Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exc 1.5 mtr wide & not exc 1.5 mtr in depth: for foundationetc or for manholes, laying of pipe in any type of soil and getting out complete all as specified |
| 2 | Excavation in trenches not exc 1.5 mtr wide & exc 1.5 mtr but not exc 3.0 mtr in depth: for foundationetc or for manholes, laying of pipe in any type of soil and getting out complete all as specified |
| 3 | Returning filling in, including spreading, leveling watering & well rammng in layers not exc 25cm thick complete all as specified and directed by EIC |
| 4 | Removing excavated material to a distance not exc 50 mtr & depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified & diected |
| 5 | Demolition of cement concrete (un-reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) and of any description and in any position not otherwise specifically provided for all as specified and directed by Engineer - in - Charge . |
| 6 | M&L Cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate for support to pipe line, foundations, fillings and mass concrete all as specified and directed by Engineer – in - Charge. |
| 7 | Taking up CI/ DI/ MS/ GI pipe (including all fittings) with spigot and socket ends centrifugally cast 150 mm bore laid in trenches complete all as specified and directed by Engineer - in - Charge. |
| 8 | Taking up CI/ DI/ MS/ GI pipe (including all fittings) with spigot and socket ends centrifugally cast 200 mm bore laid in trenches complete all as specified and directed by Engineer - in - Charge. |
| 9 | Supplying, laying, jointing, commissioning and testing of ductile iron pressure pipe with socket & spigot ends having ISI marking confirming to IS:8329/2000 in standard lengths of classification K-9 suitable for and including push on rubber tyton joint (gasket D-jointing) with cement mortar lining in the pipes having 150 mm bore, including aligning the pipes inside trench as per IS:12288/1987 and testing the joints with required water pressure complete all as specified & directed. |
| 10 | Supplying, laying, jointing, commissioning and testing of ductile iron pressure pipe with socket & spigot ends having ISI marking confirming to IS:8329/2000 in standard lengths of classification K-9 suitable for and including push on rubber tyton joint (gasket D-jointing) with cement mortar lining in the pipes having 200 mm bore, including aligning the pipes inside trench as per IS:12288/1987 and testing the joints with required water pressure complete all as specified & directed. |
| 11 | Relaying 150mm bore CI/DI/GI pipes with spogot and sockets ends after cleaning internal surface of serviceable pipes by using of wire brushed and cleaning throughly with fresh water and taking out mud/soft deposited inside the pipes in any length laid in trenches including requir jointing material complete all as specified and directed. |
| 12 | Relaying 200mm bore CI/DI/GI pipes with spogot and sockets ends after cleaning internal surface of serviceable pipes by using of wire brushed and cleaning throughly with fresh water and taking out mud/soft deposited inside the pipes in any length laid in trenches including requir jointing material complete all as specified and directed. |
| 13 | S & F ductile iron pipe fittings such as bends, tapers, tee pieces single branch, \\"Y\\" junction, collars, caps and plugs etc spigot socketed or flanged ends type of size up to 150mm nominal bore conforming to IS-9520/2000 with pressure rating PN-1 (all the fittings shall be coated for rust prevention i.e. external coating zinc rich paint with finishing layer of bituminous as per Annexure - A of IS:9523/2000 and internal lining shall be of cement mortar with seal coat as per Annexure 'B' of IS-9523/2000) complete all as specified and directed by Engineer - in - Charge.Note: (i) Joint and jointing material shall be measured and paid separately. (ii) Excavation and earth work shall be measured and paid for separately. |
| 14 | S & F ductile iron pipe fittings such as bends, tapers, tee pieces single branch, \\"Y\\" junction, collars, caps and plugs etc spigot socketed or flanged ends type of size 200mm to 600mm nominal bore conforming to IS-9520/2000 with pressure rating PN-1 (all the fittings shall be coated for rust prevention i.e. external coating zinc rich paint with finishing layer of bituminous as per Annexure - A of IS:9523/2000 and internal lining shall be of cement mortar with seal coat as per Annexure 'B' of IS-9523/2000) complete all as specified and directed by Engineer - in - Charge.Note: (i) Joint and jointing material shall be measured and paid separately. (ii) Excavation and earth work shall be measured and paid for separately. |
| 15 | Cutting to existing CI/DI/MS pipe line of size 100mm bore required for repair/replacement of pipe line and insertion of collars/tail pieces, tee etc including dewatering of pit if any complete all as specified and directed. Note : Excavation and earth work if any shall be measured and paid for separately. |
| 16 | Cutting to existing CI/DI/MS pipe line of size 150mm bore required for repair/replacement of pipe line and insertion of collars/tail pieces, tee etc including dewatering of pit if any complete all as specified and directed. Note : Excavation and earth work if any shall be measured and paid for separately. |
| 17 | Cutting to existing CI/DI/MS pipe line of size 200mm bore required for repair/replacement of pipe line and insertion of collars/tail pieces, tee etc including dewatering of pit if any complete all as specified and directed. Note : Excavation and earth work if any shall be measured and paid for separately. |
| 18 | Cutting to existing CI/DI/MS pipe line of size 250mm bore required for repair/replacement of pipe line and insertion of collars/tail pieces, tee etc including dewatering of pit if any complete all as specified and directed. Note : Excavation and earth work if any shall be measured and paid for separately. |
| 19 | Cutting to existing CI/DI/MS pipe line of size 300mm bore required for repair/replacement of pipe line and insertion of collars/tail pieces, tee etc including dewatering of pit if any complete all as specified and directed. Note : Excavation and earth work if any shall be measured and paid for separately. |
| 20 | Taking up or down DI/CI/MS/GI pipes 100 mm bore removing from site (including all fittings) with flanged ends complete all as directed. Note: Excavation and earth work shall be measured and paid for separately. |
| 21 | Taking up or down DI/CI/MS/GI pipes 150 mm bore removing from site (including all fittings) with flanged ends complete all as directed. Note: Excavation and earth work shall be measured and paid for separately. |
| 22 | Taking up or down DI/CI/MS/GI pipes 200 mm bore removing from site (including all fittings) with flanged ends complete all as directed. Note: Excavation and earth work shall be measured and paid for separately. |
| 23 | Taking up or down DI/CI/MS/GI pipes 250 mm bore removing from site (including all fittings) with flanged ends complete all as directed. Note: Excavation and earth work shall be measured and paid for separately. |
| 24 | Taking up or down DI/CI/MS/GI pipes 300 mm bore removing from site (including all fittings) with flanged ends complete all as directed. Note: Excavation and earth work shall be measured and paid for separately. |
| 25 | Supplying, fixing, jointing and testing MS black pipe with flanged ends ISI marked, Fe-410 grade as per IS:1239/2004 nominal bore 100 mm, medium grade (Class B) in standard length of 5.50 - 6.00 meter, 6mm thick complete incl jointing materails such as nuts/bolts/washers/rubber gaskets,welding etc all as specified and as directed. Note: (i) MS fittings, MS flanges, Joints shall be measured and paid for separately. (ii) Excavation and earth work shall be measured and paid for separately. |
| 26 | Supplying, fixing, jointing and testing MS black pipe with flanged ends ISI marked, Fe-410 grade as per IS:1239/2004 nominal bore 150 mm, medium grade (Class B) in standard length of 5.50 - 6.00 meter, 6mm thick complete incl jointing materails such as nuts/bolts/washers/rubber gaskets,welding etc all as specified and as directed. Note: (i) MS fittings, MS flanges, Joints shall be measured and paid for separately. (ii) Excavation and earth work shall be measured and paid for separately. |
| 27 | Supplying, fixing, jointing and testing MS black pipe with flanged ends ISI marked, Fe-410 grade as per IS:1239/2004 nominal bore 200 mm, medium grade (Class B) in standard length of 5.50 - 6.00 meter, 6mm thick complete incl jointing materails such as nuts/bolts/washers/rubber gaskets,welding etc all as specified and as directed. Note: (i) MS fittings, MS flanges, Joints shall be measured and paid for separately. (ii) Excavation and earth work shall be measured and paid for separately. |
| 28 | Supplying, fixing, jointing and testing MS black pipe with flanged ends ISI marked, Fe-410 grade as per IS:1239/2004 nominal bore 250 mm, medium grade (Class B) in standard length of 5.50 - 6.00 meter, 6mm thick complete incl jointing materails such as nuts/bolts/washers/rubber gaskets,welding etc all as specified and as directed. Note: (i) MS fittings, MS flanges, Joints shall be measured and paid for separately. (ii) Excavation and earth work shall be measured and paid for separately. |
| 29 | Supplying, fixing, jointing and testing MS black pipe with flanged ends ISI marked, Fe-410 grade as per IS:1239/2004 nominal bore 300 mm, medium grade (Class B) in standard length of 5.50 - 6.00 meter, 6mm thick complete incl jointing materails such as nuts/bolts/washers/rubber gaskets,welding etc all as specified and as directed. Note: (i) MS fittings, MS flanges, Joints shall be measured and paid for separately. (ii) Excavation and earth work shall be measured and paid for separately. |
| 30 | S&F as in replacement MS pipe fittings like MS bends, tapers, tee pieces (single & double branch) any type and angle/ radius and straight connecting pieces, tail pieces, collars etc, flanged ends dead plate required to fabricate water main header any type/ size upto 300mm bore complete all as specified and as directed. |
| 31 | M&L cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate for foundations, mass and for repairing to paths/ road & hardstanding etc. including necessary cutting of roads/ paths for passing of pipes and making good the disturbed portion complete all as specified and directed by Engineer – in - Charge. |
| 32 | S&F as in repairs DI air release valve double orifice isolating type with SS Ball as per IS :14845,PN-1.0 flanged ends of size 150 mm dia complete all as specified and directed . |
| 33 | S&F as in repairs DI air release valve double orifice isolating type with SS Ball as per IS :14845,PN-1.0 flanged ends of size 100 mm dia complete all as specified and directed . |
| 34 | S&F as in replacement CI foot valve 150 mm dia as per IS:4038 PN 1.0 with flanged end complete incl jointing materials such as nuts, bolts, washers, gaskets etc and incl dismantling and taking out the suction pipe & refixing in original position complete all as directed. |
| 35 | M&L repair, maintenance of areation system and floculator bridge as under:(a) Replacment of copper slipring unit for floculater bush size i.e inner dia of slipring unit 44.5 mm, slipring unit including carbon brush and its holder full set unit box type i.e all the assembly will be inside the 3 wire for input and 3 wire output, levelling of roller on track as including copper connector and connection to rotating bridge panel.(b) Replacment of CI coupling 12'' including bushing and necessary nut bolts etc.(c) Ball Bearing of size 10'' as per sample (d) MS Shaft 44.5 mm dia,1.8 mtr long.(e) Distance piece for supporting of bridge(f) Overhauling reduction gear as per existing ratio (1:25 and 1:30) incl supply of fix spare as oil gear bush nut bolt etc to make fully functional. |
| 36 | Note:(i) Existing slipring connection and cable is in bottom side of erection system now connection is to be done top of slipring and cable. (ii) Maintance/ replacement of the bridge to done by contractor for 6 month after completion of work by free of cost. |
| 37 | Supply & fixing of fan belt (Size B32/ B34) for reduction gear all as speicified and directed by Engr - In - Charge. |
| 38 | Supply of gear oil for reduction gear all as specified and directed by Engr-in-charge. |
| 39 | M & L removing, repairing, refixing of Agitator assembly of flash moisture tank including servicing/ providing new parts as required: (a) Removing repairing and refixing including overhauling greasing, painting etc(b) Bearing of suitable for agitator in Clarifier parts(c) V belt of size B 32/34 as specified and directed by Engr-In-Charge. |
| 40 | M & L providing two coats of synthetic enamel paint and a coat of red oxide primer on new steel surfaces including preparation of surface of any description over 10 cm width or girth all as specified and directed by Engineer - in - Charge . |
| 41 | M & L as in replacement of stainless steel sluice valve spindle threaded rod as per existing size upto 150 mm with nuts, gutka all as specified and directed by Engr-in-Charge. |
| 42 | M & L as in replacement of stainless steel sluice valve spindle threaded rod as per existing size upto 200 mm with nuts, gutka all as specified and directed by Engr-in-Charge. |
| 43 | M & L as in replacement of stainless steel sluice valve spindle threaded rod as per existing size upto 250 mm with nuts, gutka all as specified and directed by Engr-in-Charge. |
| 44 | M & L as in replacement of stainless steel sluice valve spindle threaded rod as per existing size upto 300 mm with nuts, gutka all as specified and directed by Engr-in-Charge. |
| 45 | M & L as in replacement of stainless steel sluice valve spindle threaded rod as per existing size upto 600 mm with nuts, gutka all as specified and directed by Engr-in-Charge. |
| 46 | Supply, Installed, Testing and Commissioning CPRI approved cubical type LT Panel floor mounted out door type for 415V, 3 phase 4 wire sysytem 50 Hz AC supply, factory made fabricated from CRCA sheet totally enclosed, dust weather and vermin proof for outer shell and 2 mm thick for inner shell having TPN copper bus bar rating 1.5 times that of controlling MCCB supported on SMC insulator with short circuit withstand capacity 05 MVA for 1 second, bottom base channel MS section not less than 50mm x 50mm x 5 mm thick, entire panel shall have a common aluminium earth bar of size 25mm x 5mm at the rear with 2 Nos earth stud, solid connection from main bus bar to switchgears with required size of copper wiring with minimum 1.5 Sqmm PVC insulated copper conductor cable, cable alleys, cable gland plates in two half inculding tamper proof digital energy meter to measure volatge current KWH, and general construction confirming to IS-8623/93 and mounted on suitable PCC foundation with follwoing detailed specification & control complete with suitable fixing accessories. |
| 47 | OUTER SHELL :- The outer shell shall be made of 3.0 mm thick CRCA body & MS angle section 50x50x6 mm frame with front & back openable, single door system lockable/ openable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate ahing provision for entry of armoured cable of adequite size of glands. The dimension of the outer shell shoild be adequite to accommodate inner shell described below having 50 mm space all around and shall be fabricated in such a way that the comple inner shell alongiwth its control gears and accessories should be taken outside without disturbing outer sheel. The outer shell shall be mounted on a zinc metal coated stand. Provision of threaded earthing studs at bottom and lifting lugs of suitable size at top to lift the feeder pillar box safely shall be made. Computer cut self adhesive vinly danger notice plate having conventional symbol of bone and skull shall be provided. The degree of protection of outer shell shall be IP-54. |
| 48 | INNER SHELL :- Inner shel made of 2.0 mm thick CRCA body compartmentalized for each control gear, front openable single door system lockable/openable by keys from both sides having chromium plated fancy locks (2 Nos in each compartment) having louvers and air vents gasket for natural flow of air \\"U' type gasket shall be used to make the inner shell completely vermin proof and to accomodate incomer/outgoing MCCB's and TPN copper bus bar and extension links of rating not less than the 1.5 times rated capacity of the respective MCCB's. The TPN bus bar and exension links shall be insulated with colour coaded heat, shrikable sleeve and shall be mmounted on suitable size 'F' class through out the length of the TPN bus bar. Computer cut slef adhesive vinyl danger notice plate having conventional symbol of bone and skull shall be provided on bus bar chamber. |
| 49 | All control wires shall be with not less than 1.5 Sqmm multistranded copper conductor and shall be properly bunched. tied, ferruled for proper identification and crimped with adequite size of lugs. The cubical shall have a bottom channel of size 75x50mm duly coated with zinc metal coating. A detachable predrilled gland plate of thickness 3.15 mm zinc metal coated should be used at the bottom, indicating lamps LED type, 230 Volt, AC at the incomer of the unit to show three phase availablity at the incomer. An inspection lamp with 5 Watt LED shall be fitted on top side of inner shell. The degree of protection for inner shell shall be IP-42 and carrying the following control :-(a) Copper bus bar three phase & neutral Cap 1.5 times of Current carrying Cap of Main Incoming MCCB (i) MCCB 3 pole 63 Amps, 16 kA - 01 Nos adjustable thermal &fixed magnetic type (for incoming). |
| 50 | (ii) MCB, 3 pole(TPN), 40 Amps, 10 kA - 07 (6+1 Spare) Nos (for outgoing), C Curve, ISI marked. (iii) Digital type Voltmeter Size 96X96 mm accuracy class 0.5 - 01 Nos, (iv) Digital type Ammeter Size 96X96 mm accuracy class 0.5 - 01 Nos, (v) DOL starter 3 HP - 06 Nos. (vi) LED Type Indicator Lamps - 03 Nos. (vii) AC three phase static Energy meter of accuracy class 1.0, 3X240 V 50 Hz with backlite LCD DIsplay of rating 5-20 A(Measures and display KWh Only) |
| 51 | Note:- (a) The Panel shall be made by CPRI approved manufaturer .(b) The bottom of the panel shall be upto 0.50 mtr above the finished floor level including necessary welding for fixing (c) Item rate deemed to be included dismantling the existing unserviceable LT Panel. |
| 52 | S&F PVC insulated and sheathed unarmoured multistranded copper conductor 3 core 6 Sqmm all as specified and directed . |
| 53 | S&F as in replacement 80mm bore CI sluice valve heavy duty class PN 1.6, ISI marked (IS-14848) both end flanged with stainless steel spindle with cast iron hand wheel including jointing material like rubber insertaion sheet 3 mm thick, bolt, nuts and fixed to pipe line, testing complete all as specified and directed by Engineer-in-charge. |
| 54 | S&F as in replacement 100mm bore CI sluice valve heavy duty class PN 1.6, ISI marked (IS-14848) both end flanged with stainless steel spindle with cast iron hand wheel including jointing material like rubber insertaion sheet 3 mm thick, bolt, nuts and fixed to pipe line, testing complete all as specified and directed by Engineer-in-charge. |
| 55 | S&F as in replacement 150mm bore CI sluice valve heavy duty class PN 1.6, ISI marked (IS-14848) both end flanged with stainless steel spindle with cast iron hand wheel including jointing material like rubber insertaion sheet 3 mm thick, bolt, nuts and fixed to pipe line, testing complete all as specified and directed by Engineer-in-charge. |
| 56 | S&F as in replacement 200mm bore CI sluice valve heavy duty class PN 1.6, ISI marked (IS-14848) both end flanged with stainless steel spindle with cast iron hand wheel including jointing material like rubber insertaion sheet 3 mm thick, bolt, nuts and fixed to pipe line, testing complete all as specified and directed by Engineer-in-charge. |
| 57 | S&F as in replacement 250mm bore CI sluice valve heavy duty class PN 1.6, ISI marked (IS-14848) both end flanged with stainless steel spindle with cast iron hand wheel including jointing material like rubber insertaion sheet 3 mm thick, bolt, nuts and fixed to pipe line, testing complete all as specified and directed by Engineer-in-charge. |
| 58 | S&F as in replacement CI butterfly valve of 300 mm bore, wafer type, PN 10, ISI marked inluding jointing material complete all as specified and directed. |
| 59 | S&F as in replacement CI butterfly valve of 150 mm bore, wafer type, PN 10, ISI marked inluding jointing material complete all as specified and directed. |
| 60 | S&F as in replacement cast iron non return valve 150 mm dia class PN 1.0, ISI marked with flanged ends complete incl jointing materials such as nuts, bolts, washers, gaskets etc complete all as directed. |
| 61 | S&F as in replacement cast iron non return valve 200 mm dia class PN 1.0, ISI marked with flanged ends complete incl jointing materials such as nuts, bolts, washers, gaskets etc complete all as directed. |
| 62 | S&F as in replacement cast iron non return valve 250 mm dia class PN 1.0, ISI marked with flanged ends complete incl jointing materials such as nuts, bolts, washers, gaskets etc complete all as directed. |
| 63 | M&L Gland packing of sizes 8 mm to 12.5 mm thick. |
| 64 | M&L for Bacteriological/Chemical testing and analysis with preparation of detailed report as per IS 10500:1991 after collection of samples at various locations all as specified and directed by Engr-In-Charge.Note: (a) the testing will be conducted by Govt Approved Labs/NABL labs only (b) the contractor will make suitable arrangements for collection of sample water with prior intimation to Engr-in-Charge. (c) Test report should be submitted to the office by the Contractor. |
| 65 | S&F as in replacement, end -section pressure pump with axial suction port radial discharge port 0.5/0.7KW/HP single phase 220-240 Volts, min head 34 mtr, min flow 3.1cum/hr, RPM 2900, Rated current: 3.1 - 2.8 amp, enclosure class (ICE34-5) IP55 with pressure controller for costant water pressure, incl pressure meter, pressure tank 24 ltr for constant water, material SS 304 with incl complete GI fitting for fixing of pump with exiting pipe inlet & outlet 20/25 mm bore complete all as directed. |
| 66 | Supply and install as in replacement retro reflective sign boards for water supply installation of size 4 feet x 5 feet (print area) as per the following specifications:- (a) Post (pillar type) 55 mm dia 2 mm thickness SS 304 grade 9.5 feet long -02 Nos fittted with MS base plate 150 mm x 150 mm x 5 mm thickness at the bottom and 50 mm dia SS half balls on the top (b) Pipe for print area frame using 32 mm dia 1.2 mm thickness SS 304 Grade pipe and 06 Nos connecting pipes of 50 mm length.(c) SS rivetted strip 2 mm thickness and size 30 mm length & 25 mm width- 16 Nos.(d) 3 mm thick ACP sheet (aluminium composite sheet) of size 4 feet x 5 feet along with 1 mm thickness retro reflective material for approved colour and writing work in capital letters and numbers/ photographs on both sides of ACP sheet all as specified and directed by Engr-in-charge.(e) PCC 1:2:4 type B-1 block of size 300 mm x 300 mm x 450 mm- 02 Nos for grouting of sign board incl earth work complete all as specified and directed. |
| 67 | S&F as in replacement fully automatic Star-Delta Starter motor starter 75/55 HP/KW three phase, 415V with protection degree IP 54 extended wide band coil FRLS (Fire retardant low smoke ) internal wiring Air break HSN, suitable size contactor and overload relay range not less than 100 Amp as per specified and directed by Engr-in-charge. |
| 68 | S&F as in replacement DOL starter for induction motor capacity of 5 HP Single phase, 415 V, 50 Hz as per specified and directed by Engineer-in-charge. |
| 69 | Demolition of brick work built in cement mortar all as specified and directed by Engineer - in - Charge. |
| 70 | M & L brick work with sub class ‘B’ old size burnt bricks straight or curved on plan exceeding 6.0m mean radius built in cement mortar 1:4 all as specified and directed by Engineer – in – Charge. |
| 71 | M&L for rendering 15mm thick on fair face of brick work in CM 1:4 finished aven and smooth complete all as specified and directed. |
| 72 | M & L as in repairs for framed work for valve pit chamber cover made of MS equal angle and MS sheet 3 mm thick including welding, cutting, hinges, locking arrangments including painting complete all as specified and directed. |
| 73 | M & L cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in lintels up to 1.5 m clear span, seismic and other similar bands, benching, coping, bed blocks, apex stones and kerbs etc including use of necessary form work all as specified and directed by Engineer - in - Charge . |
| 74 | Taking up or down steel tubing 100mm bore and connections for refixing/ removal complete all as specified and directed by Engineer - in – Charge. |
| 75 | Taking up or down steel tubing 80mm bore and connections for refixing/ removal complete all as specified and directed by Engineer - in – Charge. |
| 76 | Taking up or down steel tubing 50mm bore and connections for refixing/ removal complete all as specified and directed by Engineer - in – Charge. |
| 77 | Taking up or down steel tubing 40mm bore and connections for refixing/ removal complete all as specified and directed by Engineer - in – Charge. |
| 78 | Taking up or down steel tubing 25mm bore and connections for refixing/ removal complete all as specified and directed by Engineer - in – Charge. |
| 79 | Taking up or down steel tubing 20mm bore and connections for refixing/ removal complete all as specified and directed by Engineer - in – Charge. |
| 80 | Taking up or down steel tubing 15mm bore and connections for refixing/ removal complete all as specified and directed by Engineer - in – Charge. |
| 81 | Refixing old steel tubing and connections including cleaning internally & externally in new or old position in trenches 100mm bore including all fittings all as specified and directed by Engineer - in - Charge. |
| 82 | Refixing old steel tubing and connections including cleaning internally & externally in new or old position in trenches 80mm bore including all fittings all as specified and directed by Engineer - in - Charge. |
| 83 | Refixing old steel tubing and connections including cleaning internally & externally in new or old position in trenches 50mm bore including all fittings all as specified and directed by Engineer - in - Charge. |
| 84 | Refixing old steel tubing and connections including cleaning internally & externally in new or old position in trenches 40mm bore including all fittings all as specified and directed by Engineer - in - Charge. |
| 85 | Refixing old steel tubing and connections including cleaning internally & externally in new or old position in trenches 25mm bore including all fittings all as specified and directed by Engineer - in - Charge. |
| 86 | Refixing old steel tubing and connections including cleaning internally & externally in new or old position in trenches 20mm bore including all fittings all as specified and directed by Engineer - in - Charge. |
| 87 | Refixing old steel tubing and connections including cleaning internally & externally in new or old position in trenches 15mm bore including all fittings all as specified and directed by Engineer - in - Charge. |
| 88 | Refixing old steel tubing and connections including cleaning internally & externally in new or old position (walls, ceiling, floors, etc.) 25mm bore including all fittings all as specified and directed by Engineer - in - Charge. |
| 89 | Refixing old steel tubing and connections including cleaning internally & externally in new or old position (walls, ceiling, floors, etc.) 20mm bore including all fittings all as specified and directed by Engineer - in - Charge. |
| 90 | Refixing old steel tubing and connections including cleaning internally & externally in new or old position (walls, ceiling, floors, etc.) 15mm bore including all fittings all as specified and directed by Engineer - in - Charge.Note (for item 82 to 84):-1. Work will be executed upto (Ground+4 storey building). Necessary arrangement for replacement/ fixing of new pipe along the wall included in quoted amount. |
| 91 | S&F 100mm bore medium grade steel tubes galvanized with all fitting including cutting threading connection in new or old position for laid in trenches all as specified and directed . |
| 92 | S&F 80mm bore medium grade steel tubes galvanized with all fitting including cutting threading connection in new or old position for laid in trenches all as specified and directed . |
| 93 | S&F 50mm bore medium grade steel tubes galvanized with all fitting including cutting threading connection in new or old position for laid in trenches all as specified and directed . |
| 94 | S&F 40mm bore medium grade steel tubes galvanized with all fitting including cutting threading connection in new or old position for laid in trenches including taking down old existing pipe, all as specified and directed . |
| 95 | S&F 25mm bore medium grade steel tubes galvanized with all fitting including cutting threading connection in new or old position for laid in trenches all as specified and directed . |
| 96 | S&F 20mm bore medium grade steel tubes galvanized with all fitting including cutting threading connection in new or old position for laid in trenches all as specified and directed . |
| 97 | S&F 15mm bore medium grade steel tubes galvanized with all fitting including cutting threading connection in new or old position for laid in trenches all as specified and directed . |
| 98 | S&F 25mm bore medium grade steel tubes galvanized with all fitting including cutting threading connection in new or old position for laid in wall/ceiling/ floor all as specified and directed . |
| 99 | S&F 20mm bore medium grade steel tubes galvanized with all fitting including cutting threading connection in new or old position for laid in wall/ceiling/ floor all as specified and directed . |
| 100 | S&F 15mm bore medium grade steel tubes galvanized with all fitting including cutting threading connection in new or old position for laid in wall/ceiling/ floor all as specified and directed .Note (for item 93 to 95):-1. Work will be executed upto (Ground+4 storey building). Necessary arrangement for replacement/ fixing of new pipe along the wall included in quoted amount. |
| 101 | S&F as in repairs gunmetal globe or gate valve with iron wheel head, screwed both ends for iron pipes 50mm bore as in repairs complete all as specified and directed by Engineer – in – Charge. |
| 102 | S&F as in repairs gunmetal globe or gate valve with iron wheel head, screwed both ends for iron pipes 40mm bore as in repairs complete all as specified and directed by Engineer – in – Charge. |
| 103 | S&F as in repairs gunmetal globe or gate valve with iron wheel head, screwed both ends for iron pipes 25mm bore as in repairs complete all as specified and directed by Engineer – in – Charge. |
| 104 | S&F as in repairs gunmetal globe or gate valve with iron wheel head, screwed both ends for iron pipes 20mm bore as in repairs complete all as specified and directed by Engineer – in – Charge. |
| 105 | S&F as in repairs gunmetal globe or gate valve with iron wheel head, screwed both ends for iron pipes 15mm bore as in repairs complete all as specified and directed by Engineer – in – Charge. |
| 106 | Repair to chloronome gaseous plant by means of defective worn out partsNote :- Spare parts required will be measured and paid seperately. |
| 107 | Supply only following part/items for chlorination plant of JESCO make :- |
| 108 | Inlet Valve |
| 109 | O' Ring set for measuring Glass |
| 110 | Back stop Cat Part No 20435060 |
| 111 | Measuring GlassO-Rings upto 4 kg/hr |
| 112 | Non return valve without back pressure regulator up to 4 Kg |
| 113 | Ejector A/B/E type |
| 114 | Activated Carbon filter |
| 115 | Safety shut off valve |
| 116 | Pressure line injector |
| 117 | PVC Valve holder |
| 118 | Set screw of measuring glass tube upto 4000 gms/hrs |
| 119 | Vacuum regulator without inlet valve with measuring glass Measuring Glass upto 4000 gms/hrs |
| 120 | Supply and fix PVC connecting tube white colour suitable size for chlorination plant complete all specified and directed by Engr-in-charge. |
| 121 | Supply and fixing Leaf Rack with Aluminum Frame.Make:- ION EXCHANGE/ CANDY/ AQUANOMICS |
| 122 | Supply and fixing Telescopic Pole for cleaning of the Filter beds and clearifire, of 4.8 Mt in length, MOC- Aluminum Make:- ION EXCHANGE/ CANDY/ AQUANOMICS |
| 123 | S & F as in replacement chloronome gaseous plant (Chlorinator) of Capacity 4000 gms/hr In built parts Vacuum regulator with inbuilt Filter , Pressure Gauge ,In built Measuring Glass with dose rate adjuster, Vacuum Ejector, Ejector Non Return Valve, PE tubing, 32 mm Spanner complete all as specified and directed. |
| 124 | M & L for cleaning , scraping out old rubbed paint / rust & appling one coat of rubber synthetic paint over a coat of primer on LT Panel/Stater Panel complete all as specified and directed by Engr-in-Charge. |
| 125 | S&F(in replacement) MCCB 4 pole with neutral link 160 Amp 25 KA including the cost of suitable for existing panels |
| 126 | S&F (in replacement) MCCB 4 pole with neutral link 200 Amp 36 KA including the cost of suitable wooden board,lugs and grouting etc . |
| 127 | S&F(in replacement) MCCB 4 pole with neutral link 250 Amp 36 KA including the cost of suitable wooden board,lugs and grouting etc |
| 128 | S&F(in replacement) MCCB 3 pole with neutral link 100 Amp 25 KA including the cost of suitable for existing panels |
| 129 | S&F(in replacement) MCCB 3 pole with neutral link 125 Amp 36 KA including the cost of suitable for existing panels |
| 130 | S&F(in replacement) MCCB 3 pole with neutral link 160 Amp 36 KA including the cost of suitable for existing panels |
| 131 | Supply and fix in replacement 3 pole power contactor 415 volt 50 Hz, 185 Amp complete all as specified and directed. |
| 132 | S&F Electrical insulating mat as per IS 15652:2006, with anti skid design, 1.1 KV grade, 3mm thick, 1 mtr wide, type-C, complete all as specified and as directed. |
| 133 | S&F in replacement, waterproof light fitting, IP-68, Green colour, aluminium body, LED 10 W complete all as specified and as directed. |
| 134 | S&F in replacement, waterproof light fitting, IP-68, RGB colour, aluminium body, LED 10 W complete all as specified and as directed. |
| 135 | S&F in replacement, waterproof light fitting, IP-68, RGB colour, Stainless Steel body, LED 10 W complete all as specified and as directed. |
| 136 | S&F in replacement, waterproof light fitting, IP-68, Red colour, Stainless Steel body, LED 10 W complete all as specified and as directed. |
| 137 | Supply and fixing as in replacement of 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor and overall PVC sheathed in service connections one twin core cable flat or circular of size 10 sqmm complete all as specified and directed by Engineer-in-Charge. |
| 138 | Supply and fixing as in replacement of 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor and overall PVC sheathed in service connections one twin core cable flat or circular of size 6 sqmm complete all as specified and directed by Engineer-in-Charge. |
| 139 | Supply and fixing as in replacement of 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor and overall PVC sheathed in service connections one twin core cable flat or circular of size 4 sqmm complete all as specified and directed by Engineer-in-Charge. |
| 140 | Repairs to existing Block masonary valve pit of internal size 1500x1500x1000mm as per following:-(a) Replacement of MS sheet cover with 6.0 mm thick MS sheet with hinge & Locking arrangement and S&F 25x25x6 mm angle iron frame all around the MS cover by welding.(b) Complete plastering work to be taken down and to be plastered 15 mm thick in cement mortar (1:6) including WPC (c) Demolition of floor & M&L 100 mm thick PCC (1:2:4) type B1 (d) M&L painting on MS cover & frame with two coat of red oxide primer after necessary prepration of surfaces all as specified and directed |
| 141 | Dismantling of existing 16 inch mechanical butterfly valve by gas cutting from exisiting MS pipe, breaking/ cutting of existing PCC flooring dismantling Joint and flange by welding, and shifting of unsv mech butterfly valve to civil work shop for repair of gear any type including lath work, greasing, replacement of following parts and refixing the same in its original position with and including necessary PCC work and testing etc ,Installed at MDPH complete all as specified and directed. |
| 142 | Dismantling of exisiting Water gate valve 6 inch (150mm) nominal dia shifting the valve to work shop for repair, including lathwork for making thread and any other work and replacement of Spindle, nut and bolts, as per requirement and refixing the same in its orginal position and testing as per direction of Engr-in-Charge complete all as specified and directed. |
| 143 | Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends each screwed end to be fitted with washers and one hexagonal or square nut. |
| 144 | Supply & fix of rubber packing sheet 3 mm Thick all as specified and directed. |
| 145 | Supply & fix of rubber packing sheet 6 mm Thick all as specified and directed. |
| 146 | Supply and fixing of copper thimble for 10 to 35 Sqmm cable |
| 147 | Supply and fixing of copper thimble for 50 to 95 Sqmm cable |
| 148 | Supply and fixing of copper thimble for 120 to 150 Sqmm cable |
| 149 | Supply, Installation, Testing and Commissioning of Indoor type Water Level Display Panel (including taking down of old unservicable panel) suitable for 01 no. Ultrasonic Level Sensor and 01 no. Sump/OHT.Panel shall be wall Mounted of suitable size made out of 1.6 mm CRCA sheet totally enclosed dust and vermin proof, indoor type and properly powder coated. The display panel shall consist of a) 7 Segment LED single display ,4 digit single display process indicator. b) Signal input: (-5 to 56mV, 0 to 10V DC, 0/4 to 20 mA DC), Re-transmission analog output. c) Alarm indication. d) Universal Input Thermocouple (J,K,T,R,S) / RTD (PT100) Single inputs (DC): -5 to 56mV, 0 to 10V, 0/4 to 20mA. e) RS485 MODBUS RTU protocol. f) Sensor Supply 24V DC 30mA optional ,SMPS power supply. g) Selector Switch. h) Indicator Lamp. i)Audio Signal Generator. j) Internal wiring. (0.5 sq. mm multistranded. k) Connector and MCB of suitable rating Make: Automation & Tech Solutions / Recktronic Devices & Systems / RKOM Solutions |
| 150 | Supply, Installation, Testing and Commissioning of Ultrasonic Level Sensor (including taking down of old unservicable panel) with following specifications: Supply Voltage and Current:10 to 30 V dc (10% maximum ripple),100 mA max at 10 V, 40 mA max at 30 V (exclusive of load), Sensing Range:200 mm to 5 m,Ultrasonic Frequency:75 kHz burst, rep. rate 96 ms,Delay at Power-up: 1.5 seconds,Analog Output (Voltage Sourcing: 0 to 10 V dc), Minimum Load Resistance = 500 ohms,Minimum Required Supply Voltage for Full 0-10 V Output Span = (1000/RLoad + 13) V dc,Analog Output: (Current Sourcing: 4 to 20 mA),Maximum Load Resistance = 1 kΩ or ( Vsupply/0.02 - 5) ohms, whichever is lower, Minimum required supply voltage for full 4-20 mA output span = 10 V dc or[(RLoad × 0.02) + 5] V dc, whichever is greater.4 to 20 mA output calibrated at 25 °C with a 250 Ω load,Temperature: Uncompensated: 0.2% of distance/°C,Compensated: 0.02% of distance/°C . Make: BANNER, BAUMER and E+H |
| 151 | Supply, Installation, Testing and Commissioning 4 Core 1.5sq.mm. PVC sheath PVC insulated copper conductor armoured cable. |
| 152 | Supply, Installation, Testing and Commissioning 2 Core 1.5sq.mm. PVC sheath PVC insulated copper conductor armoured cable. |
| 153 | Supply and fix straight plain brass ferrule, screwed both ends for iron pipe of size 20mm bore complete all as specified and directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail