| 1 | Excavating in trenches, n exc 1.5m wide & n exc 1.5m in depth; for foundation etc. or for shafts,cesspits, manholes, pier holes, etc. n exc 10sq m on plan & getting out in soft/loose soil complete as specified |
| 2 | All as per item No 1 above but for depth exc1.5 m but n exc 3.0m depth complete as specified |
| 3 | Returning filling in, including spreading, leveling, watering and well ramming in layers n.exc 25 CM. |
| 4 | Removing excavated soil exc 250m but n exc. 500m & depositing where directed at a level n exc. 1.5 m above the starting point |
| 5 | Demolition and breaking up drain pipe (SGSW)set in cement mortar of 100 mm bore complete all as specified and directed including PCC benching complete all as specified and as directed. |
| 6 | M&L cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) to bed of drain pipes including packing under and haunching against the sides of pipes, after they are laid and tested for 100 mm bore pipe complete all as specified and directed |
| 7 | M&L for 100 mm bore PVC (SWR) pipes single socketed of min 6kgf/cm2 , in any length with rubber ring joints, laid in trenches or in floors and jointed as specified. |
| 8 | Demolition of brick work or stone/boulder masonry, built CM including all quoins, pillars etc. |
| 9 | M&L Brick work with sub class B bricks straight or curved on plan exe 6 m mean radius built in cement mortar 1:4 complete all as specified and as directed |
| 10 | M&L Brick work with sub class B bricks straight or curved on plan to any radius in half brick thick walls, built in cm 1:4 complete all as specified and as directed |
| 11 | Taking down of cement plaster of any description on brick walls of manholes/septic tank etc complete all as specified and directed. |
| 12 | M&L for rendering 15 mm thick in CM 1:4 on fair faces of brick work or concrete surface in finished even with WPC @200ml/bag of cement and smooth without using extra cement complete all as specified Note: WPC will be measured and paid seperatly. |
| 13 | M&L 15 mm thick rendering in CM (1:4) on other than fair faces of brick work or concrete surfaces without using extra cement complete all as specified . |
| 14 | Supply only liquid water proofing compound |
| 15 | M&L for Hardcore of Broken stone gauge n exc. 63mm, deposited, spread & levelled in layers n exc. 15 cm thick, watered & rammed to a true surface complete all as specified |
| 16 | Demolition of plain cement concrete (unreinforced) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 17 | M&L PCC in foundations, filling and mass-concrete type D2 (1:4:8) using 40 mm graded stone aggregate complete all as specified |
| 18 | M&L PCC in surface channel & drains, mass-concrete type B2 (1:2:4) using 40 mm graded stone aggregate complete all as specified |
| 19 | Material and labour Extra for form fair finished drain on channel 30 cm inner girth in cement concrete using extra cement including forms, moulds mitred stoped end etc complete all as specified and directed. |
| 20 | Add or deduct for each 25mm girth or part thereof over or under 30 cm ditto complete all as specified and as directed |
| 21 | M&L for PCC Type B-1, (1:2:4) cast in situ (using 20mm graded crushed stone aggregate) as in benching, haunching including weathering, slightly rounded or chamfered incl necessary formwork as required complete all as specified . |
| 22 | M&L for PCC Type C-1, (1:3:6) cast in situ (using 20mm graded crushed stone aggregate) as in coping incl necessary formwork as required complete all as specified. |
| 23 | Demolition of precast reinforcement cement concrete in ground floor and paving n.exc 15 cm thickness (below or above ground level). |
| 24 | M&L for Providing Precast cement concrete in cover slab for manholes and similar articles with plain faces set in CM (1:4) of concrete 1:1.5:3 type B1 using 20mm graded aggregate complete as specified. |
| 25 | M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) as rough finished surface complete all as specified and as directed. |
| 26 | M&L for TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality confroming to Fe500 |
| 27 | M&L for MS round bars cut o length Fe-290(Gde E-165) , bent to shape required in hooks for manhole covers complete all as specified . |
| 28 | Dismantling of CI/PVC/reinforced concrete drain pipe 100/75 mm dia jointed in cement mortar and taking out of trenches if reqd. |
| 29 | S & F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 30 | Supply and fix 75 mm bore PVC (SWR) bends in any types with acess door complete as specified |
| 31 | S&F PVC (SWR) vent cowl, 110 mm dia complete all as specified and directed. |
| 32 | M & L in repair PVC gully trap125/110mm setting and jointing with solvent cement complete all as specified and directed. |
| 33 | S/F in repair PVC (SWR) floor trap plain with grating including jointing with solvent cement 75mm dia out let complete all as specified and directed. |
| 34 | S&F in repair grating 125mm with waste hole of square/round of PTMT complete as specified |
| 35 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 36 | M & L 75mm thick PCC 1:3:6 type B-2 ( 40mm graded aggregate) thick as in plinth protection finishing the surface even & fair whtiout using extra cement with 10 mm joint , filled with bitumen mastic (mix of bitumen and sandin ratio in 1:2) at 3.0m intervals complete all as specified and directed. |
| 37 | Construction of brick masonary soak well of size 2.40 m.dia x 3.00 m depth will all work like excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/ DWC complete filled with brick bats of size and shown on drawing complete as specified. |
| 38 | Supply and fix Wall Fan 400 mm sweep, AC single Phase 230V 50Hz complete including all accessories as specified and as directed. |
| 39 | Material and labour for point wiring (surface type) with PVC insulated, 1100 volts FRLS grade, unsheathed, single core, multistranded copper conductors 1.5 sq mm (nominal area) for phase, neutral and continuous earth wire drawn through and including PVC Casing -N- capping (medium duty) double lock type of 20mm size with fittings & accessories, pressed steel sunken terminal box(Consealed in wall) made out of 1.6 mm thick MS sheet duly painted with two coats of synthetic enamel paint of approved colour over a coat of red oxide zinc chrome primer and covered with 3mm thick bakelite sheet for fixing switches, socket etc and earth continuity conductor shall be connected to common earth and earth dolly for 5 Amp socket point controlled by one 1 way switch complete all as specified & directed.Note: (i)Cost of cutting of wall, if any, for housing of pressed steel sunken terminal box and also making good the disturbed surfaces are deemed to be included in the unit rate (ii) Wire should be used in proper colour code red/yellow/blue for phase, black for neutral & green for earth. |
| 40 | Material and labour for sub-main wiring (surface type) with two run of PVC insulated, unsheathed, single core, multistranded copper conductors of size 2.5 Sq mm and one run of 2.5 Sqmm copper conductor FRLS grade as continuity earth wire, drawn through and including PVC casing caping including taking down old sub main wiring with casing caping all as specified and as directed. (Note: Three run of 2.5 sqmm copper conductor+One run run Cassing-N-capping shall measured as one unit i.e RM) |
| 41 | Material and labour for switch socket combination 5 Pin, 6 Amps flush type complete all as specified and as directed |
| 42 | Supply & fixing MCB DB (Double door) SPN, 4 way, 200 A rated IP-43,IK-09, sheet steel with bus bar, din rail, neutral link and earth bar including taking down old DB with fitting & fixtures all as specified and directed. |
| 43 | Supply and fix sheet metal enclosure /TPN DBs (Double door) 4 way with 200 amps rated busbar suitable for MCB including taking down old unserviceable enclosure one complete all as specified as directed. |
| 44 | Supply and fix MCB triple pole & neutral 63 amps, 240 volts, 10 KA, 'C' series with all incoming /outgoing connections suitable for 4 way type TPN DB in double door with proper size of aluminium lugs complete all as specified as directed |
| 45 | Supply and fix MCB single pole 6 to 32 amps, 240 volts, 10 KA, 'B' series with all incoming outgoing connections with proper size of lugs complete all as specified as directed. |
| 46 | Supply and fix MCB single pole & neutral 6 to 32 amps, 240 volts, 10 KA, 'C' series with all incoming / outgoing connections with proper size of lugs complete inculding taking down the old unserviceable one all as specified as directed |
| 47 | Material and labour for earthing with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below GL) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth lead wire protected by and including 15mm dia Gl pipe (Light grade) and 20mm dia Gl pipe (medium grade) for watering and connected to control switch as directed including necessary earthwork as in soft/loose soil, concrete pit in PCC (1.3:6) type C1, pre cast RCC (1:1.5:3) type A1 cover slab duly reinforced with 8mm dia TMT bar @ 100mm C/C both way and two Nos lifting handle made of 12mm dia TMT bar and set in cement mortar (1:4), funnel, wire mesh, char coal or coke and salt in alternate layer, testing, etc complete all as specified in electrical plate No 3 of SSR Part-I. |
| 48 | NOTES :-1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum.2. Unless otherwise specified the rates for PCC shall deemed to include the cost of formwork shuttering etc, required for complete and proper execution of the work. Refer Schedule 'A' notes for details. Please Enable Macros to View BoQ information |