| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) with and including removing rubbish material from building and thrown in low lying empty area complete all as specified and as directed by Engineer-in-charge. |
| 2 | Demolition cement concrete (unreinforced) in ground floor and pavings not exceeding 15cm thickness below or above ground level with and including removing rubbish material from building and thrown in low lying empty area complete all as specified and as directed by Engineer-in-charge. |
| 3 | Material and Labour 25mm thick Plain Cement concrete 1:2:4 type B-0, using 12.5mm graded Stone aggregate as levelling course complete all as specified and directed by Engr-in-Charge |
| 4 | Material & Labour for Non skid ceramic coloured joint free tiles , thickness 7mm to 8mm thick (square/ rectangular), colour as approved by Engineer-in-charge area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floor etc set and jointed in neat cement slurry @ 3.00Kg per Sqm and pointed in white or coloured cement to match the colour / shade of tiles , laid over with and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge. |
| 5 | S & F for coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in skirting surfaces set and jointed in neat cement slurry @ 3.00Kg per Sqm and pointed in white or coloured cement to match the colour / shade of tiles , laid over with and including 10mm thick rendering in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge. |
| 6 | Material and Labour for Virified Ceramic tiles light shade 10 mm thick (square/rectangular) polished, (shade as approved by Engineer-in-charge ) , area of each tiles not exceeding 0.36 sqm , in floors etc. set and jointed in neat cement slurry @ 3.00Kg per Sqm and pointed in white or coloured/ shade cement to match the colour / shade of tiles , laid over with and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge. |
| 7 | Material and Labour for Virified Ceramic tiles light shade 10 mm thick (square/rectangular) polished, (shade as approved by Engineer-in-charge ) , area of each tiles not exceeding 0.36 sqm ,in vertical surfaces etc. set and jointed in neat cement slurry @ 3.00Kg per Sqm and pointed in white or coloured cement to match the colour / shade of tiles , laid over with and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge. |
| 8 | Supply & Fixing 20mm dia 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings , laid in trenches or fixed to walls and ceilings or laid in floors complete all as specified and directed by Engineer-In-Charge. |
| 9 | Supply & Fixing 16mm dia 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings , laid in trenches or fixed to walls and ceilings or laid in floors complete all as specified and directed by Engineer-In-Charge. |
| 10 | Supply and fixing in replacement 20mm bore bib tap cast copper alloy, chromium plated, fancy type (ISI marked) with crutch or butterfly handle with capstan head, screwed down, screwed for iron pipe or for brass ferrule complete all as specified & directed by Engineer-in-charge. |
| 11 | Supply & Fixing in replacement 20mm dia Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/20mm- 125gms) complete all as specified and directed by Engineer-In-Charge. |
| 12 | Supply & Fixing in replacement 15mm dia Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/20mm- 125gms) complete all as specified and directed by Engineer-In-Charge. |
| 13 | Supply & Fixing in replacement vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) complete all as specified complete all as specified and directed by Engineer-in-charge. |
| 14 | Supply and Fixing in replacement Vitreous china wash hand basin, Vitreous china white, flat back, size of 550mm x 400 mm with Mild steel brackets, with and including cutting for and pinning in ends of brackets or erecting stand, with and including waste fittings of brass chromium plated ,with and including 32mm dia PVC waste pipe of required length complete all as specified and directed by Engineer-in-Charge. |
| 15 | Supply and Fixing in replacement PVC valveless, syphonic action type, flushing cistern, 10 litres capacity, low level, white, with inlet, ball valve, float and handle , with and including brackets, with and including 32 mm dia flush pipe of polyethylene of low or high density of PVC complete all as specified and as directed by Engineer-in- charge. |
| 16 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by Engineer-in-Charge. |
| 17 | Material & Labour Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engineer-in-Charge. |
| 18 | Material & Labour Pre- painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, Ridge and eaves board, fixed with self tapping screws complete all as specified and as directed by Engineer-in-Charge. |
| 19 | Material & Labour in replacement 4mm thick veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one face, fixed in ceiling flat and sloping with nails to timber frame complete all as specified & directed by Engineer-in-charge. |
| 20 | Material & Labour in replacement 4mm thick veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one face, fixed in wall flat and sloping with nails to timber frame complete all as specified & directed by Engineer-in-charge. |
| 21 | Dismantling of timber scantling in framed work under 40 Sqcm, in fillet rails, posts rafters purlin etc complete all as specified and directed. |
| 22 | Material and Labour Clean swan Second class hard-wood in scantlings in framed work all complete as specified and directed by Engr in charge. |
| 23 | Supply & fixing 2nd class soft wood plain fillets square rectangular or triangular in section wrought fixed with nails not exceeding 3 Sqcm bull ,splayed,chamfered or rounded on one edge or face complete all as specified & directed by Engineer-in-charge. |
| 24 | S&F 2nd cl soft wood plain fillets square rectangular or triangular in section wrought fixed with nails exc 3 Sqcm and not exceeding 6 Sqcm bull ,splayed,chamfered or rounded on one edge or face complete all as specified and directed |
| 25 | Supply & Fixing in replacement 1000 Ltr capacity Rotational Moulded Polyethylene Water Storage tank , cylindrical (vertical top Type) Triple layered white colour with closed , connectiing with and including complete accessories such as nipple, union , elbow , Tees , socket etc. or requiered size , hoisted and fixed in position complete all as specified and as directed by Engineer-in-charge. |
| 26 | Taking down chowkhats or frames with shutters of PVC door , wooden door shutter, (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed by Engineer-in- charge. |
| 27 | Taking down shutters of any description not exceeding 1.00 sqm each complete all as specified and as directed by Engineer-in- charge. Please Enable Macros to View BoQ information |
| 28 | Taking down shutters of any description not exceeding 1.00 sqm each complete all as specified and as directed by Engineer-in- charge. Please Enable Macros to View BoQ information |