| 1 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.a. In cement mortar |
| 2 | Dismantling tile work in floors,wall and roofs laid in cement mortar including stacking material within 50 metres lead. A. For thickness of tiles 10 mm to 25 mm. |
| 3 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in-charge. |
| 4 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form for Edges of slabs and breaks in floors and walls A. Under 20 cm wide |
| 6 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 7 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level a. Concrete of M25 grade with minimum cement content of 330 kg /cum. |
| 8 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :A. 1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 9 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. A.Hot finished welded type tubes.(Shop Drawing of Pergola and Trusses shall be provided by agency nothing shall be paid on account of shop Drawings). |
| 10 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete. (Shop drawing of Staircase shall be provided by agency nothing extra shall be paid on account of shop Drawings) |
| 11 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. A.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. (Shop drawings of railing shall be provided by agency nothing shall be paid on account of shop drawings) |
| 12 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm |
| 13 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. a. Size of Tile 600x600 mm |
| 14 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-incharge.A.Size of Tile 600x600 mm |
| 15 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle anger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering pto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : A. 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) |
| 16 | 12 mm cement plaster of mix :a. 1:4 (1 cement: 4 coarse sand) |
| 17 | 15 mm cement plaster on rough side of single or half brick wall of mix: A. 1:4 (1 cement: 4 coarse sand) |
| 18 | 6 mm cement plaster of mix : A. 1:3 (1 cement : 3 fine sand) |
| 19 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 20 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: A. New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 21 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 22 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats |
| 23 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane. A. 3 mm thick |
| 24 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. a. 15 mm nominal dia Pipes |
| 25 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. a. 20 mm nominal dia Pipes |
| 26 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. a. 25 mm nominal dia Pipes |
| 27 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. a. 32 mm nominal dia Pipes |
| 28 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank . |
| 29 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). |
| 30 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 31 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :A. With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 32 | Providing and fixing in position factory made non asbestos fibre reinforced aerated cement sandwich wall/roof/floor light weight solid core panels made of light weight cement concrete core composed of OPC cement, pulverized flyash, quick lime, cotton pulp & Gypsum in mortar state mixed with aeration agent in a preset mould. The outer face on both sides of the panels will be non asbestos fibre cement board conforming to IS 14862:2000. These solid wall panels are installed using Galvanized iron steel tracks/C channel of 1mm thick of required sizes as recommended by manufacturer’s and fixed to floor and RCC soffit in plumb to each other with steel screw/fasteners. The panel shall be fixed vertically with tongue & groove joint with cement based polymer modified jointing compound. The exposed surface finished with fibre mesh/glass fibre tape with polymer based jointing compound having superior flexibility. Panels should be used as floor & roofing with additional structural support, steel or RCC depending upon the design. All the operation shall be completed in all respect as per drawings, Manufacturers specifications and under the overall direction of Engineer-in- Charge (Cost of all the material is included except “tracks/C channel” which will be paid separately). A. Non load bearing panels 50 mm thick of required size (minimum 4mm thick fibre cement board Type A, Category IV as per IS: 14862:2000 on both faces) |
| 33 | Providing and fixing 12 mm thick frameless toughened glass for glazing of approved brand and manufacture, including providing and fixing with patch fitting, U Channel etc as per requirement all complete. as per direction of Engineer-in-charge (Nothing extra shall be paid). |
| 34 | Providing & fixing of white vitreous China wall mounting cascade type water closet (Jaquar Kubix Cat No SLS-WHT-6951 JUFSM / KOHLER Cat No. K-18131K-WD-O / Hindware cat. no. 270409) with CP bolts, nuts, CI chair hanging arrangements, Bakelite seat & cover with CP hinges & rubber buffers, CP brass screw, washer with all accessories with WC connector with Rubber Lip / Buffer and side gap filled with silicon sealant wherever required. Including brass / SS screws and washer complete including cutting, making good the walls, floors, slab wherever required as per direction of Engineer- In-charge.: W.C. pan with ISI marked white solid plastic seat and lid. All complete as per Direction of Engineer-in-charge.(Nothing extra shall be paid). |
| 35 | Providing and fixing table top wash basin of size 495mm*395mm*150mm (Jaquar Cat No.JDS-WHM-25909) alongwith click clack waste jali (Jaquar Cat No. ALD-CHR-727L130) , with all fittings and fixtures complete, including cutting and making good the counters and floors wherever required. |
| 36 | Providing and fixing 32 mm dia. Bottle Trap (Jaquar Cat. No. ALD-769L250x190 / KOHLER cat no. K-16407IN-CP) and other ancillary fittings, cutting and making good the walls wherever requiredcomplete as per directions of Engineer-In-charge. |
| 37 | Providing and fixing single lever tall boy 600mm high and 150 mm long spout basin mixer (Jaquar OPP-CHR-15005BPM) with all fittings and fixtures complete and as per manufacturer's specification, including cutting hole in counter and making good wherever required. |
| 38 | Providing and fixing C.P. brass Hand shower (Health Faucet) having flexible tube of required length and wall hook of approved make etc. model no. Cat-ALD-CHR-573 of Jaquar or equivalent or better in cost and specification etc,all complete as per direction of Engineer-in-Charge. |
| 39 | Providing and fixing C.P. brass toilet paper roll holder with flap with CP brass flange of approved make including fixing with PVC rawl plugs & screws etc. model no. Cat.-ACN-CHR-1153 S of Jaquar or equivalent model of approved make all complete as per direction of Engineer-in-Charge. |
| 40 | Providing and fixing C.P. brass angular stop cock / angle valve with wall flange of approved make etc. all complete as per direction of Engineer-in-Charge. A.15 mm nominal bore. Model no.-OPP-15053PM of Jaquar or equivalent model of approved make. |
| 41 | Providing & fixing white vitreous China flat back urinal (Jaquar Cat No URS-WHT-13253O / KOHLER model no. 18645T-CP / Queo model no. Q257610210) comprising of all plumbing items including pressmatic flush valve (Jaquar Cat No. PRS chr 073), CP brass flush pipe with CP brass elbow, CP brass spreader, CP wall flange, and any other item required to provide satisfactory functioning including necessary wall cutting / chasing and making good, as required for urinal flushing complete as mentioned above as per direction of Engineer-In-charge.(All complete Nothing extra shall be paid). |
| 42 | Applying PU paint system over mild steel surface including surface preparation, one coat epoxy primer, one coat epoxy intermediate and two coats polyurethane finish paint complete as per specifications. All complete as per direction of engineer in charge. |
| 43 | Providing and fixing fiberglass reinforced asphalt roofing shingles of approved make and colour, size approximately 1000 mm × 330 mm, having ceramic coated mineral granule finish and self-sealing adhesive strip with fiberglass mat base, weighing not less than 10–12 kg per sqm, laid over waterproof underlayment i.e APP membrane of 3mm thick on factory made non-asbestos fibre reinforced aerated cement sandwich roof panels, fixed with galvanized roofing nails and approved adhesive in proper overlapping including starter course, cutting, fitting, sealing at ridges, hips and valleys and all necessary accessories complete as per manufacturer’s specifications and directions of Engineer-in-Charge.(Cost of APP Membrane and factory made non-asbestos fibre reinforced aerated cement sandwich roof panels in agreement item no.23 & 32 Respectively). All inclusive Nothing shall be paid extra).makes: IKO / Owens Corning / GAF / TAMKO / or equivalent. |
| 44 | Providing and fixing fiberglass reinforced asphalt roofing shingles Ridge and hip of approved make and colour, size as required , having ceramic coated mineral granule finish and self-sealing adhesive strip with fiberglass mat base, fixed with galvanized roofing nails and approved adhesive in proper overlapping including starter course, cutting, fitting, sealing at ridges, hips and valleys and all necessary accessories complete as per manufacturer’s specifications and directions of Engineer-in-Charge. Approved makes: IKO / Owens Corning / GAF / TAMKO / or equivalent. |
| 45 | Providing and fixing change room cubicles ( includes 600 mm door size width)of reputed make like Greenlam, Merino Formica ( R) or equivalent made up of thermosetting resign treated high pressure ,self-supporting decorative compact laminates with permanently incorporate anti-bacterial agents during manufacturing .Compact board should be resistance to water immersion through permissible increase on thickness and mass 1.35kg/cm3 and fulfilled the criteria of FSC and Green Guard Gold Certification and manufactured under EN438-2&3:2005 standard. 12mm thick compact board should be Moisture resistant, Impact resistant, termite resistant, Scratch resistant, Weather and climatic shock resistant. Finish of compact laminates should be suede finish which includes door, pilasters and intermediate panels finished with approved texture/shades as per IS2046 and fulfilled the criteria of fire retardant under BS-476/9 7 and EN438-6 with classification of BS1D0 standard, all complete as per manufacturer’s specification and as per the direction of Engineer-in-charge.Hardware and Fixing:- All hardware, fittings and accessories as per manufacturer's specifications shall be in stainless steel grade SS 304. The pilasters are anchored to the flooring using SS 'L\\" angles and covered with SS plates all of grade 304. To ensure that there is no lintel at the top.Accessories :- Standard accessories include SS Hinges, SS door knob, SS thumb turn indicator, SS coat hook, SS shoe box and SS channels etc. all in SS 304 grade as per manufacturer’s specifications.Floor mounted Cubicles shall be of size as under:Door size - 600mm x 1800 mm. There will be no section above top of door.-(a) Toilet cubicles, change room cubicles & shower rooms of size 1580mmx1050mmx2100mm (Height is including 100mm gap form bottom). |
| 46 | Less for GST Correction Factor @ 0.027 on DSR items(item 1 to 33 Please Enable Macros to View BoQ information |