| 1 | Dismantling old plaster and pointing in cement or lime and raking out joints to 15 mm. depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/l. |
| 2 | Dismantling old plaster and pointing in cement or lime and raking out joints to 15 mm. depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/l. |
| 3 | Dismantling old plaster and pointing in cement or lime and raking out joints to 15 mm. depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/l. |
| 4 | Dismantling patent stone floor including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l. |
| 5 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M 1.5 including screening curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I |
| 6 | Extra for cleaning the old surface by scrapping the entire old white wash or colour wash including cost of scaffolding all complete as per direction of E/l. |
| 7 | Providing and applying white cement-based putty of the average thickness of 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 8 | Providing two coats of plastic emulsion paint of approved shade and make over old surface including washing, cleaning and preparing the walls, scafolding, washing of floor and taxes all complete as per building specification and direction of E/l. |
| 9 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat ofexterior primer applied @ 0.90 litre/10 sqm) |
| 10 | Taking down old door and window shutters including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as perdirection of E/I. |
| 11 | Taking down chaukhats in doors including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 12 | Taking Down chaukhats in windows including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 13 | Providing and fixing factory made P.V.C. door frame of size 50x47 mm with awall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mmM.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall usingM.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineerin- Charge. |
| 14 | Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer's specification & |
| 15 | Supplying, fitting and fixing 20 guage G.C.I, sheet gate fitted on M.S. Angle frame of size 60x60x6mm. including cost of fabrication , providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/l. |
| 16 | Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direciton of E/l. |
| 17 | Providing 50 mm thick cement concrete flooring (1:2:4) with 20 mm to 6mm size graded stone chips finished with floating coat of neat cement in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royalty with all complete as per building specification and direction of E/l |
| 18 | Waterproofing for old and new roof slab: - Providing and laying waterproofing treatment of roof slab by applying two Component, factory designed, ready to use, acrylic modified flexible material applied with a brush, roller or spray waterproofing coating as per manufacture specification with following steps:- (a) Surface preparation: - providing and cleaning of the concrete surface to remove dust, oil, and grease including removal of existing loose paint/coating, and laitance by cleaning with compressed air and water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, and leakage. On identification of seepage, cement grouting to be done with non-shrink expanding admixture of sika India Pvt. Ltd. / MYK Schomberg / Dr. Fixit/ Fosroc or equivalent. Providing and repairing all corners and joints such as those between the parapet wall and roof slab etc shall be chamfered with 150mm X 150mm fillet with mortar ( cement: sand- 1:4) admixed with an acrylic polymer of sika/ Fosroc/ MYK Schomberg / Dr. Fixit/ Fosroc or equivalent. Before chamfering, a prime coat shall be given with the slurry of acrylic polymer. Repairing surface irregularities, damaged concrete base slab, dead crack if any, with acrylic polymer modification repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete.(b) 1st coat:- Apply 1st coat of two-component acrylic modified, ready to use, flexible cementitious material on the surface dry roof and inside wall of parapet wall up to 600 mm by brush or roller. after 1st coat of application, 45gsm of fiberglass cloth to lay when the first layer is still green. 1st coat should be applied @ 1.50 kg/Sqmt/coat. For measurement will be measured (c) 2nd coat:- To apply the 2nd coat of two-component acrylic modified ready to use, flexible cementitious material right angle to the 1st coat over the glass surface. 2nd coat should be applied @ 0.7 kg /sqm/coat. For measurement, Cheniere treated surface will be measured. After three days of drying the 2nd coat. the rainwater outlet is to be plugged and a ponding test is to be done for 48 hours to identify seepage, leakage from the soffit, and if found necessary rectification is to be done as per the satisfaction of E/C. the waterproof coating is to be protected from damage before screed over it. Waterproofing bond:- Sika top seal 109i / Fosroc brush bond RFX/Dr. Fixit pidiffin 2k / MYK Aquafin TG. Product Performance- chemical base part A: acrylic copolymer, Part B: specially graded cementitious powder density 1.6kg/l (mixed density) at +27 degree c tensile strength ~ 2N/mm2 after 28days (with fiber cloth )( According to ASTM D 2370) pull out bond strength ~ 2N/mm2 (concrete failure) (According to ISO 4624) Slant- Shear Bond strength ~4N/mm2 (According to FIP 5.15) elongation at Break ~35% without Fiber Cloth and 20% with Fiber Cloth (According to ASTM D 2370)(d) Protection of the treated surface with PCC:- the treated surface should be covered with 25mm/50mm PCC of M-20 grade (1:1.5:3) with proper slope (1:120) toward the rain outlet in Alterna panel of 2mtx2mt keeping 6mm gape between the plane joint integral waterproofing admixture conforming to IS 2645 @ of 100ml per bag of cement to be added in the screed concrete ( paid separately for this item) all corner shall be chamfered with 150mm x 150mm fillet. The rainwater outlet shall be just leveled with the screed concrete to ensure smooth discharge of water- the peripheral gapes between PVC pipe outlet and concrete surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insensitive epoxy putty of sika/ Fosroc/ MYK Schomberg / Dr. Fixit/ Fosroc. For measurement, the entire treated surface will be measured(e) Groove of PCC surface should be filled with polysulphide sealant. (paid separately) . brand- sika/ Fosroc/ MYK Schomberg / Dr. Fixit/ Fosroc. Warranty for five years. |
| 19 | Covering the treated surface with PCC:- 50mm thick Cement Concrete (1:1.5:3) maintaining the slop in 2mt x 2mt panels with approved quality of stone chips of 20 mm to 6 mm size graded and cleaned sand of F.M 2.5 to 3 including screening, shutting and mixing cement in mixture with an admixture of integral waterproofing and placing in position, striking curing, taxes, and royalty all complete as per building specification and direction of E/I. the panel that has been left should be cast the next day. there should be a 6mm gap between panels. Brand- sika_Plastocote plus, MYK Proof WP 10, Fosroc- conplast x 4211C,Dr. Fixit Pidiproof LW+ or Equivalent. |
| 20 | Electrification Work Wiring for light point /fan point/ exhaust fan point/ cell bell point, with 1.5 sq. mm FR PVC insulated copper conductor singel core in surface/recessed PVC conduit, with modular type switch, modular plate sutable GI box etc as required Group C |
| 21 | Twin control point wiring in pvc conduit, with modular type switch :-Wiring for twin control point in with 1.5 sp.mm FR PVC insulated copper conductor songel core cable in surface/ recessed PVC conduit, 2 way with modular switch,modular plate sutable GI box etc as required |
| 22 | Power Plug wiring in PVC Conduit (2X4 Sq.mm) :- Wiring for light/power plug with 2x4 Sq.mm FR PVC insulated copper conductor songle core cable in surface/recessed PVC conduit along with 1 No. 4 Sq.mm FR PVC insulated copper conductor single core cable for loop earthing etc. as required. |
| 23 | Circuit/Sub-main wiring in PVC Conduit:- Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required.2x1.5 sq.mm +1x1.5 sqmm earth wire |
| 24 | 2x2.5 Sqmm + 1x2.5 sqmm earth wire |
| 25 | 4x6 Sqmm + 2x6 sqmm earth wire |
| 26 | Supplying and fixing of the following size of PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20mm |
| 27 | Supplying and fixing of following modular switch / socket on the existing modular plate & switch box including connection but excluding modular plate etc. as required.1.24.1 5/6 amps, one way switch |
| 28 | 1.24.4 5/6 amps, 3 pin socket outlet |
| 29 | S/F Modular type electronic fan regulator -Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 30 | Supplying and fixing modular blanking plate on the existing modular plate & switch excluding modular plate et. As required. |
| 31 | Supplying and fixing following size / modular, G.I box along with modular base & cover plate for modular switches in recess etc as required.4/5 module (78mm x 140mm x 50mm) |
| 32 | 6 module (78mm x 205mm x 50mm) |
| 33 | 8/9 module (78mm x 230mm x 60mm) |
| 34 | Supplying and fixing suitable GI box with modular plate and cover in front on surface of in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch. Connection, painting etc. as required (For light plugs to be used in non residential buildings) |
| 35 | S/F power plug point with modular type accessories:- Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular type switch, connection, painting etc as required. |
| 36 | S/F Ceiling Rose:- Supplying and fixing 2 pin ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 37 | S/F Batten holder :- Supplying and fixing Batten/angle holder including connection etc as required. |
| 38 | Installation of exhaust fan up to 450mm sweep in the exisiting opnening, including making the hole t suit the size of the above fan, making good the damge, connection, testing , commissioning etc. as required |
| 39 | S/F T.P. MCB DB - Supplying and fixing following way, three pole and netural, sheet MCB ditribution board, 415 volts, on surface/recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way (4+24), Double door, Horizontal type |
| 40 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, \\"B\\" series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commossioning etc. as required.6/32, single pole, \\"B\\" series |
| 41 | S/F DP MCB Isolator - Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required63 amp |
| 42 | Supply Installation, testing and commissioning of follwing size ceiling fan 3 Blades confirming to IS:374:2019 including wiring the down rods of standard length (upto 30cm) with 1.5 sq.mm. FR PVC insulated, copper wire sutable for 230V 50HZ, single phase supply etc. complete as required.9.4.1 1200mm (48\\") Ceiling Fan |
| 43 | S.I.T.C of floowing rating surface mounted LED tube light fitting suitable for 230V 50HZ, single phase supply etc. complete as required9.5.2 20/22 W LED Tube light |
| 44 | Supply 12\\" dia Metal exhaust fan etc. |
| 45 | 9/10 Watt LED Bulb |
| 46 | Plumbing & Sanitary Works Providing and fixing male ended 15mm dia brass bib cock of approved quality (Wt. not less than 350 gms.) with extra socket all compere as per specification and direction of E/I. |
| 47 | Providing and fixing N.P./C.P. brass/PVC procelain shower rose of 15mm inlet etc. all complete as per specification and direction of E/I.Shower Rose - 125mm |
| 48 | Providing & fixing 15mm size pillar cock C.I. body brass spindle pillar cock of approved quality as per specification & direction of E/I.C.I. body brass spindle |
| 49 | Providing and fixing brass/C.I. stop cock of approved quality all complete as per specification and direction of E/I.20 mm dia |
| 50 | Providing and fixing G.M. non return valve Horizontal/Vertical type of approved quality as per specification and direction of E/I.Horizontal - 25 mm dia weight not less than 375 gms. |
| 51 | Making holes in walls for laying G.I. pipe and restoring the same after pipe laying as per specification and direction of E/I.125 mm thick wall |
| 52 | 250 mm thick wall |
| 53 | Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I.Mirrors of 6mm thick plate glass bevelled edge mirror including C.P brass revolving fitting 3mm ply board and C.P hinges to fix with mirror. 600mm x 450mm size |
| 54 | C.P. brass tower rail 20 mm x 600mm with bracket container |
| 55 | C.P brass liquid soap container |
| 56 | Supplying, fitting and fixing viterious white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. 'p' trap 15 litres C.I. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings C.I. or C.C. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair or viterous white glazed earthenware footrest to be fixed in floor 15mm C.I. body brass spindle stope cock of weight not less than exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/I.580mm long - With 10 lit. low level PVC cistern |
| 57 | Supplying, fitting and fixing viterous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on pointed C.I. or R.S. brackets 32m C.I. brass waste 15mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grms. 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I. |
| 58 | Supplying fitting and fixing white glazed fire's clay sink of approved make with overflow arrangment supporting on C.I or R.S. painted bracket 40 mm dia C.P. brass waste with CP brass chain and rubber plug 40 mm dia PVC waste pipe about 750 mm long with brass coupling at one endand 15 mm C.I. body brass spindal bib cock of wall and making good the same etc . all complete as per specification and direction of E/I kitchen sink 600 mm x 450 mmx200 mm |
| 59 | Supplying material and labour for constructing ispection chamber of designation class 75B brick size 750mm deep, 600x450mm internal dimension having 250 mm wall thikness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600x475mm C.I. Cover with frame (weight not less than 39kg ) alongwith earth work in excavation and 80mm thick P.C.C (1:3:6) in foundation and refilling all complete as per specification and direction of E/I. |
| 60 | Supplying, fitting and fixing C.A.R.W.D. pipe with necessary strips spikes, bends, shoes etc. including cost of carriage, all complete, as per building specification and direction of E/l.75 mm dia |
| 61 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 62 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.110 mm bend |
| 63 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement: 4 coarse sand) and making good the wall etc. complete.110 mm |
| 64 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 65 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall25 mm nominal outer dia Pipes |
| 66 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.20 mm nominal outer dia Pipes |
| 67 | Providing and fixing PTMT grating of approved quality and colour.100 mm nominal dia |
| 68 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 69 | CARRIAGE OF MATERIAL (a) Cement |
| 70 | (b) Sand |
| 71 | (c) Stone Chips |
| 72 | ADD GST(18%) |
| 73 | LABOUR CESS Please Enable Macros to View BoQ information |