| 1 | Civil Works |
| 2 | Clearing compound premises of shurbs, plants, jungles etc. by cutting and removing as directed (Specific permission of Engineer-in-Charge prior to execution will be necessary). (Payment to be made on area cleared) |
| 3 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm |
| 4 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)(a) With earth obtained from excavation of foundation. |
| 5 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 6 | Labour for Chipping of concrete surface before taking up Plastering work. |
| 7 | Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches. |
| 8 | Brick work with 1st class bricks in cement mortar (1:6)(a) In foundation and plinth |
| 9 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. |
| 10 | (i) Pakur Variety. |
| 11 | (I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor(A) [Pakur Variety] |
| 12 | (a) 1:3:6 proportion. |
| 13 | Labour for boring through any type of soil for sinking tube well of required dia. with top enlargement by rig boring system (either by reserve circulation or by direct rotary method) including hire charges and labour for rig machine, tools and plants, staging, force pumping set and making arrangement for water required for boring etc. complete and lowering of pipes, strainers, blind pipes etc. complete(a) For depth upto 250 metre for 100 mm dia. Tube well with top enlargement of 200 mm dia.(upto 50 metre). |
| 14 | (i) First 50 metre |
| 15 | (ii) Next 50 Metre |
| 16 | (iii) Next 50 Metre |
| 17 | (iv) Rest 100 Metre |
| 18 | Geophysical investigation of the acquifer by electrologging system with all tools and plants as necessary including supply of necessary report. |
| 19 | Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer-in-charge including cost of all materials labour and equipment complete. |
| 20 | Packing annular space between the outside of the housing pipe and the bore with puddled clay balls of approved size as per direction of the Engineer-in-charge with cost of all materials and labour complete. |
| 21 | Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labourcharges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction. |
| 22 | Labour for making arrangement for showing verticality test including the cost for hire charges of tools and plants, scafolding, labour etc. all complete. |
| 23 | Supplying high density polythene strainer of approved make with adapter conforming to I.S. specifications.For 100 mm dia |
| 24 | Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (A) PVC Pipes (Dia) |
| 25 | for 100 mm dia |
| 26 | for 200 mm dia |
| 27 | Supplying, fitting and fixing steel cutter piece upto 450 mm long with sockets. For 75 mm dia |
| 28 | Supplying, fitting and fixing heavy type bell mouth reducing socket for 100mm X 200 mm dia pipe |
| 29 | Supplying, fitting and fixing G.I. cap at top for 200 mm dia |
| 30 | Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239(Part - I).(A) PVC Pipes(L) Reducing Socket (mm X mm)100 X 80 |
| 31 | Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I).(A) PVC Pipes(Dia)80 mm |
| 32 | Supplying, fitting and fixing PVC pipes for underground work ofapproved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes,making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.) PVC Pipes(Dia) |
| 33 | 80 mm |
| 34 | 50 mm |
| 35 | Distribution wiring in 1.1 KV single core stranded 'FR'PVC insulated & unsheathed copper wire (Brandapproved by EIC) in 20mm size PVC rigid conduit 'FR'(Precision make) incl. necy. fittings as required 3 x 84/0.3 (6 sqmm) + 2 x 56/0.3 (4 sqmm) ECC |
| 36 | Supplying and fixing 4 way MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment, incl.supply anf fixing 1no. Legrand make 6-32A, 240/415 V TP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. Make - Legrant |
| 37 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts.long and 1 x 4 SWG ISI Medium GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: PWD-G-1/2A |
| 38 | Supply and Lowering of \\"KSB\\" MAKE BPD 262/5A+UMA 150 - 5 HP, 5 Stage, 3 Phase BOREWELL SUBMERSIBLE PUMP MOTOR SET Motor Type :3/22, 2900 RPM, 440 VOLT, 3 PHASE MOTOR WITH 3 MTR LEAD CABLE.DISCHARGE 5,9,10,11,14 m3/hr AT HEAD 47,40,38,35,25m. |
| 39 | Supply & Fixing LTLK make 415V, 3 phase (D.O.L) Starter type MU-1A DOL(with Sz5 SPPR) Cat no-CS90898COAO having relay (7-12A) (L&T make) on angel iron frame suitable for operation of 7 H.P. Submersible Pump motor set with necessary connection.(M.R) NB: Sz5 is a single phasing preventor. |
| 40 | Supply of 4 core 16 Sqmm XLPE/PVC insulated Aluminium armoured cable polycab/Mescab/Kei/Bonton Make |
| 41 | Laying of cable upto 35 Sqmm. in underground trench 460 mm wide x 760 mm average deapth , with brick protection on the top of the cable with 8 (eight) nos bricks per meter , including filling the space between the brick & cabile and also the trench with sifteed soil, leveling up and restoring surface duly rammed |
| 42 | Supply of 3 core,2.5 Sqmm dia Submersible Cable(polycab/Mescab/Kei/Bonton make) (M.R) |
| 43 | Supply and fixing 1no. Single wooden board.having size 2 ft X 2 ft[M.R] |
| 44 | Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)(a) For Exposed Work PVC Pipes |
| 45 | 40 mm |
| 46 | 80 mm |
| 47 | 15 mm |
| 48 | Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.).(v) 40 mm dia |
| 49 | Taxes & Duties |
| 50 | Add: G.S.T. @ 18% of Rs.32,59,201.=90 ( sum of Sl. No. 1.01 to 1.47) i.e. Rs. 5,86,656.34 |
| 51 | Add: Labour Cess @ 1% of Rs. 38,45,858=24 (sum of Sl. No. 1.01 to 2.01) i.e. Rs. 38,458=58 Please Enable Macros to View BoQ information |