| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE Utilities Udhampur Name of Work: Provision of certain Minor works at various locations in the AOR of E/S and RAC Sub Div under GE (Utilities) Udhampur Contract No: GE/U-98/2025-26 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 Sqmm nominal cross section inservice connections:- (Note : Excavation, earthwork, Pipe for cable protection to be measured and paid for separately), complete all as specified and directed by Engineer-in-Charge. |
| 3 | (a) 6 Sqmm 3 Core |
| 4 | S&F in replacement of sub main wiring with copper conductor cable (2 runs of cable) multistaranded 4.0 Sqmm PVC ISI marked with all insulated unsheathed in and including PVC concealed conduit 25 mm dia medium grade fittings including 4.0 Sqmm copper conductor cable PVC insulated unsheathed multithreaded using as continues earth wire connected to common earth and earth dolly, complete all as specified and directed by Engineer-in-Charge. |
| 5 | M & L for providing earthing with GI earth plate electrode 600 X 600 X 6mm buried directly in ground (earth pit not less than 2.25M deep below ground level ) with top edge of the earth plate not less than 1.5M below ground level connected to GI strip 25 x 4 mm thick for earthing lead fixed by means of nuts,bolt,washers etc connected to earth test point complete all as specified in electrical plate NO 3 of SSR1996 part 1 ,including necessary excavation and earth work in any strata of soil,comman salt, charcoal dust, 40 mm dia light grade GI pipe for protection to earth lead, GI water pipe 20mm dia with funnel &wire mesh , PCC pit with CI cover and frame etc all as specified and directed by Engineer-in-charge. Note:- All the joints shall be made with welding to get proper conductivity.On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost, complete all as specified and directed by Engineer-in-Charge. Note:- The Contractor shall fix the Earth Pit Chamber Board of 3.15 mm thick mild steel sheet of size min 45 cm X 30 cm fixed with 12 mm thick MS rod two nos up to 90 cm Height by nut/bolts including spray painting with two coats of synthetic Enamel Black Paint complete MS Sheet both side including writing letters min 6 cm height i.e. Earth Pit No. , Location, Earthing test value and date and other letters, complete all as specified and directed by Engineer-in-Charge. |
| 6 | S&F of LED bollard warm white with robust design and efficient garden lights of 9/10 watt capacity, IP65 protection and flared/trumpet-shaped diffuser head for uniform light distribution with minimum height oflight should be 800 mm from base including internal wiring, terminal connectors, mounting flange and hardware, complete all as specified and directed by Engineer-in-Charge. Make:- Crompton Cat No LBLSN-10-WW or equivalent make in PS.Note:-Each light shall be marked or embossed as GE (U) Udhampur with CA No. |
| 7 | Plain cement concrete, M-15, type B-0 (using 20 mm graded crushed stone aggregates) as in Foundation/coping/ Road or Floor Covering for Post Top & Bollard Lights, complete all as specified and directed by Engineer-in-Charge. |
| 8 | Supply and fix LED warm white Post Top light fitting 40 watts, IP66, Energy Saving LED light with PDC , Aluminium body & secondary Optical lens for superior light distrubution , Efficacy > 110 Lm/W. 5700K , complete all as specified and directed by Engineer-in-Charge. Make :Crompton Cat PArt No. CBP-610-40-57-SL-CA-NBK,or equivalent make in PS. |
| 9 | S&F double walled corrugated (DWC) pipe of size 50mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of LT cable in under ground,complete all as specified and directed by Engineer-in-Charge. Make: REX/Tirupati Plastomatics Pvt Ltd |
| 10 | Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil, complete all as specified and directed by Engineer-in-charge. |
| 11 | Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick, complete all as specified and directed by Engineer-in-charge. |
| 12 | Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed by Engineer-in-charge. |
| 13 | Terminal box made out of SMC with hinged door and locking arrangements of size 140x140x95mm including Backlite 4 way connector,M.S. Clamps suitable for pole ,PCC/MS/GI/rail etc. with bolt, nut and washer ,electrical connections including MCB SP 6-32 Amps, complete all as specified and directed by Engineer-in-charge. |
| 14 | Supply & fixing of Nature Switch Smart Timer based Automatic Street Light Control Panel. The Panel should be suitable enough to take Single-Phase load of 3kW with: Contactor, Incoming MCB 1 No & Outgoing MCB 05 Nos rating of 16-20 Amps & main load Circuit Wiring (Copper) of min. 6 sq.mm Nature Switch Smart Timer should be maintenance-free in design and settings accessible via a Mobile App (with Bluetooth connectivity). The Mobile App should allow users to customize the ON & OFF timings based on Natural Light (sensor), Local Sunset/Sunrise (Astro) and Time. The Mobile App should also have facility to set Input Voltage range.The Smart Timer along with suitable Power Contactor(s) and Incoming-Outgoing MCBs should beenclosed in a pole/wall mountable Rust Proof, Electric Shock Proof, Termite proof and FR grade SMC Enclosure conforming to IP66. The circuit should also have provision for Manual Operation (i.e. Sensor By-Pass option), complete all as specified and directed by Engineer-in-Charge. Make: L&T / Schneider / Siemens / Healer Enterprises (Navdeep-66-3kW1P). |
| 15 | LED Flood light, 150 watt, 230 V, AC outdoor type with thermal management in multiple optics, powder coated, pressure die cast aluminium body with toughened glass visor, and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp,CCT 5700K, lumen efficacy not less than 110 lumen/watts, complete all as specified and directed by Engineer-in-Charge.Make-(Crompton Cat Part No. TFS-504-150-57-60D-HL2-GL-NBK |
| 16 | S & F LED Strip Light of 10-meter length, IP65 protection, input power 10 W/m, input voltage 220–240 VAC, input frequency 50 Hz, input current 0.045 A/m, power factor 0.95, strip width 8 mm (±0.1 mm), length per reel 18 m, 120 LEDs per meter, LED beam angle 120°. Rope light colour as required at site. Fixing using silicone clips. IP protection provided through silicone tube of size 11.5 × 5.5 mm (±0.5 mm). Working temperature: –20°C to +45°C, humidity: 10–90% RH, complete all as specified and directed by Engineer-in-charge. |
| 17 | S & F Joy LED Strings light 10 Mtr 21D IP 44, Input Voltage 220-240 VAC Input frequency 50 Hzs, Input current 0.045 Amp/Mtr, Power factor ss Protection - IP -44, working temp range -20 degree celcius to + 45 degree celcious, working humidity range 10-90 RH and complete all as specified and directed by Engineer-in-charge.Make: Havells Cat No LHEHCJP1UN4K010, & equivalant. |
| 18 | S&F 90 Watt inverter type LED street light with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 100 lumen/Watt (Minimum lumen output of luminarie should be 6000 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. Luminarie should have top maintainable driver compartment for easy access to driver during maintenance. The driver used must be a constant current driver with efficiency of > 85%. Note :- The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report, complete all as specefied and directed by Engineer-in-charge. |
| 19 | Supply, laying, jointing & testing in replacement XLPE insulated, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade cross sectional area 16 Sqmm 4 core laind in trenches or passing through pipe or fixed on poles, complete all as specified and directed by Engineer-in-Charge. |
| 20 | S&F double walled corrugated (DWC) pipe of size 77 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground, complete all as specefied and directed by Engineer-in-charge. Make: REX/Tirupati Plastomatics Pvt Ltd |
| 21 | M&L for cement concreate 1:2:4 type D-2 (using 40 mm graded stone aggregate) as in coping etc including necessary form work and finishing the surface with cement mortar 1:4, 5mm thick finished to the portion of PCC muffs above ground level, complete all as specefied and directed by Engineer-in-charge |
| 22 | M&L for PCC 1:4:8 type D-2 (using 40 mm grade stone aggregrate in foundation, mass concrate) as in foundation of poles & stay etc, complete all as specefied and directed by Engineer-in-charge. |
| 23 | S&F in replacement erecting steel tubular swaged poles erected to truly vertical or planted as strut complete with 6mm thick mild steel base plate(300mmx300mm), welded to pole, finial taper plug, bolts, nuts, and screws poles made out of ERW MS tubing conforming to IS-2713 Part-II Type 410 SP-31, 9mtr long including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bitumenous paint internally and portion embedded in concrete, making five black & white bands at lower portion of pole each 300mm wide alternately upto the height and marking pole No. with black paint at suitable height including making two nos holes of suitable size in steel tubular pole by gas welding for passing PVC cable connection from junction box to security lights through pole where junction box to be fitted in pole, complete all as specefied and directed by Engineer-in-charge. Note: - Excavation and Earth Work, PCC in foundation shall be measured and paid for separately. |
| 24 | S&F MS bracket for street light fittings made out of 40 mm dia GI pipe of medium grade 1.5 mtr long each bent to required shape & size and fixed to pole with and including flat iron clamps 02 Nos made out of 32x6 mm flat iron including GI Nuts, bolts and washers and painting of clamps and street light brackets with two coat of aluminium paint over a coat of red oxide primer and fittings bracket to street light fittings, complete all as specified and directed by Engineer-in-Charge. |
| 25 | S&F modular box made of FRP impact resistance plastic & heat resistant, dust proof, water proof materials of suitable hole for in and out of cable with IP65 incl TPN of 63 Amp suitable for fixing cable connection and fixing to walls with suitable nuts, bolts, complete all as specified and directed by Engineer-in-Charge. Make : Sintex/Hansu |
| 26 | Supply and Fixing LT Junction box cubical type of size 60x40x30 cm, 415 volts for outdoor use made out of CRCA Sheet 3.15 mm thick powder coated, machine passed front opening with sigal door with privision of rubber beading and locking system including aluminium bus bar 4 srip of size 30mm wide and 6mm thick with provision of hole on bus bar fixing of cable mounted on PVC/ epoxy insulators, mounted on angle legs of size 25x25x5mm frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC(1:2:4) Type B-1 (using 20 mm graded stone aggregate) complete including all provision of opening for incomming/Outgoing cables and testing, complete all as specefied and directed by Engineer-in-charge |
| 27 | Supply and installation AC in wall split unit air conditioner reversible type indoor and outdoor unit complete with cordless remote control unit and with built air plasma filter for better inddor air quality of capacity 2 ton with standard accessories including MS frame work for installation of outer with side Make: Volts or equivalent to Carrier/Daiken and making reqd hole in wall for passing of cooling pipes / cable and repair work of demaged portion of wall in CM 1:4, complete all as specefied and directed by Engineer-in-charge |
| 28 | Supply and fix voltage stabilizer for automatic operation single phase naturally air cooled indoor type and disigned for input voltage 130V to300V with output voltage 230V with accuracy of +- 2.5% and capacity 5 KVA, complete all as specified and directed by Engineer-in-Charge. |
| 29 | Supply and fix copper tubing incl brazing and lead testing alongwith foam insulation of any size as reqd for fixing of split AC of capacity 2.0 ton, complete all as specified and directed by Engineer-in-Charge. |
| 30 | S&F Sub main wiring with two single core PVC insulated FRLS unsheathed copper conductor multistranded cable 1100 volts grade 4.0 sqmm size in PVC Conduit heavy duty ISI marked with 4.0 sqmm PVC insulated FRLS copper coductor multistranded cable as earth lead to connecting to earth dolly, complete all as specified and directed by Engineer-in-Charge. |
| 31 | S&F Wiring for connection between outer and inner unit of split AC with four core Cable PVC insulated FRLS unsheathed copper conductor multistranded cable 1100 volts grade 2.5sqmm size in PVC conduit heavy duty ISI marked with 2.5 sqmm PVC insulated FRLS copper conductor cable multistranded as earth lead/single to connecting to earth dolly, complete all as specified and directed by Engineer-in-Charge. |
| 32 | Supply and fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps AC 230Volts 'C' series incl dismantling old one, complete all as specified and directed by Engineer-in-Charge. |
| 33 | Supply and installation AC in wall split unit air conditioner (Hot & Cold) type indoor and outdoor unit complete with cordless remote control unit and with built air plasma filter for better inddor air quality of capacity 1.5 ton with standard accessories including MS frame work for installation of outer with stand side, complete all as specified and directed by Engineer-in-Charge. |
| 34 | Supply and fix copper tubing incl brazing and lead testing alongwith foam insulation of any size as reqd for fixing of split AC of capacity 1.5 ton, complete all as specified and directed by Engineer-in-Charge. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |