|
| 1 | Dismantling floor hearth or wall/stone tiling including cement mortar bedding (but not backing ) removing serviceable tiles to store and rubbish off the premises. all as specified and directed |
| 2 | M&L for Glazed ceramic coloured (colour & shade as approved) tile 350x 250x 7mm/ 450X 350X 7mm/ 450x300x7mm thick on vertical surface such as skirting / dados set and jointed in neat cement slurry over & including 10 mm thick rendering in cement mortar (1:4) and pointed in white/ coloured cement with pigment to match the colour of tiles complete all as specifide. |
| 3 | M&L for non skid ceramic coloured tiles of design as approved 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 4 | M& L Non Skid ceramic joint free coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, over and including15 mm thick screed bed in CM 1:6 in floors etc. set and joint free in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engr in Charge. |
| 5 | M&L for Vitrified Ceramic tiles in light shade10 mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm ,over 15 mm thick screed bed in CM 1:6 in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engr in Charge.S&F in repairs PUF Insulated tank capacity 500 Litres, complete all as specified and as directed by Engr-in-Charge. |
| 6 | M&L for Machine cut kota stone slab flooring mirror finished 20-25 mm thick (each slab not less than 0.25 sqm) over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing on treads of step and landing of stair including screed bed 15 mm thick in CM 1:6 complete all as specified and directed. |
| 7 | M&L for Machine cut kota stone slab mirror finished 20-25 mm thick (each slab not less than 0.25 sqm) in riser of step ,skirting, dado and pillar over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including rendering 10 mm thick in CM 1:4 complete all as specified and directed. |
| 8 | M&L for RCC nominal mix (1:2:4) type B1 (using 20mm graded stone aggregete) as in slabs supported on walls and the like any thickness; above top of footings; including dismantling complete all as specified and directed. |
| 9 | Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200 mm thick (horizontal or sloping) for rough finished flat surface of concrete complete all as specified and directed |
| 10 | M&L Mild steel TMT bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clips complete all as specified and as directed. |
| 11 | M&L 20mm Thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 12 | M&L Providing edge moulding to Granite(single or double) slab including rounding off edges for 20 mm thick slab stone of counters vanities etc. including machine polishing to edge to give high gloss finish etc complete all as specified & directed. |
| 13 | Demolition of cement Concrete unreinforced in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as directed. |
| 14 | Material and labour for 40 mm thick cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in floors complete, all as specified & directed by Engineer-in-charge. |
| 15 | M&L for Pre-cast cement concrete block masonry with solid blocks, Type C1 1:3:6 (using 20 mm graded stone aggregate) exc. 10 cm in width and setting in cement mortar 1:6, including demolition of existing masonry complete all as specified and as directed. |
| 16 | M&L for 15 mm thick rendering on brick or concrete surfaces in CM 1:4 with , finishing the surface even and smooth without using extra cement complete, all as specified & directed by Engineer-in-charge. |
| 17 | M&L for rendering 10 mm thick in CM 1:6 using on fair faces of brick work or concrete surfaces and finish the surface even and smooth without using extra cement complete all as specified and as directed. |
| 18 | M&l for two coats of cement base paint over a coat of alkali resistant primer incl preperation of new surfaces of walls complete, all as specified & directed by Engineer-in-charge. |
| 19 | M&L for preparation of newly plastered surface of wall including chalk whiting, on plasetered surface etc and applying two coats of white wash on walls complete all as specified and as directed. |
| 20 | Taking down wooden chowkats or frames with shutter (without taking off shutter from the frames), area not exceeding 1.5 Sqm each and removal from site including iron mongry hold fasts etc.,complete, all as specified & directed by Engineer-in-charge. . |
| 21 | Taking down shutters of any description exc 1.00 Sqm but not exc 2.00 Sqm each complete all as specified and directed. |
| 22 | Taking down wooden chowkats or frames with shutter (without taking off shutter from the frames), area exceeding 1.5 Sqm and not exceeding 4.00 Sqm each, complete, all as specified & directed by Engineer-in-charge. |
| 23 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete, all as specified & directed by Engineer-in-charge. |
| 24 | S&F 2nd class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified. |
| 25 | S&F fabricated flush shutters, 30mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides complete, all as specified & directed by Engineer-in-charge. |
| 26 | Material & Labour 2nd class hardwood made 30mm thick glazed skelton shutters, open rebated and prepared to receive glass, gauge etc. divided into squares edges of framing, plain, chamfered or rounded, mitred fitted with cut and mitred beads for securing glass/gauge etc. with sizes of members of shutters as specified in SSR part-I section 8 clause 8.24(a) supplt and fixed to choukats complete all as specified and directed by Engineer-in-Charge at site. |
| 27 | S & F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete all as specified and as directed. |
| 28 | S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and as directed. |
| 29 | S&F 150mm long aluminium anodised barrel tower bolts of extruded section complete, all as specified & directed by Engineer-in-charge. |
| 30 | S&F 100mm long extruded aluminium alloy handles, fabricated type, anodised .complete, all as specified & directed by Engineer-in-charge. |
| 31 | S&F 75mm long butt hinges, medium weight, cold rolled mild steel, complete all as specified and as directed. |
| 32 | S&F Towel rail, 20mm dia brass chromium plated, 600mm long with fancy type brass chromium plated brackets on both sides and fixed to walls with steel screws and wooden/rawl plugs as in repairs complete all as specified. |
| 33 | M&L in repair 110 mm dia PVC (SWR) type \\"B' pipes single socketed in any length with rubber ring joints, laid in trenches or floors as waste pipes jointed with solvent cement complete all as specified and as directed. |
| 34 | M&L in repair 75 mm dia PVC (SWR) type \\"B' pipes single socketed in any length with rubber ring joints, fixed to wall jointed with solvent cement complete all as specified and as directed. |
| 35 | S&F in repairs 10 litres capacity PVC valveless syphonic action type low level flushing cistern white with inlet, ball valve, float and handle including brackets complete all as specified and directed by Engineer-in-Charge. |
| 36 | S & F in Repair for Vitreous China wash basin, angle back, size 600x480mm white, excluding taps, waste, chain and plug and porcelain stopper but including brackets, and waste coupling 32 mm dia & waste pipe. complete all as specified and directed. |
| 37 | S&F in repair bib taps, fancy type CP, screwed for 15mm bore of iron pipe or for brass ferrule and fixed all as specified. |
| 38 | S&F in repair 15 mm Pillar taps, fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed all as specified. |
| 39 | S&F PVC connections 15mm size with PTMT nuts of length 600mm, in repair complete all as specified and directed. |
| 40 | S & F in repair for Stainless steel indian water closet pan (Orissa pattern), of size 584.2mm x482.6mm and 3mm thick,Oval shape (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed. |
| 41 | S&F Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern ) including PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) for fixing of WC and making good floor to match the existing surface, complete all as specified and as directed. |
| 42 | M&L for 20mm, 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc, including taking down complete all as specified and as directed by Engr-in-Charge. |
| 43 | S&F in repair sheet glass assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60 cm long complete, all as specified & directed by Engineer-in-charge. |
| 44 | S&F Stainless steel soap dish (not less than 1mm thick) of type as directed,fixed to walls with chromium plated brass screws with wooden/rawl plugs,in repair complete all as specified. |
| 45 | S&F Galavanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperature 1.18mm as in gauze door/window/ventilators shutters complete all as specified and directed. |
| 46 | Supply & fixing in repairs 15mm bore Stop valves, fancy type Chromium plated, cast copper alloy,screwed down,high pressure,with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed complete, all as specified & directed by Engineer-in-charge. |
| 47 | M&L for preparing new or previously untreated wood based surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of finishing coat with synthetic varnish and all as specified and as directed. Please Enable Macros to View BoQ information |