| 1 | Supply and fixing switch piano type, flush type, single pole, one way 5 Amps, complete all as specified and directed. |
| 2 | Supply and fixing switch socket combination 2 in 1, 6A flush type piano type, flush type, single pole, one way 5 Amps, complete all as specified and directed. |
| 3 | Supply and fixing bell push, flush type, 5A, complete all as specified and directed. |
| 4 | S&F switch piano type, flush type, single pole, two way 15 Amps, complete all as specified and directed. |
| 5 | Supply and fixing switch socket combination 2 in 1, 5 pin, 5 and 15 Amp flush type complete all as specified and directed. |
| 6 | S&F in repairs ceiling rose surface bakelite 3 terminals 63.5 x 17 mm complete all as specified and directed. |
| 7 | Supply and fixing in repairs lamp holder PVC / polycarbonate type with back plate complete all as specified and directed. |
| 8 | Supply and fixing in repairs stepped type (switch type) electronic ceiling fan regulator flush type, AC, 230 volts , including taking down of old regulator complete all as specified and directed. |
| 9 | Supply and fixing in repairs Modular switch 1 way 5/6A, 1 module complete all as specified and directed. |
| 10 | Supply and fixing in repairs Modular switch socket combination 15/16 Amp, 5/6 pin, active white, 3module complete all as specified and directed. |
| 11 | Supply and fixing in repairs Modular switch socket combination 5 Amp, 5 pin, active white , 2module complete all as specified and directed. |
| 12 | Supply and fixing in repairs modular fan step regulator, 120W - 2 module complete all as specified and directed. |
| 13 | Supply and fixing in repairs Modular bell push, 6A, 1 module complete all as specified and directed. |
| 14 | Taking down ceiling fans of any make and sweep from ceiling hook existing position complete including disconnecting and transporting to workshop for repair complete all as specified and directed. |
| 15 | M&L for servicing / over hauling of ceiling fan of any make and sweep including labour cost for dismantling, replacement of worn out spare parts, reassembling and testing for smooth functioning complete all as specified and as directed.Note: (a) Spare parts will be measured and paid separately as supply only under respective items of BOQ.(b) Labour cost for replacement of worn out spare parts deemed to include in the unit rate quoted by Contractor. |
| 16 | Supply only ceiling fan mounting clamp with rubber bush with nut and bolt suitable for ceiling fan any size and make complete all as specified and directed. |
| 17 | Supply only Ball bearing suitable for ceiling fan 1200/1400mm sweep of any make complete all as specified and directed. |
| 18 | Supply only down rod 60cm long suitable for ceiling fan complete all as specified and as directed. |
| 19 | Supply only down rod 100cm long suitable for ceiling fan complete all as specified and as directed. |
| 20 | Supply only canopy suitable for ceiling fan complete all as specified and as directed. |
| 21 | Supply only Capacitor 2.5 MFD, AC 250 volts capacity complete all as specified and directed. |
| 22 | Supply only capacitor 4.5 MFD, AC 250 volts capacity complete all as specified and directed.Note for item No. 16.00 to 22.00: Labour cost deemed to be included in the rate quoted for servicing / over hauling of fan. |
| 23 | Material and labour for rewinding of burnt out fan motor of Ceiling fan 1200/1400mm sweep of any make with super enameled copper winding wire of existing gauge/size including necessary tapping, varnishing and dismantling,taking down burnt copper winding,reassembling and testing for smooth functioning complete all as specified and directed. |
| 24 | Hanging only ceiling fans any make and sweep after repairs to ceiling hook by connecting with 3 core copper flexible round cable from ceiling rose to fan complete incl shifting from workshop complete all as specified and directed. |
| 25 | Taking down storage water heater of any make and any capacity complete from existing position including disconnecting all connection, dismantling and keep aside for repairs and reassembling and refixing complete all as specified and directed. |
| 26 | Supply and fixing heating element 1500/2000 watts any type as per site requirement for any make of electric water heater including taking down U/S heating element complete all as specified and directed. |
| 27 | Supply and fixing in existing position of thermostat for Geyser any type including taking down unserviceable thermostat complete all as specified and directed. |
| 28 | Supply and fixing hot water/cold water connection pipe of 600mm length with check nuts and washers in existing position including taking down old unserviceable complete all as specified and directed. |
| 29 | Supply and fixing single pole and neutral enclosure 240 volts with two pin and earth plug socket complete with one single pole MCB 240 V 32amp complete all as specified and directed. |
| 30 | Material and labour for taking down unserviceable digital energy meter(KWH) single phase after disconnection of all electric connection and transporting to authorised service center and servicing and replacement of defective components and LCD display of meter including calibration and testing for complete functioning and re-fixing in its position and making necessary connections complete all as specified and directed. |
| 31 | Supply and fixing Eco compact wall mounted LED batten for T8 W LED tube with ULTRON high efficency LED polycarbonate tube with in built driver and metal heat sink 18 watt icluding taking down old unserviceable fittings complete all as specified and directed. |
| 32 | Taking down unserviceable sub main wiring copper conductor of any size along with earth wire of any sizes complete all as specified and directed. |
| 33 | Supply and fixing sub main wiring with two run of 1.5sqmm single core, PVC insulated, unsheathed multistranded copper FRLS cable 1100 volts conductor drawn through PVC casing caping with all accessories and 1.0 sqmm PVC insulated unsheathed multistranded copper conductor FRLS cable as earth continuity wire complete all as specified and directed.Note: Two runs of main cable, one run of earth wire and one run of casing / caping will be measured as one unit for payment. |
| 34 | Supply and fixing sub main wiring with two run of 2.5sqmm single core, PVC insulated, unsheathed multistranded copper FRLS cable 1100 volts conductor drawn through PVC casing caping with all accessories and 1.5 sqmm PVC insulated unsheathed multistranded copper conductor FRLS cable as earth continuity wire complete all as specified and directed.Note: Two runs of main cable, one run of earth wire and one run of casing / caping will be measured as one unit for payment. |
| 35 | Supply and fixing sub main wiring with two run of 4.0sqmm single core, PVC insulated, unsheathed multistranded copper FRLS cable 1100 volts conductor drawn through PVC casing caping with all accessories and 2.5 sqmm PVC insulated unsheathed multistranded copper conductor FRLS cable as earth continuity wire complete all as specified and directed.Note: Two runs of main cable, one run of earth wire and one run of casing / caping will be measured as one unit for payment. |
| 36 | Supply and fixing sub main wiring with two run of 6.0sqmm single core, PVC insulated, unsheathed multistranded copper FRLS cable 1100 volts conductor drawn through PVC casing caping with all accessories and 4.0 sqmm PVC insulated unsheathed multistranded copper conductor FRLS cable as earth continuity wire complete all as specified and directed.Note: Two runs of main cable, one run of earth wire and one run of casing / caping will be measured as one unit for payment. |
| 37 | Supply and fixing for MCB TP 415 V, 25-63 Amps with breaking capacity 10KA C curve complete all as specified and directed. |
| 38 | Supply and fixing in repair for MCB TPN 415 V, 40-100 Amps with breaking capacity 10KA C curve complete all as specified and as directed. |
| 39 | Supply and fixing for MCB SPN 230 V, 32-63 Amps with breaking capacity 10KA C curve complete all as specified and as directed. |
| 40 | Supply and fixing for MCB SP 230 V, 6-32 Amps with breaking capacity 10KA C curve including taking down old unserviceable complete all as specified and as directed Please Enable Macros to View BoQ information |
| 41 | Supply and fixing for MCB SP 230 V, 6-32 Amps with breaking capacity 10KA C curve including taking down old unserviceable complete all as specified and as directed Please Enable Macros to View BoQ information |