| 1 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and directed. |
| 2 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15cm thickness (below or above ground level), including removal of rubbish outside MoD land, complete all as specified and as directed. |
| 3 | Taking down Chowkats or frames from the opening of size not exceeding 1.5 sqm each with shutters ( without taking off shutters from the frames) complete all as specified and directed. |
| 4 | Taking down Chowkats or frames from the opening of size exceeding 1.5 Sqmtr but not exceeding 4 Sqmtr each with shutters ( without taking off shutters from the frames) complete all as specified and directed. |
| 5 | Dismantling boarding, any description, fixed in any position with nails/screw or any type all as directed and specified directed by Engr-in-Charge. |
| 6 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc and including removal of debris and rubbish from the site complete all as specified and as directed |
| 7 | M&L for brick work with sub class \\"B\\" bricks (old size) straight or curved on plan exc 6 m mean radius, built in CM 1:6 complete all as specified and directed |
| 8 | M&L Rendering (External) 15mm thick in Cement Mortar 1:4 on Brick Walls or on Concrete Surfaces, mixing WPC as per manufacturers instructions, Plastered Surfaces finished Fair and Even, complete all as specified and as directed.NOTE: WPC will be Measured and Paid under appropriate Item. Area includes in this items upto 4 stories of building. |
| 9 | M&L for rendering 15 mm thick on brick work or concrete surfaces on walls in CM 1:6 finishing even and smooth without using extra cement complete all as specified and directed. |
| 10 | Supply only integral water proofing compound. |
| 11 | M&L for 25mm thick PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in floor finishing complete all as specified and directed |
| 12 | M&L for non-skid tiles ceramic coloured tiles 7 to 8 mm thick of size 400mmx400 mm as in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tiles including 15 mm thick screed bedding layers in CM (1:4) complete all as specified and as directed.NOTE : Cost of Cement Screed Bed shall deem to be include in the Quoted Unit Rate. |
| 13 | M&L for one way reflective toughened glass 10mm thickness and its fitting as required including stainless steel L connector 75mm wide on bothside with PVC acrylic sheet inside and fixing with SS 304 grade screw as required and Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with SS 304 grade cover, governing pivot made of brass, other parts made of mild steel heavy duty , SS 304 grade D type circular handle of 450mm length and 25mm dia with locking arrangement of SS 304 grade lock, self closing hydarulic stainless steel 304 grade top/bottom patch with pivot and self adhessive film for complete all as specifed and as directed by Engr -in-Charge |
| 14 | M&L for 2mm thick birla white putty and making the surface smooth etc complete as specified and directed |
| 15 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces including preparing old Decorated/Treated Plastered surfaces of Walls by Complete Removal of existing Treatment and by applying 2mm thick plaster of paris Wall Putty, cutting/ rubbing to obtained a Smooth Surface complete all as specified and as directed. |
| 16 | M&L Machine cut kota stone slab flooring 18-20mm thick over including 15 mm thick screed bedding layers in CM (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding,rubbing and polishing complete all as directed by Engr-in-Charge. |
| 17 | M&L Kota stone slab 18-20mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with |
| 18 | M&L Steel Work in Tubular Trusses including Special shaped Washer etc. complete using ERW or Induction Butt Welded Tubes, confirming to IS-1161-1979 Grade-240, complete all as specified and as directed. |
| 19 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 20 | S&F for PVC fluted panel wall Panneling printed in any colour PVC sheet inclusive of solvent cement and fixing at site on PVC Frame as per specification complete all as specified and as directed.Note : Design /Pattern will be selected by GE/Engr-in-Charge. |
| 21 | S&F Stainless Steel Curtain Rod 25mm dia/bore (as approved) including fixing stainless steel Bracket(shaped as approved) not less than 80mm long to wall with Screws/ secured with stainless steel side doom(as approved) fitted/tightened on Curtain Rod at both ends with screw including taking down old curtain rod of any description, complete all as specified and as directed. Note :- All asspecified and directed by Engr-in-Charge |
| 22 | M&L 20mm thick high density anti slip, non toxic EVA gym mat interlocking gym flooring rubber tiles any shape, colour and size matt finish ( As per approval of GE ) with required addisive for fixing the matt all as directed and specified by Engr-in-charge.Note :- All asspecified and directed by Engr-in-Charge |
| 23 | M&L for preparation of new surface of any description and applying two coats of synthetic enamelled paint over a coat of red oxide primer on steel surface over 10cm width or girth complete all as specifed. |
| 24 | M&L post all repair works, treating the surface to remove all loosely adhered particles floowed by washing with plenty of water using wire brush or pressure washer to ensure through cleaning. Providing and applying with 3 coats of birla Opus Prime B70 elastomeric water proofing liquid applied membrane which is formulated with elastic crosslinking mechanism of polymer and axrylic fibres having crack bridging ability of upto 2mm, tensile strength of 1.8mpa, 250% elongation and can withstand upto 10 bars hydrostatic pressure. The coating also provides with anti carbonation properties and ensure surface temprature reductions upto 10*C. Coating to ensurte a forced coverage of 10 sq ft/ltr in 3 coats on terrace and horizontal surfaces having 33% water dilution in 1st coat and an unndiluted 2 coats as per manufacturers specification having a warranty for 10 years.Note : All as per direction by Engr-in-Charge. |
| 25 | S&F GI Powder coated GI Snap Grid Frame Work of size 605x605mm as in False Ceiling with supported hanging of Mild Steel Rod of 'J' Bolt, including dismantling complete all as specified and as directed. |
| 26 | M&L for 12 mm thick perforated particle board/ tiles for insulation and accoustic purposes, 60x60 cm in size,fixed with nails or with staple in ceiling/ timber frame complete all as specified. |
| 27 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces including preparing old Decorated/Treated Plastered surfaces of Walls by Complete Removal of existing Treatment and by applying 2mm thick plaster of paris Wall Putty, cutting/ rubbing to obtained a Smooth Surface complete all as specified and as directed. |
| 28 | S&F 10mm thick sports flooring long rubber tiles for Gym, any size and any type black colour with blue/green EPDM complete all as specified and directed by Engineer-In-Charge |
| 29 | M&L for 50 mm thick GRC jali any size, any design, any pattern including fastners as required complete all as directed and specifed. |
| 30 | M&L preparation of new surface of any description and applying two coats of plastic emulsion paint over a coat of primer on concrete surface over 10cm width or girth complete all as specifed. |
| 31 | M&L18-20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite |
| 32 | S&F for PVC fluted panel wall Panneling printed in any colour PVC sheet inclusive of solvent cement and fixing at site on PVC Frame as per specification complete all as specified and as directed.Note : Design /Pattern will be selected by GE/Engr-in-Charge. |
| 33 | Excavation in post holes (or similar holes) in hard /dense soil each n exe 0.5 cu.m, gettting out, returning, filling in and ramming earth or broken rubble mixed with earth around , in layers not exeeding 25cm, watering, and removing surplus soil to a distance n exe 50 m and making good surface complete all as specified and as directed. |
| 34 | M&L for providing cement concrete (1:2:4) type B1 (using 20mm graded crushed stone aggregates) as in foundation filling and mass concrete , lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , on roofs , not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, etc including necessary formwork complete all as specified and directed by Engineer-in-Charge. |
| 35 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out soft/loose soil. |
| 36 | M&L hardcore of broken stone boulder gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface |
| 37 | M&L for 100 mm thick cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregates) as in sub base of path/roads etc complete all as specified and directed by Engineer-In-Charge |
| 38 | Forming 12 mm thick 100 mm thick concrete slab expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘B’ |
| 39 | S&F rolled sections, MS Angles, MS tubular Structures, MS Channels, Tee, etc. (Fe 410-W Gde-E-250 quality-A) as in main and cross beams, hip and jack rafters, purlins , posts,trusses (framed or unframed) structures where connected to common rafter and running rails and guides for sliding doors, fixed with angles clleats or other connecting plates all as specified. |
| 40 | M&L for preparation of new surface of any description and applying two coats of synthetic enamelled paint over a coat of red oxide primer on steel surface over 10cm width or girth complete all as specifed. |
| 41 | S&F pre-painted galvatume aluminium zinc coating GI based corrugated steel 0.50 mm thick of any colour as directed by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed by Engineer-in Charge |
| 42 | For structural of Bldg all supervison , labour, materials, equipment, tools 7 tackles required for successful completion of NDT testing/ structural audit of civil building. |
| 43 | M&L for point wiring complete with 1.5 Sqmm (nominal area) PVC insulated, multi stranded, FRLS copper conductor cable unsheathed in and including PVC conduit with all fittings medium grade ISI Marked and PVC insulated FRLS copper conductor cable of size 1.5 sq mm as earth wire, connected to common earth dolly suitable for mounting modular switches including modular metal flush boxes and modular face plate complete all as specified and as directed by Engr-in-charge, (The works includes cutting of chasis and making good disturbed surfaces and rate deemed to included in quated rate):- |
| 44 | One light/fan point controlled by one switch |
| 45 | One switch socket outlet 3 pin,5 Amp on the independent board |
| 46 | One switch socket outlet 3 pin,5 Amp on same board |
| 47 | All as per item No 44 here-in-before but with 2 single core PVC insulated FRLS and sheathed copper conductor of size 2.5 Sqmm in and including PVC conduit (ISI marked) including cutting chiseling and grouting concealed PVC conduit pipe, tee, elbow and bend etc.and with all connecting accessories with 2.5 Sqmm PVC insulated FRLS copper conductor as earth wire and connecting to common earth dolly for 6 pin 16 Amp socket outlet on the independent board.using 2.5 sqmm copper cable incl PVC insulated copeer conductor 1.5 Sqmm as continued earth wire .(Make of cable :- Finolex/ Polycab/ Havells ) |
| 48 | All as per item No 44 here-in-before but with 2 single core PVC insulated FRLS and sheathed copper conductor of size 4.0 Sqmm in and including PVC conduit (ISI marked) including cutting chiseling and grouting concealed PVC conduit pipe, tee, elbow and bend etc.and with all connecting accessories with 4.0 Sqmm PVC insulated FRLS copper conductor as earth wire and connecting to common earth dolly for 6 pin 16 Amp socket outlet on the independent board. (Make :Finolex/ Polycab/ Havells ) |
| 49 | S&F modular socket outlet 6A, 2/3 pin combined 2 module, complete all as specified and as directed by Engineer-in-Charge. |
| 50 | S&F modular socket outlet 16A, 2/3 pin combined 2 module, complete all as specified and as directed by Engineer-in-Charge. |
| 51 | S&F modular switch 1 way 6 Amps 1 module, complete all as specified and as directed by Engineer-in-Charge. |
| 52 | S&F modular switch 1 way 16 Amps 1 module, complete all as specified and as directed by Engineer-in-Charge. |
| 53 | S&F ceiling rose 3 phase/PVC/ polycarbonate isolated body, complete all as specified and as directed by Engineer-in-Charge. |
| 54 | Supply and fixing LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed(Make: Havells/ Wipro / Philips) |
| 55 | S&F wall mounted fan AC Single phase, 230V of size 450mm sweep with blades and fixing anchore bolts complete all as specified and as directed. |
| 56 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed |
| 57 | S & F Bulkhead luminaire Decorative Energy saving new generation 10W LED IP65 with opal diffuser incl electronics driver & connection with copper flexible cable 3 core complete all as specified and directed.(Make: Havells/ Wipro / Philips) |
| 58 | Supply, Installation ,commissioning and testing invertor type BEE 5 star rating air cooled split unit air conditioner electric driven single phase of capacity 1.5 TR, Eco friendly refrigerant, hi wall split units indoor and outdoor unit complete with cordless remote control unit and with inbuilt air ioniser and plasma filter for better indoor air quality with 5 star rated, auto restart facility,100% copper tube and condenser including excess copper tubing if required beyond the lenght 7.5 mtrs supplied with AC unit and PVC conduit of 15mm dia not exceeding 2.5 mtr long for water drain including drilling hole through drill machine and making good to disturbed surface with cement mortar ratio 1:3 to match the existing surface complete all as specified and directed by Engineer - in-charge. Make : Daikin Cat Part No: FTK50UV16.or equivalent |
| 59 | Supply and fix Voltage stabilizer for automatic operation, single phase, copper wound naturally air cooled indoor type & designed for input variation between 150 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% suitable for 1.5 Ton AC operation complete all as specified and directed. Make Bluebird or equivalent |
| 60 | S & F LED Building security light 35 watt pressure die cast housing with individuals LEDs & Lens with modular secondary optics and IP65 protection with electronics driver and copper conductor 3 core of 1.5 sqmm from ceiling rose to security light with Bracket made out of GI light grade pipe of 32 mm dia 1.5 mtr long bend to an angle of 120 degree with fixing arrangements on wall with impact and corrosion resistant including thermalmanagement in multiple optics complete with IP 65/66 protection complete all specified and dirented. (Make: Havells/ Wipro / Philips) |
| 61 | Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp 240 volts. complete all as specified and as directed by Engineer-in-Charge. (Make:Legrand / Schneider/Havells) |
| 62 | S&F sheet metal enclosure with double door for DBs conforms to IS:8623.III , IP:43 protection, shrouded neutral bar and cement spill protector, 4 way, 415 Volt TPN complete all as specified and as directed by Engineer-in-Charge. (Make:Legrand / Schneider/Havells) |
| 63 | S&F sheet metal enclosure with double door for DBs conforms to IS:8623.III , IP:43 protection, shrouded neutral bar and cement spill protector, 8 way, 240 Volt SPN Make : Legrand /Siemens /Havells |
| 64 | S & F MCBs 'B' characteristics, TPN 63 Amp, 240 V, breaking capacity 10 kA , complete all as specified and as directed by Engineer-in-Charge. (Make:Legrand / Schneider/Havells) |
| 65 | S & F MCBs 'B' characteristics, Double pole , 240 V, 40 Amp breaking capacity 10 kA , complete all as specified and as directed by Engineer-in-Charge. (Make:Legrand / Schneider/Havells) |
| 66 | S & F MCBs 'B' characterstic single pole 5 to 30 Amp, 240 volt breaking capacity 10 kA complete all as specified and as directed by Engineer-in-Charge. (Make:Legrand / Schneider/Havells) |
| 67 | M&L for submain wiring 2 single core PVC insulated FRLS cable 6 Sqmm copper conductor PVC sheathed in and including rigid PVC concealed conduit heavy duty of suitable size incl cutting chiseling of wall and making good to disturbed surface of walls / floor etc with plastering painting etc so as to match with the existing finishes, drawn with 6 Sqmm PVC insulated FRLS copper conductor cable for earth wire fixed with shaddle and connecting to common earth teriminals complete all as specified. (Make of cable :- Finolex/ Polycab/ Havells ) |
| 68 | Earthing complete with and including galvanised steel earth plate electrode 60 cmx 60cm x 6 mm thick surrounded by mixture of charcoal and salt in alternate layers , buried directly in ground vertically in a pit of depth not less than 2.25 meter deep below ground level with top as of the plate at a depth of not less than 1.5 mtrs below normal ground level connected to galvanized iron or steel earth lead wire 4.0 mm dia,( NO 8 SWG) by means of bolts ,nuts, check nuts and washers of galvanised iron or steel earth wire protected by galvanised steel pipe 15 mm bore (light grade) and connected to main switch or main control board all as shown in electrical plate No. 3 of SSR - 2009(Pt I) & including necessary excavation and earth workThe rate also include charcoal and salt in alternate layers, 20 mm bore GI pipe (Light grade ) for watering , protection pipe funnel, wire mesh , PCC 1:2:4 type B1 chamber in cement concrete ,50 mm thick precast RCC M-25 ( Normal mix) cover duly reinforced with XPM (weight not less than 3 kg /sqm ) and CI frame etc , and including provision of test point , connecting to test point and testing on completion etc, complete all as specified. NOTE : The unit rate include earthing lead and protection pipe upto 6.5 metre from top of earth plate. . |
| 69 | Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 2mm dia galvanised iron or steel wire complete all as specified. |
| 70 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100 Volts grade aluminum conductor of size 16 sqmm 4 core (Excavation and Earth works taken separatley) |
| 71 | Excavation in trenches in hard/tense soil not exceeding 1.5 metre deep and not exceeding 1.5 metre wide and getting out including dressing / trimming sides and leveling/grading and ramming of bottom of excavation complete as sepecified and directed by Engr-in-Charge. |
| 72 | Returning, filling in including spreading, leveling, watering and well raming excavated soid in layers not exceeding 25 cm thick, filling back in trenches after cables have been laid and tested, poles, stays, struts have been erected and tested complete as sepecified and directed by Engr-in-Charge. |
| 73 | Removing of surplus soil to a distance n.exc 50 mtr and depositing at a level n.nexc 1.5 mtr above starting point where directed complete as sepecified and directed by Engr-in-Charge. |
| 74 | M&L for sand cushioning in trenches for protection of LT under ground cable including punning and consolidation complete as sepecified and directed by Engr-in-Charge. |
| 75 | Supply and Laying Bricks old size sub class 'B', of class designation 10, for the protection of cable laid flat dry across the cable complete as sepecified and directed by Engr-in-Charge.. |
| 76 | M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including GI pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as directed. Please Enable Macros to View BoQ information |