| 1 | Taking down carefully point wiring (light, fan, socket, etc.) complete including battens and fittings such as switch, ceiling rose, light fittings, regulators, sockets, etc and making good to disturbed surfaces of walls, floors, etc. complete all as specified and as directed. |
| 2 | M&L for point wiring with 1.5 sq.mm of FRLSH grade PVC insulated and unsheathed stranded copper conductor cable,1100 volts grade as per IS-694 drawn through and including PVC cassing and capping (not less than 20mm wide) /conduit complete with all acessories including PVC board/ box of suitable size for mounting of switches, sockets, regulators, etc. including 1.5 sq.mm stranded copper conductor cable FRLSH grade PVC insulated and unsheathed as earth continuity conductor for one light point controlled by one way switch complete by maintaining the colour code complete all as specified and as directed. |
| 3 | All as per Serial item No. 2 here-in-before but for One ceiling / exhaust fan point controlled by one, one way switch. |
| 4 | All as per Serial item No. 2 here-in-before but for 5 amps socket point on independent board. |
| 5 | All as per Serial item No. 2 here-in-before but 5 amps socket point on same board controlled by another switch. |
| 6 | All as per Serial item No. 2 here-in-before but for One bell point controlled by one bell push. |
| 7 | All as per Serial item No. 2 here-in-before but with 2.5 sq.mm cable for 15 amps socket outlet on independent board, using 2.5 sqmm earth continuity conductor. |
| 8 | All as per Serial item No. 2 here-in-before but with 4 sq.mm cable for 20 amps power unit on independent board, using 4 sq.mm earth continuity conductor. |
| 9 | S&F ceiling rose surface backelite three terminals, PVC / polycarbonate insulated body complete all as specified and as directed. |
| 10 | S&F as in repairs switch piano flush type, 6 Amps 240 volts single pole one way complete all as specified and as directed. |
| 11 | S&F as in repairs socket outlet, 5 pin 6 Amps, flush type complete all as specified and as directed. |
| 12 | S&F as in repairs socket outlet 15/16 Amps, 6 in 1, flush type complete all as specified and as directed. |
| 13 | S&F as in repairs switch piano flush type,15/16 Amps 240 volts single pole one way complete all as specified and as directed. |
| 14 | S&F as in repairs fan regulator electronic type, rotary step, socket type 240 volts complete all as specified and as directed. |
| 15 | S&F as in repairs switch bell push flush type, 5 Amps, 240 volts complete all as specified and as directed. |
| 16 | S&F as in repairs switch socket combination 2 in 1, 3 pin, 5 and 15 Amps flush type universal with box complete all as specified and as directed. |
| 17 | S&F as in repairs switch socket combination 2 in 1, 5 Amps, flush type complete all as specified and as directed. |
| 18 | S&F as in repairs ding dong door bell 240 volts, three type music complete all as specified and as directed. |
| 19 | M&L for one LED light/LED lamp/ Bldg security light point controlled by one way switch with PVC cables 1.5 sq.mm size insulated unsheathed FRLSH cable 1100 volts grade ISI marked with multi stranded copper conductor drawn through and including non-metallic rigid PVC conduit medium grade and conduit accessories ISI marked concealed in wall/ceiling/fixed to roof, etc. and including provision of 1.5 sq.mm PVC insulated multistranded unsheathed copper conductor cable FRLSH, ISI marked as earth continuity conductor, fabricated steel sunken terminal box duly painted made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick bakelite/PVC sheet ISI marked top cover with brass/chromium plated screws and cup washers for housing switches, socket outlets, fan regulators, etc, complete all as specified and as directed. |
| 20 | All as per Serial item No.19 here-in-before but for one ceiling / exhaust fan point controlled by one, one way switch |
| 21 | All as per Serial item No. 19 here-in-before but for 5 amps socket point on independent board |
| 22 | All as per Serial item No.19 here-in-before but for One bell point controlled by one bell push. |
| 23 | All as per Serial item No. 19 here-in-before but with 2.5 sqmm cable for 15 amps socket outlet on independent board with 2.5 Sq.mm earth continuty conductor. |
| 24 | All as per Serial item No. 19 here-in-before but with 4 sqmm cable for 20 amps Power Unit on independent board with 4 Sq.mm earth continuty conductor |
| 25 | S&F as in repairs switch piano modular type, 6 Amps 240 volts single pole one way complete all as specified and as directed. |
| 26 | S&F as in repairs socket outlet, 5 pin 6 Amps, modular type, complete all as specified and as directed. |
| 27 | S&F as in repairs socket outlet 6/16 Amps, 6 in 1, modular type, complete all as specified and as directed. |
| 28 | S&F as in repairs switch piano modular type, 15/16 Amps 240 volts single pole one way complete all as specified and as directed. |
| 29 | S&F as in repairs switch bell push modular type single pole complete all as specified and as directed. |
| 30 | S&F as in repairs fan regulator stepped type, electronic modular type, 2 module, 240 volts complete all as specified and as directed. |
| 31 | S&F as in repairs socket outlet, 5 pin 6 Amps, modular type complete all as specified and as directed. |
| 32 | S&F as in repairs socket outlet 15/16 Amps, 6 in 1, flush modular complete all as specified and as directed. |
| 33 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 sq.mm nominal cross section in service connections 3 core including taking down old unserviceable cable complete all as specified and as directed. |
| 34 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sq.mm nominal cross section in service connections 3 core including taking down old unserviceable cable complete all as specified and directed. |
| 35 | S&F as in repairs LED lights fitting 1x 20W, 220 volt, AC decorative box type with driver, holder including LED tube rod connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 36 | All as per Serial Item No. 35 here-in-before but of capacity 10 Watt. |
| 37 | S&F as in repairs 20 watt tube rod 4 feet suitable for fixing in flame proof fitting complete all as specified and as directed. |
| 38 | M&L for submain wiring with two runs of single core 6 sq.mm FRLSH PVC insulated copper cable 1100 volts grade multistrand, unsheathed conductor drawn into PVC casing and capping and all necessary fittings including 1x4 sq.mm multi strand FRLSH PVC insulated copper wire for earth continuty conductor connected to common earth dolly complete including taking down old unserviceable sub main wiring of any size and making good disturbed surface complete all as specified and as directed.Notes : (a) Extra length of cables/ wire required for connection to MCBs/DBs shall not be measured and the rate quoted by the contractor for per unit shall be deemed accordingly.(b) Cuttings/ chasing of wall etc. and making good the disturbed surface shall be measured and paid seperately. |
| 39 | All as per Serial item No. 38 here-in-before but two runs of single core 4 Sq.mm for phase & neutral and 01 run of single core 2.5 Sq.mm for earth wire. |
| 40 | All as per Serial item No. 38 here-in-before but two runs of single core 2.5 Sq.mm for phase & neutral and 01 run of single core 1.5 Sq.mm for earth wire.. |
| 41 | All as per Serial item No. 38 here-in-before but two runs of single core 10 Sq.mm for phase & neutral and 01 run of single core 10 Sq.mm for earth wire.. |
| 42 | M&L for submain wiring with 4 runs of single core 6 sqmm FRLSH multistrand PVC insulated copper cable 1100 volts grade multistrand, unsheathed conductor drawn into PVC casing and capping and all necessary fittings including 2x6 sq.mm multi strand FRLSH PVC insulated copper wire for earth continuty conductor connected to common earth dolly complete including taking down old unserviceable sub main wiring of any size and making good disturbed surface complete all as specified and as directed.Notes : (a) Extra length of cables/ wire required for connection to MCBs/DBs shall not be measured and the rate quoted by the contractor for per unit shall be deemed accordingly.(b) Cuttings/ chasing of wall etc. and making good the disturbed surface shall be measured and paid seperately. |
| 43 | Taking down MCB DB / Main switch of any size and making good to disturbed surface of wall/floor, etc. complete all as specified and as directed. |
| 44 | S&F as in repairs SP&N DBs, double door, 240 volt, 12 way complete all as specified and as directed. |
| 45 | S&F as in repairs SP&N DBs, double door, 240 volt, 8 way complete all as specified and as directed. |
| 46 | S&F SP&N DBs, double door, 240 volt, 4 way complete all as specified and as directed. |
| 47 | S&F as in repairs SP&N DBs, single door, 240 volt, 2 way complete all as specified and as directed. |
| 48 | S&F TP&N DBs, double door, 240 volt, 4 way complete all as specified and as directed. |
| 49 | S&F VTPN DB, 415 volt, 4 way, 200 Amp bus bar with metal door having facility for MCCB incomming up to 250 Amps and MCB out going complete all as specified and as directed. |
| 50 | S&F VTPN DB , 415 volt, 8 way, 200 Amp Bus Bar with metal door having facility for MCCB incomming up to 250 Amps and MCB out going complete all as specified and as directed. |
| 51 | S&F as in repair MCCB 160 Amps current carrying capacity 415 volts, 25 KA, 4 pole thermal magnetic type along with spreader terminals complete all as specified and as directed. |
| 52 | S&F as in repair 415 volts, 10 KA, 'C' curve miniature circuit breaker (MCB) of TPN 40 to 100 Amps and current carrying capacity in the DB with connection testing and commissioning complete all as specified and as directed. |
| 53 | S&F as in repairs MCB single pole, 240 volts, 6 - 32 Amps, 10 KA, 'C' curve complete all as specified and as directed. |
| 54 | S&F as in repairs MCB single pole, 240 volts, 40 Amps, 10 KA, 'C' curve complete all as specified and as directed. |
| 55 | S&F as in repairs MCB single pole & neutral 240 volts, 32 Amps, 'C' curve in the MCB, DB with connection including testing complete all as specified and as directed. |
| 56 | S&F as in repairs MCB single pole & neutral 240 volts, 40 to 63 Amps, 'C' curve in the MCB, DB with connection including testing complete all as specified and as directed. |
| 57 | S&F as in repairs 415 volts, 10 KA, 'B' curve miniature circuit breaker (MCB) of TP 25 to 63 Amps and current carrying capacity in the DB with connection testing and commissioning complete all as specified and as directed. |
| 58 | S&F as in repairs LED luminaire 600mm x 600mm, 35/36 watt, 220 volt, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders and LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed. |
| 59 | S&F as in repairs recessed mounted LED 1 feet x 4 feet luminaire of capacity 40 watts with white powder coated CRCA housing with LEDs and full window acrylic diffuser etc.complete with all acessories internally prewired suitable for sigle phase 230 volts 50 Hz AC supply including connecting up with flexible copper conductor cable of size 0.5 Sq.mm (nominal area) complete all as specified and as directed. |
| 60 | S&F as in repairs LED street light fitting 30/35 watt, 230 volts, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. |
| 61 | S&F as in repairs single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps and electrically connecting up complete all as specified and as directed. |
| 62 | S&F as in repairs triple pole and neutral sheet metal enclosure with a three pin and earth plug and socket complete with one triple pole 63 Amps MCB and electrically connecting up complete all as specified and as directed. |
| 63 | S&F as in repairs lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings complete all as specified and as directed |
| 64 | S&F as in repairs 12 watts LED bulb rechargeable type with backup of 4 Hrs, CDL complete all as specified and as directed. |
| 65 | S&F as in repairs round/square recess mounted 15watts/18watts LED edge lit slim downlight with dia-cast aluminum housing finished in preminium white powder coating eficacy 100 lm/w complete with all acessories internally prewired suitable for sigle phase 230 volts, 50Hz AC supply including connecting up with flexible copper conductor cable of size 0.5 Sq.mm (nominal area) complete all as specified and as directed. |
| 66 | S&F as in repairs decorative wall light, wall mounted, in durable plastic body with suitable for LED bulb complete all as specified and as directed. |
| 67 | M&L for earthing with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5m below normal ground level and filled with 15cm thick alternate layers of charcoal and salt, connected and including GI wire earth lead 4.00 mm dia by means of bolts, nuts, check nuts and washers made of galvanized iron protected (earth plate shall be surrounded by alternate layers of charcoal or coke and common salt in 15cm thick in layers and 15cm width all around earth plate) and 15mm dia GI pipe \\"light grade\\" for protection of earth lead and connected to test point or as directed including PCC pit in Cement Concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) and RCC cover of size 450x450x50mm in RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) reinforced with and including 8mm dia TMT bars @ 100mm centre to centre both ways, galvanised Iron wire mesh, funnel, galvanised iron for watering pipe 20mm bore (dia) medium grade, necessary excavation in soft/loose soil including returning, filling in and removal of surplus soil to a distance of 50m and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and testing on completion and including taking down old existing unserviceable earthing complete all as specified and as directed.Note: (i) PCC chamber shall be constructed atleast 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner.(ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate. |
| 68 | S&F as in repairs Gong Bell of size 8\\", 220 volt complete all as specified and as directed. |
| 69 | S&F as in repairs LED light fitting 40 watt flame proof well glass in die cast Al housing with heat resistant toughened glass, CMRI certified recommended for gas / vapor group of IIA & IIIB Zone 1 and 2 and IP-65 protection complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size including nuts, bolts, etc. as required complete all as specified and as directed. |
| 70 | S&F as in repairs 100 watt highbay light luminare with high pressure die cast housing acting as heat sink in order to ensure better performance of the luminaries after taking down old unserviceable light fitting complete all as specified and as directed.Make : Philips/Wipro/GE/Havells/BajajNOTE:- The contract sum shall be derived by deducting the amount shown in Schedule of Credit attached to this tender, from total amount of Schedule 'A'/BOQ. Please Enable Macros to View BoQ information |