| 1 | Taking down carefully defective street light luminaries 25 watts/45 watts/60 watt/ 100 Watt and any wattage from the LT poles by disconnecting electric supply and removing from site complete all as specified and directed. |
| 2 | Supply and fixing of LED street light fittings in aluminium PDC housing, toughened glass cover,individual LEDs with secondary optics,covered with IP66 protection with surge protection 10KV of capacity 20W/25W suitable to fix in 40 mm dia GI bracket. Make:Crompton/Havells/Philips/Wipro/Bajaj |
| 3 | Supply and fixing of LED street light fittings in aluminium PDC housing, toughened glass cover,individual LEDs with secondary optics,covered with IP66 protection with inbuilt surge protection of minimum 10 kV of capacity 45W suitable to fix in 40 mm dia GI bracket. Make:Crompton/Havells/Philips/Wipro/Bajaj |
| 4 | Supply and fixing of LED street light fittings in aluminium PDC housing, toughened glass cover,individual LEDs with secondary optics,covered with IP66 protection with inbuilt surge protection of minimum 10 kV s of capacity 60W suitable to fix in 40 mm dia GI bracket. Make:Crompton/Havells/Phillips/Wipro/Bajaj |
| 5 | Supply and fixing of LED street light fittings in aluminium PDC housing, toughened glass cover,individual LEDs with secondary optics,covered with IP66 protection with inbuilt surge protection of minimum 5 kV of 100W suitable to fix in 40 mm dia GI bracket. Make:Crompton/Havells/Phillips/Wipro/Bajaj |
| 6 | S&F 32 mm dia GI tubing light grade bracket over all 1.2 mtr length with cutting as required and bend to shape with flat iron clamp of size 32 mmx4mm-02 Nos, suitable size of nut bolts and washers complete for fixing street light fittings on electric poles including taking down old unserviceable/fully rusted existing unserviceable one complete all as specified and directed. |
| 7 | S&F in repair/replacement nature switch in enclosure made out of UV stablized, FR grade special moulding compound, rust proof, electric shock proof, vermine proof outdoor pole mountable with mounting bracket made out of FI and nut, bolts, washers including cable glands, openable door with lock comprising with nature switch sensor,power contactor three phase-03nos rating, 32 amps per phase , 06 nos of MCB for max load 12-15kw including taking down existing nature switch,Ip 66 enclosure complete all as directed. Make:- Kakatiya Energy System Ltd.cat No. SWADEEP-02EC-12kw3p, IP-66 enclosure or equivalent of make Indo Asian/Legrand. |
| 8 | Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation of pole and laying of UG cable and getting out in soft/loose soil complete all as specified and directed. |
| 9 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm completed all as specified and directed. |
| 10 | Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as directed. |
| 11 | Supply and laying 16 sqmm 4 core UG cable XLPE insulated,armoured heavy duty electric cable with aluminium conductor,1100 Volts grade, cross sectional area including taking down of old unserviceable cable/ACSR complete all as directed. |
| 12 | S&F in repair/replacement junction box out door type comprising of enclosure made out of 3 mm thick CRCA sheet of size 300mmx300mmx200mm powder coated, front opening with locking arrangement including 04 Nos of aluminium busbar of 200 amps 1100 volt grade , busbar duly fixed and including post insulators with provision of 02 Nos cable gland holes suitable for 01 incoming/ 01 outgoing cable with 01 No of 06Amp MCB SP and providing with rubber bushing with provision of earthing connection nuts, bolts,with clamp of suitable size complete all as specified and directed. |
| 13 | S&F submain wiring with three run 1.5sqmm FRLSH PVC insulated copper conductor, single core cable in non metallic PVC conduit fixed on pole/surface as required complete all as specified and as directed. |
| 14 | Supply & filling sand for cushioning to the under ground cable 8 cm before laying the electric cable and 15 cm after laying the cable complete all as specified and directed.Note: Punned thickness shall be measured and paid under this item. |
| 15 | M&L for common burnt clay building bricks sub-class ‘B’ designation 75 of size 230x115x75 mm to cover LT underground cables , laid dry and flat complete all as specified and directed. |
| 16 | Supply and fixing or laying HDPE pipe 50 mm dia in trenches/ wall for protection of cable complete all as specified and directed. |
| 17 | M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 m below normal ground level, connecting to the Galvanised iron earth wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI medium grade pipe 15mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agregates with 40mm thick cover of RCC (1:2:4) type B-1 including reinforcement and one handle of 6mm dia MS bar made to shape, GI light grade 20mm bore pipe for watering, perforated at bottom, 1.75 m long placed on top edge of earth plate, charcoal and common salt filled 150 mm thick all around the earth plate with fixing arrangement, funnel wire mesh and earth work in any type of soil returning filling in and removal of surplus soil to a distance not exceeding 50 m all as per electical plate No 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. |
| 18 | S&F LED decorative Bollard light of 10W, IP65 for new generation,post -top,energy saving,environmental friendly,long life aesthetically designed with symmetrical light distribution,spun aluminium landscape luminaire with high power LEDs as light source including taking down old unserviceable bollard light of any capacity. Make : Crompton Cat No. LBLSN-10-CDL or equivalent make of Havells/Bajaj/Wipro/Philips. |
| 19 | S & F in repair/replacement battery with rated voltage 12 V and capacity 26 AH for solar street lights including taking down of old unserviceable battery. Make : Exide / Amaraja / Luminous / Microtek |
| 20 | S & F energy saving LED spike light of IP66 using COB LED of capacity 12/15 W including taking down of old unserviceable light. Make : Havells Cat No LYCUSSPS15WLED730PSYMBOTG or equivalent make of Crompton/Phillips/Wipro/Bajaj |
| 21 | S&F LED decorative Bollard light warm white of 10W, IP65 for new generation,post -top,energy saving,environmental friendly,long life aesthetically designed with symmetrical light distribution,spun aluminium landscape luminaire with high power LEDs as light source including taking down old unserviceable bollard light of any capacity , Make : Crompton Cat No. LBLTW-10-WW or equivalent make of Havells/Phillips/Wipro/Bajaj |
| 22 | S&F LED post top light warm white with IP65 protection resistant to impact and corrossion glare-free and better informaty of capacity 20 W including taking down of old unserviceable light. Make Crompton Cat No LPTH-20-WW, or equivalent make of Havells/Phillips/Wipro/Bajaj |
| 23 | S&F LED Flood light 70Watt made up of pressure die cast aluminium housing with toughened glass and high power LEDs and Secondary lenses with IP 66 protection including taking down of old unserviceable light all as specified and directed. Make: Crompton/Havells/Phillips/Wipro/Bajaj |
| 24 | Supply and fixing or laying in repair UG cable XLPE insulated,armoured heavy duty electric cable with aluminium conductor,1100 Volts grade,cross section area 06 sqmm 2 core including taking down of old unserviceable cable complete all as specified and directed. |
| 25 | M&L for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) for coping of pole/fixing of bollard light, as in benching including weathering slightly chamferred angles and finished exposed surfaced even and smooth including necessary form work complete all as specified and directed. |
| 26 | M&L for reshifting of LT pole from one location to another along with removing from ground, dismantling of PCC and transportation from one side to another complete all as specified and directed.Note: Eartwork and PCC will be measured and paid separately. |
| 27 | Schedule of Credit Please Enable Macros to View BoQ information |