| 1 | (A) Integral Components (Lane level & Plaza Level )SITC of RFID ETC transceiver near Pay-axis - mounted on canopy (1 per lane), as approved by E./Ic. |
| 2 | SITC of Electronics Enclosure - (1 per lane), as approved by E./Ic. |
| 3 | SITC of Lane Controller with Industrial PC - (1 per lane), as approved by E./Ic. |
| 4 | SITC of AVC including sensors & Controller(1 per lane), as approved by E./Ic. |
| 5 | SITC of User Fare Display with mounting pole - (1 per lane), as approved by E./Ic. |
| 6 | SITC of Automatic Barrier Gate - (1 per lane), as approved by E./Ic. |
| 7 | SITC of Overhead Lane Status light (OHLS) - (1 per lane), as approved by E./Ic. |
| 8 | SITC of Traffic light with mounting pole - (1 per lane), as approved by E./Ic. |
| 9 | SITC of Loop with detector - (2 per lane), as approved by E./Ic. |
| 10 | SITC of Lane Monitoring Camera/Incident Capture Camera with mounting pole - (1 per lane), as approved by E./Ic. |
| 11 | SITC of Automatic Number Plate Recognition Camera with mounting pole (1 per lane), as approved by E./Ic. |
| 12 | SITC of Customized industrial grade keyboard - (1 per lane), as approved by E./Ic. |
| 13 | S/Laying of Cabling/Networking/Installation/Commissioning (Lump sum), as approved by E./Ic. |
| 14 | SITC of Software – Lane Level - (1 per lane), as approved by E./Ic. |
| 15 | SITC of ETC Server (01 per Plaza), as approved by E./Ic. |
| 16 | SITC of Workstations for MIS, Cashup, Audit & LSDU (Lane status display unit in control room), as approved by E./Ic. |
| 17 | SITC of 24 Port Network switch (Layer 3), as approved by E./Ic. |
| 18 | SITC of Software – Plaza level, as approved by E./Ic. |
| 19 | SITC of Broadband/Dedicated Internet Lease Line ( 02 Static IP per connection) with minimum bandwidth equivalent to 02 Mbps per lane for CCH connectivity, as approved by E./Ic. |
| 20 | SITC of UPS system incl. Batteries as required for complete ETC system, as approved by E./Ic. |
| 21 | SITC of Servo stablizer (60 KVA - 03 phase), as approved by E./Ic. |
| 22 | SITC of Network Video Recorder (NVR) for CCTV recording with adequate storage upto min. 30 days (for Booth Cameras, Plaza Building Cameras, Lane Monitoring Camera and PTZ Cameras), as approved by E./Ic. |
| 23 | (B) Other components (Lane level & Plaza Level).SITC of TFT Monitor - (1 per lane), as approved by E./Ic. |
| 24 | SITC of Thermal Receipt Printer - (1 per lane), as approved by E./Ic. |
| 25 | SITC of Violation light & Alarm (on existing pole) and Foot switch in booth - (1 per lane), as approved by E./Ic. |
| 26 | SITC of Booth CCTV camera with voice recording - (1 per lane), as approved by E./Ic. |
| 27 | SITC of Intercom Slave unit in booth - (1 per lane), as approved by E./Ic. |
| 28 | SITC of Lane Level UPS incl. Batteries - (1 per lane), as approved by E./Ic. |
| 29 | SITC of Intercom Master unit - (1 per plaza), as approved by E./Ic. |
| 30 | SITC of Firewall Hardware, as approved by E./Ic. |
| 31 | SITC of PTZ Camera Including Pole, as approved by E./Ic. |
| 32 | SITC of Geo-fenced smart attendance system with timing and face recognition, as approved by E./Ic. |
| 33 | SITC of CCTV cameras for Plaza building surveillance (server room, control room, cash room, admin), as approved by E./Ic. |
| 34 | SITC of PTZ Keyboard, as approved by E./Ic. |
| 35 | SITC of DQR For Cashless Payment, as approved by E./Ic. |
| 36 | Supply, Installation, Testing and Commissioning of LED Canopy light fixture with die cast aluminium housing, with powder coating of wattage 70-80W. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 120 to 270 V AC, 50 Hz, power factor > 0.9. High power LED's shall be SMD type and fixture shall have lumen output >100 LPW at source level, Life of fixture (Including Driver): 50K Hrs. @ L70 Lumen maintenance at 35 °C Ambient Temperature. minimum Internal Surge Protection 4KV, 20 kV external surge protector, must be having minimum IP66 & IK 07 Impact rating & IEC Classification Class I, RoHS. Fixture shall be suitable to operate at ambient temperature range of 0°C to +45°C. Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015 IES, LM 79, & TTC certificates should be provided from NABL accredited lab. ROHS compliant, BIS Certification for Luminaires & Drivers 5 Years Warranty. The work includes all the installation & mounting accessories, as approved by the department. |
| 37 | Supply and laying of 4.0 sq. mm x 3 core ISI marked, FRLS PVC insulated, single core copper conductor cable in exising conduits with proper connections, glands, etc., as approved by E./Ic. |
| 38 | Supply, installation, testing and commissioning of stand mounted panel made of 16 SWG GI sheet, double door and duly pretreated and power coated to make it weather proof. Astonomical timer MCCB 65 A , switch 3 pole TPN, as approved by E./Ic. |
| 39 | Supply and fixing of surface/Flush mounting 4ways TPN distribution board with additional metal door without MCB complete in all respect,as directed at site by Engineer in charge. Cat. A. |
| 40 | Supply and fixing of surface/flush mounting 4 ways SPN distribution board without MCB complete in all respect,as directed at site by Engineer in charge. Cat. A. |
| 41 | Supply and fixing of 40 Amp. SPMCB (10KA)C Curve. Cat. A. |
| 42 | Supply and fixing of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve. Cat. A. |
| 43 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 120 sq. mm 3-1/2 core. |
| 44 | 70 sq. mm 3-1/2 core. |
| 45 | 35 sq. mm 3-1/2 core. |
| 46 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. 120 sq. mm. |
| 47 | 70 sq. mm. |
| 48 | 35 sq. mm. |
| 49 | Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only.Incoming : 400 amp. MCCB-1 No.Outgoing : 200 amp. MCCB-1 No., 100 Amp. MCCB-2 Nos. & 63 Amp. MCCB-1 No.Cat. B. Pannel cubicle type. |
| 50 | S/F of fuse section pillar with 5 nos. outgoing circuit including L.T. switch all complete as per direction of E/Ic. |
| 51 | Supply and erection of 200 Amp. TPN tap off box on rising mains complete with HRC fuses etc. complete in all respect. Please Enable Macros to View BoQ information |