| 1 | Taking down carefully any type point wiring (light, fan, socket or power) complete including conduits/casing- capping with fittings such as light fittings, sockets, switches ceiling roses, board outlets etc and removing the materials/ debris and making good the disturbed surfaces of walls, floor etc to match with the existing surface, complete all as specified and as directed. |
| 2 | M&L Point wiring complete with FRLS 1100 Volts grade, 1.5 Sqmm PVC insulated and unsheathed copper conductor single core cable drawn through and including 25 mm medium grade ISI marked PVC casing caping with all accessories such as bends, elbow, reducers , junction boxes /MS boxes duly painted /PVC box factory made ractangular in shape as required with top cover 3 mm thick plastic laminated sheets of required size, fixed with screws, for housing switches, sockets, regulators etc, including 1.5 sqmm PVC insulated and unsheathed copper conductor cable as earth continuity wire connected to common earth dolly all as specified and as directed, for the following :- |
| 3 | (a) Description all as item no.02 above but for One light point controlled by one switch. |
| 4 | (b) Description all as item no.02 above but for One switch socket combination 5 Amps on independent board. |
| 5 | (c) Description all as item no.02 above but for One switch socket outlet 5 Amps on same board with other switches. |
| 6 | M&L for point wiring in non-metallic PVC casing & caping including all fitting with 2.5 Sq mm size multi stranded FRLS copper conductor cable including clamps, screws gutti /plug etc PVC unsheathed cable into and including wooden board/sheet steel box of 1.6mm thick with bakelite sheet 3mm thick and PVC insulated fire retardant cable of size 2.5 Sq mm as earth continuity conductor, complete all as specified and as directed. |
| 7 | S & F fixed in repair Switch piano flush type single pole, one way 5/6 Amp, complete all as specified and as directed. |
| 8 | S&F in repair Switch socket combination box type multipurpose 2/3 pin suitable for 5 Amp plug top controlled by one switch, complete all as specified and as directed. |
| 9 | S & F in repair switch socket outlet two in 1 3 Pin, 5 Amp, 230 Volts, complete all as specified and as directed. |
| 10 | S&F in repair Switch socket combination flush type multipurpose 3/5 pin suitable for 15 Amp, complete all as specified and as directed. |
| 11 | S&F in repair Ceiling rose surface bakelite surface 65x50 mm 3 trminals fixed on wall/ceiling and including PVC block, complete all as specified and as directed. |
| 12 | Supply and fixing LED lights fitting 1X20 Watt , 4 Feet 220 Volt AC decorative box type with driver,holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed. |
| 13 | Supply and fixing LED lights fitting 1X10 Watt, 2 Feet 220 Volt AC decorative box type with driver,holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed. |
| 14 | S&F LED Lamp 9 W 'T' type, complete all as specified and as directed. |
| 15 | S&F in repair Lamp holder/angle batten, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings, complete all as specified and as directed. |
| 16 | S&F MCB DB 12 way sheet metal enclosure SPN 240 volts, 50 Hz, with IP-42 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting, complete all as specified and as directed. |
| 17 | S&F MCB DB 8 way sheet metal enclosure SPN 240 volts, 50 Hz, with IP-42 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting, complete all as specified and as directed. |
| 18 | S&F MCB DB 4 way sheet metal enclosure SPN 240 volts, 50 Hz, with IP-42 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting, complete all as specified and as directed. |
| 19 | S & F MCB DP, 240 Volts, AC, B curve, 10 KA, 40 Amps (10 KA 'B' rupturing capacity), complete all as specified and as directed. |
| 20 | S & F MCB single pole, 240 Volts, AC, B curve, 10 KA, 6 to 32 Amps (10 KA 'B' rupturing capacity) complete all as specified and as directed |
| 21 | Supplying Only PVC flat twin core cable PVC insulated aluminium conductor size 4 sqmm 2 core. |
| 22 | Supplying Only PVC flat twin core cable PVC insulated aluminium conductor size 6 sqmm 2 core. |
| 23 | Supplying Only PVC flat twin core cable PVC insulated aluminium conductor size 10 sqmm 2 core. |
| 24 | Supplying Only flat twin core cable PVC insulated aluminium conductor size 16 sqmmm 2 core. |
| 25 | S & F in repair Sub main wiring using two runs of single core PVC insulated cable with copper conductor multistranded 1100 volts of sizes 6.0 Sqmm through existing/ new non metalic PVC casing capping including copper earth wire in green colour of size 6.0 Sqmm connection to DB with thimbling complete as specified and directed. (Note:- Two runs of sub main wire including earth wire and rigid non metalic PVC casing capping shall be measured as one unit per RM make of cable. |
| 26 | Earthing complete with galvanised steel earth plate, electrode, 600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) connected to galvanised earth lead wire 4.0mm dia by means of nuts, bolts, & washers of GI as shown in electrical plate No. 5 of SSR Part-I. Connected to earthing test point all as specified and including necessary earth pit PCC 1:3:6 chamber be 50mm thick PCC 1:2:4 chamber cover with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover, watering arrangement shall be made with GI pipe medium grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 15mm dia upto 7.5 from the earth plate electrode & refillling of soil etc including necessary excavation & earth work in any strata and PCC chamber complete all as specified and directed by Engr-in-Charge including demolish existing earth pit taking out old materials. |
| 27 | Supply only following items complete all as directed by Engr-in-Charge. |
| 28 | (a) Switch piano 5 Amp |
| 29 | (b) Switch piano 15/16 Amp |
| 30 | (c) Angle/ Batten holder |
| 31 | (d) 5 Amps switch socket combination 3/5 pin type along with box. |
| 32 | (e) 15 Amps switch socket combination 3/5 pin type along with box. |
| 33 | (f) Modular switch flush type one way 6 Amp, 230 volts |
| 34 | (g) Modular switch flush type one way 16 Amp, 230 volts |
| 35 | (h) Modular socket 6 Amp 2/3 pin combined 2 module |
| 36 | (i) Modular socket 6 /16 Amp 2/3 pin combined 2 module |
| 37 | (j) Top plug 5 Amp socket complete |
| 38 | (k) Top plug 15 Amp socket complete |
| 39 | (l) Change over 32 Amp socket complete |
| 40 | (j) Insulation tape of size 32/40mm of Red, Yellow, Blue and Black colour |
| 41 | (k) PVC Casing and caping complete all as specified |
| 42 | (l) PVC Conduit pipe 20mm complete all as specified |
| 43 | (m) Supply Only SMD LED panel recess/surface suspended mounting 36 watt 2' x 2' LED ceiling light with extruded aluminium housing and milky diffuser including connecting up with twin core twisted flexible copper conductor cable with suitable size of 170-230 Volts, 50HZ Make:- Havells cat part no.VENUSNEOHE2X2PLR18-42WLED830MOD |
| 44 | (n) Supply Only round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete. Make:- Havells cat part no.EDGEPRORDDLR12WLED857S |
| 45 | (o) Supply Only Wall mounted Fan 400 mm sweep, complete all as specified and as directed. |
| 46 | (q) Supply only 1.5 sqmm cable FRLSH insulated industrial cables , complete all as specified and as directed. |
| 47 | (r) Supply only 2.5 sqmm cable FRLSH insulated industrial cables, complete all as specified and as directed. |
| 48 | (s) MCB single pole 6 Amp, complete all as specified and as directed. |
| 49 | (t) MCB single pole 10 Amp, complete all as specified and as directed. |
| 50 | (w) MCB single pole 16 Amp, complete all as specified and as directed. |
| 51 | (x) MCB single pole 20 Amp, complete all as specified and as directed. |
| 52 | (y)MCB single pole 32 Amp, complete all as specified and as directed. |
| 53 | (z)MCB double pole 40 Amp, complete all as specified and as directed. |
| 54 | (aa) MCB Double pole 63 Amp, complete all as specified and as directed. |
| 55 | (ab) Supply only LED lights fitting 1X20 Watt , 4 Feet 220 Volt AC decorative box type with driver,holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed. |
| 56 | (ac) Supply only LED Lamp 9 W 'T' type, complete all as specified and as directed. |
| 57 | (ad) Supply only LED Lamp 20 W 'T' type, complete all as specified and as directed. |
| 58 | (ae)Supply only Garden light Unique concept LED Bollard in IP 66 to ensure sustainable performance in all sections and aesthetics which keeps the surrounding lively Cat part No:- TURINBLS10WLED830PSYMTOPC, complete all as specified and as directed. |
| 59 | (af)Supply only Decorative light wall mounting, brushed nickel finish fixture with Opal Glass diffuser suitable with 9 W LED lamp B22 base.Cat part No:-LHFOAJE1TZ1I060, complete all as specified and as directed. |
| 60 | (af)Supply only LED strip light High brightness IP65 LED strips with uniformity of light required for perfect outdoor application Model:Flexion AC Rope 144DStrip 3000/4000/6000 K IP65 50 M (50-50 Mtr -02 roll), complete all as specified and as directed. |
| 61 | Supply only Track light bed side decorative type, complete all as specified and as directed. |
| 62 | Supply Only heating element (round/traingular) including rubber gasket & washer etc of capacity 1.5 KW suitable for existing make and shape, complete all as specified and as directed. |
| 63 | Supply Only heating element (round/traingular) including rubber gasket & washer etc of capacity 2 KW suitable for existing make and shape, complete all as specified and as directed. |
| 64 | Supply only Thermostate including rubber / PVC gasket to be set to a temperature not higher than the range of 70 degree Centigrade suitable for existing geysers of capacity 25 / 35 / 50 ltrs including taking down existing unserviceable thermostate, complete all as specified and as directed. |
| 65 | Supply only high pressure valve with dead weight suitable for 25 / 50 ltrs capacity Geysers including taking down existing unserviceable high pressure valve, complete all as specified and as directed. |
| 66 | Supply only PVC connecting pipe 18\\" long with brass adopters for cold water and connecting up with complete for 25 /35 / 50 ltrs capacity Geysers including taking down existing unserviceable PVC connecting pipe, complete all as specified and as directed. |
| 67 | Supply only PVC connecting pipe 18\\" long with brass adopters for hot water and connecting up with complete for 25 /35 / 50 ltrs capacity Geysers including taking down existing unserviceable PVC connecting pipe, complete all as specified and as directed. |
| 68 | S&F exhaust fan/brisk air fan of size 380 mm sweep, Steel body, complete all as specified and as directed. |
| 69 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm, complete all as specified and as directed. |
| 70 | Note:- Schedule of credit Rs 1,74,628.00 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents. Please Enable Macros to View BoQ information |