and directed |
| 24 | Supply and fixing TMT steel bars 8mm or 10mm dia in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia all as specified and directed. |
| 25 | S & F PVC (SWR) 75 mm dia floor trap, plain with grating including jointing with solvent cement complete all as specified and directed |
| 26 | M & L for 75mm PVC (SWR) multi floor trap with grating including jointing with solvent cement complete all as specified and directed |
| 27 | M & L for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed. |
| 28 | M&L Cast iron work grade FG 150, unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles n. exc 5Kg Each complete all as specified and directed. |
| 29 | Taking down cement plaster of any description on brick or block wall ceiling and concrete surface etc including rackimg out joints,hacking for keys all as specifed and as directed by Engineer-in- Charge. |
| 30 | Material and labour Rendering 15mm thick on brick or block masonry surfaces in cement mortar 1:4 finished even and smooth without using extra cement with WPC complete all as specified and directed.Note: WPC shall be measured and paid separately under respective item. |
| 31 | Supply only integral water proofing compound complete all as specified and directed |
| 32 | Demolition of cement concrete (unreinforced) of any description and in any position (sunken floor) not otherwise specifically provided for and disposing the debris out side defence land , complete all as specified and directed. |
| 33 | M & L Type E2 1:5:10 (using 40 mm size graded stone aggregates ) Cement concrete in foundations, filling and mass concrete in sunken floors complete all as specified and directed. |
| 34 | M&L for Vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests including PVC SWR P trap connecting to flush pipe and to anti syphonage pipe, etc. complete including making good to floor., fixed in repairs complete all as specified and directed. |
| 35 | M&L for PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, connections to pipes and fixing of chain and pull, or lever, fixed in repairs complete all as specified and directed. |
| 36 | S & F in repairs Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including PVC SWR P/S trap connecting to flush pipe and to anti syphonage pipe, flushing cistern of capacity 10 liters, low level, white, with inlet, ball valve, float and handle including bracketsetc. complete including making good to floor, fixed in repairs complete all as specified and directed.Note Flushing cistern will be measured and paid separately |
| 37 | Demolition of drain/PVC pipe any dia including fittings complete all as specified and directed. |
| 38 | S&F 110mm bore PVC (SWR) Pipes single socketed in any length with rubber ring fixed to walls complete all as specified and directed. |
| 39 | S&F 110mm bore PVC (SWR) Pipes single socketed in any length with rubber ring joints, laid in floors complete all as specified and directed. |
| 40 | S&F 75mm bore PVC (SWR) Pipes single socketed in any length with rubber ring joints, laid in floors complete all as specified and directed. |
| 41 | S&F 75mm bore PVC (SWR) Pipes single socketed in any length with rubber ring fixed in wall complete all as specified and directed. |
| 42 | S & F PVC (SWR) T Junction of 110mm bore, single equal or unequal with accesss door complete all as specified and directed. |
| 43 | M&L for 25 mm thick cement concrete 1:2:4, type B-1 using 20 mm graded aggregate as in sub base to receive floor finishes complete all as specified and directed. |
| 44 | M&L Non - skid ceramic coloured tiles of 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick Screed bed in CM 1:4, complete all as specified and directed. |
| 45 | M&L for Form work to Sides of soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, roof slabs etc.also splays between floors and beams complete all as specified and directed |
| 46 | M&L for Form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n. exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n. exc 20cm wide for rough finished surfaces of concrete complete all as specified and directed. |
| 47 | S & F for precast RCC Collar rings NP3 300mm dia, 50mm thick each ring height of minimum 0.30m maximum 0.45m having weep holes from the side of the ring laying in excavated trenches of any depth complete all as specified and directedNote : Excavation and filling measured and paid separately |
| 48 | Removal of materials (debris taken out of either demolished)out of the MD land to the dumping yard of any distance (exc 1.00 km) complete all as specified and directed.Note : one metric tonne shall be considered as 01 load. Please Enable Macros to View BoQ information |