| 1 | Hire and Labour charges for supply, fixing and dismantling of 4’40W Patty Tube Light with Fitting on existing supports. |
| 2 | Hire and Labour charges for maintaining of 4'20W tube light fitting. |
| 3 | Hire and Labour charges for supply, fixing and dismantling of 200W LED Flood Light fitting with suitable cross arm on existing support. |
| 4 | Hire and Labour charges for maintaining of 200W LED Flood Light fitting. |
| 5 | Hire and Labour charges for supply, fixing, and dismantling of Pedestal fan. |
| 6 | Hire and Labour charges for maintaining of Pedestal fan. |
| 7 | Hire and Labour charges for supply, fixing and dismantling of Aircooler with stand complete with all connections (One trial day, one starting day & last day dismantling) |
| 8 | Hire and Labour charges for maintaining of Aircooler. |
| 9 | Hire and labour charges for supply, fixing and dismantling of 1.5 TR Split type AC unit complete with all accessories and connection (One trial day, one starting day & last day dismantling) |
| 10 | Hire and Labour charges for maintaining 1.5TR split type AC unit |
| 11 | Hire and labour charges for supply, fixing and dismantling of 2.0 TR Split type AC unit complete with all accessories and connection (One trial day, one starting day & last day dismantling) |
| 12 | Hire and Labour charges for maintaining 2.0TR split type AC unit |
| 13 | Hire labour charges for supply, fixing and dismantling of 5.0 TR Slim Package AC complete with all accessories and connection. |
| 14 | Hire and Labour charges for maintaining of 5.0 TR Slim Package AC. |
| 15 | Hire and labour charges for supply, fixing and dismantling of 3nos 5A plug board. |
| 16 | Hire and Labour charges for maintaining from of 3nos 5A plug board. |
| 17 | Hire and labour charges for supply, fixing and dismantling of 15A/ 5A plug board. |
| 18 | Hire and Labour charges for maintaining of 15A/ 5A plug board. |
| 19 | Hire and Labour charges for supply, fixing, maintenance and dismantling of 6 Mtrs height GI pole as support for fixing focus light fitting. |
| 20 | Hire and Labour charges for maintaining from of 6 Mtrs height GI pole. |
| 21 | Hire and Labour charges for supply, installation and dismantling of 32A 8 way SPN Distribution board complete with 1No 32A DP MCB as incoming with 6Nos 6-32A MCB as out going with necessary connection. |
| 22 | Hire and Labour charges for maintaining of 32A 8way SPN Distribution board. |
| 23 | Hire and Labour charges for supply, installation and dismantling of 63A 12 way Horizontal Distribution board complete with 1No 63A isolator as incoming with 12Nos 6-32A MCB as out going with necessary connection. |
| 24 | Hire and Labour charges for maintaining 63A 12 way Horizontal Distribution board. |
| 25 | Hire and Labour charges for supply, installation and dismantling of 200A Pedastal panel board complete with 1No 200A TPN switch with 2Nos 32A 6Nos 63A TPN switch with indicator and necessary connection. |
| 26 | Hire and Labour charges for maintaining of 200A Pedastal panel board. |
| 27 | Hire and labour charges for supply, fixing and dismantling of 250A change over switch with connection. |
| 28 | Hire and Labour charges for maintaining of 250A change over switch. |
| 29 | Hire , labour charges and maintenance of 250A Capacity ATS Panel board made up of 16SWG Sheet steel for outer boby with doors,switch supports and separations etc.. and with supply and fixing of the following interior mounting switch with bus bar chmber complete with 25 x 12mm aluminum bus bar complete for 3phase and neutral interior connection to 250A incoming SDF from the bus bar and 25x12mm aluminum bus bar complete for interior connection to 250A SDFwith suitable sleeves and hylum separators 1No 25x6mm aluminum earth bus run, all round the panel to rovide double earth connection to all incoming and outgoing SDF from the earth above earth bus including and indication lamps complete. connections etc. as per IE rules and CEIG specifications. |
| 30 | Hire charges for DP Surge protective Device with necessary connections complete |
| 31 | Alteration in existing 125/ 62.5 KVA Genset for installation of GENSET ON/ OFF control relays and Timer arrangement with necessary Panel wiring & Interconnection wiring and testing complete |
| 32 | Hire and Labour charges for supply, run off and dismantling of 3 of 2.5 Sqmm copper wire in suitable PVC rigid pipe(One trial day, one starting day & last day dismantling) |
| 33 | Hire and Labour charges for maintaining 3 of 2.5 Sqmm copper wire |
| 34 | Hire and Labour charges for supply, run off and dismantling of 2x3/20 PVC copper wires on suitable PVC rigid pipe. |
| 35 | Hire and Labour charges for maintaining of 2x3/20 PVC copper wires. |
| 36 | Hire and Labour charges for supply, run off and dismantling of 2x7/20 PVC copper wires on bearer wire. |
| 37 | Hire and Labour charges for maintaining of 2X7/20 PVC copper wires. |
| 38 | Hire and Labour charges for supply, run off and dismantling of 4 X 7/20 PVC copper wires on bearer wire. |
| 39 | Hire and Labour charges for maintaining of 4 x 7/20 PVC copper wires. |
| 40 | Hire and Labour charges for supply, run off and dismantling of 4 x 7/16 sqmm copper cable complete. |
| 41 | Hire and Labour charges for maintaining of 4 x 7/16 sqmm copper cable. |
| 42 | Hire and Labour charges for supply, run off and dismantling of 4 x 19/16 sqmm copper cable complete. |
| 43 | Hire and Labour charges for maintaining of 4 x 19/16 sqmm copper cable. |
| 44 | Hire and Labour charges for supply, run off and dismantling of 3½ X 50 sqmm LTUG armoured cable (One trial day, one starting day & last day dismantling) |
| 45 | Hire and Labour charges for maintaining 3½ X 50 sqmm LTUG armoured cable |
| 46 | Hire and Labour charges for supply, run off and dismantling of 3½ x 70 sqmm LTUG armoured cable. |
| 47 | Hire and Labour charges for maintaining of 3½ x 70 sqmm LTUG armoured cable. |
| 48 | Hire and Labour charges for supply, run off and dismantling of 4 x 120 sqmm LTUG armoured cable.(One trial day,one starting day & last day dismanting) |
| 49 | Hire and Labour charges for maintaining of 4 x 120 sqmm LTUG armoured cable. |
| 50 | Hire and Labour charges for supply, run off and dismantling of 3½ x 180 sqmm LTUG armoured cable. |
| 51 | Hire and Labour charges for maintaining of 3½ x 180 sqmm LTUG armoured cable. |
| 52 | Hire and labour charges for supply, fixing operating and dismantling of 125KVA Diesel Generator set Excluding Diesel and with Operator charges. |
| 53 | Hire and Labour charges for maintaining of 125kVA Genset in Intermediate days. |
| 54 | Hire and labour charges for supply, installation and dismantling of earth with GI piping earth wires and with watering etc., |
| 55 | Hire and Labour charges for maintaining of earth with GI piping earth wires. |
| 56 | Hire and labour charges for supply, fixing of and dismantling of public address system- A with necessary mic-2 Nos Amplifier-1No and speaker - 2Nos etc., on the counting day for annocements. |
| 57 | Hire and Labour charges for maintaining of public address system- A. |
| 58 | Hire and labour charges for supply and assembling testing and dismantling of public address system- B for the following items (1)Stand mike-2, (2)Cardless mike-2, (3)Amplifier-4, (4)4 X 12 Speaker box-10Nos etc., on the counting day for announcements including wiring arrangements. |
| 59 | Hire labour charges for supply and fixing of 5000VA (12V/DC) electrical inverter with 6Nos 12V 150AH tubular battery with 1hour back up on full load operation for mentioned capacity. |
| 60 | Hire and Labour charges for maintaining of 5000VA (12V/DC) electrical inverter. |
| 61 | Hire labour charges for installation and dismandling charges for 55 inch LED TV with proper stand arrangements including necessary Dish arrangements. |
| 62 | Hire and Labour charges for maintaining of 55 inch LED TV with proper stand arrangements including necessary Dish arrangements. |
| 63 | Hire and labour charges for 3 phase submeter with CT coil arrangement with all electrical connections etc. |
| 64 | Hire and labour charges for providing and dismantling of temporary GI sheet shed for protecting panel boards. |
| 65 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with Module Plastic surface mounting box on wall with 6A one way module switch with module front plate with painting of Suitable colour for Open PVC Light point/ fan point (for electronic regulator) 5 points/ coils Higher End |
| 66 | Towards Removing and refixing of 4'20W LED Tube Light in the existing tube light fitting. |
| 67 | Towards Removing and refixing of 3nos. 6A Computer Plug in the exististing Modular Box with necessary connections. |
| 68 | Towards Removing and refixing of 16A Power Plug in the exististing Modular Box with necessary connections. |
| 69 | Dismantling and refixing of existing AC ceiling fans in the Class rooms in complete. |
| 70 | Dismantling and refixing of existing network cables in the computer room and labs in complete. |
| 71 | MAINTENANCE WORK Towards Engaging of contract labours for attending fuse of calls maintaining the existing EI and power mains and uninterupted power supply round the clock in The Vivekanandha College of Technology for Women campus. |
| 72 | Charges for supply, conveyance, filling of fuel to the Diesel Generator sets provided for all the days of use in The Vivekanandha College of Technology for Women campus. |
| 73 | GST 18% Please Enable Macros to View BoQ information |