| 1 | Shifting and Reinstallation, Commissioning of Existing Access Control System with Turnstile Tripod gate of Shivananda existing D20 Make Compatible with the existing Reader. Access Controller and Software and should be able to record the transactions in the existing setup. The new upgraded tripod Should be able to control pedestrians entering or exiting restricted area in low to medium level of security generally under some surveillances & Crowd control applications. The job includes integration of the same with existing visitor management system of solus make to the entire satisfaction of the EIC. |
| 2 | Shifting and Reinstallation, Testing and Commissioning of Existing IF based Controller of Solus Make along with software working at Hon’ble Punjab and Haryana High Court Sector 1. The firm's responsibility to ensure full functionality after relocation: Dismantling of the existing IP-based controller and associated components (readers, sensors, power supply. network links, etc.). Make: Solus.The job includes integration of the same with existing visitor management system of solus make to the entire satisfaction of the EIC. |
| 3 | Supply, Installation and Commission of the Turnstile Tripod gate with Access Control System Compatible with the existing Access Control Software. Access Controller and Software and should be able to record the transactions in the existing setup. The new tripod Should be able to control pedestrians entering or exiting restricted area in low to medium level of security generally under some surveillances & Crowd control applications. The rotation is 3 X 120 degree (Tri-arm design) for bi-directional application with high volume of pedestrian movement. Access Control reader/sensor can be mounted on the top of the cabinet on the slanting surface provided. Make :Shivananda/ Solus. The job includes integration of the same with existing visitor management system of solus make to the entire satisfaction of the EIC. |
| 4 | Supply, Installation and Commissioning of IP = based Controller along with software and should be compatible with the existing solution. One controller can control a maximum of 4 card readers or and should Control 4 door locks. Access decisions shall be made at each cioor! controller, without reference to any other control or monitoring equipment. The system shall contain comprehensive networking capabilities, supporting multi-drop / daisy chain data communications links for other remote devices however Controllers should support direct TCP/IP Communication. Make Solus |
| 5 | DSR No. 39.17 Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required.1 Run of cable |
| 6 | DSR 39.20 Supplying and drawing following core Multi mode Fiber Optic Cable having corrugated steel armoring, leser optimize 50/125 μm with HDPE jacket, LSZH (Low smoke Zero Halogen), Tight-buffered or loosetube, maximum attenuation: < 3.5 dB/km at 850 nm, < 1.5 dB/km at 1300 nm, bandwidth > 2000 MHz-km at 850 nm, > 500 MHz-km at 1300 nm compliance and certifications: ISO/IEC 11801 Ed. 2.2, ANSI/TIA-568- C.3, ITU-T G.651.1 RoHS compliant. Multi Mode Fiber shall be Central-loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793- 1/60794-1-2, ITU-T-REC G.652D and Telecordia GR-20-core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature should be – 5 0C to +50 0C and Storage Temperature should be – 5 0C to +50 0C, Maximum Attenuation ± 3.5 dB/km at Operational Wavelength 850 nm and ± 1.5 dB / km at Operational Wavelength 1300 nm . type of fiber should be 50/125 / G.652D & Refractive Index should be 1.483/1.478, The value for Mode-filed,Cladding Diameter 50 ± 2.5 μm and 125 ± 1μm correspondingly i/c splicing & marking etc complete as required.6 Core Multi Mode Optical Fiber Cable |
| 7 | DSR 1.21Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 8 | 25 mm dia |
| 9 | DSR No. 39.21.2 Supply and fixing following port Rack Mount loaded LIU with pigtail, Front-mounted cable saddles for jumper management, suitable to manage both splices and terminations, Pre-assembled shelves in multiple configurations, Rubber fiber slotted bracket built-in, metal splice shelf to protect the fibers, 2 fiber spools built-in for 900μm tight buffered fiber storing, Capable of storing up to 3 meters of 900μm tight buffered fiber per adapter, Removable front and rear covers for better access to interior of LIU, Should be Single / Multi mode LC Type fully loaded. Accessory kit consists of cable ties, mounting ear screws, and spiral wrap tube etc complete as required.12Port LIU |
| 10 | DSR No. 39.23.1 Supply and fixing of 6U Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit. Powder coatedColor- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required.6U Rack |
| 11 | DSR No. 39.1.2 Supplying, installation, Testing and commissioning of following capacity 8 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: Minimum 8 X RJ-45 Gigabit Ethernet Ports and additional 2 X 1G SFP Ports with non-blocking architecture by having Switching capacity of minimum 20Gbps and packet forwarding rate of 14Mpps or higher, 8K MAC table. Internal dual AC Power supply with operating temperature of -5 0C to +50 0C. Jumbo frame: 10KB or higher, IGMP Snooping, IGMP snooping querier and support for IGMP Snooping Fast Leave, Should create 250 or more MLD groups, MLD Snooping, Per VLAN MLD Snooping C MLD Snooping Fast Leave, STP, RSTP, MSTP, Loopback detection, Multicast filtering, VLAN Tagging, ǪOS: 8 Ǫue per port, WRR, IPv4/IPv6 Interface : minimum 100 IPv4 static route entries and minimum 50 IPv6 static route entries, 700 Acess Control entries, SSH CSSL for IPv4 and IPv6, 802.1x,ARP Spoofing, DHCP Snooping and server screening, IP+MAC+Port Binding, Per Port Bandwidth Control, 802.1X Authentication (Supports local/RADIUS database, Port-based Access Control and EAP, OTP, TLS, TTLS, PEAP Support) Cable Diagnostic feature, LLDP, LLDP-MED, SNTP/NTP, RMON, SNMP v1,v2c, v3 and SNMP Traps. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication,Government of India etc. complete as required.8 port Layer 2 Non-PoE Network Switch |
| 12 | DSR No. 39.6.1 Supplying, Installation, Testing and commissioning of 1 G single mode small Form-Pluggable (SFP) for Network Switches. Must be hot Pluggable, RoHS Complaint, etc. etc. complete as required.1G SFP Single Mode/Multi Mode |
| 13 | DSR No. 39.11 Supply of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel. 24 Ports Cat-6 Patch Panel should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. |
| 14 | DSR No. 39.12.1 Supplying, Installation, Testing and commissioning of following CAT6 Patch Cord. should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. |
| 15 | SITC of Card Reader with formats up to 85 bits, designed for mounting directly onto metal with no change in read range performance. Make HID / Tyco/ STid. |
| 16 | Software Server Re-Configuration for all the old gates shifting and configuration, addition of Two New Gates in the Access Management Software. |
| 17 | DSR 2.16 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 18 | DSR 1.14 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 19 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire Please Enable Macros to View BoQ information |