| 1 | Civil Works |
| 2 | All kinds of soil Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth as desired by the Engineer-in-charge. |
| 3 | Providing and laying in position cement Concrete of specified grade 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggrega 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size to complete the job as per the instructions of Engineer-in-Charge |
| 4 | Coursed rubble masonry with hard stone (Second sort or second sort) in superstructure above plinth level and upto floor five level.Masonry work (second sort) , in cement mortar 1:6 (1 cement : 6 coarse sand) to complete the job as per Instructions of Engineer-In-Charge |
| 5 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) Complete the job as per the instructions of engineer-In-charge |
| 6 | Centering and shuttering including strutting, Foundations, footings, bases for columns complete the job as per Instructions of Engineer-In-Charge |
| 7 | Thermo-Mechanically Treated bars of grade HYSD Fe-500 or as per instructions of Engineer-In-Charge |
| 8 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 3 in superstructure above plinth level up to floor V level in all shapes and sizes to complete the job as per Instructions of Engineer-in-Charge |
| 9 | Providing and laying RCC band course 50 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone hand broken stone 20 to 40 mm nominal size) to complete the job as per Instructions of Engineer-in-Charge |
| 10 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished smooth with sponge. to complete the job as per instructions of engineer-In-charge |
| 11 | MS. Steel work in built up tubular (round, square or rectangular hollow tubes etc.) Electric resistance or induction butt welded tubes Class-B and truses Class-B type sections etc., wtih decorative type of coping as per required Electric resistance or induction butt welded tubes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 12 | Structural steel work riveted, bolted or welded in built up Top and Bottom welding 8mm thick Iron gate with required shape and dimensions to complete the job as per Instructions of Engineer-In-Charge |
| 13 | Providing and laying vitrified floor tiles in Size of Tile 600x600 mmdifferent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 14 | Providing and fixing 30 mm flush door shutters thick including ISI marked Stainless Steel butt hinges with necessary screws ISI marked onforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. |
| 15 | Providing and fixing 4mm G.I. chain link fabric fencing of required width in mesh size 50x50 mm with required colour poweder coated ncluding strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. |
| 16 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622(thickness to be specified by the manufacture) of approved make jhonson or equilent in all colours,shades except burgundy,bottle green,black, Motiff or dark shades of size of 1' x 2' as approved by Eningeer-in-Charge in skirting, risers of steps and dados shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints including pointing in tile grout mixed with pigment of matching shade complete.complete the job as per Instructions of Engineer-In-Charge |
| 17 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make jhoson or equilent in colours such as White, Ivory, Grey, Fume Red Brown,shade, laid with in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing the joints with tile grout and matching pigment etc., complete. to complete the job as per Instructions of Engineer-In-charge |
| 18 | Providing and fixing White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests water closet squatting pan (Indian type W.C. pan or Western pattern) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: |
| 19 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and make if Ashriwad and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. |
| 20 | Providing and fixing 100.0 x 75mm UPVC nahini trap\ floor trap including laying of cement concrete of 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of nominal size). And arrange necessary requirements to complete the job as per Instructions of Engineer-In-Charge |
| 21 | Distempering with 1st quality acrylic oil bound washable distemper of approved brand and manufacture to give an even shade with 1.5 @ 10sqm (make of Asian-Tractor Acrylic Aqua lock or equivalent ) old work (two or more coats) over and including priming coat 0.70 @ 10 sqm with cement primer make of Asian, applying of crack seal and arrange the julas, Scaffolding,wire brushes etc. to complete the as per instructions of Engineer-In-Charge |
| 22 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:(Make : Asian Apocolite) Two or more coats on new work over an under coat of suitable shade with wood primer and Applying of putty and with neat papering to complete the job as per Instructions of Engineer-in-Charge paint of approved brand and manufacture. |
| 23 | Providing and fixing factory made Frame size 50 x 100 mm single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. |
| 24 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain 30mm thick flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. including 3 nos each side 4\\" stainless steel butt hinges for required design including necessary S.S screws to complete the job as per instructions of Engineer-In-Charge |
| 25 | Providing and fixing aluminium 150x10 mm tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 26 | Providing and fixing aluminium100mm handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 27 | Providing and fixing 15mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 28 | Providing and fixing 45 cm length uplasticised PVC connection pipe with brass unions with necessary requirements to complete the job as per Instructions of Engineer-In-Charge |
| 29 | Providing and fixing Fixed to steel windows by welding M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete and arrange necessary screws and fixing the frame as per instructions of Engineer-In-Charge |
| 30 | Providing and fixing 100 mm Stainless steel jali with or without hole for waste pipe minimum weight of 40 grams or more complete the job as per Instructions of Engineer-In-Charge |
| 31 | Providing and fixing 32 mm dia Flexible pipe P.V.C waste pipe for sink, wash basin or urinals including P.V.C waste fittings complete complete the job as per Instructions of Engineer-In-Charge |
| 32 | Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS:8931 and weighing not less than 530 gms. With flange .(make of Seiko or equivalent) of approved quality conforming to IS:8931 complete the job as per Instructions of Engineer-In-Charge |
| 33 | Providing and fixing 15 mm nominal bore C.P. brass stop cock (concealed) of standard design and of approved make of Seiko or equivalent conforming to IS:8931.complete the job as per Instructions of Engineer-In-Charge |
| 34 | Providing and fixing 15 mm nominal bore C.P. brass anguler stop cock of standard design and of approved make make of Seiko conforming to IS:8931.complete the job as per Instructions of Engineer-In-Charge |
| 35 | Providing and fixing 75 mm diameter on wall/column face/floor unplasticised PVC Prince SWR , Type-B Class. Fittings (working pressure 4 Kg.per sqcm) rain water pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. (i) Single socketed pipes ii) double socketed pipes complete the job as per Instructions of Engineer-In-Charge |
| 36 | Providing and fixing 110mm diameter on wall/column face/floor unplasticised PVC Prince SWR , Type-B Class. Fittings (working pressure 4 Kg.per sqcm) rain water pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. (i) Single socketed pipes ii) double socketed pipes complete the job as per Instructions of Engineer-In-Charge |
| 37 | Providing and fixing 75mm Coupler on wall/column face/floor unplasticised-PVC moulded Prince SWR , Type-B Class fittings/accessories for unplasticised-PVC rain water pipes con- forming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion. i/c testings complete the job as per Instructions of Engineer-In-Charge |
| 38 | Providing and fixing 75x75x75 mm Single tee with door on wall/column face/floor unplasticised-PVC moulded Prince SWR , Type-B Class fittings/accessories for unplasticised-PVC rain water pipes con- forming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion. i/c testings complete the job as per Instructions of Engineer-In-Charge |
| 39 | Providing and fixing 110x110x110mm Single tee with door on wall/column face/floor unplasticised-PVC moulded Prince SWR , Type-B Class fittings/accessories for unplasticised-PVC rain water pipes con- forming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion. i/c testings complete the job as per Instructions of Engineer-In-Charge |
| 40 | Single tee without door Providing and fixing 75x75x75 mm on wall/column face/floor unplasticised-PVC moulded Prince SWR , Type-B Class fittings/accessories for unplasticised-PVC rain water pipes con- forming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion. i/c testings complete the job as per Instructions of Engineer-In-Charge |
| 41 | Providing and fixing 110x110x110mm Single tee with out door on wall/column face/floor unplasticised-PVC moulded Prince SWR , Type-B Class fittings/accessories for unplasticised-PVC rain water pipes con- forming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion. i/c testings complete the job as per Instructions of Engineer-In-Charge |
| 42 | Providing and fixing 75mm Bend 87.5 degree/ less or moreon wall/column face/floor unplasticised-PVC moulded Prince SWR , Type-B Class fittings/accessories for unplasticised-PVC rain water pipes con- forming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion. i/c testings complete the job as per Instructions of Engineer-In-Charge |
| 43 | Providing and fixing 110 mm bend 87.5 degree/ less or moreon wall/column face/floor unplasticised-PVC moulded Prince SWR , Type-B Class fittings/accessories for unplasticised-PVC rain water pipes con- forming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion. i/c testings complete the job as per Instructions of Engineer-In-Charge |
| 44 | Providing and fixing 75mm door Bend 87.5 degree/ less or moreon wall/column face/floor unplasticised-PVC moulded Prince SWR , Type-B Class fittings/accessories for unplasticised-PVC rain water pipes con- forming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion. i/c testings complete the job as per Instructions of Engineer-In-Charge |
| 45 | Providing and fixing 110 mm door bend 87.5 degree/ less or moreon wall/column face/floor unplasticised-PVC moulded Prince SWR , Type-B Class fittings/accessories for unplasticised-PVC rain water pipes con- forming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion. i/c testings complete the job as per Instructions of Engineer-In-Charge |
| 46 | Finishing walls with Acrylic Smooth exterior paint of required shade brand of Apex ultima weather proof Asian: New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of water proof compound of damp proof or equalient applied @ 2.20 kg/ 10 sqm) and arrange the julas, scaffolding,wire brushes etc. to complete the as per instructions of Engineer-In-Charge to arrange the julas, scaffolding,wire brushes etc. to complete the as per instructions of Engineer-In-Charge |
| 47 | Providing wood work in Second class teak wood frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length |
| 48 | Providing and fixing glazed 30mm shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. |
| 49 | Providing and fixing 30mm wire gauge shutters using galvanized SS. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : |
| 50 | Supplying and Wiring for light/ Fan point/ Exhaust fan point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel condut, with modular plate, suitable GI box and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc. as required (Group-C) |
| 51 | supplying wiring for power point circuit wiring alongwith earth wire with the 2*2.5 sq mm+ 1*2.5sq mm earth wire size of FRLS PVC insulated copper conductor, single core cable in surface/ recessed meadium class PVC conduit as required |
| 52 | Supplying and fixing 5/6A modular switch on the existing modular plate and switch box including connections but excluding modular plate etc. as required |
| 53 | Supplying and fixing 15/16A modular socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required |
| 54 | supplying and fixing 5A to 32A rating 240/415V, 10kA, 'C' curve miniature circuit breaker suitable for inductive load of single poles in the 10A/16A MCB DB complete with connections, testing and commissioning etc, as required |
| 55 | supplying and fixing 5A to 32A rating 240/415V, 10kA, 'C' curve miniature circuit breaker suitable for inductive load of Triple pole neutral in the 32A MCB DB complete with connections, testing and commissioning etc, as required |
| 56 | Supplying and fixing 4 way triple pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess complete with testing and commissioning etc as required |
| 57 | Supplying and fixing 12 Modular (200mm*150mm) GI box alongwith Modular base and cover plate for Modular switches in recess etc. as required. |
| 58 | Supplying and fixing 3 Modular (100mm*75mm) GI box alongwith Modular base and cover plate for Modular switches in recess etc. as required. |
| 59 | Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 Nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 60 | Supplying, installation, Testing & Commissioning of Industrial model LED Batten light 36 watts (System lumen efficacy >135 lm/Watt) of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) (36 watts Phillips or equivalent as suggested by the Engineer In-charge) |
| 61 | Supplying and Fixing of step type modular fan regulator (Legrand Mylinc or equivalent as suggested by the Engineer In-charge) |
| 62 | Supplying and Fixing of White Ceiling Rose (ISI Make) |
| 63 | Supplying and Installation, Testing and Commissioning of Heavyduty model exhaust fan in the existing opening, including making good connection, testing, commissioning, anchor bolt fixing etc. as required. (crompton groove or equivalent as suggested by the Engineer In-charge) Please Enable Macros to View BoQ information |