| 1 | Demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of Engineer in-charge |
| 2 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 3 | Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) |
| 4 | Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer in-charge. |
| 5 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 6 | In cement mortar |
| 7 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 8 | Of area 3 sq. metres and below |
| 9 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: |
| 10 | Of area 3 sq. metres and below |
| 11 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 12 | For thickness of tiles 10 mm to 25 mm |
| 13 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: |
| 14 | Asbestos cement sheet |
| 15 | Demolishing integral cement based waterproofing treatment upto floor five level and of average thickness upto 120 mm manually/ by mechanical means including disposal of material to Municipal dumping ground lead upto 5 Km and as per direction of Engineer in charge. |
| 16 | Dismantling old damaged wash / urinal / EWC basins including disconnecting the connections and disposal of rubbish to the dumping ground as directed by the Engineer-in-charge. |
| 17 | Credit for taking away recovered steel reinforcement / Mild steel bars (unserviceable) in available diameters and avaialable lengths and shape. |
| 18 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 19 | 1:3:6 (1 Cement : 3 coarse sand(zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 20 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc., up to floor five level, excluding the cost of centering, shuttering and finishing : |
| 21 | 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 22 | Centering and shuttering including strutting, propping etc. and removal of form work for : |
| 23 | Columns, piers, abutments, pillars, posts and struts. |
| 24 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification. |
| 25 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 26 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 27 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 28 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 29 | Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement mortar 1:3 (1 Cement : 3 fine sand). |
| 30 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 31 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 32 | Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in : |
| 33 | Cement mortar 1:6 (1 cement : 6 Coarse sand) |
| 34 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
| 35 | Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineer-in-Charge. |
| 36 | Providing and fixing factory made PVC Door shutter made of solid foam PVC profiles of thickness 5 mm and 15 mm at edges integrally extruded for vertical style and horizontal (top / bottom / lock) rails of minimum cross section of 70mm x 28mm, of shape and design as per manufacturer's specifications having homogenous fine cellular structure and smooth integral outer skin, inserted with G.l. 'C' section/ rectangular tube profile of minimum 0.30 mm thickness with 120 gsm coating as stiffeners as per manufacturer's specifications Mitered cut joints for styles and rails provided with telescopic polymeric L' corners are joined together using solvent adhesive and strengthened with fully threaded stainless steel screws (of required size) through reinforcement stiffener with paneling of specified solid foam PVC board / high pressure laminate of required thickness and of approved design and shade (matching the styles and rails), secured within styles and rails with specially designed solid foam PVC moulded headings of required size using PVC solvent adhesive / cement. The finished door shutter including SS hardware, 1 no. SS sliding door bolt 200 x 10mm, 1 no. SS tower bolt 200 x 10mm and 2 nos. SS handles 125 mm, shall be fixed to frame with 3 Nos. stainless steel hinges of minimum size 100x58x1.9mm and stainless steel screws of required size complete as per direction of the Engineer-in-Charge.(Cost of above hardware is inclusive in rates) |
| 37 | 5 mm thick solid foam PVC panel of required size with moulded/extruded beading of appropriate design shape and size as per manufacturer's specifications (to secure the panel insert tight in place within the style and rails of the shutter)matching the color &shade of shutter frame - Non decorative type. |
| 38 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 39 | With float glass panes of 4.0 mm thickness (weight not less than 10 kg/sqm) |
| 40 | Fixing aluminium partitions with available aluminium sections, prelaminated particle board / aluminium grill or glass panes etc., including providing new necessary screws, rubber gasket, cleats and including carriage of materials from Staff Quarters at Dubba as per the directions of the Engineer-in-charge. |
| 41 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 42 | 40 mm thick with 20 mm nominal size stone aggregate |
| 43 | Cuddapah stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : |
| 44 | (a) 18mm thick minimun. |
| 45 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /seIf tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 46 | Repairs to integral cement based water proofing treatment including chipping of the old partially damaged top integral cement based water proofing treatment. Preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: |
| 47 | (a) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. |
| 48 | (b) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : |
| 49 | 12 mm cement plaster of mix : |
| 50 | 1:6 (1 cement: 6 fine sand) |
| 51 | 15 mm cement plaster on the rough side of single or half brick wall of mix : |
| 52 | 1:6 (1 cement: 6 fine sand) |
| 53 | White washing with lime to give an even shade : |
| 54 | Old work (two or more coats) . |
| 55 | Old work (one or more coats) . |
| 56 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 57 | Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface). |
| 58 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-harge. |
| 59 | With cement mortar 1:4 (1 cement : 4 fine sand). |
| 60 | Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in- charge. |
| 61 | Providing & fixing White vitreous china water closet squatting pan (Indian type) along with \\"S\\" or \\"P\\" trap including dismantling of old WC seat and \\"S\\" or \\"P\\" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. |
| 62 | Orissa pattern W.C Pan of size 580x440 mm |
| 63 | Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineerin-Charge. |
| 64 | (a) Internal Work- Exposed on wall |
| 65 | Providing scafolding arrangements with casuarina props and wooden planks inside the gent toilet to attend repairs in the ceiling and walls upto 5.00m height. The scaffolding system shall be stiffened with bracings, runners etc, wherever required with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. |
| 66 | Cleaning of drainage manholes and sewer lines by removing the deposited and other rubbish from the manholes and cleaning the sewer lines by rodding and flushing with water as directed by the Engineer -in- charge. (Rate per One manhole and sewer line to next manhole) |
| 67 | Cleaning of ceramic tile flooring / dado in bath/ wc area with disinfectors and making the tile stain free by rubbing with scrubbers using mild acid, detergent powder etc and finally washin neatly with water complete to be in usable condition all as directed. |
| 68 | Welding by gas or electric plant including transportation of plant at site etc. upto 200 spots in the old reinforcement bars all complete as per the directions of Engineer-in-charge. The rates inclusive of all labour involved, rent for the welding unit, transportation, ascending and descending to the required height in the building, arrangements for power tapping etc and nothing extra payable. |
| 69 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 70 | White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap |
| 71 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. |
| 72 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 73 | Flexible pipe |
| 74 | 32 mm dia |
| 75 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : |
| 76 | Rectangular shape 453x357 mm |
| 77 | Providing and fixing UV stabilised PVC trap of self cleansing design with PVC grating complete, including cost of cutting and making good the walls and floors: |
| 78 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall |
| 79 | 20 mm nominal outer dia. Pipes. |
| 80 | 25 mm nominal outer dia .Pipes. |
| 81 | Providing and fixing CPVC ball valve of approved make for CPVC pipe lines. |
| 82 | 32 mm dia |
| 83 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 84 | 45 cm length |
| 85 | 15 mm nominal bore |
| 86 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 87 | Providing and fixing PTMT angle stop cock 15 mm nominal bore. Weighing not less than 85 gms. |
| 88 | Supplying and fixing C.I. cover without frame for manholes : |
| 89 | 455x610 mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg. |
| 90 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge |
| 91 | 50 mm average thickness |
| 92 | 25 mm average thickness |
| 93 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. |
| 94 | Bars upto 12 mm diameter |
| 95 | Bars above 12 mm diameter |
| 96 | Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge. |
| 97 | Upto and including 12mm dia. |
| 98 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. |
| 99 | SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer |
| 100 | Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. |
| 101 | Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2). |
| 102 | 12 mm average thickness. |
| 103 | Providing and laying SBR Polymer modified (of approved make @ minimum 2% by wt. of cement used) plain/ reinforced concrete jacket for the structural members e.g. columns, pillars, piers, beams etc with concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10mm maximum size in proportion as per design criteria] with specified average thickness all-round existing core of RCC member. |
| 104 | Note: Rates shall be for finished surface area of concrete and shall include the cost of making holes in existing RCC slab, if required, for pouring concrete in shuttering mould of jacket and appropriate approved Super-Plasticiser for rendering concrete as flowable self compacting and SBR polymer but shall exclude cost of reinforcement, bond coat, Shear Keys, centering and shuttering, strutting, propping etc. |
| 105 | (Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument) |
| 106 | 50mm thick in Grade M 25 with cement content not less than 330 kg per cum |
| 107 | 75mm thick in Grade M 25 with cement content not less than 330 kg per cum Please Enable Macros to View BoQ information |