| 1 | M&L for 15mm thick plastering in CM (1:4) on one side of lathing in two separate layers finished even and smooth without using extra cement using water proofing compound @ 3% by wt of cement for finished even and smooth (without using extra cement) including demolition of reed, lathing single or double, including battens and plaster or chicken wire lathing with and including provision of GI wire netting 0.71 mm dia and 12 mm mesh lathing in to reed in walls incl all laps cutting and waste complete all as specified and as directed. |
| 2 | M&L for rendering 12 mm thick in CM (1:6) on other side of lathing and surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 3 | S & F 2nd class hard wood scantling as in framed work etc clean sawn complete including dismantling of old one from its position all as specified and directed. |
| 4 | M&L for brick work with sub class `B' bricks (using old size burnt bricks) straight or curved on plan to any radius in half brick thick walls built in CM (1:4) including demolition of old brick work from its position complete all as specified and as directed. |
| 5 | M&L for brick work with sub class `B' bricks(using old size burnt bricks) straight or curved on plan exc 6m mean radius built in CM (1:6) including demolition of old brick work from its position complete all as specified and as directed. |
| 6 | Taking down chowkhat or frames not exc 1.5 Sqm each (without taking off shutter from the frame) complete all as specified and as directed. |
| 7 | Taking down chowkhat or frames exc 1.5 Sqm but not exc 4 Sqm each (without taking off shutter from the frame) complete all as specified and as directed. |
| 8 | S&F in repairs GI tubes medium grade, galvanised wih all fittings and fixed complete to walls and ceiling or laid on floors etc, 15 mm bore complete all as specified and as directed. |
| 9 | S&F in repairs GI tubes medium grade, galvanised wih all fittings and fixed complete to walls and ceiling or laid on floors etc, 20 mm bore complete all as specified and as directed. |
| 10 | S & F second class hardwood weather boarding, clean sawn, plain, 20 mm thick or feather edged 15 mm to 20mm thick and fixed with 30mm laps etc including dismantling of old boarding complete all as specified and as directed. |
| 11 | Material & labour 2nd class hardwood plain, solid straight chowkhats and frames, wrought, framed rebated on the solid,rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed. |
| 12 | S&F factory made 30mm thick, flush shutters, solid core construction, with particle board core and plywood face panels complete all as specified and as directed. |
| 13 | S&F factory made second class hardwood glazed and skeleton door shutters, 30mm thick, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beeds for securing glass etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.20 (b); supplied and fitted to chowkats complete all as specified and as directed. |
| 14 | S&F factory made Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification etc complete all as specified and directed. |
| 15 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification etc complete all as specified and as directed. |
| 16 | S&F steel windows with side hung shutters including box type hinges with steel handle and steel peg stay, complete with glazing bars, devetailed or welded complete all as specified and as directed. |
| 17 | S&F steel windows with side hung shutters including box type hinges with steel handle and steel peg stay, complete without glazing bars, devetailed or welded complete all as specified and as directed. |
| 18 | S&F sheet glass 3 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and as directed. |
| 19 | S&F mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm, fixed with tinned tacks or galvanized wire staples complete all as specified and as directed. |
| 20 | S&F 100 mm size stainless steel butt hinges complete all as specified and as directed |
| 21 | S&F Aluminium handle cast type anodised 150 mm long complete all as specified and as directed. |
| 22 | S&F Aluminium, anodised, barrel tower bolt 200mm long of extruded section and fixed complete all as specified and as directed. |
| 23 | S & F 300 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast-aluminium alloy and fixed complete all as specified and as directed. |
| 24 | M&L for 75 mm thick PCC (1:3:6) type C-2 , (using 40 mm graded stone aggregate) in plinth protection/aprons/path laid to slope of 1:12, finished fair and even without using extra cement with and including all necessary formwork to divide tha area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 10 mm wide joints throughout thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) including demolition of old cement concrete of any description complete all as specified and as directed. |
| 25 | M&L for cement concrete type B-1 (1:2:4) (using 20 mm graded stone aggregate) as in surface channels and drain bed and coping including demolition of old cement concrete of any description complete all as specified and as directed. |
| 26 | M&L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms moulds complete all as specified and as directed. |
| 27 | M & L for PCC 25 mm thick type B-0, (1:2:4) (using 12.5 mm graded stone aggregate) as in levelling course of floor including demolition of old cement concrete of any description complete all as specified and as directed. |
| 28 | M&L for PCC (1:4:8) type D-2, 75 mm thick (using 40mm graded stone agg) as in sub base including demolition of old cement concrete of any description complete all as specified and as directed. |
| 29 | M&L for precast cement concrete type B-1, (1:2:4) (Using 20 mm graded stone aggregate) as in cover slabs, manhole cover, chamber cover and drainge cover set in cement mortar (1:6) including necessary formwok including demolition of old cement concrete of any description complete all as specified and as directed. |
| 30 | S&F in repairs rotational moulded polyethylene 500 Ltrs Capacity water storage tanks double layer (cylindrical vertical with closed top) hoisted and fixed in position in SSR Part-I with and including ball brass valve, with polythelene float and fly nut complete screwed down for iron pipe of 20 mm dia complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 31 | S&F in repairs rotational moulded polyethylene 500 Ltrs Capacity water storage tanks double layer (cylindrical vertical with closed top) hoisted and fixed in position in SSR Part-I with and including ball brass valve, with polythelene float and fly nut complete screwed down for iron pipe of 20 mm dia complete all as specified and as directed. Please Enable Macros to View BoQ information |