| 1 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil : |
| 2 | P/L, of stone soling duly hand packed with ramming, dressing, watering and compacting all inclusive leads, lifts, loading, un-loading, cost and carriage of material involved complete finsished work to be measured. |
| 3 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 4 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) incl. carriage all complete. |
| 5 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto Floor V-Level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) complete. |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form work for: Retaining walls, return walls, walls (any thickness) including attached pilasters buttresses, plinth and string course fillets, kerbs and steps etc complete. |
| 7 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 8 | Supplying, and filling of GSB/Khak Bajree under Floors in trenches, plinth sides of foundation including spreading, levelling, ramming, dressing & watering, all inclusive leads, lifts, loading, un-loading, cost and carriage of materials from approved source of site of work complete |
| 9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m all complete |
| 10 | 12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand) incl. scaffoldings all complete. |
| 11 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. Hot finished welded type tubes all complete. |
| 12 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete Welded |
| 13 | Providing/Fixing of Colour coated (Hi-Rib) G.S profile sheets for roofing including vertical/curved surface fixed with Polymer coated J or l hooks, bolts and nuts 8mm diameter with bitumen and G.I Limpet washers or with G.I Limpet washers filled with white lead, including overlapping of sheets complete (upto any pitch in horizantal/ vertical or curved surface) excluding the cost of purlins, rafters (0.50mm thick) etc incl ridges hips/ valleys 60cm vide of colour GI sheets sheets including cost of screws/ washers all complete and cost and carraiges of materials complete |
| 14 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20 mm nominal size stone aggregate.complete |
| 15 | Providing and Fixing of Insulated Sandwich PUF Panels having tongue and groove joinery System , made out from continuous line automatic machine total thickness 60mm with 1 mtr panel with micro ribs at 100mm c/c on both sides of polyurethane foam confirming to IS: 12436:1988. The panels will be made of 0.50 mm thick hot dipped galvanized steel sheets on both sides .The pre Coated sheet grade confirming to IS: 14246:1995 and having zinc coating minimum 120 gsm as per IS 1992, 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 micron . The PPGI sheet have plastic protective guard film of 25 micron to avoid Scratches while transportation . The panels will be vertically joined together by toungue and groove joints . The PU foam will be self Extinguising , fire retardand type having density of 3kg/cum for walling (wall thickness 60mm) |
| 16 | Providing and fivxing of Aluminium Hardware iteams of approvewd brand and make including necessary fittings/fixtures complete:- 250mm Handles |
| 17 | Tower Bolts 250mm |
| 18 | 150mm Handles |
| 19 | Tower Bolts 150mm |
| 20 | Air Hooks |
| 21 | L Drop |
| 22 | Providing and Fixing of Insulated Sandwich PUF Panels having tongue and groove joinery System , made out from continuous line automatic machine total thickness 40 mm with 1 mtr panel with micro ribs at 100mm c/c on both sides of polyurethane foam confirming to IS: 12436:1988. The panels will be made of 0.50 mm thick hot dipped galvanized steel sheets on both sides .The pre Coated sheet grade confirming to IS: 14246:1995 and having zinc coating minimum 120 gsm as per IS 1992, 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 micron . The PPGI sheet have plastic protective guard film of 25 micron to avoid Scratches while transportation . The panels will be vertically joined together by toungue and groove joints . The PU foam will be self Extinguising , fire retardand type having density of 3kg/cum for ceiling. (ceiling thickness 40mm) |
| 23 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ ppropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia.and size including Necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in- Charge (glazing, panelling and dash fasteners to be paid for separately.) For fixed portion For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.) Anodized aluminum (Anodized transparent or dyed to required shade according to IS:1868, minimum anodic coating of grade AC 15) |
| 24 | Providing and fixing glazing in aluminum door, window, ventilator Shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in- Charge. (Cost of aluminum snap beading shall be paid in basic item.) With floating glass panes of3.5 to 4.0 mm thickness (weight not less than 10.00 kg / sqm) |
| 25 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board (conforming to IS: 12823 Grade-I type-II) in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-incharge. Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side all complete. |
| 26 | Carriage of Material Sand/Stone agg. Avg. lead of 10 Kms |
| 27 | Providing and fixing of 2mm thick C.R sheets for soffits over angle iron framework 25 x 25x 4mm, with priming and paintitng coat including cost of scaffolding, welding etc complete: |
| 28 | Providing and fixing of 2mm thick C.R sheets Eaves Boarding over angle iron framework 24x 25 x 4mm with priming and painting coat including cost of scaffoldings, welding etc complete, all carriages involved- complete. |
| 29 | Wiring for light point / exhaust fan point with (P+N+E) 3x1.5 sq.mm FRLS-H PVC insulated Multi strand Copper conductor single core cable in existing surface/recessed Conduits.The job including cost of Circuit Wire (6/8 points per circuit) in 2.5 sq.mm (with 1x2.5 sq.mm) for earth Multi strand Copper wire from Switch board to D.B complete (Havells/Polycab/Anchor Make) with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover in front,Modular blanking plate where required & suitable GI box etc ISO/IEC Certified Havells/ Legrand/Panasonic/Anchor Rooma Plus/Schneider Make & shall be approved before execution of work LED conceiled Lamp of 100mm dia |
| 30 | Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Polycab/Anchor Make) including cost of Conduits with other accessories like bends,etc complete to be laid in wall and finishing the surface to its original shape by cement mortar plastering/Wall Putty/Paint etc with 01 No. of 16Amp,Modular switch, Modular 01 No. of 3-PIN 16Amp Socket, Modular plate, cover in front,Modular blanking plate where required and suitable GI box etc ISO/IEC Certified Havells/Legrand/ Panasonic/Anchor Rooma Plus/Schneider Make & shall be approved before execution of work. |
| 31 | Supply/Fixing/Testing and Commissioning of 5Amp to 32Amp Rating ,240v,*C* Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB . DB Complete with connections. (Havells/L&T/Siemens/Legrand/ABB /Schneider Make) |
| 32 | Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Polycab/Anchor Make) including cost of Conduits with other accessories like bends,etc complete to be laid in wall and finishing the surface to its original shape by cement mortar plastering/Wall Putty/Paint etc with 01 No. of 16Amp,Modular switch, Modular 01 No. of 3-PIN 16Amp Socket, Modular plate, cover in front,Modular blanking plate where required and suitable GI box etc ISO/IEC Certified Havells/Legrand/ Panasonic/Anchor Rooma Plus/Schneider Make & shall be approved before execution of work. Please Enable Macros to View BoQ information |