| 1 | Demolition of cement Concrete unreinforced in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as directed. |
| 2 | M&L for cement concrete type D-2 1:4:8, 75mm thick (using 40 mm graded stone aggregate) as in Sub base complete all as specified by Engr in charge. |
| 3 | M&L for Cement concrete 1:2:4 type B1(using 20 mm graded stone aggregate) 100 mm thick as in flooring complete all as specified and as directed. |
| 4 | M&L for Forming Contraction (Dummy) joints 100 mm deep x 10 mm wide,filled with sealing compound Grade 'B' complete all as specified and directed. |
| 5 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 6 | M&L for Pre-cast cement concrete block masonry with solid blocks, Type C1 1:3:6 (using 20 mm graded stone aggregate) exc. 10 cm in width and setting in cement mortar 1:6 complete all as specified and as directed. |
| 7 | M&L for 15 mm thick rendering on brick or concrete surfaces in CM 1:4 with , finishing the surface even and smooth without using extra cement complete, all as specified & directed by Engineer-in-charge. |
| 8 | M&l for two coats of cement base paint over a coat of alkali resistant primer incl preperation of new surfaces of walls complete, all as specified & directed by Engineer-in-charge. |
| 9 | M&L for cement concrete type D2 1:4:8 (40mm graded stone aggregate) in foundation, filling and mass concrete/ foundation of manhole complete all as specified and as directed. |
| 10 | Dismantling wrought iron or mild steel work of any description completely all as specified and directed0 |
| 11 | S&F mild steel works as in posts, struts, fire points structure and other section including cutting tops to shape as directed, drilling holes, notching for wire etc and flat iron fillets for work Confirming to Fe-290 (Gde E-165) etc, complete all as specified and as directed. |
| 12 | S&F in repair Galvanized, 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of posts, straining bolts,standard bolt, including securing or tying at crossing with and including provision of galvanized mild steel wire staples or steel pins, etc complete all as specified and directed (Each line of wire to be measured for the purpose of payment). |
| 13 | S&F of sand bags for Range complete all as specified and as directed by E-in -charge. |
| 14 | M&L in repair for preparation of fire range with 60% of sawdust , 40% of sieved river sand and removing fired bullets , aggregate and other waste mtlr from range of size 15.24m X 13.4m and depth n exe 1mtr and removing unsv waste from site to a distance exc 50mtr and n exc 100mtr etc complete all as specified and as directed by E-in -charge. Please Enable Macros to View BoQ information |