Tender For Electrification Work Involving The Installation Of An 11 Kv Internal Ht Line And Lt Line To Facilitate A 1000 Kva Connection (Based On Electrical Load) For A Solid Waste Plant In Gram Nidori, Pargana, Tehsil, And District Ghaziabad—Undertaken, Ghaziabad-Uttar Pradesh
TDR : 54896508
Tender Notice
BOQ
6 Days Left
Ghaziabad
Uttar Pradesh
Tender For Electrification Work Involving The Installation Of An 11 Kv Internal Ht Line And Lt Line To Facilitate A 1000 Kva Connection (Based On Electrical Load) For A Solid Waste Plant In Gram Nidori, Pargana, Tehsil, And District Ghaziabad—Undertaken
Name of Work:- No 06, xzke fuMksjh ijxuk Mkluk rglhy o ftyk xkft;kckn es Lohd`fr dh izR;kkk es Bksl vifkB IykaV es fo|qr Hkkj ij 1000 dsoh, la;kstu gsrq 11 dsoh, vkUrfjd ,p0Vh0 ykbZu o ,y0Vh0 ykbZu ds fo|qrhdj.k dk dk;ZA
Sl. No.
Item Description
1
Supply & Laying For a 1000 kVA connection, the High Tension (HT) cable requirements depend on the input voltage (typically 11 kV or 33 kV) and local utility regulations. Based on standard industrial practices, a 3 Core x 185 sq. mm XLPE armoured aluminium cable is commonly required for 11 kV systems.Work will do as per engineer incharge.
2
Supply & laying of 400 Sq mm 3.5 Core L.T Cable aluminium cable For 11 K.V.A. Key LT Cable Full Load Current (LT side) Cable Type: XLPE Insulated, PVC Sheathed, Armoured Aluminium Cable Sizing (Typical Configuration) 3.5 Core x 400 sq. mm XLPE Cable. Work will do as per engineer incharge. Work will do as per engineer incharge.
3
Supply & laying of 240 Sq mm 3.5 Core L.T Cable aluminium cable For 11 K.V.A. Key LT Cable Full Load Current (LT side) Cable Type: XLPE Insulated, PVC Sheathed, Armoured Aluminium Cable Sizing (Typical Configuration) XLPE Cable. Work will do as per engineer incharge.
4
Supply & Fixing of 1000 Amp load connection Make C.G or Schneider,cro\mton. Voltage Rating: 11 kV (Nominal), 12 kV (Maximum) Rated Current: Typically, 800A is common for 1000 kVA, providing sufficient margin) Short Circuit Breaking Capacity: 13.1 kA to 21 kA for 3 seconds (21 kA is standard for many modern tenders). Making Capacity: 50 kA (peak). Type: Indoor/Outdoor, Sheet steel-clad, floor-mounted, metal-enclosed. Operation: Motor-operated spring charge with manual override (remote trip facility is generally required). Work will do as per engineer incharge.
5
C.T. For V.C.B Protective Relay & CT Requirements Protection Type: Overcurrent and Earth Fault (O/C & E/F) relays (typically self-powered or 230V AC operated). Current Transformers (CT): Cast resin/epoxy insulated ring type, typically 30/1A, 60/5A or 100/5A, Class 10P10 for protection. Panel Metering: Ammeter (0-60A/5A) and KV meter (0-15KV) with selector switches. Work will do as per engineer incharge.
6
S/F 11KAV HT Pole SP-55 11mtr long. Work will do as per engineer incharge.
7
S/F Tee Channel. Work will do as per engineer incharge.
8
S/F Fuse Set. Work will do as per engineer incharge.
9
S/F 11 kv T.P.M.O Complete. Work will do as per engineer incharge.
10
Earthing Road 11 KVA as per inincharge of enginner direction. Work will do as per engineer incharge.
11
Supply & Fixing of 1250 KVA, 11/0.433 KV Class 50Hz ONAN Cooling typeThree Phase Copper Wound Oil Immersed, With Tapping Switch Dyn -11, type distribution transformer. Work will do as per engineer incharge.