| 1 | Sch 'A' Part-I (Building Works) Note:- Prepriced at par with SSR Part-II (2020) at Serial Page No 12 and contractor has to quote the estimated amount under Col 6 |
| 2 | Sch 'A' Part-II (Internal Water Supply B/R Works)Note: Prepriced at par with SSR Part-II (2020) at Serial Page No 22 and contractor has to quote the estimated amount under Col 6 |
| 3 | Sch 'A' Part-III ( Plumbing B/R Works)Note:- Prepriced at par with SSR Part-II (2020) at Serial Page No 22 and contractor has to quote the estimated amount under Col 6 |
| 4 | Sch 'A' Part-IV, (SEC-I) ( Generator Shed with Flatform B/R Works)Note:- Prepriced at par with SSR Part-II (2020) at Serial Page No 22 and contractor has to quote the estimated amount under Col 6 |
| 5 | Sch 'A' Part-IV, (Sec-II) ( Generator Shed with Flatform B/R Works)Note:- Note:- This schedule is not pre priced by MES and the pre priced rate indicated as \\"Rs.0.00\\" under Col 5 signifies this fact only. |
| 6 | M&L PCC BLOCK with sub class\\" B' straight or curved on plan, exceeding 6 m mean radius with old size bricks, built in cement mortar 1:6 complete all as specified. |
| 7 | Sch 'A' Part-V(Internal Electric Supply E/M Works)Note:- Prepriced at par with SSR Part-II (2020) at Serial Page No 22 and contractor has to quote the estimated amount under Col 6 |
| 8 | Sch 'A' Part-VI, (Sec-I) (POL Store B/R Works)Note:- Prepriced at par with SSR Part-II (2020) at Serial Page No 22 and contractor has to quote the estimated amount under Col 6 |
| 9 | Sch 'A' Part-VI, (Sec-II) (POL Store B/R Works)Note:- This schedule is not pre priced by MES and the pre priced rate indicated as \\"Rs.0.00\\" under Col 5 signifies this fact only. |
| 10 | M&L PCC BLOCK with sub class\\" B' straight or curved on plan, exceeding 6 m mean radius with old size bricks, built in cement mortar 1:6 complete all as specified. |
| 11 | Sch 'A' Part-VII, (Sec-I) (External Electric Supply E/M Works)Note:- Prepriced at par with SSR Part-II (2020) at Serial Page No 22 and contractor has to quote the estimated amount under Col 6 |
| 12 | Sch 'A' Part-VII, (Sec-II) (External Electric Supply E/M Works)Note:- This schedule is not pre priced by MES and the pre priced rate indicated as \\"Rs.0.00\\" under Col 5 signifies this fact only. |
| 13 | S&F double walled corrugated (DWC) pipe of size 50 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT/LT cable in under ground complete all as spd and directed. Make: REX/Tirupati Plastomatics Pvt Ltd |
| 14 | Supply, installation, testing and commisioning of silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, engine as per IS: 10001/10002 A and Alternator Aas per IS: 13364 complete with foundation ( as per OEM design ) , The DG set shall be of 10 KVA (8 KW) capacity, 3 Phase, 415 Volts, 50 Hz, 0.8 power factor (lagging), running at 1500 RPM suitable for continuous duty operation. The DG set shall be water cooled, skid/base frame mounted and suitable for operation on High Speed Diesel (HSD).The engine shall be 4 stroke, direct injection, naturally aspirated diesel engine with 2/3 cylinders (as per approved make), equipped with mechanical/electronic governor and 12V/24V DC self-start system with battery. The engine shall have forced feed lubrication system and safety protections including low lube oil pressure shutdown, high engine temperature shutdown and over speed tripThe alternator shall be brushless, self-excited, screen protected type with Class H insulation and IP23 protection. Voltage regulation shall be within ±1% through AVR (Automatic Voltage Regulator). The alternator shall be directly coupled to the engine.The control panel shall be Power Command/AMF type as per MES requirement and shall include MCCB/ACB protection, digital voltmeter, ammeter with selector switch, frequency meter, hour meter, R-Y-B phase indication lamps, emergency stop switch, auto/manual selector switch and inbuilt battery charger (float & boost mode).The DG set shall be mounted on a common base frame with anti-vibration mountings and integral fuel tank of minimum 50 litres capacity with fuel level indicator. The acoustic enclosure (if required) shall be weatherproof, powder coated, and designed to limit sound level to 75 dB(A) at 1 meter distance as per CPCB norms.The complete DG set shall be supplied, installed, tested and commissioned as per MES specifications and relevant IS standards.control panel with necessary meter and sound proof canopy as per CPCB norms of Capacity 10KVA. |
| 15 | Supply , install test and commissioning of AMF Panels suitable to 10 KVA DG Sets with connected acessories as follows a) Battery Charger with metering MCB 6A, SP, 10KA -10 Nos b) Electronic circuit boards with phase indication lamp 220 V, AC - 6 Nos c) Power Relays ( Cranking Relays) - 2 Nos d) Terminal Blocks with digital Volt, Amp and Frequency meter (0-400 A) - 2 Nos e) Contactor Assembly(2 Nos) - 125A f) Fuse and safety devices(MCB) C-Curve 10A, DP, 10KA- 2 Nos g) PLCs with under + over voltage relay - 2 Nos h) Cable and Connectors with ON Delay Relay - 2 Nos i) Transformer and Power Supplies as OEM Recommendations j) Isloators as per OEM Recommendations k) Aux Contactors 2 NO+NC - 6 Nos l) MCCBs Thermal 100A, TP, 36 KA - 1 Nos (with Spreader Links) m) Current Transfomer 400/5A CL-I - 6 Nos n) Rotary Handles - 1 Nos o) ON/OFF Indication Lights 220V AC- 4 Nos p) Start/ Stop push button - 2 Nos q) SMPS 10A, 12V DC - 1 No with Auto/manual selector Switch Note : Excavation , RFR, Removing and necessary foundation/ coping shall be inclusive of rate quoted |
| 16 | Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified LT feeder pillar box (KIOSK) out door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings MCCBs are to busbar spadles to fitted complete base frame of 50x50x6mm angle iron, powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete with following :-(a) Changeover switch 63A 4 pole, with thermal adjustable and adjustable magnetic setting with extended 50Hz ,415 V with rupturing capacity 35 KA-01 No. |
| 17 | S&F 25 Litre capacity storage type water heater (Geyser), BEE 5 Star rated, vertical wall mounting type made out of CRCA outer body stainless steel storage tank, titanium enamelled heating elernent thermostat, thermal cutout, glass wool including 15 mm dia 450 mm long (cold water pipe), 15 mm dia 450 mm long armourd pipe (hot water pipe) etc. complete including making necessary electrical and water connections with 2.5 Sqmm, 3 core copper, multistandred cable with top indicator plug top 15 Amp from geyser connection to socket and hold fast for fixing of new geyser. |
| 18 | Sch 'A' Part-VIII, (Sec-I) (Sewage Disposal)Note:- Prepriced at par with SSR Part-II (2020) at Serial Page No 22 and contractor has to quote the estimated amount under Col 6 |
| 19 | Sch 'A' Part-VIII, (Sec-II) (Sewage Disposal)Note:- This schedule is not pre priced by MES and the pre priced rate indicated as \\"Rs.0.00\\" under Col 5 signifies this fact only. |
| 20 | M&L PCC BLOCK with sub class\\" B' straight or curved on plan, exceeding 6 m mean radius with old size bricks, built in cement mortar 1:6 complete all as specified. |
| 21 | Sch 'A' Part-IX, (Site Clerance)Note:- Prepriced at par with SSR Part-II (2020) at Serial Page No 22 and contractor has to quote the estimated amount under Col 6 |
| 22 | Sch 'A' Part-X, (Sec-I) (External Water Supply)Note:- Prepriced at par with SSR Part-II (2020) at Serial Page No 22 and contractor has to quote the estimated amount under Col 6 |
| 23 | Sch 'A' Part-X, ( Sec-II) (External Water Supply)Note:- This schedule is not pre priced by MES and the pre priced rate indicated as \\"Rs.0.00\\" under Col 5 signifies this fact only. |
| 24 | M&L for cutting of existing road for crossing of MS/DI/CI/GI pipes for laying of any size pipes including necessary excavation and earth work including repairing the same as per existing with pre mix bituminous carpet complete all as directed by Engr-in-Charge |
| 25 | M&L for construction of stone masonry valve pit size 1.00 mtr x 1.00 mtr x 0.60 mtr (internal dimention) including stone work, PCC work and MS sheet work as per site requirement complete all as specified and directed by Engr-in-Charge Please Enable Macros to View BoQ information |
| 26 | Sch 'A' Part-I (Building Works)Note: Not Prepriced at par with SSR Part-II (2020) at Serial Page No 20 and contractor has to quote the estimated amount under Col 6 |
| 27 | Sch 'A' Part-II, Sec-I (Internal Water Supply B/R Works)Note: Prepriced at par with SSR Part-II (2020) at Serial Page No 22 and contractor has to quote the estimated amount under Col 6 |
| 28 | Sch 'A' Part-II,Sec-II (Internal Plumbing B/R Works)Note:- Prepriced at par with SSR Part-II (2020) at Serial Page No 22 and contractor has to quote the estimated amount under Col 6 |
| 29 | Sch 'A' Part-III, Sec-I (Internal Electrification Works)Note: Prepriced at par with SSR Part-II (2020) at Serial Page No 34 and contractor has to quote the estimated amount under Col 6 |
| 30 | Sch 'A' Part-III, Sec-II (Internal Electrification Works)Note: Prepriced at par with SSR Part-II (2020) at Serial Page No 34 and contractor has to quote the estimated amount under Col 6Note:- This schedule is not pre priced by MES and the pre priced rate indicated as \\"Rs.0.00\\" under Col 5 signifies this fact only. |
| 31 | Flame Proof MCB DB SPN 240 volts 8 way suitable hazadous area laden with gasses/vapours of group II(a) & II (b) as per IS 2148/1994 10 Amp 240 V AC enclosed as per IP 55 protection as per IS 2147/1962 made out of cast aluminium alloy LM 6 having earthing terminal complete all as specified and directed by Engineer-in-Charge |
| 32 | Sch 'A' Part-IV, (Road, Path & Culvert Works)Note: Prepriced at par with SSR Part-II (2020) at Serial Page No 24 and contractor has to quote the estimated amount under Col 6 |
| 33 | Sch 'A' Part-V (External Water Supply Works)Note: Prepriced at par with SSR Part-II (2020) at Serial Page No 36 and contractor has to quote the estimated amount under Col 6 |
| 34 | Sch 'A' Part-VI (External Electric Supply Works)Note: Prepriced at par with SSR Part-II (2020) at Serial Page No 36 and contractor has to quote the estimated amount under Col 6 |
| 35 | Sch 'A' Part-VII (Lightening and Arrester Works)Note: Prepriced at par with SSR Part-II (2020) at Serial Page No 36 and contractor has to quote the estimated amount under Col 6 |
| 36 | Sch 'A' Part-IV, Sec-I (Sewage Works)Note: Prepriced at par with SSR Part-II (2020) at Serial Page No 25 and contractor has to quote the estimated amount under Col 6 |
| 37 | Sch 'A' Part-IV,Sec-II (Sewage Works)Note:- This schedule is not pre priced by MES and the pre priced rate indicated as \\"Rs.0.00\\" under Col 5 signifies this fact only.Note:- Only punned thickness shall be measured & paid. |
| 38 | M&L for septic tank for (50 users) in any type soil, size 4.0 m length, 1.40 m breadth, 1.60 m depth single chamber with thickness of slab 100 mm and RCC baffle wall of thickness 80 mm complete all as per detail of reinforcement and drawing as mentioned in TD-CE/AF/STD-15/2000 Sheet no. 1/2 and 2/2 dated 05 Jan 2000, with foundation in PCC 1:2:4, brickwork and plaster in CM 1:4 with using sub class ' B ' old size brick , RCC slab covers including RCC Precast Manhole cover having 6 mm plate embedded all around/ fibre reinforced cover with angle iron frame vent shaft and sludge chambers etc , complete all as specified and directed. |
| 39 | S&F 150 mm bore, HDPE Double Wall Corrugated Pipe in any length with rubber ring joints, laid in trenches for sewage pipe complete all as specified and as directed. |
| 40 | Sch 'A' Part-IX (Site Clearance Works)Note:- Prepriced at par with SSR Part-II (2020) at Serial Page No 25 and contractor has to quote the estimated amount under Col 6 |