| 1 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: All kinds of soil : |
| 2 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 3 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 4 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 5 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded |
| 6 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mmangle iron and 3mm M.S. gusset plates at the junctions and corners, allnecessary fittings complete, including applying a priming coat of approvedsteel primer. Using flats 30x6mm for diagonal braces and central cross piece |
| 7 | Brick work with F.P.S. bricks of class designation 75 in foundation and plinth including all shapes, leads, lifts and carriage of material by MT / H.L. in cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 8 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level. |
| 9 | Centring and shuttering including strutting propping etc and removal of form work |
| 10 | Foundations, footings, bases of columns etc. for mass concrete |
| 11 | Suspended floors, roofs, landing, balconies and access platforms. |
| 12 | Edge of slabs and break in floors and walls Under 20 cms wide. |
| 13 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 14 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 15 | 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) |
| 16 | 15mm Cement plaster on the rough side of single or half brick wall ofmix: 1 : 6 ( 1 cement : 6 fine sand) |
| 17 | 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand) |
| 18 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. In colour such as White, Ivory, Grey, Fume Red Brown |
| 19 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggreagate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. |
| 20 | Distempering with 1st quality acrylic distemper (ready mixed)havingVOC content less than 50 gms/litre,two or more coats on new work ofapproved manufacturer, of required shade and colour complete as permanufacturer’s specifications |
| 21 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
| 22 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work ( wood work). |
| 23 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.: Internal work-Exposed on wall 15 mm dia. nominal bore |
| 24 | 15 mm dia. nominal bore |
| 25 | 20 mm dia. nominal bore |
| 26 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover & suitable locking arrangement of Finolex, Sintex or Vectus or equivalent make & making necessary holes for inlet, outlet & overflow pipes but without fittings & the base support for tank |
| 27 | Supplying and fixing PVC cover with frame 300x300 mm for (manholes) LMR |
| 28 | Providing and laying in position flow trap inculding all fittings, complete job. (LMR) |
| 29 | Providing & fixing 15mm nominal bore C.P. brass angle valve for basin mixer and gyser points of approved for conforming to IS : 8931 |
| 30 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 31 | Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931 |
| 32 | Providing and laying in position pvc drainage pipe including all fitting and cover with cement cone 1:3:6 mix, complete job. |
| 33 | 4'' dia: |
| 34 | 3'' dia. |
| 35 | Providing and fixing 100 mm sand cast iron grating for gully trap. |
| 36 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 15 mm nominal bore |
| 37 | Providing and fixing G.I. Union in G.I. pipe including cutting andthreading the pipe and making long screws etc. complete (new work) 15 mm nominal bore |
| 38 | Wiring for light point, fan point/exaust fan point/call bell point with 1.5 sqmm FRLS PVS insulated copper conductor single core cable in surface/recessed PVC conduit, with modular switch, modular plate, suitable GI Box earthing the point with 1.5 sq. mm Frils PVS insulated copper conductor single core cable etc as required. |
| 39 | carriages of materials by mechinical trancsport incl. loading, unloading and stacking complete |
| 40 | Sand for a lead of 4 kms. |
| 41 | stone agg below 40mm 4 kms |
| 42 | stone agg 40 mm and above 4 kms |
| 43 | Bricks for an avg lead of 4 kms Please Enable Macros to View BoQ information |