| 1 | Scarifying or picking gravelled macadam or bituminous macadam surface in area exc 400 Sqm (Depth exc 50mm and n.exc 100 mm) and rectification of undulation by filling GSB material as required including rolling and compaction complete as specified and as directed. |
| 2 | M & L for supply and laying of soil mix gravel or with low grade of river bed material including forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5 m high from base complete as specified and as directed. |
| 3 | M & L for cement concrete work in pavement/ hard-standing of flexural strength 40 kg/per square centimetre using 20 mm nominal size graded crushed stone aggregate, with minimum cement continedof 400 kg/cubic meter, thickness of concrete 25 cm or less including necessary formwork complete all as specified and as directed. |
| 4 | M & L for forming 20 mm thick expansion joints filled with pre-formed bituminous fillerand top 30mm primed and sealed with sealing compound, Grade ‘B’ complete as specified and as directed. |
| 5 | M & L for forming contraction joint 65 mm deep X 10 mm wide filled with sealing compound Grade \\"B\\" after priming the contact surfaces using suitable primer complete all as specified and as directed. |
| 6 | M & L for finishing surface of concrete roads, pavements, by brooming complete as specified and as directed. |
| 7 | M & L Polythene film, black, 50 micron laid in floors complete as specified and as directed. |
| 8 | Sand filling under floors or in foundations including watering and consolidation complete as specified and as directed. |
| 9 | Supply and fixing cat eye solar reflective type of metal body alloy of size 100mm x 100mm x 20mm with PAMA striplens reflector of model No. DA 972.0 fixed with and incl MS stud of suitable size as per manufactures instructions |
| 10 | M&L for water bound macadam 75mm thick (compacted thickness) WBM with coarse aggregate of Lime stone, sand stone, flint or quarterite, grading 2 (63 to 40mm size) spread rolled and consolidated to gradient material and camber required complete as specified and as directed. |
| 11 | Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cables/foundation of poles and getting out in soft /loose soil complete all as specified and directed by Engr-in-Charge. |
| 12 | Supply and laying of Double Wall Corrugated (DWC) HDPE Pipes for underground cable protection, nominal internal diameter of 50 mm, conforming to IS 16205 (Part 24) : 2017, grade SN 8 (minimum 8 kN/m²) laid in trenches complete all as specified and as directed. |
| 13 | Returning filling in including spreading levelling watering and well ramming in layers not exc 25cm complete all as specified and directed by the Engr-in-Charge |
| 14 | Removing excavated materiasl not exc 50 mtr and depositing where directed at a level next 1.5mtr above the starting point complete all as specified and direced by the Engr-in-Charge |
| 15 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 25 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. |
| 16 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3.5 core, nominal cross sectional area of main conductor 50 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. |
| 17 | Material and labour for 7.0 metre long octagonal hot dip galvanised (minimum thickness 75micron) pole with 70mm top and 130mm bottom dia and 3mm thickness with 290x290x16 mm base plate at bottom and 4Nos M20 grade bolt, 600mm long including bracket for street light made up of the 32 mm dia GI light grade pipe complete all as specified and as directed. |
| 18 | Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directd. |
| 19 | M&L for PCC (1:4:8) type D-2, using 40mm graded aggregate as in pole foundation/foundation of feeder pillar all as specified and as directed by Engr-in-charge. |
| 20 | M&L for PCC (1:2:4) type B-2, using 40mm graded aggregate as in pole foundation/foundation of feeder pillar all as specified and as directed by Engr-in-charge. |
| 21 | M & L for MCCB 4 Pole, 415 V, fixed thermal & fixed magnetic setting type, 100 Amps with breaking capacity 25 kA complete all as specified and as directed. |
| 22 | M&L for outdoor, floor mounting type fabricated panel board made out of 3.15 mm thick CRCA sheet, 40x40x5mm MS angle base frame, powder coated RAL 7032 DARK SIEMENS GREY structure after 7-tank pretreatment cleaning process, grade E-91 100A 4 pole copper bus bar with RYB color coated heat shrinkable PVC sleeves,control and power wiring with suitable size of copper wire, insulators, nut-bolts, door gasket, door lock, hinges and other connected items with following switch gear:- Incomer : (i) 40A 4P changeover switch-01 no ,(ii) 40A 4P MCCB 18kA-01 no. Outgoings: (i) Street light time switch with (ii) 40A TP contactor, On indicator, A/M Selector switch, 32A TPN MCB 10kA-03Nos. |
| 23 | Materials and labour for Cutting roads / hard standing to a depth not less than 45 cm and not less than 45 cm wide for laying of GI pipe to draw the UG cable and making good the disturbed surfaces by filling of PCC (1:3:6) type C-2 using 40 mm graded stone aggregate and finished the surface even and smooth with out using extra cement and disposed off the surplus debris and soil to a distance not exc 50 m complete all as specified and as directed by the Engr-in-Charge. |
| 24 | M & L for 40 mm bore GI tubes light grade for cable protection supporting to poles with all fixing accessoires (clamps, nut, bolt and washer etc) complete all as specified and directed. |
| 25 | S&F sub main wiring with two run of single core PVC insulated unsheathed stranded copper conductor FR LSH wire of size 1.5 sqmm & one run of PVC insulated unsheathed stranded copper conductor FR LSH wire of size 1.5 sqmm as earth lead drawing into rigid non metalic PVC conduit of size 20 mm dia for supply to street light from pole junction box complete all as specified and as directed. Note: Three run of 1.5 sqmm cable will be measured as single length. |
| 26 | Materials and labour for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.00 mm thick burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strip 25x4 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, GI strip proected by 40 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 cm c/c bothways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I complete all as specified and as directed. Please Enable Macros to View BoQ information |