| 1 | CONSTRUCTION OF PUMP HOUSE & TUBEWELL AT DISTT JAIL BARABANKI, IN DISTRICT - BARABANKI (U.P.) |
| 2 | Transportation of heavy rig machine job. |
| 3 | ERECTION AND DISMANTLING OF RIGMACHINE. |
| 4 | Water suply charge and driling machine. |
| 5 | Drilling 200MM dia bore hole in alluvium other than rock, sand stone & boulder formations:from G.L. to 350 M. |
| 6 | Reaming of 200 MM dia pilot bore to 500 MMdia bore: from 150 M to 400 M. |
| 7 | Washing of bore hole. |
| 8 | Electric loging of bore hole. |
| 9 | Providing & lowering of assembly pipe including cutting & welding by providing a collar: |
| 10 | 300 MM dfa MS ERW Housing pipe having wallthickness 7 MM. |
| 11 | 200 MM dia MS ERW Housing pipe having wallthickness 6 MM. |
| 12 | 200 MM dia MS ERW Slotted pipe. |
| 13 | Providing and fixing Well Cap, Reducer, Clamp,Centre Guide & Bail Plug. |
| 14 | Providing and Packing the bore hole withsuitable size of pea gravel. |
| 15 | Development by high velocity jetting toughterwith Air Compressor |
| 16 | Transportation of air compressor |
| 17 | Erection of Air Compressor |
| 18 | Runing of Air Compressor |
| 19 | Development Of Tubewell by O.P. Unit. |
| 20 | Transportation of O.P. Unit. |
| 21 | Erection of O.P. UNIT |
| 22 | Development Of Tubewell by O.P. Unit |
| 23 | Water testing chemical and bactriological |
| 24 | Supply and installation of 10Hp submersablepump complete. |
| 25 | Electrical work |
| 26 | Point wiring in PVC couduit, with piano type switch:- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular type switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A |
| 27 | Circuit / Sub main wiring in PVC conduit:- Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. |
| 28 | 2 X 1.5 sq. mm +1 x 1.5 sq. mm earth wire. |
| 29 | 2 X 2.5 sq.mm. + 1 X 2.5 sq. mm earth wire. |
| 30 | 2 x 6 sq. mm +1 x 6 sq. mm Earth wire. |
| 31 | S/ F light plug point piano type accessories:- Supplying and fixing metal box of 150 mm X 75 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. |
| 32 | S/f modular type blanking plate:- Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 33 | Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required : |
| 34 | Supplying and fixing 5 amps. To 32 amps. Rating 240 volts 'C' series, miniature circuit breaker (MCB) suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. single pole |
| 35 | Supplying and fixing single pole, blanking plate in the existing MCB DB complete etc. as required. |
| 36 | S/F DP MCB Isolator Supplying and fixing following rating, double pole, 240V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. 40 Amps |
| 37 | Supplying and fixing following way, SP&N, sheet steel, MCB distribution board, 240 V on surface / recess, complete with tinned copper bus bar, netural bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB/ Isolator) 6 way, Double door |
| 38 | Earthing with GI earth plate 600mm X 600mm thick including accessories and providing masonary enclosure wuth cover plate having locking arrangement and watering pipe of 2.7 meter long etc, with charcoal/ coke and salt as required. |
| 39 | Supplying and lying 25mm X 5mm. G.I. strip at 0.50 meter below ground as strip earth electrode, including connection/ termination with G.I. nut, bolt, spring, washer etc. as required. (ajaointing shall be done by overlapping and with 2 sets of g.i. nut bolt & spring washer spaced at 50mm) |
| 40 | Providong and fixing 25 mm x 5 mm G.I. strip in 40mm dia G.I. pipe from each electrode including connection with G.I. nut, bolt, spring. washer excavation and re-filling etc. as required. |
| 41 | Providong and fixing 25mm x 5mm G.I. strip on surface on in recess for connections etc. as required. |
| 42 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 43 | Providing and fixing M.V. danger notice plate of 200mmx150mm made of mild steel, atleast 2mm thick and vitreous enamelled white on both sides and with inscription single red colour on FRLSont side as required. |
| 44 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 45 | 5/6 A switch |
| 46 | 3 pin 5/6 socket outlet |
| 47 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm) |
| 48 | Installation, testing and commissioning of pre-wired, flourescent fitting / compact flourescent fitting of all types,complete with all accessories and tube etc. directly on ceiling / wall, including connections with 1.5 sq. mm. FRLS PVC insuated, copper conductor, single core cable and earthing etc. as required. |
| 49 | Suply of recess/surface mounting round 10 W to W LED Cit out Min 125mm, Height Min. 40mm, LED Down lighiter having powder coated die cast aluminium housing with heat shink, diffuser/reflector and driver set suitable for 24hr Continuous Operation, Complete in all respect. |
| 50 | Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channek Base with bottom and top cable entreis Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release) Switches Complete and instru,ent camber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering sysytem for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different reading, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alimininum busbars as per IS8623 or above istulated with hear shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with detaachable side cover and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable and boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directiond of Engineer-in-charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type board shall be of cart A & B Only. |
| 51 | 63Amp. MCCB-3 No. Cat. -B. PannelCubicle Type |
| 52 | OR outgoing as per site requirment(AS/SLD) |
| 53 | Pump Room |
| 54 | Earth work in excavation in foundation soil (lime clay or sand) lead up to 30m and lift up to 1.5m and including filling,watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur plus earth as directed by the enginerr incharge up to a distance of 30 meters from the foundation trenches |
| 55 | Supplying and filling in plinth with Jamuna sand under floors, including watering, ramming, consolidating and dressing complete. |
| 56 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stoneaggregate 40 mm nominal size). |
| 57 | Diluting and injecting chemical emulsion for POST- CONSTRUCTIONAL anti- termite treatment (excludingthe cost of chemical emulsion) : Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete: Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : With Chlorpyriphos/Lindane E.C. 20% with 1%concentration. |
| 58 | RCC Works |
| 59 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) Plinth Beam |
| 60 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). |
| 61 | PLINTH BEAM |
| 62 | SLAB BEAM |
| 63 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 64 | providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per sqm on DPC after cleaning the surface with brushes and finnally with apiece of cloth lighty soaked in kerosene oil. |
| 65 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) 2.25FM |
| 66 | GROUND FLOOR TO TERRACE FLOOR |
| 67 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 68 | GROUND FLOOR TO TERRACE FLOOR |
| 69 | P/F mild stell or iron in plain work such as reinfroced cocrete or reinfored brick work wrought to required shape as necessary including bending for proper completion of the work and including supply of stell its wastage bend hooks and authorised over lapping shall be measured upto floor two level |
| 70 | UPTO PLINTH |
| 71 | GROUND FLOOR TO TERRACE FLOOR |
| 72 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) |
| 73 | 14 mm cement plaster On rough side of single or half brick wall of mix Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 74 | Froming groove of uniform size from 12*12 mm and uoto 25*15 mm in the top layer of washed stone grit plastered surface as per approved pattern, including providing and fixing aluminum channel of appropriate size and thickness (not less than 2 mm) nailed to the under layer with rust proof screw and nails and finishing the groove complete 40mm thick with 20mm nominal size aggregate |
| 75 | C.C. flooring 1:2:4 finished with a floating cost of neat cement including cement slurry but excluding the cost of nosing of step etc complete 40mm thick with 20mm nominal size aggregate |
| 76 | Wood Works |
| 77 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters : 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 78 | both side laminated |
| 79 | Providing and fixing angle iron frames for doors , windows and ventilators of mild steel angle section of size 35x35x5 mm joints mitted and welded angle iron 35x35x5 mm or 35x5 mm flat pieces to the existing T- Iron frame or to the wall with dash fastner including fixing of necessory butt hinges and screws and applying a priming coat of approved steel primer all complete as per the direction of Engineer-Incharge . |
| 80 | In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works. |
| 81 | z section stell window openable |
| 82 | Providing and fixing angle iron frames for doors , windows and ventilators of mild steel angle section of size 35x35x5 mm joints mitted and welded angle iron 35x35x5 mm or 35x5 mm flat pieces to the existing T- Iron frame or to the wall with dash fastner including fixing of necessory butt hinges and screws and applying a priming coat of approved steel primer all complete as per the direction of Engineer-Incharge . 40*40*5 |
| 83 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade. New work (two or more coats) over and including water thinnable priming coat with cement primer having VOCcontent less than 50 gram per litre |
| 84 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primerapplied @ 2.20 kg/10 sqm). |
| 85 | Providing and applying white based putty of average thickness 1mm of approved brand and manufacturer,over the plastered wall surface to prepare the surface even and smooth complete |
| 86 | Providing and fixing 150mm bright finished floor brass door stopper with rubber cushion necessary brassscrews etc to suit shutter thickness complete |
| 87 | Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a)250mm x 16mm. |
| 88 | Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. (a) 250 x 10mm (a) 250 mm x 10mm |
| 89 | Providing and fixing stainless steel handles with screws etc. complete (a) 125 mm |
| 90 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture |
| 91 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture |
| 92 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approvedsteel primer. |
| 93 | The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. \\"All above operations to be done in order and as directed and specified by the Engineer-in-Charge: With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 94 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes. 110mm diameter |
| 95 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. COUPLER 110 MM |
| 96 | SINGLE TEE WITH DOOR |
| 97 | BEND 87.5 DEGREE 110 MM BEND |
| 98 | SHOE(PLAIN) 110 MM SHOE |
| 99 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) and a coat of neat cement, punning, rounding the edges and making and finishing the outlet complete. |
| 100 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement: 4 coarse sand) and makin good the wall etc. complete. 110mm |
| 101 | Providing and fixing to the inlet mouth of rain water pipe Fast iron grating 15 cm diameter and weighing not less han 440 grams. |
| 102 | Centering and shuttering including strutting, proppingetc. and removal of form for:: Foundations, footings, bases of columns, etc. for mass concrete Columns, Pillars, Piers, Abutments, Posts and Struts . |
| 103 | Lintels, beams, plinth beams, girders, buttresses and cantilevers |
| 104 | Suspended floors, roofs, landings, balconies and accessplatform. |
| 105 | DRAIN |
| 106 | EARTH WORK |
| 107 | P.C.C in Foundation (1:4:8) |
| 108 | P.C.C in Foundation (1:2:8) |
| 109 | Plaster 15 mm |
| 110 | Brick work 1:4 |
| 111 | GST will be paid extra as per rule applicable Please Enable Macros to View BoQ information |