| 1 | Suppy & fix in repair Flat Plate collector suitable for Solar Hot Water System based on indirect transfer of heat of capacity 100 LPD, complete all as specified and as directed. |
| 2 | Suppy & fix in repair Flat Plate collector suitable for Solar Hot Water System based on indirect transfer of heat of capacity 200 LPD , complete all as specified and as directed. |
| 3 | Suppy & fix in repair Flat Plate collector suitable for Solar Hot Water System based on indirect transfer of heat of capacity 300 LPD , complete all as specified and as directed. |
| 4 | Taking down carefully copper/aluminum point wiring (light. Fan, socket or power) complete, incl fittings such as switches, ceiling roses, pendants, regulators, sockets etc, removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors etc, complete all as specified and as directed. |
| 5 | M&L for point wiring in PVC casing caping with 2.5 Sqmm size multi stranded FRLS copper conductor cable including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated fire retardant cable of size 2.5 Sqmm as earth continuity conductor, complete all as specified and as directed. |
| 6 | S&F switch piano Flush type, single pole16 amp 240 volts, complete all as specified and as directed.equivalent. |
| 7 | S&F Socket outlet 2 in 1, 3 pin, 5 and 15 Amps, flush type, complete all as specified and as directed. |
| 8 | Supply and fix in repair backup stainless steel hot water tank duly insultated suitable for Solar Hot Water System of capacity 100 LPD , complete all as specified and as directed. |
| 9 | Supply and fix in repair backup stainless steel hot water tank duly insultated suitable for Solar Hot Water System of capacity 200 LPD , complete all as specified and as directed. |
| 10 | Supply and fix in repair backup stainless steel hot water tank duly insultated suitable for Solar Hot Water System of capacity 300 LPD , complete all as specified and as directed. |
| 11 | Supply and fix in repair copper pipe/tube suitable for use in Solar Hot Water System of size 1/4\\" , complete all as specified and as directed. |
| 12 | S&F GI tubing 20mm medium grade, ISI Marked complete with all fittings and fixtures laid in trenches or laid under floors, fixed on walls with and providing clamps etc complete , complete all as specified and as directed. |
| 13 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m depth for foundation, laying of cables, etc. and getting out in Hard/dense soil, complete all as specified and as directed. |
| 14 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm depth in soil, complete all as specified and as directed. |
| 15 | Removing excavated material (soil ) n.exc 50m and depositing where directed at a level n.exc. where directed at a level n.exc, complete all as specified and as directed. |
| 16 | S&F in repair Bib taps 20 mm Dia, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete, complete all as specified and as directed. |
| 17 | S&F in repair stop valves 20 mm , cast copper alloy screwd down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete , complete all as specified and as directed. |
| 18 | S&F in repair heating element of capcity 1.5KW (Round/Traingle), complete all as specified and as directed. |
| 19 | S&F in repair heating element of capcity 2KW (Round/Traingle), complete all as specified and as directed. |
| 20 | S&F in repair heating element of capcity 3KW suitable for 100/200/300 Ltr Solar Water Heater, complete all as specified and as directed. |
| 21 | Supply and fixing in repair thermostat suitable for 25/50 Ltr Geyser complete , complete all as specified and as directed.. |
| 22 | Supply and fixing in repair thermostat suitable for 100/200/200 Ltr Solar Water Heatre Plant complete, complete all as specified and as directed. |
| 23 | Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including PVC capping & casing not less than 25 mm wide with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4.0 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete.Note :- 2 Runs of main cable and one run earth wire with capping & casing will be measured as one RM for payment. |
| 24 | Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 6 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including PVC capping & casing not less than 25 mm wide with all necessary fitting and including one run single core multistranded copper conductor cable, of size 6.0 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete.Note :- 2 Runs of main cable and one run earth wire with capping & casing will be measured as one RM for payment. |
| 25 | Servicing of geysers of any capacity by opening of entire geyser and cleaning all the sludges, blockages, dust, etc, complete all as specified and as directed. |
| 26 | S&F in repairs PVC connecting pipe 18\\" long with brass adopters for Hot/Cold water and connecting up with complete for 25 /35 / 50 ltrs capacity Geysers including taking down existing unserviceable PVC connecting pipe , complete all as specified and as directed.. |
| 27 | S&F fusible plug melting at 90 - 100 degrees Centigrade including taking down existing uncerviceable fusible plug, complete all as specified and as directed. |
| 28 | S&F high pressure valve with dead weight suitable for 25 / 50 ltrs capacity Geysers including taking down existing unserviceable high pressure valve, complete all as specified and as directed. |
| 29 | S&F bottom covers (set of two halves) duly painted made out of Aluminium / MS sheet of 18 SWG suitable for 25 / 35 / 50 ltrs capacity Geysers including taking down existing unserviciable bottom covers, complete all as specified and as directed. |
| 30 | S&F base assembly complete with inlet, out let, thermostat pipes, drain plug and screws for fixing the element suitable for any make and capacity Geysers complete with nuts, bolts and rubber gasket including taking down existing unserviceable base assembly, complete all as specified and as directed. |
| 31 | M&L for repairs to water heater inner vessel including brazing, welding, testing for a pressure of 3kg / Sq.cm., re-assembling of any capacity Geysers, complete all as specified and as directed. |
| 32 | Supply and fix Plug top 15A 24V , complete all as specified and as directed. |
| 33 | M&L for servicing and repairing Kero-Cum Electric based Hot water plant of any capacity and make, complete all as specified and as directed. |
| 34 | S&F Photo-Cell suitable for 500 Ltr Hamam, complete all as specified and as directed. |
| 35 | S&F 6 Controller suitable for 500 Ltr Hamam, complete all as specified and as directed. |
| 36 | S&F Fuel Pump suitable for 500 ltr Hamam, complete all as specified and as directed. |
| 37 | S&F in repair Nozzle suitable for 500 Ltr Hamam, complete all as specified and as directed. |
| 38 | S&F in repair Ignition Coil suitable for 500 Ltr Hamam, complete all as specified and as directed. |
| 39 | Repair and re-fixing, re-assembling the existing ceIling fan in same original position along with cable after rectification of defects such as apply the one coat varinsh for windings, painting fan blades, changing fan bearning, rewinding of fan, write MES no on fan blades, replacement of fan canopy (top/bottom cover) including nut, bolts and washers, complete all as specified and as directed. |
| 40 | S&F in repair capacitor 1.5/2 mfd suitable for 1200mm sweep ceiling fan, complete all as specified and as directed. |
| 41 | Repair and re-fixing, re-assembling the existing exhaust fan in same original position along with cable after rectification of defects such as apply the one coat varinsh for windings, changing fan bearning, rewinding, replacemnt of rubber bush/ anti vibration pads, mounting frame etc including nut, bolts and washers, complete all as specified and as directed. |
| 42 | Repair and re-fixing, re-assembling the existing Wall fan in same original position along with cable after rectification of defects such as apply the one coat varinsh for windings, changing fan bearning, rewinding of fan motor including nut, bolts and washers, complete all as specified and as directed. |
| 43 | S&F in repair capacitor suitable for wall fan, complete all as specified and as directed. |
| 44 | S&F in repair capacitor 2.5/3 mfd suitable for 250mm/350mm sweep exhaust fan, complete all as specified and as directed. |
| 45 | Supply and fix in replacement plug top 15 Amp, complete all as specified and as directed. |
| 46 | Supply and fix connecting cord 1.5 mtr length with plug top suitable for 1.5/2 KW Geysers, complete all as specified and as directed. |
| 47 | S&F Thermostate including rubber / PVC gasket to be set to a temperature not higher than the range of 70 degree Centigrade suitable for existing geysers of capacity 25 / 35 / 50 ltrs including taking down existing unserviceable thermostate, complete all as specified and as directed. |
| 48 | S&F of Indicator lamp (Pilot lamp) Neon type of red, Green yellow color with rated voltage 220-240 V AC, 50 Hz suitable for indicating power on/ off status in geysers, complete all as specified and as directed. |
| 49 | S&F fusible plug melting at 90 - 100 degrees Centigrade including taking down existing uncerviceable fusible plug, complete all as specified and as directed. |
| 50 | Note:- Schedule of credit Rs 31,000.00 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents. Please Enable Macros to View BoQ information |