| 1 | Sh:- Parking Place |
| 2 | Carriage of Excavated Earth from quary site of work by mechanical Transport in cluding loading unloading and dressing complete |
| 3 | Earth work in excavation in foundation trenches not exceeding 1.50 m width or 10 Sq.m. on plan or drains not exceeding 1.50 m in width or 10 Sq.m. on plan including dressing of sides and ramming of bottoms, lift upto 1.50 m including getting out the excavated earth. a) Hard Soil |
| 4 | Providing and laying in foundations and plinth cement concrete 1 : 5 : 10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 5 | Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering i in Foundation and plinth. |
| 6 | Chequered terrazzo tiles 22 mm thick with marble chips of sizes upto 6mm in floors on 25 mm thick bed mortar 1 : 3 (1 cement : 3 coarse sand) jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polish in Dark shade Using ordinary cement. |
| 7 | Add Carriage |
| 8 | SH- RCC Retaining Wall 5mtr Height |
| 9 | Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more tha |
| 10 | Providing and laying in foundations and plinth cement concrete 1:5:10 ( 1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 11 | Providing and laying in foundations and plinth cement concrete 1 : 2 : 4(1 cement : 2coarse sand : 4graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 12 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : |
| 13 | Reinforced cement concrete in walls (any thickness) including attached pilasters, buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring,shuttering and reinforcement in - a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size) |
| 14 | Reinforcement of RCC work including bending, binding and placing in position complete. b) Tar/ TMT steel |
| 15 | Centring and shuttering including strutting proping etc. and removal of form work for:a) Foundation, footings, bases of columns etc. and mass concrete. |
| 16 | b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 17 | Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications |
| 18 | Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification A) Granular material |
| 19 | Carriage of material |
| 20 | SH- Boundary Wall |
| 21 | Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30cm size , saturated soil and rock), lift upto 1.5 m and stacking the excavated soil not more than 3m clear from the edge of the excavation andf returning the stacked soil in 15 cm layers, when required, into plinth sides of foundation etc. consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50 m. |
| 22 | Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete. |
| 23 | Providing and laying cement concrete 1:4:8 (1 cement:4 course sand: 8 graded stone, aggregate 40mm nominal excluding the cost of centering and shuttering a) Foundation and plinth |
| 24 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering inb) Walls i/c attached buttress.. |
| 25 | Reinforcement of RCC work including bending, binding and placing in position complete. |
| 26 | Centring and shuttering including strutting, propping etc and removal of form work for :a) Foundation, footings, bases of columns etc. and mass concretea) Foundation, footings, bases of columns etc. and mass concrete |
| 27 | b) Walls i/c attached buttress.. |
| 28 | e) Column, pillars, posts and struts etc. |
| 29 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in :b) 1 : 1.5 : 3 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size). |
| 30 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 ement : 3 fine sand) of thickness not exceeding 6 mm to a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 31 | Brick work with best available local bricks in foundations and plinth in cement mortar 1:6 (1 cement : 6 fine sand). |
| 32 | Half brick masonry (with best available local bricks) in cement mortar 1:4 (1cement : 4 coarse sand) in foundation and plinth. |
| 33 | Extra for half brick masonry in superstructure above plinth level and up to floor two level. |
| 34 | 20 mm cement plaster 1 : 4 (1 cement : 4 fine sand). |
| 35 | Applying one coat of cement primer of approved brand and manufacture on wall surface |
| 36 | Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade. |
| 37 | Add. Carrying charge |
| 38 | TOILET BLOCK |
| 39 | Earth work in excavation in soils containing 50% or more of shingle or small size boulders upto 30 cm size including banking in 20 cm layers and breaking clods, ramming and dressing up for the purpose of making embankments or filling up ground depressions lead upto 50 m and lift upto 1.50 m. |
| 40 | Providing and laying in foundations and plinth cement concrete 1 : 5 : 10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 41 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in :b) 1 : 1,5 : 3 (1 cement : 1 .5coarse sand : 3 stone aggregate 20 mm nominal size). |
| 42 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.b) 1 : 1,5 : 3 (1 cement : 1 .5coarse sand : 3 stone aggregate 20 mm nominal size). |
| 43 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.b) 1 : 1,5 : 3 (1 cement : 1 .5coarse sand : 3 stone aggregate 20 mm nominal size). |
| 44 | Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand). |
| 45 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
| 46 | Reinforced cement concrete work in shelves up to floor two level excluding cost of centering and shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size). |
| 47 | Centring and shuttring including strutting, proping etc. and removel of form work etc complete.a) Foundation, footings, bases of columns etc. and mass concrete. |
| 48 | e) Column, pillars, posts and struts etc. |
| 49 | c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). |
| 50 | d) Lintels, beams, girders, bressumers and cantilevers etc. |
| 51 | Reinforcement in RCC work including bending, binding and placing in position etc complete.b) Cold twisted bars |
| 52 | Brick work with best available local bricks in foundation and plinth in cement mortar 1:4 (1 cement : 4 fine sand). |
| 53 | Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position. |
| 54 | Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including aluminium butt hinges with necessary screws.a) 38 mm thick best available local wood class- B I |
| 55 | Providing and fixing louvers 50 mm wide in groove in clerestory window frames but excluding cost of frames.c) Glass sheet of 3 mm thick |
| 56 | Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal size). |
| 57 | Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws.b) Ornamental grill |
| 58 | Providing and fixing aluminum butt hinges anodised, transparent or dyed to required color or shade with necessary screws etc complete.d) 100 x 63 x 4 mm |
| 59 | f) 75 x 63 x 4 mm |
| 60 | Providing and fixing MS Hooks and Eyes.c) 200 mm |
| 61 | Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessary screws etc complete.a) 300 x 10 mm |
| 62 | c) 150 x 10 mm |
| 63 | Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete.a) 125 mm |
| 64 | b) 100 mm |
| 65 | c) 75 mm |
| 66 | Steel work riveted or bolted in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of red lead paint.a) In RS Joists |
| 67 | Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 68 | 25 mm thick cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) finished with a floating coat of neat cement. |
| 69 | Providing and laying damp proof course 25 mm thick with cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm nominal size). |
| 70 | Pre-cast terrazzo tiles 20 mm thick with white, black or white and black marble chips of sizes up to 6 mm laid in floor, treads of steps and landings on 25 mm thick bed of cement mortar 1 : 3 (1 cement : 3 coarse sand) jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete with pre-cast tiles of :a) Light shade using white cement |
| 71 | 12 mm cement plaster 1 : 3 (1 cement : 3 fine sand). |
| 72 | Wall painting (two or coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade. |
| 73 | Appling priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete. |
| 74 | Painting (one or more coats) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade. |
| 75 | Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work).a) 15 mm nominal bore |
| 76 | Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required.a) Flat back wash basin size 550x400 mm with a pair of 15 mm CP brass pillar taps of heavy quality. |
| 77 | Providing corrugated G.I.sheet roofing fixed with galvanised iron J or L hooks, bolts & nuts 8 mm dia with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete, excluding the cost of purlins, rafters and trusses.b) 0.80 mm thick GI sheet |
| 78 | Providing ridges or hips 60 cm overall in plain G.I. sheet fixed with galvanised iron J or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. b) 0.63 mm thick GI sheet |
| 79 | Providing best available local wood (Class - B II) work in frames of false ceiling, partitions and trusses etc, sawn and put up in position. |
| 80 | Providing and fixing 4.0 mm thick asbestors plain sheet ceiling of approved quality with necessary nails etc.complete (frame work for base to be paid separately). |
| 81 | White washing with lime on new work (two or more coats) to give an even shade. |
| 82 | Providing and fixing plain, square edged wooden beading 38 mm x 12 mm section with screws of approved quality for ceiling.a) Best local approved quality wood. |
| 83 | Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth. |
| 84 | Construction of cement concrete drain 15 cm wide and 15 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips or shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering and all exposed surfaces with 12 mm thick cement mortar 1 : 3 (1 cement : 3 coarse sand) including shuttering complete. |
| 85 | Providing and fixing kitchen sink including making all connection excluding cost of fittings.a) White glazed fire clay sink size 600x450x150 mm |
| 86 | Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleadt with CP brass screws and washers. |
| 87 | Providing and fixing 600 x 120 mm glass shelf with CP brass brackets and guard rail complete, fixed to wooden cleadts with CP brass screws. |
| 88 | Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work).b) 20 mm nominal bore |
| 89 | Providing and fixing brass bib cock of approved qualitya) 15 mm nominal bore |
| 90 | Providing and fixing brass stop cock of approved qualityb) 20 mm nominal bore |
| 91 | Providing and fixing soft wood 'EVE' board 25 mm thick and 225 mm wide including painting two coats complete as directed. |
| 92 | Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanized steel telescopic flush pipe with fittings and clamps 20 mm GI over flow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting and making good the walls and floors where required.a) Long Pan patten WC Pan |
| 93 | Add Carriage Please Enable Macros to View BoQ information |