| 1 | SCHEDULE \\"A\\" Part-I (B/R & E/M Portion) (To be quoted by the tenderer) |
| 2 | Item No 01 : Construction of Sub station building RCC framed structure all as per shown in drg and specified. |
| 3 | Sch 'A' Part-II (External Electric supply) Lump sum price worked out by the contractor for (External Electric supply) as listed in Schedule 'A' Part-II against the lump sum price inserted by the MES. |
| 4 | Sch 'A' Part-III (Fencing gate and compound wall) Lump sum price worked out by the contractor for (Fencing gate and compound wall) as listed in Schedule 'A' Part-III against the lump sum price inserted by the MES. |
| 5 | Sch 'A' Part-IV (Internal Electrification) Lump sum price worked out by the contractor for (Internal Electrification) as listed in Schedule 'A' Part-III against the lump sum price inserted by the MES. |
| 6 | Note for Srl No 2 to 5The percentage above / below the SSR -2020 (part-II) rates shall be derived from the amount quoted by the contractor against Srl No. 2 to 5 by comparing it with the amount inserted / pre- priced by the department and the same shall be applicable for the items of respective schedule |
| 7 | Schedule 'A' Part-V (Miscellaneous items of works) |
| 8 | External Electric supply |
| 9 | Item No 02 : Supply & installation, testing and commissioningof 2000KVA, 33/11KV, 3Phase, 50Hz, ONANCooled,oil immersed,naturally cooled oi lnatural air natural(ONAN) WITH EXTERNAL Cooling fins copper woundoutdoor type stepdown PowerTransformer with 17 position ONLOAD Tap Changer (OLTC) (tapping range ±5% in steps of 2.5%) with remote tap cubical changer (RTCC) panel & automatic Voltage regulator (AVR) completewith first fillingof IS: 335 ISI marked filtered & dehydrated transformer oil andother standard fittings / accessories like HV Bare bushing, LV Cablebox, Buchholz Relay,OTI,WTI,Marshelling Box etc and with vector group Dyn-11 including PCC foundation for placing transformer as permanufacturer instruction/drawing complete all as specified and confirming to IS:2026 or latest IS specification for higher efficiency and manufacturer shall hold license/certificate from BIS to thiseffect. The maximum temperature rise should not exceed 45 degree celsius in oil and 55 degree centigrade in HV/LV winding when measured by resistance method after continuous full load run onan ambient temp of 55 degree celsius. Schedule 'A' Part II (External Electric supply) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 10 | Item No 02 : Supply & installation, testing and commissioningof 2000KVA, 33/11KV, 3Phase, 50Hz, ONANCooled,oil immersed,naturally cooled oi lnatural air natural(ONAN) WITH EXTERNAL Cooling fins copper woundoutdoor type stepdown PowerTransformer with 17 position ONLOAD Tap Changer (OLTC) (tapping range ±5% in steps of 2.5%) with remote tap cubical changer (RTCC) panel & automatic Voltage regulator (AVR) completewith first fillingof IS: 335 ISI marked filtered & dehydrated transformer oil andother standard fittings / accessories like HV Bare bushing, LV Cablebox, Buchholz Relay,OTI,WTI,Marshelling Box etc and with vector group Dyn-11 including PCC foundation for placing transformer as permanufacturer instruction/drawing complete all as specified and confirming to IS:2026 or latest IS specification for higher efficiency and manufacturer shall hold license/certificate from BIS to thiseffect. The maximum temperature rise should not exceed 45 degree celsius in oil and 55 degree centigrade in HV/LV winding when measured by resistance method after continuous full load run onan ambient temp of 55 degree celsius. Schedule 'A' Part II (External Electric supply) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 11 | Supply, Installation, Testing & Commissioning of Outdoor type HT 33 kV, 3-Phase, SF₆,50Hz Insulated metal clad Switchgear complete with SF6 Circuit breaker having rupturing capacity of 250 MVA (25 kA) and rated continuous current of 400 A, It shall include following Specification:- General Parameters:-Type-Outdoor, 3-Phase, SF6 Gas Insulated, Metal-Clad Type SwitchgearSystem Voltage-33 kV (Earthed Neutral System)Frequency-50 Hz ±3%Rated Continuous Current-400 AShort Circuit Breaking Capacity-25 kA for 3 secMaking Capacity-62.5 kA PeakApplicable Standards-IEC 62271-100, IEC 62271-1, IEC 60529, IS 13118Circuit Breaker (SF6 Type):-Rated Voltage -36 kV (max system 33 kV)Rated Short Time Current (1 sec)-25 kAOperating Mechanism-Spring-Charged Motor-Operated with Manual FacilitySF6 Gas Pressure-0.4–0.5 MPa nominalGas Monitoring-Pressure gauge with low gas interlock Mechanical Endurance-10,000 operationsElectrical Endurance-2,000 operations at rated currentOperating Duty Cycle-O–0.3 s–CO–3 min–COControl Circuit & Auxiliaries:-Control Supply Voltage-110/220 V AC/DCTrip Coil-2 (Main + Spare) Close Coil-1Under Voltage Release-ProvidedAuxiliary Contacts-Minimum 4NO + 4NCLocal/Remote Control-Provided with selector switchIndications-ON/OFF, Trip, Spring Charged, Spring DischargedInstrument Transformers :-CT Type-Cast Resin / Oil CooledCT Ratio-400/200/100/5A (as per system requirement)CT Accuracy-Protection 5P10, Metering 0.5PT Ratio-33kV/√3 / 110V/√3PT Accuracy-Metering 0.5, Protection 3PStandards-IEC 61869-2 / IEC 61869-3Relay & Protection System:-Protection Functions-Overcurrent, Earth Fault, Trip Circuit Supervision, UVRRelay Type-Numerical / Static (as per system design)Communication Protocol-Optional: IEC 61850 / Modbus RTUEnclosure & Busbar:- Enclosure-SS Outdoor EnclosureDegree of Protection-IP67 for CB, IP54 for Control Cabinet Busbar Material-Tinned CopperBusbar Rating-400 A, 25 kA for 1 secEarthing Terminals-2 Nos. Copper StudsCable Entry-Bottom Entry through Gland Plate Civil & Earthing Works :- Foundation-RCC foundation with anchor boltsEarthing-2x50x6 mm GI strip connected to main earth gridPainting-Epoxy / PU Outdoor Grade RAL 7032Tests :-Routine Tests-As per IEC 62271-100Type Tests-Short Circuit, Impulse, Temperature RiseDielectric Test-70 kV rms for 1 minuteImpulse Withstand Voltage-170 kVpMechanical Operation Test-10,000 operations minimumIncluded :-CTs, PTs, Relays, Control Wiring, Earthing, Civil Works and provided Test Certificates, O&M Manuals, SLDs, Drawings, Gas Filling Kit Makes :-ABB / Siemens / Schneider / CG / L&T |
| 12 | Supply & fix lightening arrestor linear resistance type complete with all fitting,distribution class suitable for 33 KV system pole mounting type conforming to IS - 3070 Part-I including taking down existing unserviceable one complete all as specified and as directed. |
| 13 | Supply and fix gang operated air break switches, triple pole, manually operated, mounted on insulators and steel frame, with operating mechanism worked from ground level Vertical/Horizontal type for rating upto 400 Amps, 11000 volts complete with GI operating pipe of heavy duty Specified and directed . Make - BHEL / JAIPURIA / RASHTRIYA / MEI . |
| 14 | Supply & fix lightening arrestor linear resistance type distribution class discharge capacity 65 kilo amp suitable for 11 KV system pole mounting type conforming to IS - 3070 Part-I complete all as specified and as directed. |
| 15 | M& L pin type , porcelain, vitreous, white, brown or green insulator, 150 mm height, 150 mm dia for 11 KV grade including one galvanised iron washer, nut and pin complete all as specified and as directed. |
| 16 | M&L Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed. |
| 17 | M&L Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination Cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm including testing complete all as specified and as directed. Make - Denson /Raychem / 3M |
| 18 | Supply, stringing and fixing of Aluminium conductor steel reinforced (ACSR) OH conductor of any type including binding wire complete all as specified and as directed. |
| 19 | M&L 20mm dia stay rod including Stay assembly complete with accessories as shown in electrical plate No. 1 complete all as specified and as directed. |
| 20 | M&L Loop type insulator, vitreous porcelain,white, brown or green Small size, with overall dimensions 65 x 90mm, clearance of hole 16mm complete all as specified and directed. |
| 21 | Earthing complete with copper plate 60×60cm ×3.15mm thick electrode, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, Connected to 20×3mm copper strip as dia by means of bolts, nuts, check nuts and washers of Copper all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion |
| 22 | M&L of danger notice plate of 1.6mm thick mild steel sheet vitreous enameled white, with letters, figures and convention skull and bones in signal red colour and S&F with MS clamps bolts and nuts of approved size for HT 11 KV of size 25 x 20 cm complete all as specified and conforming to IS : 2551-1982 |
| 23 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cables & foundation of poles ,stay assembly and getting out in any type of soil complete all as specified and directed . |
| 24 | Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete. |
| 25 | Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete. |
| 26 | Material and labour for sand cushioning to under ground cables ( 8 cm deep before laying of cable and 15 cm deep over the cable ) & punning gently complete all as specified and directed . |
| 27 | M&L in repairs for laying un-reinforced precast concrete cable cover, class HV , type 1 with , size 300 mmX180mmX 40mm complete all as directed by Engineer-in-Charge. |
| 28 | Cutting anxious green growth / vegetation growth for cleaning out the area around installations and four/two pole structure yards at ground level by cutting out roots, unwanted plants bushes and removal of the same by surface excavation not exceeding 30 cm deep average 15 cm complete. |
| 29 | M & L for stone aggregate of size n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to true surface for transformer and pole structure area complete all as specified. |
| 30 | S & F Aluminium strip 25x3 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified. |
| 31 | S & F GI strip 32 x 6 mm burieed in ground complete all as specified. |
| 32 | S & F single pointed air termination aluminium rod 12 mm dia, 300 mm long complete all as specified |
| 33 | Supplying and laying synthetic Rubber insulated mats 2 mm thick for boltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed |
| 34 | Ditto but 2.5 mm thick for voltage upto 11 kv (size 2x1m) complete all as specified and as directed. |
| 35 | Ditto but 3.0 mm thick for voltage upto 33 kv (size 2x1m) complete all as specified and as directed. Total carried over to BOQ Rs. 1818459.13 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part III (Fencing gate and compound wall) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 36 | Boring holes 3.5m deep in soil for Single under reamed piles and getting out and disposal of soil to a distance of n.exc 50m (dia of pile 300mm) |
| 37 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified. |
| 38 | M&L PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in foundation and mass concrete as in retaining wall etc complete all as specifed and directed. |
| 39 | M&L for hard core of gauge n.exc 63 mm deposited, spread and levelled in layers n.exc 15 cm thick with broken bricks, watered and rammed to a true surface complete all as specified. |
| 40 | S&F Mild steel TMT bars, 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hoopinbg for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips all as specified |
| 41 | Ditto all as per item No above but 6mm dia and over upto and including 10 mm dia in stirrups, spacers and binders |
| 42 | S&F Galvanized 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rail straining bolts incl securing or tying at crossing with and provision of galvanized mild steel wire staple or steel pins etc as directed. |
| 43 | S&F angle channel as in posts and struts in fencing including cutting tops to shape as directed drilling holes notching for wire etc, flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or rivetting etc and similar work conforming to Fe-410-0 or Fe-310-0. |
| 44 | M&L reinforced cement concrete (M-25 Design mix) (using 20 mm graded stone aggregate) in foundation, footing, foundation beams, plinth beams, bases for columns, pedestal, under reamed piles, mass concrete, etc complete. |
| 45 | M&L reinforced cement concrete (M-25 Design mix) (using 20mm graded stone aggregate) as in columns, pillars, posts, struts etc complete. |
| 46 | M&L for two coats of synthetic enamel paint on steel surfaces exc 10cm girth or width over one coat of red oxide including preparation of new surfaces. |
| 47 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed. |
| 48 | Removing excavated soil to a distance n.exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified. |
| 49 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces of concrete. |
| 50 | M&L form work to sides of pillars, posts, struts, piers, columns and stanchions for rough finished , square, rectangular or polygonal surfaces of concrete |
| 51 | M&L Brick work with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius built in CM 1:6 |
| 52 | M&L 15 mm thick rendering in two layers (10mm & 5mm ) on fair faces of bk / concrete surfaces in cm (1:4) with WPC (WPC measured & paid separetely) finished even and smooth (Without using extra cement ) complete. |
| 53 | Supply only water proofing compound (liquid), ISI marked. |
| 54 | Preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of white wash. |
| 55 | S&F MS plates (plain or chequred) channels, square cut or notched forming holes without any attachment of Fe-410W Gde E250 quality A complete all as spd and directed. |
| 56 | S&F for Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') |
| 57 | M&L for 20mm thick Granite (of any type) tiles machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of and polishing complete Total carried over to BOQ Rs. 2038798.68 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Please Enable Macros to View BoQ information Schedule 'A' Part IV (Internal Electrification) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 58 | M&L for point wiring complete with PVC insulated unsheathed, 1100 volts grade cable 1.5 Sqmm (nominal area) FRLS type multi stranded copper conductor, single core drawn and including not less than 20 mm dia rigid PVC conduit ‘medium grade’ ISI marked including all conduit accessories for concealed wiring for one light/fan/exhaust fan point controlled by one, one way switch, including concealed pressed steel terminal box of required size not less than 1.0 mm thick factory made duly painted inside & outside with two coats of black bituminous paint over & including a coat of red oxide primer, with 2.8 mm thick top cover of plastic laminated sheet of required colour for mounting switch, sockets, fan regulator etc including 1.5 Sqmm FRLS type PVC insulated unsheathed cable multi-stranded copper conductor as continuous earth wire and connected to earth dolly as required at site & including chases cutting & making good disturbed surface & applying finishes to match existing surface complete all as specified and directed. |
| 59 | Ditto - all as item No. 2 here-in-before but one 3 pin, 5 amp socket outlet on independent board complete all as specified and directed. |
| 60 | Ditto - all as item No. 2 here-in before but 3 pin, 5 amp socket outlet on the same board with other switch complete all as specified and directed. |
| 61 | All as per item no 2 above but for one 6 pin 15/16 amps socket outlet point on an independent board with cables of size 4 sqmm. Complete all as specified and directed. |
| 62 | M&L for sub main wiring with PVC insulated 1100V grade FRLS single core RM multi stranded copper conductor cable of size 2x4 sqmm + 1x4 sqmm as earth continuity cable passing through and including 25/20mm dia PVC conceal conduit all as specified and directed by Engr-in-Charge. Note - Two runs of 4sqmm including one run of 4 sqmm as earth wire including PVC conduit shall be measured as unit length. |
| 63 | S & F for switch piano, flush type, 5 amps, single pole, one way, 230 volt complete all as specified and directed. |
| 64 | S & F for 2/3 pin, 5 Amp / 6 Amp, socket outlet, flush type, 2 in 1 complete all as specified and directed. |
| 65 | S & F switch socket combination 2 in 1, 6 pin 16 Amps multipurpose type 240 volts complete all as specified and directed. |
| 66 | S & F ceiling rose single phase, PVC poly carbonate insulated body three terminals ISI marked complete all as specified and directed. |
| 67 | S & F sheet metal enclosure for 4 way TPN DB double door 415 Volt with 200 amp rated bus bar complete with suitable for 1 x 63Amp TPN as incomer and MCB SPN as outgoing connection through proper size of lugs and cable glands including taking down existing MCB DBs complete all as specified and directed. |
| 68 | Supply and fixing 415V 10KA ‘C’ curve miniature circuit breaker (MCB) of 4 poles and current carrying capacity 63 Amp in the DB complete with connection testing and commissioning complete all as specified and directed. |
| 69 | S & F MCB SP 240 Volt 6 to 40 Amp ISI marked conforming to ‘C’ curve, breaking capacity 10 KA complete all as specified and directed. |
| 70 | S & F MCB SPN 40 to 60 amp 30mA for earth leakage. Over load and short circuit protection ISI marked complete all as specified and directed. |
| 71 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below GL with top edge of plate not less than 1.50 m below normal ground level) connected to galvanised earth lead wire 4.0 mm dia (7.5 m) as means of bolts, nuts, check nuts and washer besides brazing at all joints as shown on drawings and including excavation, earth work, GI pipe (ISImark) light grade 15 mm bore for protection of GI wire from earth electrode to and including the earth test point, supplying and laying charcoal dust, common salt, PCC 1:3:6, type C-1 (using 20 mm graded crushed stone aggregate) chamber and mild steel angle iron frame 40x40x3 mm and 40 mm thick pre-cast RCC cover 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate) reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with mild steel handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade (ISI marked) for watering all as shown in electrical plate No. 3 of SSR Part-I and connected to earth test point including testing of earthing & dismantling/taking down existing old/unserviceable earthing complete all as specified and directed. (Note: The rates quoted shall also be deemed to include the cost of Earth test point and earth wire and protection pipe upto 7.5 meter beyond the earth plates electrode.) |
| 72 | S&F five stepped type electronic fan regulator socket type, compatible for BLDC fan AC 230 volt suitable for any type of ceiling fan complete all as specified and directed. |
| 73 | Supply and fixing LED lights fitting 1x20W, 220V AC decorative box type extruded aluminium housing (enhances safety) with high quality polycarbonate diffuser, 4 ft, 2000 lm, voltage protection range 140V–270V, VNW 6500K, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 74 | Supply & fix exhaust fans of metallic body heavy duty AC single phase 230/240 V of size 380 mm sweep with bracket, louver shutters, nuts & bolts including connection with PVC copper flexible wire for exhaust fans complete all as specified and directed. |
| 75 | S & F Building security/street LED light fitting 35 watt IP-65 protection pressure diecast aluminium body, heat resistant glass, including driver and making necessary electric connection with 2.5 sqmm twin core copper wire 1.5 m long complete fixed in and including GI pipe medium grade 40 mm fixed to pole complete all as specified and directed. |
| 76 | Supply, fixing and testing of ceiling fan 1200 mm sweep, heavy duty, single phase AC 230 Volts, 50Hz, BEE 5 star rating, ISI marked complete with down rod, canopy, blades, BLDC motor etc and connecting up complete including complete connection from ceiling rose to fan including writing of MES Number with synthetic enamel paint complete all as specified and as directed including taking down old unserviceable one and deposit in MES store for BER. |
| 77 | Supplying, laying, commissioning & testing cross sectional area 35 Sqmm, 3.5 core XLPE cable insulated armoured electric power cables (heavy duty) 1100 Volts grade with standard aluminium conductor including taking down existing old/unserviceable cable complete all as specified & directed. Note: Excavation & earth work, sand cushioning & bricks shall be measured & paid separately under respective item. |
| 78 | S & F for 50 mm dia GI pipe ‘light grade’ ISI marked including fittings such as bends, tees, sockets etc fixed on wall/pole or laid in trenches under road crossing/hardstanding including taking down existing pipe complete all as specified and directed. |
| 79 | M&L Sand cushioning with dry local sand for cable protecting underground cable (8 cm before laying the cable and 15 cm after laying the cable) in trenches including punning the sand upto 18 cm thick and consolidated complete all as specified and directed. NOTE: Punned thickness only shall be measured. |
| 80 | Supply and laying dry well burnt locally available brick sub class ‘B’ modular bricks laid flat with width equal to the length of whole bricks over cable as cable protection complete all as specified and directed. |
| 81 | Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each complete all as specified and directed. |
| 82 | Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc or for shafts, wells cesspits, manholes, pier holes, laying of cables etc. not exceeding 10 sq m on plan and not exceeding 1.5 m depth and getting out in soft/loose soil complete all as specified and directed. |
| 83 | Removel of surplus excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. Total carried over to BOQ Rs. 146855.27 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer |