| 1 | Demolition of cement concrete unreinforced in ground floors and pavings n. exc 15cm thickness (below or above ground level) complete all as specified and as directed. |
| 2 | Demolition of brick work or stone / boulder masonry, built in cement mortar or cement lime mortar complete all as specified and as directed. |
| 3 | Taking down cement plaster of any description on brick walls or concrete surfaces including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed. |
| 4 | M&L for 25mm thick plain cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as on sub base of floor complete all as specified and directed. |
| 5 | M&L for 40mm thick plain cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as on floorings including finishing the surface even and smooth with using extra cement as on floor complete all as specified and as directed. |
| 6 | M&L for brickwork with sub class ‘B’ bricks, straight or curved on plan exc. 6m mean radius built in cement mortar (1:4) complete all as specified and as directed. |
| 7 | M&L for brickwork with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and as directed. |
| 8 | M&L for 15mm thick rendering in cement mortar (1:4) plaster on fair faces brick work or cement concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed. |
| 9 | M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint complete all as specified and as directed . |
| 10 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 11 | M&L for chequered cement concrete tiles of size 20cmx20cmx25mm thick, set, jointed and pointed in neat cement slurry with white cement and pigment in floors, over and including 20mm thick bedding layer in cement mortar (1:4) as screed bed complete all as specified and as directed. |
| 12 | M&L for endura rustic tiles of size 30cmx3cmx10mm thick, area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, as on floors, etc., set and jointed in neat cement slurry and pointed in white or colured cement to match over and including 20mm thick bedding layer in cement mortar (1:4) as screed bed complete all as specified and as directed. |
| 13 | Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and as directed. |
| 14 | M&L for hardcore of gauge of broken stone or boulders n. exc. 63mm, deposited, spread and levelled in layers n. exc. 15cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 15 | M&L for plain cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete, etc. complete all as specified and as directed. |
| 16 | M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 17 | M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade complete all as specified and as directed . |
| 18 | M&L for plain cement concrete (1:2:4) type D-2 (using 20mm graded stone aggregate) as in surface channels, drains, etc. complete all as specified and as directed. |
| 19 | M&L for plain cement concrete (1:2:4) type B-0 (using 12.50mm graded stone aggregate) as in benching and coping including necessary form work complete all as specified and as directed. |
| 20 | M&L for plain cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) providing in drain, kerbs or mud stops, rounded or chamfered on edges including necessary formwork complete all as specified and as directed. |
| 21 | M&L for 300mm bore reinforced concrete pipes, Class NP2, laid and jointed with collars complete all as specified and as directed. |
| 22 | M&L for plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipe of 300mm bore after they are laid and tested complete all as specified and as directed. |
| 23 | S&F galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and as directed. |
| 24 | Demolition of reinforced (reinforcement cut as required to facilitate demolition) cement concrete of any description and in any positions as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work and removing the same from the site complete all as specified and as directed. |
| 25 | M&L for precast RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in cover slab, set in cement mortar (1:6) complete all as specified and as directed. |
| 26 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 27 | M&L for 450mm bore reinforced concrete pipes, Class NP2, laid and jointed with collars complete all as specified and as directed. |
| 28 | M&L for plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipe of 450mm bore after they are laid and tested complete all as specified and as directed. |
| 29 | Demolition and breaking up drain pipes of 100mm dia (Salt glazed ware, AC or reinforced concrete), set in cement mortar complete all as specified and as directed. |
| 30 | S&F 110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints, fixed to walls complete all as specified and as direcetd. |
| 31 | S&F 110mm bore PVC (SWR) bends, any radius provided with access door complete all as specified and as directed. |
| 32 | S&F 75mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints, fixed to walls complete all as specified and as direcetd. |
| 33 | S&F 75mm bore PVC (SWR) bends, any radius provided with access door complete all as specified and as directed. |
| 34 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 35 | S&F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed . |
| 36 | M&L for preparation of new steel surfaces of any description exc. 10cm in width or girth not otherwise described for and applying two coats of synthetic enamel paint over and including one coat of zinc chrome red oxide primer complete all as specified and as directed.NOTE:- The contract sum shall be derived by deducting the amount shown in Schedule of Credit attached to this tender from total amount of Schedule 'A'/BOQ Please Enable Macros to View BoQ information |